Channel Switch CS. General Operating, Maintenance and Installation Manual

Similar documents
HEC. General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual

IPC194. ipconv Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V3 (Linux OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

MC 11 EB-2 Power supply cabinet with external bus, AC version

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Manual Industry Interfaces

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

GT- IRDM-9603 Product description Rev. 2 17/06/2014

TRC-190 User s Manual

PHOENIX CONTACT - 07/2006

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Operating Instructions

ANC Series RS-422 Serial Communications Adapter

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

TRC-190 User s Manual

G.SHDSL NTU with Fixed Serial Interfaces

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

RS-232 Industrial Media Converter

TRIO-DIODE/12-24DC/2X10/1X20

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

TF501, TF521 Terminal Bases

OPERATING INSTRUCTIONS

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

CPCI-ASIO4 CAN - RS-232, RS-422, RS-485

Media Converters. Media Converters. Product Selection Guides

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

DI572 Digital Input Module

DI561 Digital Input Module

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

ZM24x Quick-Connect Industrial Modem. User s Manual

F1000 User's Manual. (Version: V1.01)

B63/ NS MS. EtherNet/IP LINK

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

ISOLATED RS-232 TO RS-422/485 CONVERTER

icore Kiosk system Installation Guide

Storage/Control I/O Module

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Vision OPLC V TR6/V350-J-TR6

Serial PROFIBUS Interface

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

4170 POS System Installation Guide

ADA User Manual ADA Separator - Repeater RS-232. io_ada-1010_v3.20_en. Copyright CEL-MAR sp.j.

TU531, TU532 Terminal Unit

AO561 Analog Output Module

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

PTZ Control VMC Joystick

Enclosure TS-530 User Manual

Enhanced Mini-Chansim Model VCS-232

SeaLINK+232I USER MANUALM

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

QUINT-BUFFER/24DC/24DC/40

AI561 Analog Input Module

Perle MCR200 Installation Guide

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

RocketPort Plus Hardware Installation

Operating instructions. Standstill monitor A / / 2011

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Miniature Asynchronous 4-Wire High Speed Modems

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

NT1B-300 Rack Installation Instructions

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

RS-232/RS-422 Optical Isolator

An ISO-9001 Certified Company

MGate 4101-MB-PBS Series

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

-C5RS-LC RS232 EXTENDER

Installation & Operation Guide

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

Operating Instructions VEGAMET 381

DX561 Digital Input/Output Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DC562, digital input/output module,

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

NCH-1000 (Multiple Breaker Types) Installation Instructions

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

Transcription:

Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September 2010 Version 2.1.4

Index 1 INTRODUCTION... 2 2 GENERAL SPECIFICATION... 3 2.1 APPLICATION... 3 2.2 NOMENCLATURE... 4 2.3 OPERATION... 5 2.4 MOUNTING AND DISMOUNTING... 6 2.5 ELECTRICAL INSTALLATION... 7 2.5.1 Circuit Diagram... 7 2.5.2 Pin Allocation... 8 2.6 ELECTRICAL COMMISSIONING... 9 2.7 MAINTENANCE... 10 2.8 JUMPER SETTINGS... 11 2.9 SCOPE OF DELIVERY... 12 3 APPENDIX A TECHNICAL DATA SHEET... 13 4 APPENDIX B DECLARATION OF EEC COMPLIANCE... 16 IPCOMM GmbH - 1 - CS Manual

