ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1

Similar documents
ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

ASCO 920 Remote Control (RC) Switches

MAJOR VA Power Inverter

920 Remote Control (RC) Switches

Toll Free: Tel: Fax:

Rugged MediaConverter

Surge Protective Devices. Installation & Operation Manual. Model 570/575. Model 575 Model 570 Model 565 Model 560. Model 560/565

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

AP41 / AP81 SERIES TIME SWITCHES

Surge Protectors and Digital Timer

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Industrial Power Supplies

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Level-Lance Model 5400A

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

BSPD Surge Protective Devices

Specifications, Installation, and Operating Instructions

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

Stride Industrial Ethernet Switches

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

PanelView Plus/VersaView CE Terminals and Display Modules

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB

Surge Protection Solutions. Industrial Market Automation Market OEM Market

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Model #: INTERNET750U

Grid to Chip Surge Protection Product Catalog

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB

Signamax Connectivity Systems

Industrial Power Supplies

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

AI130 AIswitch Series 130 Chassis Installation Guide

SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System

Installation Job Aid for Ethernet Routing Switch 3600 Series

SCADAPack E 5405 Digital Input Hardware Manual

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Hardened PoE Ethernet Switch

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

Line Impedance Stabilization Network (LISN)

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

RT4F-110V/25A RECTIFIER

4600 Series RAID-Enabled

Powerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)

Hardened Media Converter

Model #: ECO350UPS. 350VA Eco Energy-Saving UPS System. Highlights. Description. Features

TAA-Compliant ECO Series 120V 550VA 300W Energy-Saving Standby UPS with USB monitoring and 8 Outlets

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

Single Phase Systems-North American PC125/PC420 Series

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal

Surge Protective Devices. STV25K Series. Instruction Manual

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Eaton s SPD Series for integration into electrical distribution equipment

5401 and 5402 Digital I/O Modules

TAA-Compliant POS Series 120V 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

TPE 1464 Series Pressure Transducer

ECO Series 120V 900VA 480W Energy-Saving Standby UPS with USB, Muted Alarm and 12 Outlets

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

ECO Series 120V 350VA 180W Energy-Saving Standby UPS with USB and 6 Outlets

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

Model 7705 Control Module

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

7-Outlet Home/Business Theater Surge Protector, 6-ft. Cord, 2100 Joules, Tel/Modem/Coax Protection

UPS READY POWER DISTRIBUTION ASSEMBLY

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port

H-series (Rectifier Module)

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal

3500/32M 4-Channel Relay Module

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Easy To Use OEMS Take Note

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

Transcription:

ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-1

DATA SHEET SSF-86-3 ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-1 Solid State Flasher: Description: The PDC model SSF-86 solid state flasher is a dual circuit flasher designed for the Traffic Control Industry. This unit is conservatively rated up to 20 A per circuit. The flash rate is 56.25 flashes per minute and does not vary due to voltage or temperature variations. With the zero voltage switching design, there are no contacts to wear out or deteriorate due to arcing or corrosion. Also, extended life of the bulbs can be expected as well as reduced Radio Frequency Interference (RFI). The extruded aluminum heatsink provides more than adequate heat dissipation. Connector Pinout: Mates with a Beau P-5406-LAB or equivalent Electrical Characteristics: Zero voltage turn on----------------------------------- Zero voltage turn off----------------------------------- Tungsten Lamp or Gas Tubing Transformer load- Operating Voltage------------------------------------- Mechanical---------------------------------------- 0V +-5 degrees 0A +-5 degrees Up to 20 A max. 60-135 VAC Length 8.40 inches Width.1.70 inches Height 4.18 inches Weight 1.135 lbs Operating Temperature : Full load from 35 to +74 degrees C Guarantee: The flasher is fully guaranteed against all failures due to manufacturing defects for two years. P.O. Box 7172 #205, Stateline, NV. 89449 PH (925) 455-7711 FAX (925) 455-7714

ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-2

DATA SHEET SSF-86-3 ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-2 Solid State Flasher: Description: The PDC model SSF-86 solid state flasher is a dual circuit flasher designed for the Traffic Control Industry. This unit is conservatively rated up to 20 A per circuit. The flash rate is 56.25 flashes per minute and does not vary due to voltage or temperature variations. With the zero voltage switching design, there are no contacts to wear out or deteriorate due to arcing or corrosion. Also, extended life of the bulbs can be expected as well as reduced Radio Frequency Interference (RFI). The extruded aluminum heatsink provides more than adequate heat dissipation. Connector Pinout: Mates with a Beau P-5406-LAB or equivalent Electrical Characteristics: Zero voltage turn on----------------------------------- Zero voltage turn off----------------------------------- Tungsten Lamp or Gas Tubing Transformer load- Operating Voltage------------------------------------- Mechanical---------------------------------------- 0V +-5 degrees 0A +-5 degrees Up to 20 A max. 60-135 VAC Length 8.40 inches Width.1.70 inches Height 4.18 inches Weight 1.135 lbs Operating Temperature : Full load from 35 to +74 degrees C Guarantee: The flasher is fully guaranteed against all failures due to manufacturing defects for two years. P.O. Box 7172 #205, Stateline, NV. 89449 PH (925) 455-7711 FAX (925) 455-7714

AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-2 The AP21 is a single-circuit, calendar-programmable, solid state time switch. It is primarily designed for switching electric circuits according to a pre-set time and date program. The AP21 auto prompting alpha-numeric display makes programming transfers fast and simple by using our AP21 software on a laptop. The AP21 may be powered from any120vac or 12VDC supply. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved.

AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance AP21 SPECIFICATIONS DESCRIPTION Fast and simple programming using our AP21 software on a laptop. DISPLAY KEYBOARD BACK-UP POWER ELECTRICAL CONNECTION OUTPUT POWER TIME BASE SIZE TEMPERATURE RANGE One-line, 16 character alpha-numeric Liquid Crystal Display (LCD) Sixteen-key, positive action push button 48-hour capacitive Terminal block (#12 to #20 AWG) optional CPC connector with harness SPDT relay rated at 15 amps 115 VAC resistive load 0.25 Watt at rest, 0.76 Watt relay ON, 12VDC AC Power = 60Hz line power DC Power = Temperature-compensated crystal with accuracy of +/-.005 seconds/day 7.6"H x 3.7"W x 1.55"D -30 to +74 Celsius AP21 FEATURES One-line, sixteen-character, Liquid Crystal Display (LCD) 16 character, alpha-numeric keypad Automatic Daylight Saving Time (DST) adjustments Time of day entered in 12-hour format Automatic Leap Year compensation 48-hour capacitive memory back-up no batteries to replace The display Auto Prompts the operator through the user-friendly programming process 16 powerful program steps Single Day, Weekend, Week Day, or Every Day programming capability for each program step 10 skip plans each skip plan prevents the time switch output from activating on a specific day or consecutive days SPDT relay output rated at 15 Amps at 115 VAC resistive load Works on 120VAC and 12VDC power sources AP21 ORDERING INFORMATION PART NUMBER DESCRIPTION 501614 Single-circuit time switch The AP21 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved. 102714

ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-3

ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-3 200 SERIES Model 254 (Edco ACP-340) 120 VAC Single Phase Surge Protective Device Technical Documentation The ASCO Model 254 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters may pass through. It designed to protect intersection controllers and other sensitive equipment from random time-base, memory loss and other more sever transient related problems. Model 254 can replace the existing EMI filter in the traffic cabinet if high frequency attenuation over 25 MHz is not required. Key Specs Voltage: 120 VAC Current: 10 Amp Connection: 1/4-20 Stainless Steel Lugs Mounting: Flange *See Ordering Information for model number selection General Technical Specifications Operating Voltage Clamping Voltage Operating Current Peak Surge Current Operating Frequency EMI Attenuation SPD Technology Modes of Protection Connection Type Operating Temperature Dimensions (in/mm) Weight (lb/kg) Warranty 120 VAC 395 VAC 10 A 32.5 ka/mode, 65 ka/total 47-63Hz 60 db typ Metal Oxide Varisters (MOV) w/ L-C Filter L-N, N-G 1/4-20 Stainless Steel Stud -40 C to +85 C 2.375 H x 3.125 W x 7.125 L [60.3 x 79.4 x 181.0 mm] 1lb, 13.5 oz. [ 0.84 kg] 5 years Features Industry-Leading Noise Filtering Nanosecond response time Incorporates series choke 5 Year Warranty V DANGER! Only qualified personnel should install or service this system. Electrical safety pre-cautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. Seulement le personnel qualifié doit installer ou maintenir ce systéme. Des précautions de sécurité en électricité doivent être suivis lors de l installation ou de la maintenance de cet equipement. Pour eviter tout risque de choc électrique, débranchez et verouiller toutes les sources d alimentation de cet equipement avant de. Caution This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specifications. Appropriate precautions should be exercised. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only.

Installation Instructions Circuit Breaker 10A Max. Cabinet Power AC Hot Bus 120 VAC Input Earth Site Variable (opiton) Main Line Main Neutral Earth Model 254 Ground Line Out Neutral Out Protected Power Source (to controller and other sensitive electronics) Dimensions Ordering Information MODEL Former Model Name 254120NF010AN5NO Edco ACP-340 APPLICATION 120VAC, 10A ASCO Power Technologies 14550 58th St. North, Clearwater, FL 33760 surge.ascopower.com customercare@ascopower.com 1-800-237-4567 Copyright January 2018. Publication ID-50175 RevA

AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-3 The AP21 is a single-circuit, calendar-programmable, solid state time switch. It is primarily designed for switching electric circuits according to a pre-set time and date program. The AP21 auto prompting alpha-numeric display makes programming transfers fast and simple by using our AP21 software on a laptop. The AP21 may be powered from any120vac or 12VDC supply. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved.

AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance AP21 SPECIFICATIONS DESCRIPTION Fast and simple programming using our AP21 software on a laptop. DISPLAY KEYBOARD BACK-UP POWER ELECTRICAL CONNECTION OUTPUT POWER TIME BASE SIZE TEMPERATURE RANGE One-line, 16 character alpha-numeric Liquid Crystal Display (LCD) Sixteen-key, positive action push button 48-hour capacitive Terminal block (#12 to #20 AWG) optional CPC connector with harness SPDT relay rated at 15 amps 115 VAC resistive load 0.25 Watt at rest, 0.76 Watt relay ON, 12VDC AC Power = 60Hz line power DC Power = Temperature-compensated crystal with accuracy of +/-.005 seconds/day 7.6"H x 3.7"W x 1.55"D -30 to +74 Celsius AP21 FEATURES One-line, sixteen-character, Liquid Crystal Display (LCD) 16 character, alpha-numeric keypad Automatic Daylight Saving Time (DST) adjustments Time of day entered in 12-hour format Automatic Leap Year compensation 48-hour capacitive memory back-up no batteries to replace The display Auto Prompts the operator through the user-friendly programming process 16 powerful program steps Single Day, Weekend, Week Day, or Every Day programming capability for each program step 10 skip plans each skip plan prevents the time switch output from activating on a specific day or consecutive days SPDT relay output rated at 15 Amps at 115 VAC resistive load Works on 120VAC and 12VDC power sources AP21 ORDERING INFORMATION PART NUMBER DESCRIPTION 501614 Single-circuit time switch The AP21 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved. 102714

ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-4

ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-4 200 SERIES Model 254 (Edco ACP-340) 120 VAC Single Phase Surge Protective Device Technical Documentation The ASCO Model 254 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters may pass through. It designed to protect intersection controllers and other sensitive equipment from random time-base, memory loss and other more sever transient related problems. Model 254 can replace the existing EMI filter in the traffic cabinet if high frequency attenuation over 25 MHz is not required. Key Specs Voltage: 120 VAC Current: 10 Amp Connection: 1/4-20 Stainless Steel Lugs Mounting: Flange *See Ordering Information for model number selection General Technical Specifications Operating Voltage Clamping Voltage Operating Current Peak Surge Current Operating Frequency EMI Attenuation SPD Technology Modes of Protection Connection Type Operating Temperature Dimensions (in/mm) Weight (lb/kg) Warranty 120 VAC 395 VAC 10 A 32.5 ka/mode, 65 ka/total 47-63Hz 60 db typ Metal Oxide Varisters (MOV) w/ L-C Filter L-N, N-G 1/4-20 Stainless Steel Stud -40 C to +85 C 2.375 H x 3.125 W x 7.125 L [60.3 x 79.4 x 181.0 mm] 1lb, 13.5 oz. [ 0.84 kg] 5 years Features Industry-Leading Noise Filtering Nanosecond response time Incorporates series choke 5 Year Warranty V DANGER! Only qualified personnel should install or service this system. Electrical safety pre-cautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. Seulement le personnel qualifié doit installer ou maintenir ce systéme. Des précautions de sécurité en électricité doivent être suivis lors de l installation ou de la maintenance de cet equipement. Pour eviter tout risque de choc électrique, débranchez et verouiller toutes les sources d alimentation de cet equipement avant de. Caution This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specifications. Appropriate precautions should be exercised. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only.

Installation Instructions Circuit Breaker 10A Max. Cabinet Power AC Hot Bus 120 VAC Input Earth Site Variable (opiton) Main Line Main Neutral Earth Model 254 Ground Line Out Neutral Out Protected Power Source (to controller and other sensitive electronics) Dimensions Ordering Information MODEL Former Model Name 254120NF010AN5NO Edco ACP-340 APPLICATION 120VAC, 10A ASCO Power Technologies 14550 58th St. North, Clearwater, FL 33760 surge.ascopower.com customercare@ascopower.com 1-800-237-4567 Copyright January 2018. Publication ID-50175 RevA

AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-4 The AP22 Time Switch is a two-circuit, calendar programmable solid state time switch. It is used for switching electric circuits according to a pre-set time and date program. It has the ability to run up to ten different day plans and thirty-six different annual exception plans to accommodate different school calendars and/or traffic patterns throughout the year. The AP22 auto prompting alpha-numeric display makes programming fast and simple. Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved.

AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi AP22 SPECIFICATIONS DESCRIPTION Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. DISPLAY KEYBOARD BACK-UP POWER OUTPUT POWER TIME BASE Two-line, 16 characters per line Liquid Crystal Display (LCD) Sixteen-key, positive action push button Non-volatile memory Two SPDT relays rated at 15 amps 12VDC or 115 VAC resistive load Less than 0.25 Watt at rest, 0.6 watt with relay ON, 12VDC AC Power = 60Hz power line DC Power = Temperature-compensated crystal with accuracy of.35 seconds/day SIZE 10 3/8"h x 4 3/4"w x 2"d TEMPERATURE RANGE -30 to +74 Celsius AP22 FEATURES Two-line, sixteen-character, Liquid Crystal Display (LCD) Automatic Daylight Saving Time adjustments Program memory stored for years - no batteries to replace The user-friendly display auto-prompts the operator through the programming process Ten day plans, sixteen program steps per plan accommodate standard school day, school holidays, early dismissal days, summer school days, etc. Standard week plan programming uses any day plan for the most complicated school schedule Thirty-six annual programs use exception-day programming to assign any day plan to any calendar day(s) Two independent 15-amp relay outputs Program transfers from unit to unit Works on 120VAC and 12VDC power sources AP22 ORDERING INFORMATION PART NUMBER DESCRIPTION 503644 Two-output time switch with CPC connector and 48" wiring harness 504558 Program transfer cable 500517 AC power cable with connector The AP22 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved. 030514

AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-5 The AP22 Time Switch is a two-circuit, calendar programmable solid state time switch. It is used for switching electric circuits according to a pre-set time and date program. It has the ability to run up to ten different day plans and thirty-six different annual exception plans to accommodate different school calendars and/or traffic patterns throughout the year. The AP22 auto prompting alpha-numeric display makes programming fast and simple. Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved.

