Open Networking Testing Service Open Network Systems Interoperability Test Report

Similar documents
Open Networking Testing Service Open Network Systems Interoperability Test Report

Open Networking Consortium Open Network Systems Interoperability Test Report

Open Networking Consortium Open Network Systems Interoperability Test Report

ENSURING INTEROPERABILITY FOR OPEN NETWORKING SYSTEMS WHITE PAPER. March 10, 2016

40 and 100 Gigabit Ethernet Consortium Interoperability Test Report

40 AND 100 GIGABIT ETHERNET TESTING SERVICE

UNH-IOL MIPI Alliance Test Program

OSPF NSSA Operations Test Report Revision 1.7. InterOperability Lab 121 Technology Drive, Suite 2 Durham NH,

GIGABIT ETHERNET CONSORTIUM

40 and 100 Gigabit Ethernet Consortium Clause 86 40GBASE-SR4 and 100GBASE-SR10 PMD Test Suite v0.1 Technical Document

Gigabit Ethernet Consortium Point-to-Point Interoperability Test Suite v2.3 Report

UNH-IOL MIPI Alliance Test Program

Bridge Functions Consortium Spanning Tree Protocol Operations Test Suite Version 2.0

Wireless LAN Consortium abgn Infrastructure Interoperability Test Suite v4.4 Report

UNH-IOL Open Networking Consortium

RIPv2 Interoperability Test Report Revision 1.1

Data Center Bridging Consortium

10 Gigabit Ethernet Consortium 10GBASE-R PCS Test Suite version 0.4

Wireless LAN Consortium Wireless WPA AP MAC Test Suite v2.4 Report

OpenFabrics Alliance Interoperability Logo Group (OFILG) May 2013 Logo Event Report

OpenFabrics Alliance Interoperability Logo Group (OFILG) January 2014 Logo Event Report

UNH-IOL PCIe CONSORTIUM

SFF-8431 SFP+ Technology

Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software

Interoperability Logo Group (OFILG) July 2017 Logo Report

OpenFabrics Alliance

N1014A SFF-8431 (SFP+)

Part Number Operating temperature DDMI. APCS43123CDL20 Commercial Yes. APCS43123IDL20 Industrial Yes

SFP+ Dual LC 10G SMF 80Km DWDM 50GHz Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELZQxxFDMAx542

Ethernet SFF-8431 SFP+ SFF-8635 QSFP+ Compliance and Debug Testing. Anshuman Bhat Product Manager

University of New Hampshire InterOperability Laboratory Ethernet Consortium

GEPON OLT PX20+ Optical Module

GEPON OLT PX20++ Optical Module CLEPONOLTPX20++

40GBase QSFP+ PSM4 1.5km Optical Transceiver

OpenFabrics Alliance Interoperability Logo Group (OFILG) May 2011 Logo Event Report

UNH-IOL 121 Technology Drive, Suite 2 Durham, NH OpenFabrics Interoperability Logo Group (OFILG)

T Q S 2 1 L H 8 X 8 1 x x

GEPON OLT Optical Module

Methode Electronics. DM-383-XXX 4 Channels of 10Gbps QSFP+ by 4* SFP+ Passive Cable.

10 GIGABIT ETHERNET. 10GBASE-T Physical Layer Interoperability Test Suite Version 1.0. Technical Document. Last Updated: October 3, :30 PM

OpenFabrics Alliance Interoperability Logo Group (OFILG) Dec 2011 Logo Event Report

GPON Class C++ SFP OLT Transceiver

OpenFabrics Alliance Interoperability Logo Group (OFILG) January 2014 Logo Event Report

UNH IOL NVMe Test Consortium

UNH IOL SERIAL ATTACHED SCSI (SAS) CONSORTIUM

OpenFabrics Alliance Interoperability Logo Group (OFILG) May 2014 Logo Event Report

Product Specification. 10Gbps 2KM XFP Transceiver PLXFP1310GLR02

InfiniBand Trade Association

APCO10-PPCXXX. 100Gb/s QSFP28 Active Optical Cable. Product Features. Applications. Gb/s QSFP28 Active Optical Cable