1 Introduction All technical information, specifications and illustrations contained in this Operating, Maintenance and Installation Manual remain our property and shall not be used otherwise than for operating this product, nor shall they be copied, reproduced or passed on to third parties or brought to their notice without our prior written consent. The information represented in this manual is in keeping with current standards and is subject to later alterations. This manual contains important instructions referring to safe installation, commissioning, operation and maintenance. Read this manual carefully before starting up the Channel Switch and observe the instructions. Although a surge test has been successfully completed (up to 0.5 kv) the operator should, if necessary, implement appropriate protection measures against the possible impact of lightning. Caution! The Channel Switch is a class A device. This device can cause radio disturbances in residential buildings. In this case the operator might be obliged to carry out appropriate measures and take responsibility. All trademarks and brand names contained in this user manual are for identification purposes only and can be owned by their respective holders. Finally we want to draw your attention to the fact that any warranties with respect to the delivered goods will be invalid in the event that: Operation, servicing and maintenance are not carried out accurately according to the instructions, repairs are not carried out by our personnel or without our prior written consent. Commissioning is not carried out by our personnel or we have not given our approval for the commissioning or the commissioning is carried out by untrained personnel. The unit is used inadequately, incorrectly, negligently or inappropriately or for a purpose other than that originally intended. The serial number is removed from the product. IPCOMM GmbH - 2 - CS Manual

2 General Specification 2.1 Application The Channel Switch is used for switching data and control signals in control direction in a redundant system. Figure 2.1 shows how the Channel Switch is embedded into the system. It has been designed for switching the communication channels via an RS232 interface in redundant Protocol Converter systems. (DTE) RS232 (DTE) The Channel Switch is connected to two Protocol Converters, PC1 and PC2 (DTE Data Terminal Equipment) and a Data Communication Equipment (DCE). The links between the devices are established via RS232 interfaces. In the system shown opposite the Protocol Converter PC1 is the active one, i.e. it communicates with the Data Communication Equipment, while the other Protocol Converter PC2 remains passive. Fig. 2.1: Channel Switch in a redundant system If the first Protocol Converter fails or needs to be switched off for maintenance during operation the second Protocol Converter resumes communication automatically. It sends a switchover command of a defined pulse string to the Channel Switch. If the Channel Switch recognizes this pulse string as valid, the Channel Switch relays the data and control signals from the second Protocol Converter to the Data Communication Equipment. The connection to the first Protocol Converter is shut off. Only the data and control signals in control direction, those are TX, DTR and RTS signals, are redirected. A bistable relay control inside the Channel Switch enables to preserve the former switch position, even if the operating voltage is turned off. Only a defined series of pulses can activate the switch. IPCOMM GmbH - 3 - CS Manual

2.2 Nomenclature The circuitry of the Channel Switch is housed in a robust aluminium casing. The ports for connecting to the Protocol Converters and the Data Communication Equipment as well as four LEDs for displaying the operating state of the Channel Switch are located on the front panel. On the back you will find the clip for mounting on a 35 mm DIN rail. The respective position of the parts mentioned is shown in figure 2.2. 1 2 1 2 3 Display P: Operational Indicator (red) E: Error Indicator (red) A or B: Active Channel (green) DB9 Sockets (DCE) DB9 Plug (DTE) 3 4 Connector for external Power Supply: + 24 V DC, (other on request) 4 Fig. 2.2: Nomenclature IPCOMM GmbH - 4 - CS Manual

2.3 Operation The Channel Switch (protection class IP 40) has been designed for installation in a switch cabinet and is supplied with 24 V DC via an external power supply. In order to maintain operating function, greater variations in temperature should be avoided. We recommend an air-conditioned operating environment for the Channel Switch. Possible sources of interference, such as current inverters and power current lines near the Channel Switch should be avoided. In order to ensure problem-free operation the following conditions have to be observed: Temperature Range: 0 C 55 C Relative Humidity: 5 % - 95 % non-condensing Installation as per IP 40, i.e. installation site and environment comply with the appropriate degree of protection. The housing is not protected against the penetration of water! The supply voltage must remain within the permissible voltage range (see technical data sheet) Mounting on electro-conductive and grounded DIN mounting rail. Note: Important: Excessive voltages either fed directly via the power voltage or indirectly via data and control lines, mains power lines or as a result of voltage excesses to the Channel Switch might cause damage to the Channel Switch. Possible interferences of this kind must be avoided. Provided that a power supply is delivered by IPCOMM GmbH, the required instructions can be found in the enclosed operating manual. IPCOMM GmbH - 5 - CS Manual