AP22 TIME SWITCH 2-Way Radio / Cellular / Ethernet / Wi-Fi AP22 SPECIFICATIONS DESCRIPTION Upload and download programming via 2-Way Radio, Cellular, Ethernet, Wi-Fi or Laptop. DISPLAY KEYBOARD BACK-UP POWER OUTPUT POWER TIME BASE Two-line, 16 characters per line Liquid Crystal Display (LCD) Sixteen-key, positive action push button Non-volatile memory Two SPDT relays rated at 15 amps 12VDC or 115 VAC resistive load Less than 0.25 Watt at rest, 0.6 watt with relay ON, 12VDC AC Power = 60Hz power line DC Power = Temperature-compensated crystal with accuracy of.35 seconds/day SIZE 10 3/8"h x 4 3/4"w x 2"d TEMPERATURE RANGE -30 to +74 Celsius AP22 FEATURES Two-line, sixteen-character, Liquid Crystal Display (LCD) Automatic Daylight Saving Time adjustments Program memory stored for years - no batteries to replace The user-friendly display auto-prompts the operator through the programming process Ten day plans, sixteen program steps per plan accommodate standard school day, school holidays, early dismissal days, summer school days, etc. Standard week plan programming uses any day plan for the most complicated school schedule Thirty-six annual programs use exception-day programming to assign any day plan to any calendar day(s) Two independent 15-amp relay outputs Program transfers from unit to unit Works on 120VAC and 12VDC power sources AP22 ORDERING INFORMATION PART NUMBER DESCRIPTION 503644 Two-output time switch with CPC connector and 48" wiring harness 504558 Program transfer cable 500517 AC power cable with connector The AP22 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved. 030514

AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-7 The AP21 is a single-circuit, calendar-programmable, solid state time switch. It is primarily designed for switching electric circuits according to a pre-set time and date program. The AP21 auto prompting alpha-numeric display makes programming transfers fast and simple by using our AP21 software on a laptop. The AP21 may be powered from any120vac or 12VDC supply. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved.

AP21 TIME SWITCH Industry Standard, Time-Tested School Zone Appliance AP21 SPECIFICATIONS DESCRIPTION Fast and simple programming using our AP21 software on a laptop. DISPLAY KEYBOARD BACK-UP POWER ELECTRICAL CONNECTION OUTPUT POWER TIME BASE SIZE TEMPERATURE RANGE One-line, 16 character alpha-numeric Liquid Crystal Display (LCD) Sixteen-key, positive action push button 48-hour capacitive Terminal block (#12 to #20 AWG) optional CPC connector with harness SPDT relay rated at 15 amps 115 VAC resistive load 0.25 Watt at rest, 0.76 Watt relay ON, 12VDC AC Power = 60Hz line power DC Power = Temperature-compensated crystal with accuracy of +/-.005 seconds/day 7.6"H x 3.7"W x 1.55"D -30 to +74 Celsius AP21 FEATURES One-line, sixteen-character, Liquid Crystal Display (LCD) 16 character, alpha-numeric keypad Automatic Daylight Saving Time (DST) adjustments Time of day entered in 12-hour format Automatic Leap Year compensation 48-hour capacitive memory back-up no batteries to replace The display Auto Prompts the operator through the user-friendly programming process 16 powerful program steps Single Day, Weekend, Week Day, or Every Day programming capability for each program step 10 skip plans each skip plan prevents the time switch output from activating on a specific day or consecutive days SPDT relay output rated at 15 Amps at 115 VAC resistive load Works on 120VAC and 12VDC power sources AP21 ORDERING INFORMATION PART NUMBER DESCRIPTION 501614 Single-circuit time switch The AP21 Meets NEMA TS1/TS2 Requirements RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved. 102714

M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using SMS Texting The RTC Model TSC2G is a compact communications modem that allows the user to connect an RTC Time Switch to a central computer using SMS texting. The TSC2G provides full, two-way communications from a central ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-9 computer to any Model AP22 or CPR2102 Time Switch via SMS texting eliminating the need for any additional infrastructure. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved.