University of New Hampshire InterOperability Laboratory Ethernet Consortium

2Mbps 850nm MMF SFP Transceiver 2km HOLS-P1850-LD-CV-B

InfiniBand Trade Association

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

UNH-IOL 121 Technology Drive, Suite 2 Durham, NH OpenFabrics Interoperability Logo Group (OFILG)

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

Agilent N5410A Fibre Channel Automated Test Application

RJ-10G-SX Rugged 10G 1x12 Optical Transceiver Fiber Optic Transceiver

PCI Express 1.0a and 1.1 Add-In Card Transmitter Testing

UNH IOL iscsi CONSORTIUM

Gigabit Ethernet Consortium Clause 36 PCS Conformance Test Suite v2.1 Report

Quad Small Form factor Pluggable Plus (QSFP/QSFP+)

OpenFabrics Alliance Interoperability Logo Group (OFILG) January 2016 Logo Event Report

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

10-Gigabit Ethernet Consortium

InfiniBand FDR 56-Gbps QSFP+ Active Optical Cable PN: WST-QS56-AOC-Cxx

Keysight Technologies N6467A BroadR-Reach Automotive Ethernet Electrical Compliance Application

UNH IOL iscsi CONSORTIUM

OpenFabrics Alliance Interoperability Logo Group (OFILG) May 2014 Logo Event Report

OPTOSTAR's OP-MDCX8xxL1SD-40 10G Cooled EML XFP DWDM transceivers are designed for 10G

ETHERNET. Clause 28 Auto-Negotiation State Machine Base Page Exchange Test Suite v6.4. Technical Document. Last Updated: October 15, :00pm

OpenFabrics Alliance Interoperability Logo Group (OFILG) May 2012 Logo Event Report

Cisco MDS 9000 Family Pluggable Transceivers

Eye-BERT 10G and Micro 10G Software Programming Guide

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

100G SWDM4 MSA Technical Specifications Optical Specifications

HDMI Electrical, Protocol Audio Video ( PAV ) and Content Protection, HDCP

AUTOMOTIVE ETHERNET CONSORTIUM

10G SFP + Bi-di Transceiver Hot Pluggable, single LC, 1270nm/1330nm, DFB LD, Single Mode, 20km PSFP F/PSFP F

QSFP+ Passive Copper Cable QSFP-40G-0xC

Mb/s ATM Multi-mode Dual Transmitter

University of New Hampshire InterOperability Laboratory Ethernet Consortium

40 Gbit/s Small-Form Low-Power Optical Transceiver

UNH-IOL SAS CONSORTIUM

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

XFP 10G Transceiver M10GB-XFP-BIDI40

SHFP-GE-EX. 1.25Gb/s SFP Transceiver Hot Pluggable, Duplex LC, +3.3V, 1550nm DFB/PIN, Single mode, 40km, 0~70 C

UNH IOL iscsi CONSORTIUM

UNH-IOL NVMe Test Consortium

PCI Express Link Equalization Testing 서동현

N6468A SFP+ Electrical Performance Validation and Conformance Software

Agilent Technologies N5393A PCI Express Electrical Performance Validation and Compliance Software for Infiniium 54855A or Series Oscilloscopes

Parameter Symbol Min. Typical Max. Unit Storage Temperature T S C Supply Voltage V CC T, R V Relative Humidity RH 0 85 %

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

GP-XFP-1L-LEG. 10Gbs XFP Transceiver

Features. Description. Standard. Applications. RoHS Compliant 10Gb/s DWDM 80KM Multi-rate XFP Optical Transceivers OPXPDxx1X3CDL80

SHFP-GE-B Gb/s BiDi SFP Transceiver Hot Pluggable, Simplex LC/SC, +3.3V, Single mode, 80km, 0~70 C 1490/1550nm DFB/PIN

OpenFabrics Alliance

Siemon Interconnect Solutions

Copper SFP Series. 10/100/1000Mbps enable the auto-negotiation, preferred master 10/100/1000Mbps enable the auto-negotiation, preferred master

MECT Series Final Inch Designs in SFP+ Applications. Revision Date: August 20, 2009

Transcription:

Open Networking Testing Service UNH-IOL 21 Madbury Road, Suite 100 Durham, NH 03824 +1-603-862-0090 Joanna Deng May 14, 2018 10GTek Transceivers Co. Ltd Revision 1.1 xn_deng@10gsfp.com Enclosed are the results from the Open Network Systems Interoperability performed on: Module or Cable Assembly Under Test (MUT/CUT): Vendor and Device Type Part Number 10GTEK QSFP DAC 3M CAB-ZQP-ZQP-P3M Host Under Test (HUT): Host System 1 Composition Network Operating System Cumulus OS Version 3.5 Bare Metal Switch Edge-Core 7712 Part Number 7712 ONIE Version 2018.02 This testing pertains to the Open Network Systems Interoperability Test Plan, which outlines a series of tests performed on a variety of optical transceivers and cables with bare-metal open switches running Network Operating Systems from multiple vendors. The focus of these tests was basic interoperability, which aims to validate the operation of open network systems. As always, we welcome any comments regarding this Test Suite. If you have any questions about the test procedures or results, please feel free to contact me via e-mail at david@iol.unh.edu or by phone at +1-603-862-0090. Regards, David Woolf

Digital Signature Information This document was created using an Adobe digital signature. A digital signature helps to ensure the authenticity of the document, but only in this digital format. For information on how to verify this document s integrity proceed to the following site: https://www.iol.unh.edu/testing/reports/certificate-install If the document status still indicates Validity of author NOT confirmed, then please contact the UNH- IOL to confirm the document s authenticity. To further validate the certificate integrity, Adobe 6.0 should report the following fingerprint information: MD5 Fingerprint: 80 60 3C EA 42 D6 61 38 62 24 14 6A 1F 66 E9 84 SHA-1 Fingerprint: 81 FF 90 E8 56 CB 95 7F 3E D6 4D B8 B2 99 EF BE 3C CC 7D DE University of New Hampshire 2 Open Network Systems

In section 2, the following equipment was used: Test System Hardware EEPROM Reader I2C Elite Reader In section 3, the following equipment was used: Test System Hardware Network Analyzer PNA Performance Network Analyzer In section 4, the following equipment was used: Test System Hardware Wide Bandwidth Oscilloscope Waveform Analyzer 50GHz Waveform Analyzer Clock Recovery Module Keysight DCA-X 86100D Wide Bandwidth Oscilloscope Keysight 86105C Optical Waveform Analyzer Keysight 86108B Mega Module, 50GHz Bandwidth Waveform Analyzer Keysight 83496B Optical/Electrical Clock Data Recovery Unit High Performance Serial Tektronix BERTScope BERT Signal Quality Analyzer BERTScope PRBS9 at 10.3125Gbps De-Emphasis Signal Agilent N4916B Converter *Two modules used during testing In section 6, Ostinato software was used to generate test traffic: Test System Hardware Ethernet Traffic Generator Ostinato Software Version Ostinato Port Types 40/100G University of New Hampshire 3 Open Network Systems

The following table contains possible results and their meanings. Result W/ Comments FAIL INFO WARN N/A N/S N/T Interpretation The Device Under Test (DUT) was observed to exhibit conformant behavior. The specified behavior is demonstrated by the DUT; however this result indicates that either changes were made to the standard test procedure or results other than the expected results were observed. The DUT was observed to exhibit non-compliant behavior. This Test is designed for informational purposes only. While the results may help ensure the interoperability of the DUT, a /FAIL is not given for this test. The DUT was observed to exhibit behavior that is not recommended. Not Applicable. This test is not applicable for the DUT. Not Supported. This test was not run due to features not implemented on the DUT. Not tested. This test was not run. University of New Hampshire 4 Open Network Systems

Summary of Results- Conformance Test Test 1.1: ONIE Compliance Environment Test 1.2: Installing and uninstalling a NOS through ONIE via HTTP server Test 3.1.1: Return Loss for 10G Passive Cable Test 3.1.2: Insertion Loss for 10G Passive Cable Test 5.1.1: Output Rise and Fall Times for 100G Host Test 5.1.2: Transmitter Eye Mask for 100G Host Test 5.1.3: Total Jitter for 100G Host Test 5.1.4: Input and Output Return Loss on 100G Host Summary of Results - Interoperability Test Test 2.1: Physical Compatibility with Supporting Devices Test 2.2: Host Management of Module or Cable Assembly Test 2.3: Diagnostic Optical Monitor Support Test 6.1: Establish Baseline Performance Analysis Test 6.2: Link Detection on Power Up Test 6.3:Packet Error Rate Estimation Test 6.4: Packet Loss/Stress Test Result N/A Result Notes University of New Hampshire 5 Open Network Systems