2.4 Mounting and Dismounting Since there is a clip on the back panel of the housing no tools or additional material are required for mounting the Channel Switch on the DIN rail. Figure 2.4.1 opposite shows how the Channel Switch is mounted on DIN rail C. By pressing in the direction of marked point B clip A snaps into place on the DIN rail. The casing is grounded via the DIN rail. It must therefore be ensured that the DIN rail is electroconductive and grounded. Fig. 2.4.1: Mounting the CS For dismounting push the casing in the direction of marked point D while pulling at the bottom side of the casing towards point E (see figure 2.4.2). Fig. 2.4.2: Dismounting the CS IPCOMM GmbH - 6 - CS Manual

Power Supply + 24 VDC 2.5 Electrical Installation 2.5.1 Circuit Diagram The Channel Switch is connected to the Protocol Converters and the Data Communication Equipment as shown by the following circuit diagram, fig. 2.5.1. The operating voltage of the Channel Switch is + 24 V DC 10 %, optional 12 V DC 10 %. Mains Protocol Converter #1 (DTE) Protocol Converter #2 (DTE) 5 6 CS 8 7 Data Communication Equipment (DCE) CS 9 5 Serial interface cable 1 : 1, shielded Included 10 6 Serial interface cable 1 : 1, shielded Included CS 7 DB9 null modem cable, shielded, female female Optional Chassis ground via the electro-conductive and grounded DIN mounting rail. 100 240 V AC Mains 8 9 10 2 cores connector cable, min. 0.5 mm 2 Not included Socket connector BL 3.5 for connecting the external power supply. For cable size: 0.5 1.5 mm 2 Included Fig. 2.5.1: Electrical Installation OMRON power supply Input voltage : 100 240 V AC Output voltage : 24 V DC 10 % Nominal power : 15 Watt Optional The power input of a Channel Switch is approx. 0.5 Watt. The maximum number of Channel Switches to be connected in parallel circuit is therefore limited by the maximum rating of the power supply. Important: In order to comply with regulations on electromagnetic compatibility, keep data lines and the 24 V power supply cord of the Channel Switch as short as possible. IPCOMM GmbH - 7 - CS Manual

2.5.2 Pin Allocation Figure 2.5.2 shows the pin allocation for the Channel Switch. The pins marked with an * are required for communication. 9-pin external DTE (towards the Communication Equipment) 9-pin internal DCE (towards the Protocol Converter) 1 (CD) 5 (SGnd) * * (DSR) 6 2 (RX) * * (RI) 9 4 (DTR) * * (RTS) 7 3 (TX) * * (CTS) 8 3 (Tx) * * (CTS) 8 * (RTS) 7 4 (DTR) * 2 (Rx) * * (RI) 9 5 (SGnd) * * (DSR) 6 1 (CD) * Abb. 2.5.2 Pin allocation for the Channel Switch RTS: Request To Send CTS: Clear To Send DTR: Data Terminal Ready Rx: Receive Data Tx: Transmit Data SGnd: Signal Ground DSR: Data Set Ready RI: Ring Indicator CD: Carrier Detect IPCOMM GmbH - 8 - CS Manual

2.6 Electrical Commissioning After completing the electrical installation of the Channel Switch as shown in circuit diagram 3.5.1 electrical commissioning can begin. Immediately after starting up the power unit, the Channel Switch executes an internal initialization sequence. The red LED (P) indicates that the operating voltage is on. In addition the current switch position of the bistable relay inside the Channel Switch and the currently active channel are identified. This is indicated by the green LED (A) or (B). LED (A) indicates that channel A is connected to the Data Communication Equipment. Correspondingly LED (B) shows that channel B is connected to the Data Communication Equipment. The initialization procedure takes about 55 ms. Subsequently you can start communication between the active Protocol Converter and the Data Communication Equipment. If LED (E) lights up shortly an error has occurred. In this case the Channel Switch initializes automatically. Such an error could be caused by a temporary malfunction of the serial interfaces. IPCOMM GmbH - 9 - CS Manual

