Introducing the world most advanced Shore/IRHD durometer DIGI TEST II
Modular design LOADING UNIT The whole system consists of 4 major modules, the loading unit, the measuring unit, the stand and the electronic unit The loading unit sits on top of the system and is electronically connected to the electronic unit. It applies the required load depending on the type of the test method ELECTRONIC UNIT MEASURING UNIT TEST STAND The measuring unit is fully interchangeable for the options of the entire Shore and IRHD ranges. It requires no complicated assembly and weighs from 0.4 ~ 1.7 kg The test stand stretches from top to bottom 570 mm and the solid construction provides the best stability for the entire system. This is the key for generating precise measuring results
For the complete Shore, IRHD and VLRH ranges The first and the only on the market. DIGI TEST II is the ultimate durometer with more than 20 different interchangeable measuring methods for materials of rubber, plastics, foams and gels. It takes not more than 10 sec changing from method to method.
A truly PLUG-N-PLAY system Changing the measuring method on digi test II is only about 3 simple steps and it can be completed in just 10 sec. ➀ Loosen the thumbscrew with your hand ➁ Plug/Unplug any measuring unit as desired and afterwards, tighten the thumbscrew ➂ Simply press Start to enable a hardness test
Making hardness test possible on concave and convex surfaces The conventional Shore A and Shore D tests require seamless contact of the presser foot and the specimen surfaces. This limits the possiblity of performing hardness tests on irregular shaped specimens. The Bareiss Shore A/B/0 can generate Shore A measuring results on irregular shaped specimens while the Shore D/C/D0 can generate Shore D measuring results. Continues to the next page Concave Surface Convex Surface Shore A/B/0 Shore D/C/D0
The Ø 18 mm presser foot With a built-in sensor to detect where the surfaces of the specimen are The specimen surfaces shall to be flat and even Shore A Requires seamless contact VS Requires contact only the tip of the indenter Shore A/B/0 The specimen surfaces do not require to be flat and even Go beyond conventional measuring requsites NO Ø18 mm presser foot required on the durometer NO limitations on the specimen with uneven surfaces NO limitations on small lateral dimensions of the specimen NO inconsistent measuring results caused by different measuring times, applied loads and angle of measuring
Making hardness test possible on specimens with material thickness under 6.0 mm As the standards DIN ISO 7619 and ASTM D 2240 describe that the test specimen shall be at least 6.0 mm in thickness, enough lateral dimensions to permit measurements at least 12.0 mm from any edge and at least 6.0 mm distance from measurement to measurement. With the Bareiss micro Shore A and micro Shore D 0.5 measuring technologies, we can generate micro Shore values which are comparable to the standard Shore values on specimen as thin as 0.5 mm. Continues to the next page micro Shore A micro Shore D 0.5
micro Shore A 62 41 67 69 Shore A 63 44 69 70 presser foot Ø 6 mm presser foot Ø 18 mm 0.5 mm 6.0 mm Penetration depth 0.2 mm Penetration depth 2.5 mm Micro Shore A vs Shore A The technology solely developed by Bareiss to generate comparable Shore A measuring values on specimens from as thin as 0.5 mm to the standard thickness. The solution is widely adpoted by many well-known customers in different industries. The measurements shown on this page are genuine data from STIHL the German manufacturer of different handheld power equipment
Introducing VLRH (Very Low Rubber Hardness) Co-developed with PTB the national metrology institute of Germany, VLRH is a proven hardness measuring method for supersoft elastomers or silicones. The digi test II with VLRH measuring unit conforms to the official standard DIN ISO 27588 How VLRH scale correlates to IRHD Normal and IRHD Low scales Some of the VLRH users VLRH
USB 2.0 connection to computer Universal Voltage 100 240 VAC 50/60 Hz Single cable connection to the main unit The electronic unit Run your digi test II with 3 simple cables. The universal voltage power supply requires no additional voltage converter. Easy USB connection to the computer for data transfer and only 1 single cable required for the communication with the main unit
System configurations of Test Mode, Measuring Time and Service System options of Language, Display Brightness, Audio Signal and Counter Reset Type of measuring method Test mode Display of measured value Indication of measuring range Indication of measuring time System status Large and simple display of information 4.3 inches screen
Configuration Mode Data output of one single measurement Data output of 10 measurements per second. Formation of a line graph Data output of peak measurement and actual measurement Time Service Select measuring time from 1 99 sec Enable SERVICE reminder message by setting number of test at interval of 1000 tests Reset the counter Option Language Brightness Buzzer Reset Counter Select language options of English, Italian, Spanish and French Adjust screen brightness from 0 99 % Switching On or Off the audio signal Overview and main reset of all counters
Your choice of using digi test II with or without PC digi test II can work as a standalone system as the electronic unit not only working as the main control of the system, it also provides basic testing information with its large LCD disply. When more sophisticated data analysis and making a test report are required, a PC in combination with Hardtest software can be considered. digi test II with PC and Hardtest Software digi test II as a standalone system
Hardtest (Release 1.00xx) Hardtest is a software which is developed for use with any of the Bareiss digital testers. The software provides a template for making a nice detailed test report, viewing measurements in graph line and histogram and setting upper and lower value limits. It is compatible with Windows XP, Vista, 7 and 8.