Test 1.1: ONIE Compliance Environment Conformance s Purpose: To verify that a host can pass a random sampling of ONIE Compliance Environment tests. N/A The random sampling of tests from the ONIE Compliance Environment was not used. This test is only applicable to Hosts which have not performed ONIE compliance testing previously. Test 1.2: Installing and uninstalling a NOS through ONIE via HTTP server Purpose: To verify that a NOS can be successfully installed through ONIE. This test was completed using the standard procedure as written in the Test Plan. The random sampling of tests from the ONIE Compliance Environment was not used. Part A: The DUT was able to install the NOS via ONIE. Part B: The DUT was able to uninstall the NOS via ONIE. University of New Hampshire 6 Open Network Systems

Test 3.1.1: Return loss for 10G Passive Cable Purpose: To verify that the return loss of the DUT is within the conformance limits provided by SFF-8431 Appendix E, Table 37. This test was completed using the standard procedure. The differential return loss observed did not violate the limits governed by SFF-8431 Appendix E.4, Table 37 for 10GBASE-CR passive cables: 12 2 f, 0.01 f < 4.1 SDD11, SDD22 { f (db) 6.3 13 log 10, 4.1 f 11.1} 5.5 Test 3.1.2: Insertion Loss for 10G Passive Cable Purpose: To verify that the insertion loss of the Cable under test is within the conformance limits provided by IEEE Std. 802.3-2012 Annex, Table 37. This test was completed using the standard procedure. The insertion loss of the cable under test does not violate the requirements passive cable assemblies. 3dB SDD21, SDD12 17.04dB, at 5.15625 GHz University of New Hampshire 7 Open Network Systems

Test 5.1.1: Output Rise and Fall Times for 10G Host Purpose: To verify that the Eye Mask Hit Ratio is within the conformance limits. The test was completed with the standard procedure. The device under test exhibited the expected behavior. Test 5.1.2: Transmitter Eye Mask on 10G Host Purpose: To verify that the Eye Mask Hit Ratio is within the conformance limits. The test was completed with the standard procedure. The device under test exhibited the expected behavior. University of New Hampshire 8 Open Network Systems

Test 5.1.3: Total Jitter for 10G Host Purpose: To verify that the Total Jitter (TJ) is within the conformance limit. The test was completed with the standard procedure. The device under test exhibited the expected behavior. Test 5.1.4: Input and Output Return Loss on 10G Host Purpose: To verify that the differential input and output return loss of the DUT is within conformance limits. The test was completed with the standard procedure. The device under test exhibited the expected behavior. See Appendix B University of New Hampshire 9 Open Network Systems

Interoperability s Test 2.1: Physical Compatibility with Supporting Devices Purpose: To verify that the mechanical form factor is compatible with devices for interoperability purposes. The test was completed with the standard procedure. Part A: The MUT/CUT was able to be inserted into the Host. Part B: This test is not applicable to Cable Assemblies. Part C: The MUT/CUT was able to be removed from the Host. Test 2.2: Host Management of Module or Cable Assembly Purpose: To verify that the MUT/CUT is manageable via the Host complex. The test was completed with the standard procedure. Part B: The EEPROM data of the MUT/CUT was readable. The serial number and vendor information extracted from the EEPROM data matches the serial number and vendor information of the part. University of New Hampshire 10 Open Network Systems

Test 2.3: Diagnostic Optical Monitor Support Purpose: To verify that the MUT/CUT (active optical cable only) supports diagnostic functions via the Host complex. The test was completed with the standard procedure. Part A: The MUT/CUT supports diagnostic monitoring and the diagnostic information from the EEPROM was readable by the NOS. University of New Hampshire 11 Open Network Systems