2.7 Maintenance Generally the Channel Switch is maintenance-free. Fig.2.7.2 shows the assembled circuit board of the Channel Switch. The centerpiece of the circuit board is the µ-controller. µ-controller Fig. 2.7.1: Channel Switch, open Fig. 2.7.2: Circuit Board Channel Switch Should it become necessary to replace the µ-controller, proceed as follows: 1. Disconnect the Channel Switch from the mains, detach the data lines. 2. After dismounting as per point 2.4, remove the side panel of the housing as shown in fig. 2.7.1 by loosening the 4 screws. 3. The µ-controller is removed from the PLCC socket by means of the PLCC pliers. Apply the pliers in such a way that the parts marked with an A correspond to those of the socket (see fig. 2.7.2, 2.7.3 and 2.7.4). 4. When inserting the new µ-controller ensure that the slanting edge of the µ-controller corresponds to that of the socket. Important: Any transfer of charges to the µ-controller must be avoided. 5. Carefully push the µ-controller into the socket. Then replace both side panels of the casing. Tighten the 4 housing screws. 6. After proper mounting the Channel Switch can be put into operation again. A slanted edge A Fig. 2.7.4: Socket for µ-controller Fig. 2.7.5: µ-controller A A Fig. 2.7.3: PLCC pliers IPCOMM GmbH - 10 - CS Manual

2.8 Jumper Settings Jumpers JP3 and JP4 JP3 JP4 Case 1-2 3-4 5-6 7-8 9-10 11-12 1-2 3-4 5-6 7-8 9-10 11-12 1 J J J J J J 2 J J J J J J 3 J J J J J J J Blank = Jumper in = no Jumper Case 1 = State of active channel identified by Carrier Detect (Pin 1) Case 2 = State of active channel identified by Data Set Ready (Pin 6) Case 3 = State of active channel identified by Ring Indicator (Pin 9) IPCOMM GmbH - 11 - CS Manual

2.9 Scope of Delivery Channel Switch (CS) Serial interface cable 1:1, about 1,8 m (2 pieces) Socket connector 3,5 mm Optional: OMRON power unit for the external power supply of the Channel Switch 100V-240 V AC / 24 V DC, 15 W IPCOMM GmbH - 12 - CS Manual

3 Appendix A Technical Data Sheet IPCOMM GmbH - 13 - CS Manual

Technical Data Sheet Interfaces RS232 (V.24) 9 pin SUB-D Socket (connects to DCE) 9 pin SUB-D Plug (connects to DTE) Baudrate up to 38400 Baud CD or DSR or RI for indicating the active channel to the protocol converters Function Display 4 LEDs Switchover Time 140 ms (measured after last valid pulse) Power Supply 24V DC 10% external, optional 12 V DC 10% Power Input approx. 0,5 W Protection Requirement IP 40 Norms CE-certified Housing Aluminum, surface passivated, with clip for mounting on 35 mm DIN rail Dimensions (without clip fastener) Width: 44 mm Height: 105 mm Depth: 104 mm Operating Environment Operating temperature / storage temperature: 0 C to 55 C / - 10 C to 70 C Relative humidity: 5 % to 95 % (non-condensing) IPCOMM GmbH - 14 - CS Manual

IPCOMM GmbH - 15 - CS Manual

4 Appendix B Declaration of EEC Compliance IPCOMM GmbH - 16 - CS Manual

Declaration of EEC Compliance For the following product Channel Switch (CS) it is hereby confirmed that it complies with the main specifications laid down in the Council Guidelines on Harmonizing the Statutory Regulations of the Member States for Electromagnetic Compatibility (89/336/EWG). Any changes to the Channel Switch not authorized by IPCOMM GmbH invalidate this declaration. The evaluation of this product for electromagnetic compatibility was carried out in accordance with the following standards: EN 55022/1998 EN 50082-2/1996 Place/Date/Manufacturer's Signature: Erlangen, 15 March 2004 Position of Signatory: Managing Director, Artur Votteler IPCOMM GmbH - 17 - CS Manual