Installation VAV-Compact Retrofit Set

Similar documents
Brief description. Type overview

Brief description. Type overview

Products no longer available

Brief description. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection.

VAV system solution for non-pressure dependent applications in enclosed spaces

Technical data sheets

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Technical data sheet. Technical data

Technical data sheet

BUS. Adaptive control system for pressure applications (STP) Table of contents

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Power consumption In operation At rest For wire sizing

BUS. Adaptive VAV control system for sensitive working areas. Table of contents

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Functional data Factory settings Variable Setting Torque Inhibiting torque

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Control equipment EMBL

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Products no longer available

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Ready for the volumetric flow systems of tomorrow.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Products no longer available

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

s Spring return C / max C

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VAV compact controller GDB181.1E/3 GLB181.1E/3

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Control equipment EMBL

VAV compact controller KNX / PL-Link

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

Belimo Gateway MP to Modbus RTU - UK24MOD

Overview of types. Technical data

Variable Flow Rate Control Unit

VAV compact controller

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Product information. Technical data. Safety notes. Definitions

Belimo Gateway MP to Modbus RTU - UK24MOD

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Product information. Technical data. Safety notes. Definitions

VAV modular controller

VAV modular controller

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Rotary version, three-position control

InReg Volume flow controller Pa

N20, N34 SERIES. NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR FLOATING / 2-POSITION CONTROL SPECIFICATIONS GENERAL FEATURES

Technical data. Safety notes. Product features

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

VAV Modular Assembly (VMA) 1410/1420

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Handheld Tool for VAV compact and modular controllers

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Air damper actuators

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

InBin-P Pressure switches from 5 Pa Pa

VAV Compact Controller Modbus RTU

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Non-communicating room controllers

PC-Tool - Module NMV-D2M V2.1

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Control components for VAV terminal units

ZN230-24MP-1 MP-BUS

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Installation & Operation Guide

SITRANS F Coriolis Flowmeters SITRANS FCT030 transmitter Quick Start

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Room Pressurization Controller Electronic Output

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

FXVMA Variable Air Volume (VAV) Box Controller

N05010/N10010 NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING / 2-POSITION CONTROL SPECIFICATIONS

OpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Ag Leader Technology. DirectCommand Installation Rogator 900/1100/1300 Sprayers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

ASV215BF152*: VAV compact controller for laboratory and pharmaceutical applications

Transcription:

VAV-Compact Retrofit Set NMV-D3-RE-SET VAV-Compact Retrofit Set for utilisation of existing VAV devices made by various manufacturers. for various air velocities Suitable for round VAV boxes only. General Information Application The VAV-Compact Retrofit Set was designed for the retooling of existing VAV-/CAV units. Thanks to the set solution, the replacement of VAV control devices from a wide variety of manufacturers, including pneumatic solutions, is exceptionally simple. The set contains all of the components required for the conversion. The ZTH-GEN service tool is used for the adaptation of the VAV-Compact Retrofit to the existing VAV unit and the air velocity. The setting data required for this purpose are already stored in the VAV-Compact Retrofit in a table, the «TypeList». This simplifies the conversion sequence and reduces the amount of time required for its completion. Package contents 4 3 VAV controller NMV-D3-RE Pick-up device ZPD-RE 3 Anti-rotation stud 4 Form-fit insert 8 x 8 mm instructions These installation instructions describe the application of the VAV-Compact Retrofit Set NMV-D3-RE-SET. For a detailed description of the VAV controller, we draw your attention to the respective separate product documentation for VAV-Compact, ZTH-GEN and NMV-D3-MP; see www.belimo.eu. Belimo Automation AG can at any time implement changes and improvements without prior notification. For the current edition of the operating instructions, see www.belimo.eu Safety notes! The device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during installation. The device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. The cable must not be removed from the device. When calculating the required torque, the specifications supplied by the damper manufacturers (cross section, design, installation site), and the air flow conditions must be observed. The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. www.belimo.eu M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes / 8