Test 6.1: Establish Baseline Performance Analysis Purpose: To establish a baseline performance analysis of the HUT. This test was completed using a modified procedure. Because of a lack of 40G Golden Modules, the Host was baselined using each 40G MUT/CUT. The baseline performance of the Host was determined to be 90% line rate. All proceeding tests in Group 6 were conducted using this line rate. Test 6.2: Detection on Power Up Purpose: To determine if the MUT/CUT, HUT and LP establish a link while varying the power up sequence. This test was completed using the standard procedure. Part A: The Host and Link Partner were able to establish a valid link with this MUT/CUT while fully powered and operational. Part B: The Host and Link Partner were able to establish a valid link with this MUT/CUT when the Link Partner was powered on after the Host. Part C: The Host and Link Partner were able to establish a valid link with this MUT/CUT when the Host was powered on after the Link Partner. University of New Hampshire 12 Open Network Systems

Test 6.3:Packet Error Rate Estimation Purpose: To determine if a Host can exchange packets with a Module or Cable Assembly such that a bit error rate of 10-12 is achieved This test was completed using the standard procedure. Part A: All 247,000,000 frames transmitted by TS1 were received by TS2. Part B: All 10,506,539,320 frames transmitted by TS1 were received by TS2. Test 6.4: Packet Loss/Stress Test Purpose: To verify that no obvious buffer management problems occur when directing a large volume of traffic at the Host and Module/Cable Assembly combination. This test was completed using the standard procedure. Parts A-D: All 1,000,000,000 64-byte frames transmitted by TS1 were received by TS2. All 1,000,000,000 1518-byte frames transmitted by TS1 were received by TS2. University of New Hampshire 13 Open Network Systems

Appendix A: EEPROM Data 10Gtek QSFP28 module Part Number: CAB-ZQP-ZQP-P3M Serial Number: WTZ31HA0002 10Gtek WTZ31HA0002 EEPROMdecode_20180320202712.txt SERIAL_ID Keys: BR_NOMINAL: 25750 CONNECTOR: 33 CU_ATTENUATE_2_5: 0 CU_ATTENUATE_5_0: 0 DEVICE_TECH: 0xa0 ENCODING: 0 EXTENDED_MODULE: 0x1f EXT_IDENTIFIER: 0 EXT_RATE_COMPLY: 0 IDENTIFIER: 17 LENGTH_OM1_62_5UM: 0 LENGTH_OM2_50UM: 0 LENGTH_OM3_50UM: 0 LENGTH_OM4_OR_CU: 3 LENGTH_SMF_KM: 0 MAX_CASE_TEMP: 70 SPEC_COMPLIANCE: 0x80 0x0 0x0 0x0 0x0 0x0 0x0 0x0 VENDOR_NAME: 10Gtek VENDOR_OUI: 0x0 0x0 0x0 VENDOR_PN: CAB-ZQP-ZQP-P3M VENDOR_REV: 01 WAVELENGTH: 0.0 WAVELEN_TOLERANCE: 0.0 Vendor Specific: 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 I2C Address A0h, bytes 0-127, in hex 0000x: 11050600 00000000 00000000 00000000 0010x: 00000000 00001c5a 00008228 00000000 0020x: 00000000 00000000 00000000 00000000 0030x: 00000000 00000000 00000000 0000001c 0040x: 00000000 00000000 00000000 00000000 0050x: 00000000 00000000 00000000 00000000 0060x: 00000000 00000000 00000000 02000400 0070x: 00000000 00000000 00000000 00000000 I2C Address A0h, page 0, bytes 128-255, in hex 0000x: 11002180 00000000 00000000 ff000000 0010x: 000003a0 31304774 656b2020 20202020 0020x: 20202020 1f000000 4341422d 5a51502d 0030x: 5a51502d 50334d20 30310000 00004679 0040x: 0b000000 57545a33 31484130 30303220 0050x: 20202020 31373130 30312020 00006730 0060x: 00000000 00000000 00000000 00000000 0070x: 00000000 00000000 00000000 00000000 University of New Hampshire 14 Open Network Systems

Appendix B: Pluggable Module / Cable Electrical Data University of New Hampshire 15 Open Network Systems

Appendix C: Host Electrical Data University of New Hampshire 16 Open Network Systems

University of New Hampshire 17 Open Network Systems

University of New Hampshire 18 Open Network Systems