Linkam Scientific Instruments Ltd

Similar documents
Linkam Scientific Instruments Ltd

Linkam Scientific Instruments. PE95 / T95 System Controller USER GUIDE

ZEPHYR Compact Haze Machine

Quick Start Guide. 2MP 4X PTZ IP Camera O2P4X

USER MANUAL. For XLCD17-LED XLCD19-LED

Thermoelectric Cooler Controller TED1000

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

EPS Power Supply

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

A120 A W/240W PA Mixer-Amplifier 70V/100V

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

User Manual DUO BEAM/RG

27" Cinema Display WQHD 2560x1440 IPS LED Monitor Quick Start Guide KALED27MONC

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

SOLARIMMERSION IV Advanced Installation Manual v1.9

Economy Single Channel Output DC Power Supply

Solis Single Phase Inverter

Model HM-535 Power Supply Installation and Service Instructions

4-CHANNEL DMX WALL-MOUNTED CONTROLLER

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

QIT600F1 USER'S GUIDE

Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses.

Expansion Module HZS 541-1S

User's Guide. Model High Precision Quad Output DC Power Supply

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

Startup Guide C01

7 Digital Photo Frame

99 Washington Street Melrose, MA Phone Toll Free Visit us at

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

Manual. Dimmer DMD-12-2

Full HD IP Vandal Dome Camera

GCI-5K INSTALLATION AND OPERATOR S MANUAL

Linkam Scientific Instruments

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Antenna Distributor ORDERCODE D1444

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

PRECAUTIONS FOR USE. Be sure to use indoor wiring within the specified voltage requirements. For extension cord, use the specified rating or more.

DOT MATRIX PRINTER SP6000 SERIES

Marshall Lynx LCD Universal Monitors

Universal AC Power Source + AC Power Analyzer

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

High Precision Quad Output DC Power Supply

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Blue Weapon Laser. User manual UK. Version 1.0

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

DM25, DM40. Compact 100V mixer-amplifiers with Bluetooth. Item ref: UK, UK User Manual

MyGenie TM 32 Thermal Block

RZ2 BioAmp Processor. Operator s Manual

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

MICRON DJ Booth System with Overhead Kit & CW Starcloth

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

PROFESSIONAL SHOW LIGHT

Sonneteer. Orton Integrated Amplifier

Operating Instructions

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

Spectrum Laser. User manual UK. Version 1.0

Integrated video camera ImageCam USER S INFORMATION. Camera control panel

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

Advidia A-15 & A-35 Installation Manual

ColourChaser Touch. Installation Guide

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

Orchestra Orchestra reference

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Jadis I-35. Owner's Manual. Integrated amplifier

VTPC190V / VS / VDC / VSDC

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Quick Start Guide and Health and Safety Information

Dimmer DPX terminal

ENG. LCD Monitor Series Prestigio P TFT Active Matrix LCD Panel User s Manual. Prestigio P1910 1

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

RZ5/RZ5D/RZ6 Processor. Operator s Manual

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

OPERATION MANUAL MODEL TT-LP

AquaController Apex Probe Module 2

Available in 2.0MP, 4.0MP and 8.0MP variants

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

FastCam Outdoor Speed Dome Camera

Table of Contents. Federal Communications Commission (FCC) Statement...2

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

AD-400. CD Player with USB/SD and FM Tuner. Item ref: UK User Manual

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

903 PORTABLE TEMPERATURE TEST UNIT

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Operating Instructions

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

Precision Balance W3200 Series Operating Manual

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

Transcription:

Linkam Scientific Instruments Ltd User s Guide Page 1

Contents Regulatory Compliance... 3 Important Notice... 4 Warranty... 4 Technical Support... 4 Equipment Maintenance... 4 CI94 Technical Specification... 5 CI94 Equipment Ratings... 5 Safety Precautions... 6 Symbol Reference... 6 Introduction... 7 Various Cables and Connections... 8 Stage Lead... 8 RS232 Lead... 8 I2C Cable... 8 Back Panel Programmer Connections... 9 Front Panel Controller Buttons... 10 Setup Menus Explained... 11 Working with the Setup Menus... 12 Linksys Temperature Control Software... 17 Getting Started... 17 Setting up a Temperature Profile... 17 CI94 Manual Page 2