Dismantling the existing VAV controller Electrical connection Mechanical components. In the control cabinet, undo supply / signal cable to the outgoing terminals Caution: Observe and note connection sequence. Undo supply/signal cable to the VAV controller Caution: Observe and note connection sequence. Dismantling the existing pick-up device. Dismantling the controller 3. Dismantling the actuator of the new pick-up device Measured value recording The installation position and the inflow of the pick-up device are of decisive importance for measuring accuracy. If the measurement recording is positioned in an area of turbulence or if no sufficiently wide-ranging flow takes place, then measurement inaccuracies could occur under certain circumstances. Placement A B A B Measurement site Maximum hose length 3 m per measurement line position D = 00 50 D = 80 400 4 3 4 Air duct Bore hole for pick-up device installation 3 Clearance between the pick-up devices 4 Air direction D B [mm] 80 0 35 47 355 79 400 34 D = 00 50 D = 80 400 Two pick-up devices are required for VAV boxes from 80 to 400 mm. For this purpose use the ZPD-RE-SET. / 8 M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes www.belimo.eu

VAV-Compact Retrofit Set of the new pick-up device (Continued) Preparations. Shorten the pick-up device to the diameter of the VAV unit. The auxiliary template is located on the packaging of sets. The specified lengths must be maintained without fail in order to ensure that the desired measuring accuracy can be achieved.. Mount pick-up device seal 3. Drill an opening in the duct; hole size: 36 mm. of the pick-up device in the duct Caution: Observe direction of arrow and of air +. Mount pick-up device with accompanying screws www.belimo.eu M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes /8

of the new VAV controller Spindle clamp installation The VAV controller NMV-D3-RE is equipped with the base plate for form-fit mounting. The front mounting clip may not be used under any circumstances when the controller is used with clamp connection (Illustration 3). Damage to the VAV unit and/or the VAV controller would be the result. 40 8... 6.7 8 6.7 3 4 0 0 mm 9 Nm Spindle clamp installation with short axes 0 4 / 8 M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes www.belimo.eu

of the new VAV controllers (Continued) with form-fit 8 x 8 mm 5 3 mm Adjusting angle of rotation limiter Incorrect settings can lead to damage to the damper blade and to a diminishment of the quality of the control. The two mechanical end stops for angle of rotation limiting must be tailored to the conditions of the VAV unit and are therefore to be adjusted very carefully. The dismantled actuator is used as an orientation aid for placing the end stops. Attaching hoses to the controller and pick-up device. Mount the two accompanying angle pieces to the connection nipples of the pick-up device.. Attach hoses to VAV controller with pick-up device Caution: Observe connection (±) Depending on the type of installation of the VAV controller, individual parts such as screws, formfit insert or universal mounting brackets are not required and remain left over after completion of the installation. www.belimo.eu M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes 5 / 8

Electrical connection of the new VAV controller The VAV controller NMV-D3-RE is equipped with a 4-wire connecting cable. An electrical connection socket should be used for ensuring a permanent connection with the existing installation. Cable connection Supply via safety isolation transformer!! Connections, (AC/DC 4 V) and 5 (MP signal) must be routed to accessible terminals (room temperature controller, floor distributor, control cabinet, etc.), in order to simplify access with the ZTH-VAV or with the PC-Tool for diagnostic and service work. The connection is made using the connecting cable mounted to the VAV-Compact device. No. Designation Wire colour Function black Supply AC/DC 4 V + ~ red + ~ 3 Y white Reference signal VAV/CAV 5 U orange Actual value signal MP-Bus connection Settings and commissioning Settings with ZTH-GEN TypeList function The adaptation of the VAV-Compact Retrofit Set to the nominal width of the VAV/CAV unit is accomplished by shortening the differential pressure sensor in accordance with the auxiliary template (see page 3). The TypeList stored in the NMV-D3-RE contains the parameter sets for the following unit diameters. ZTH-GEN service tool TypeList For air velocities up to m/s For air velocities up to 6 m/s TypeList designation VAV unit [mm] nom [l/s] nom [m 3 /h] TypeList designation VAV unit [mm] nom [l/s] nom [m 3 /h] ZPD- m/s 00 00 97 349 ZPD-6 m/s 00 00 48 75 ZPD- m/s 5 5 53 55 ZPD-6 m/s 5 5 77 76 ZPD- m/s 60 60 50 900 ZPD-6 m/s 60 60 5 450 ZPD- m/s 00 00 403 45 ZPD-6 m/s 00 00 0 76 ZPD- m/s 4 4 55 890 ZPD-6 m/s 4 4 63 945 ZPD- m/s 50 50 67 ZPD-6 m/s 50 50 309 ZPD- m/s 80 80 795 86 ZPD-6 m/s 80 80 398 43 ZPD- m/s 35 35 08 370 ZPD-6 m/s 35 35 54 85 ZPD- m/s 355 355 75 4590 ZPD-6 m/s 355 355 638 95 ZPD- m/s 400 400 676 6034 ZPD-6 m/s 400 400 838 307 The desired data record can be selected with the TypeList function of the ZTH-GEN or of the PC-Tool. For the functions and applications of the ZTH-GEN, see separate service tool documentation. Available at www.belimo.eu or from your local Belimo representative. / 8 M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes www.belimo.eu