M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using SMS Texting M2M FEATURES Two-way communication with AP22 and CPR2102 time switches using SMS texting (no additional infrastructure required) Omni antenna typically mounts inside the flasher cabinet, an external Omni antenna is available if required LED indicator for power and SMS network connection Compact size: 3.4"w x 2.4"h x 1"d with mounting tabs Simple, plug-and-play operation Make program changes anytime day or night Operating temperature range: -30 to +75 Celsius M2M SPECIFICATIONS DESCRIPTION DIMENSIONS 3.4"w x 2.4"h x 1"d POWER OPERATING TEMPERATURE SMS ANTENNA OPTIONS PROGRAMMING MANUAL CONTROL VALIDATE PROGRAMMING 12VDC, powered from DB9 on time switch -30 to +75 Celsius Short Message Service Omni antenna mounted inside the flasher cabinet (standard) Omni antenna mounted outside the flasher cabinet (if required) Make programming changes to your school zone flashers anytime from a PC or laptop connected to the internet Send manual control commands at anytime, day or night Validate the program in any time switch at anytime, day or night GPS Time sync reference and map location services M2M SERVICE PLANS: Choose from a 5-year or 10-year service agreement RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved. 030514

M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using Cellular Technology The RTC M2M is a compact communications modem that allows the user to connect an RTC Time ODOT ITB 063-19 Section 4: Flashers, Timers, & Software Systems Item 4-10 4G Modem With Paddle Antenna, Less Communication Plan Switch to a central computer using RTC Connect software. The M2M provides full, two-way communications from a central computer to any Model AP22 or CPR2102 Time Switch. This eliminates the cost and maintenance of additional infrastructure. RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2014 RTC Manufacturing, Inc. All Rights Reserved.

M2M CELLULAR COMMUNICATIONS MODEM Communicates With School Zone Flashers Using Cellular Technology M2M FEATURES Simple, plug-and-play operation Powered directly by RTC time switches with no external power supply needed Make program changes anytime Modems are fully certified and carrier approved Two-year warranty Time Switch time is synchronized daily with cell tower time Can be mounted directly to time switch Antenna typically mounts inside the flasher cabinet; an external antenna is available if required; other antenna optional, as needed LED indicator for power and cellular network connection Extended warrranties up to five years available M2M CERTIFICATIONS REGULATORY COMPLIANCE FCC Class B (US), IC (Canada) SAFETY UL 60950-1 (US), cul 60950-1 (Canada) QUALITY MIL-STD-810: high-temp, low-temp, cold dwell, random vibration and sine vibration SAE J1455: random vibration and sine vibration M2M SERVICE PLANS Choose from one, five, or ten-year service agreement OPTIONAL GPS ENABLED DEVICE AVAILABLE Time sync reference and map location services M2M SPECIFICATIONS DESCRIPTION DIMENSIONS 2.45"W x 3.17"H x 1.16"D WEIGHT.65 LB TIME SYNC Cell System GPS CHASSIS TYPE Aluminum OPERATING TEMPERATURE -40 to +85 Celsius HUMIDITY Relative Humidity 15% to 93% non-condensing SMS Short Message Service Supported PERFORMANCE HSPA+ FREQUENCY BAND Hepta-band 850/900/AWS 1700/19002100 MHz RTC CONNECT TM COMMUNICATION FLOW RTC DATA SERVER CELL CARRIER Central Traffic Office Running RTC Connect TM Two-way Internet Communication Two-way Internet Communication Two-way Cell Communication RTC-Traffic.com contact our team at Info@RTC-Traffic.com for more information TOLL-FREE 800.782.8721 FAX 817.274.3610 RTC Manufacturing, Inc., 1016 Enterprise Place, Arlington, Texas 76001 2015 RTC Manufacturing, Inc. All Rights Reserved. 012315