Regulatory Compliance Page 3

Important Notice Please check that your Linkam equipment has not been damaged during transport. If there is any evidence of external damage DO NOT SWITCH ON ANY ELECTRICAL ITEMS. Contact LINKAM SCIENTIFIC or their appointed distributor immediately. Your warranty maybe impaired if Linkam is not informed of any transport damage within 7 days of delivery. NO attempt should be made to repair or modify the equipment in any way, as there are no user replaceable parts. No attempt should be made to open the case except by qualified personnel as hazardous voltages are present. Please contact Linkam for custom modifications for specific applications. In order to use this equipment successfully, please take time to read this manual all the way through before starting to work. Warranty This equipment has a warranty against defects in material and workmanship for a period of 12 months. Linkam will either repair or replace products that prove to be defective. For warranty service or repair, this product must be returned to Linkam or a designated service facility. The warranty shall not apply to defects resulting from interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or maintenance. Technical Support Any technical questions or queries should be addressed to the Technical Support Department at the address shown on the back of this manual. Equipment Maintenance The programmer does not require any regular maintenance. If for any reason it is necessary to check the electronic calibration then a set of standard resistances can be supplied, which simply plug into the programmer in place of the stage, and indicate known temperature values. The standards are traceable to NAMAS. Before cleaning the case or front panel of the programmer, remove the mains lead from the wall outlet. Use a small quantity of isopropyl alcohol on a soft cloth and gently wipe the surface. CI94 Manual Page 4

CI94 Technical Specification Stages using a platinum resistor sensor Temperature Range: -196 C to 600.0 C (dependent on Stage) Temperature Stability: +/-0.1 C over the operating temperature of 10 to 40 C Set Point Resolution: 1 C Temperature Display: 0.1 C resolution Control Stability: All stages stable to +/-0.1 C Temperature Sensor: Pt100 1/10 DIN or 0.01 Ohm at 0 C Temperature Accuracy: +/-0.1 C Display: 1 row of 16 characters, 5.5mm high LCD display with backlight Dimensions 310 x 230 x 80 (deep) mm Weight: 2.44 Kg (including remote control and stage cable ) Operating environment: 5 ~ 40 C 80% relative humidity at 31 C decreasing linearly to 50% at 40 C (without condensation) CI94 Equipment Ratings A.C.Mains Supply: 90-264 ~ A.C.Frequency: 47-63 Hz Max current: 2A Fuse: 2.5A (F) 250V~ Fuse must be replaced by one of the same type and rating. Page 5

Safety Precautions 1) Read all of this guide before using the equipment. Save these instructions for later use. 2) Follow all warnings and instructions which may be placed on the programmer or stage. 3) If for any reason the mains fuse needs to be replaced then it must be replaced by one of the same type and rating as shown in the equipment ratings. 4) To prevent electric shock, do not remove the cover of the controller or associated electronics. 5) Never use the equipment if a power cable has been damaged. Do not allow any heavy objects to rest on the power cables. Never lay the power cables on the floor. 6) Do not obstruct any ventilation holes. Do not attempt to insert anything into these openings. Provide adequate ventilation of at least 75mm all around the equipment. 7) Do not expose the equipment to water. If for any reason it gets wet then unplug it from the mains and contact Linkam Scientific Technical Support. The equipment is not intended to be used outdoors. 8) Each product is equipped with a 3-wire grounded (earth) mains plug or a free-end 3 wire mains lead. The plug only fits into a grounded-type outlet. The free-end mains lead should be connected to a correctly grounded 3-wire mains outlet. Do not defeat the purpose of the grounded (earth) type plug. Free - end mains leads are colour coded as follows : Colour Brown Blue Green/Yellow Function Live Neutral Earth (Ground) 9) If any problems occur then unplug the all the equipment from the mains outlet and contact Linkam Scientific Technical Support. 10) Do not remove the cover from the equipment unless the mains inlet has been removed. Any servicing should be carried out by qualified service personnel. Symbol Reference Caution - This safety symbol is seen on the backpanel of the equipment and warns:- The user must not make or remove any connections while the unit is powered on. To avoid electric shock do not remove the cover. Refer servicing to qualified service personnel. Caution - This warning symbol indicates that the surface labelled with this symbol may be hot. CI94 Manual Page 6