Barofix Suitable for O-rings with cord dia. 0.6 5.0 mm Centrofix Suitable for tubes and hoses Multifix Suitable for irregular shaped rubber parts Multifix II Suitable for rubber sealings Barofix II Fully automatic for less operator s errors Sealfix Suitable for different sizes of oil seals Rotofix For multiple circular shaped samples. Automatically operated Different designs of specimen fixtures
The national DAkkS calibration certificate Bareiss with the registration number D-K-15206-01-00 became the first DAkkS (formerly known as DKD) accredited certification body for Shore and IRHD in Germany in 1996. This calibration certificate is to ensure your instrument is delivered with the highest quality and measuring precision.
20 cm 25 cm Technical Specifications Power Supply 100 240 VAC ; 50/60 Hz Power Consumption Max. 20 VA 57 cm IP Code 20 Display LCD 240 x 128 Pixel Resolution 0.1 Data Output USB / RS 232 Measuring Time 1 99 sec 26 cm 26 cm 11 cm Weight: 14 kg Weight: 2.5 kg Weight and Dimensions The complete digi test II system weighs not more than 25 kg and stands not more than 60 cm tall. Its compact size and light weight don t compromise the robustness of the structure. 80 % of the system is made of high quality aluminum alloys.
All the available Shore scales (continues to the next page) Type Indenter Sample Thickness Standard Application A 4 mm / 6 mm DIN EN ISO 868 DIN ISO 7619 ASTM D 2240 NFT 51-174 BS903 Part. A26 Micro A 0.5 mm BAREISS A0 6 mm DIN ISO 7619 ASTM D 2240 B 6 mm ASTM D 2240 0 6 mm ASTM D 2240 C 6 mm ASTM D 2240 D 4 mm / 6 mm DIN EN ISO 868 DIN ISO 7619 ASTM D 2240 NFT 51-174 BS903 Part. A26 Micro D N/A 0.5 mm BAREISS D0 6 mm ASTM D 2240 00 6 mm ASTM D 2240 000 6 mm ASTM D 2240 000S 6 mm ASTM D 2240 E 6 mm DIN ISO 7619 ASTM D 2240
Type Indenter Sample Thickness Standard Application AM 1.5 mm DIN ISO 7619 M 1.5 mm ASTM D 2240 All the available IRHD and VLRH scales Type Indenter Sample Thickness Standard Application Micro Normal 0.6 mm 6 mm DIN ISO 48, ASTM D 1415, NFT 46-003, BS 903 Part. A 26 DIN ISO 48, ASTM D 1415, NFT 46-003, BS 903 Part. A 26 Hard Low 6 mm 6 mm DIN ISO 48, ASTM D 1415, NFT 46-003, BS 903 Part. A 26 DIN ISO 48, ASTM D 1415, NFT 46-003, BS 903 Part. A 26 Type Indenter Sample Thickness Standard Application VLRH 2 mm DIN ISO 27588
Heinrich Bareiss Prüfgerätebau GmbH DAkkS/DKD-Kalibrierlaboratorium Breiteweg 1 DE-89610 Oberdischingen Germany www.bareiss.de I info@bareiss.de Tel: +49 (0) 7305 / 96 42-0 Fax: +49 (0) 7305 / 96 42-22 Bareiss Shanghai Limited. Room 2002, No. 248 Yang Shu Pu Road, Hongkou District, Shanghai 200082 China www.bareiss.cn I china@bareiss.de Tel: +86 21 6887 5055 Fax: +86 21 6887 5055