Settings and commissioning (continued) ZTH-GEN preparation Expert and Advanced option enabled (Configuration menu) Enter OEM number A password (OEM number) is required for access to the TypeList function of the VAV-Compact Retrofit. Please contact your local Belimo representative. Applying the TypeList sequence ZTH-GEN TypeList function Pull out the ZTH-GEN RJ plug Preparation Start function Cancel, Exit Press button + + TypeList is read Connect service plug to the VAV-Compact Connect ZTH-GEN RJ plug Scroll + ZPD- m/s 00; ZPD- m/s 5;... Select type VAV-Retrofit Vxx ZPD- m/s 5 ZPD- m/s 5 Write? ZPD- m/s 5 Write Standard function Start/End RJ plug Device identification Type Position Address Serial number 'Designation' type is written in the 'Designation' string Type Firmware + Type Designation Jump to max setting Example: Address: PP 00... NMV-D3-... FW: V... NMV-D3-RE ZPD- m/s 5 + + 0... max min... nom min new: max new: 0 m3/h 5 m3/h 55 m3/h 400 m3/h min / max are stored as 'OEM values' Setting parameters nom / p @ nom Manual setting Adapting the actuator (angle of rotation) The following parameters are to be adjusted in relation to the VAV unit or to the room, respectively: min Minimum volumetric flow max Maximum volumetric flow Mode Control signal Y (0... 0 V /... 0 V) Direction of rotation Opening damper cw (clockwise) or ccw (counterclockwise) For ZTH-GEN preparation, see above. p @ nom (pick-up device ZPD, page 6) Air velocity up to 6 m/s: 38 Pa Air velocity up to m/s: 50 Pa nom in accordance with pick-up device ZPD, page 6 min see above... An adaption is made to adapt the actuator to match the available damper angle of rotation, e.g. 60. This procedure should be carried out at the time of commissioning after each adjustment to the angle of rotation limitation. Switch on the 4 V supply Press the 'Adaption' push-button. The actuator now moves to the CLOSE OPEN setpoint position. www.belimo.eu M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes 7 / 8

Functional check After the adjustment has been completed, it is recommended that a functional check be carried out on the VAV/CAV unit. The VAV controller is set to the desired operating mode with the ZTH-GEN and a setpoint/actual value comparison is made. ZTH-GEN Stage selection Volume Stage 400 m3/h > max< Available stages CLOSED / min / max / Motor stop / OPEN Possible sources of errors If the setpoint is not achieved, then this could be for several reasons: No volumetric flow or negative p value, respectively: Pressure hoses incorrectly connected Direction of rotation set incorrectly Fire damper closed Actual volumetric flow is too low: Supply pressure too low (supply pressure control, FU setting, air performance too low) Damper spindle is mounted with an offset (damper cannot be opened all the way) Extended energy-savings measure Single room control Fan Optimiser System Extended energy savings measures and comfort enhancements can be achieved through the utilisation of the BELIMO single room controller CR4.. and through the integration of the VAV system in a Fan Optimiser System You will find more detailed information on these components and systems at the BELIMO web site www.belimo.eu or consult your local BELIMO representative. 8 / 8 M4-VAV-Compact Retrofit Set en v.0.0 Subject to changes www.belimo.eu