Introduction The CI94 (Computer Interface) has been specifically designed to give precise temperature control of the Linkam range of heating/freezing Stages. Digital linearisation of the Stage s sensor gives accurate temperature values whilst the function keys have been carefully chosen to allow rapid changes in data values. A varying d.c. signal is used to control the Stage and results in an even application of power which avoids the bursts seen with conventional burst fire a.c. techniques. Much finer control of the Stage temperature can be now be achieved over the whole range. Automatic control of the LNP 94/2 is possible which reduces the amount of liquid nitrogen used and gives more repeatable results as the flow is continuously changed according to the set conditions. The rate, limit and temperature can be superimposed onto a Video Camera Signal using a Linkam VTO232 Video Interface from the output provided. The Linksys temperature control software enables extremely accurate and complex temperature profiles to to be carried out and can be linked with the Linkam Real Time Video Measurement software so that temperature control information can be in laid upon digitally captured images. Page 7

Various Cables and Connections Stage Lead This D type end of the cable plugs into the socket on the back of the CI94 marked, Stage Lead. Screw in the connector so that it does not dislodge accidentally during a profile. The stage lead is specific to the stage, it carries information in the connector that tells the programmer which stage is connected. IN SPITE OF APPEARANCE NOT ALL STAGE LEADS ARE THE SAME. This end of the stage lead is called a lemo connector and plugs directly into the stage. RS232 Lead This cable is the communication cable between the PC and the CI94 when using the Linksys temperature control software, or downloading CI94 software update. Both ends are similar. One end plugs into the socket marked RS232 on the back of the CI94 and the other end plugs into either COMM1 or COMM2 serial ports on the back of your PC I 2 C Cable This cable is the communication cable between the CI94 and the LNP94/2 Automatic Cooling pump (or VTO232). Both ends are 4 pin connectors and plug into the sockets marked I 2 C on the back of the CI94 and LNP94/2. (It does not matter which I 2 C socket this cable is plugged into, there is no IN or OUT socket i.e the two sockets next to each other on the LNP94/2) CI94 Manual Page 8

Back Panel Programmer Connections Stage lead Expansion port (Not Used with CI94) I/O port for remote control RS232 communication cable to PC Power cable Mode Switch for Rateloading upgrades I 2 C communication between programmer and other electronic Linkam products e.g LNP, VTO On/Off Power Switch Page 9

Front Panel Controller Buttons Move down a menu screen UP Move up a menu screen CANCEL Cancels current menu screen and drops down to previous set of menus Selects menu option or moves up to next set of menus. Also exits a profile if software control is lost due to crash or RS232 cable loosing its connection. CI94 Manual Page 10

Setup Menus Explained The setup menus are accessed by following the instructions on the next few pages. The dotted lines lead to the menu screen that will be seen when the button shown next to the line is pressed. Sample Calibration The output from the platinum resistor in the Stage is accurately converted to temperature in the CI94 to better than 0.01 C. The platinum resistor is mounted as near to the top surface of the silver or copper block as possible, which due to its high thermal conductivity gives very little temperature difference. However, when the sample is thick or if the sample is placed on a cover slip or crucible, it is possible that some temperature gradient can appear, causing the known temperature characteristics of a material to change. Using the sample calibration features of the CI94, these known (theoretical) values and the experimental values can be used by the CI94 to draw a new temperature curve. A positive and a negative temperature as well as a value for zero can be entered, although it is not necessary to enter all three sets of data. For instance the zero value can be left at zero and just a positive or negative value determined and entered. This can be done in thelinksys software by selecting Calibration then clicking Sample Cal. Possible temperature difference between sample and heater caused by a thick sample. T sample T block Ideal line shows no temperature difference between sample and heater. Unit Details These menus need to be quoted when you request a software update for your CI94. Test Modes These menus are for fault finding when contacting Linkam by phone or email. Vstg + Istg These values are the Voltage (V) of the Stage and the current (I)of the Stage. Vres +Vfan These values are the Voltage resevoir and the Voltage of the fan. Electronic Cal This contains the menu Instrument Cal which re-linearises the on-board resistor. The Stage/mod setup menu allows the chip in the stage lead to be reprogrammed without the unit needing to be returned to Linkam. RS232 Page 11

This menu allows you to set the speed of the RS232 port if creating your own control software. It also allows you to set parity. Contact Linkam for Serial Comms manual. Display contrast This menu allows you to set the contrast of the screen from 1 to 9. Working with the Setup Menus When the CI94 is switched on the display automatically scrolls through five screens. Linkam CI94 To access the setup menus press the button when you see this screen. If Enter is not pressed the screens will scroll as follows. For Menu > Enter Connected to THMS600 Stage 25.2 C The CI94 can be fitted with two different options; Vacuum or DSC If the vacuum board is fitted, the CI94 will display a reading of either mbar or Torr in the linksys temperature window. If the DSC board is fitted, the CI94 will display a reading of DSC counts also shown in Linksys temperature window. Depending on whch board is fitted the screens will scroll as shown to the right. OR With Option FDCS Ver 1.0 DSC Ver 1.0 25.2 C CI94 Manual Page 12

OPTION SETUP MENU INFO/SELECT Sample Cal Reset Values Values reset Unit details Firmware version Ver 1.0 15-01-01 Options Fitted FDCS VER 1.0 Serial Number 0102-008-0001 Hardware version Ver 1.1 14-04-00 Vacuum Units Display in mbar CANCEL Display in Torr CANCEL Page 13

SETUP MENU OPTION INFO OR SELECT Sample Cal Unit details Vacuum Units Test Modes Vstg + Istg Sample Cal CANCEL Vres + Vfan The screen will scroll through start messages and then alternate between the temperature values and the Vstg + Istg values CANCEL Sample Cal The screen will scroll through start messages and then alternate between the temperature value and the Vres + Vfan values Electronic Cal Instrument Cal In Calbration The screen will scroll through start messages Stage/mod setup This is for Linkam production, (See Section Setup Menus Explained - Electronic Cal.) CI94 Manual Page 14

SETUP MENU OPTION INFO OR SELECT Sample Cal Unit details Vacuum Units Test Modes Electronic Cal RS232 Port 9600 baud (See Section Setup Menus Explained ) Contrast > 6 UP Display contrast Contrast = 5 Contrast > 5 Contrast > 4 Page 15

SETUP MENU OPTION INFO OR SELECT Sample Cal Unit details Vacuum Units Test Modes Electronic Cal RS232 Port Display contrast Temp to 0.01 C UP Temp resolution Temp to 0.1 C CI94 Manual Page 16

Linksys Temperature Control Software Getting Started Full explanation of all the Linksys 32 menus and options are explained in the Help in the software. Presuming that you have already installed Linksys 32 correctly (Installation information on the software CD supplied with Linksys 32), open the program from your windows START menu. Now go to File > Connect You will then see the following message telling you to power up your linkam equipment connected to comm port 1. Power on your CI94 controller and click OK The room temperature will now be displayed in the tool bar. Setting up a Temperature Profile In order to setup a temperature control experiment using the temperature profile table, you will first have to select this from the Temperature Control Setup menu. Go to the toolbar and select Setup > Temperature Controller. Select the Use Profile check box and then close the menu window. Now go back to the tool bar and select View > Profile Type in the rate of heating, the limit and the time to hold the limit temperature in each ramp of the profile. Right click your mouse on the last ramp in the table to Set the End Row Page 17

Press the start button to start the profile as entered in the Profile Table Start and Stop buttons You can override the Temperature Profile table by either highlighting the rate, limit and hold info in the temperature control panel (shown to the right), and simply typing the value you require, or you can use the nudge buttons found to the right of the values to nudge each value up or down in 1 unit increments. Nudge controls To show an online plot, select View > Real Time Chart from the toolbar. You will see the chart below updating the temperature plot in real time. Real Time chart CI94 Manual Page 18

Page 19

Linkam Scientific Instruments Ltd 8 Epsom Rates Metro Centre, Waterfield, Tadworth, Surrey, KT20 5LR, England +44 (0) 1737 363476 +44 (0) 1737 363480 info@linkam.co.uk http://www.linkam.co.uk Ver 1.2 24/04/2008 CI94 Manual Page 20