SIMRAD GB60 Glass Bridge system

Similar documents
Simply point and choose

Specifications: TECDIS 2424

Manual. Simrad IS70/IS80 RPM Indicators RPM70 and RPM80 Speed Indicators SP70 and SP80. English

JMA-1030 Radar. the JMA-1030 is an easy to use radar that greatly supports your ship's handling by touch operation. since 1915

Manual. Simrad IS70/IS80 Rudder Indicators RI70 and RI80. English

Installation manual. Simrad AP24/28 EVC, Volvo IPS Pilot System with SG05 SimNet-Volvo Gateway. English

R5000 Radar processor Installation Manual

Specifications: TECDIS 2728

ECHOMAP PLUS 40 SERIES Installation Instructions

Manual. Simrad GB40 Integrated Network System. English Sw. 4

Vulcan. Getting Started ENGLISH. bandg.com

TECHNICAL INFORMATION

ikommunicate NMEA - SignalK Gateway

OPERATOR MANUAL. SIMRAD CS68 ECDIS Chart System

GN70/MX610/MX612 QuickStart Guide

Specifications: TECDIS 2138 B

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com

GO XSE. Getting Started. simrad-yachting.com ENGLISH

TECHNICAL INFORMATION

OCEAN 7T. Technical presentation (ENGLISH) FURUNO ELECTRIC CO., LTD. All Rights Reserved.

QK-A032 NMEA 2000/0183 Bi-directional Converter

Operator's Guide FMD-3200/FMD-3200-BB/FMD-3300

QK-A031 NMEA 0183 Multiplexer with SeaTalk Converter Features

echomap CHIRP 70/90 Series

Simrad Marine Electronics. Setup and Commissioning Instructions for Boatbuilders and Dealers

IS40/Triton System Installation Manual

SGW1-MB-NM User s Manual

NAV6 enavtex System (with and without antenna) Installation and Quick Start Guide

CS68 ECDIS Operator Manual ENGLISH

PI3000. User Guide PASSENGER INFORMATION SYSTEM. rev 1.2

Network Video Recorder Quick Operation Guide

RC-SV Configuration Guide Revision 3

Lionstracs Groove X-R

RC-SV Configuration Guide (Rev 4)

INSTRUCTION MANUAL VDR MAINTENANCE VIEWER

DATA MULTIPLEXER DM24

Manual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

GN70. Operator and Installation Manual ENGLISH

B&G LCD CHART USER S GUIDE AND INSTALLATION HB

ZOTAC ZBOX User s Manual

Maris ECDIS900 Backup/ Restore Procedures for SW 4.7.x.x and 4.8.x.x. User Guide ENGLISH. navico-commercial.com

Feature Guide: TECDIS 4.7.x.31

Manual. Navico SW Upgrade Tool. English.

DSC-N114_Network_Video_Recorder

Quick Installation Guide

MOSS-DVR-810 Mobile Digital SD Recorder User Manual

Chapter 14: Controlled Remote Tug Telemetry

CAMit I Camera with built in Modem

MEDALLION INSTRUMENTATION SYSTEMS MasterCraft Viper system

2190 POS System User Guide

FMD-3200/FMD-3200-BB/FMD-3300

Installing the Cisco Unified Videoconferencing 3545 MCU

700TSU INSTALLATION MANUAL

Network Video Recorder Quick Operation Guide

Hybrid DVR Quick Start Guide

GpsSimul User Guide 1. GpsSimul User Guide. User guide. (c) 2012 Sailsoft

ZOTAC ZBOX User s Manual

Feature Guide: TECDIS 4.7.x.30

Zeus 2 Glass Helm QuickStart Guide

IS40 PRO. Operator Manual ENGLISH

GO XSE. Getting Started. ENGLISH

Industrial Serial Device Server

Network Transmission System

ZOTAC ZBOX User s Manual

Quick Setup & Getting Started

Quick Start: GeoDAS-LT with Single Beam Echo Sounder

ZOTAC ZBOX. User s Manual

PowerView Model PV750. Installation and Operations Manual Section 78

8-Port / 16-Port KVM SWITCH User s Manual

2100 POS System User Guide

Hook2 X Series. Operator Manual. 4x GPS, 4x Sonar, 5x GPS HDI, 7x GPS HDI ENGLISH

ZOTAC ZBOX User s Manual

DigiSoft GmbH & Co. KG Waldstrasse 7 * D Berg USER MANUAL

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

APPLICATION NOTES. HEADING INDICATOR SYSTEMS using XDi-N indicators. Document no.: A

Teledyne PDS. Trailing Suction Hopper. Version April Teledyne RESON B.V. Stuttgartstraat AS Rotterdam The Netherlands

705 INSTALLATION MANUAL

ECI1. COMPASS display. ECI1-REV For latest update: Electronic Compass Indicator ECS1

The paper used in this manual is elemental chlorine free.

SNMP Web Management. User s Manual

Quick Installation Guide

Hardware Installation Guide Installation (x3350)

CONTENTS SETTING THE TIMERS AND LAP TIMER...18

2 Mega-Pixel H.264 Box IP Camera ICA-HM125. Quick Installation Guide. Version 1.0

291-MB333-04P7F EN1070K

Explorer 3 w/o GPS antenna Multifunction chartplotter

R5 SOLID Secure W-AIS Transponder System

3700 SERIES USER MANUAL

ZOTAC ZBOX User s Manual

GKH TR11 AUTOMATIC TRAIN UNDERCARRIAGE INSPECTION SYSTEM

Ctdigi.com. Instruction manual. Production by S & W Technology Labs

Startup Guide C01

NGW-1. NMEA 2000 to NMEA 0183 Gateway. User Manual

ZOTAC ZBOX nano User s Manual

291-MB309-02N6F. PI331 pico

FICE-100 Ice Radar FOIL-200 Oil Radar

ZOTAC ZBOX User s Manual

LENOVO IDEACENTRE A310

Chart Plotter USER MANUAL

Transcription:

INSTALLATION MANUAL SIMRAD GB60 Glass Bridge system 20222444/B English

2006 by Navico Egersund AS All rights reserved. No part of this document, including cover design, may be reproduced or otherwise copied without prior written permission of Navico Egersund AS. The information contained in this document is subject to change without prior notice. Navico Egersund AS shall not be liable for errors contained in this document.

INSTALLATION MANUAL About this manual This manual is a reference guide for installing the Simrad GB60 GlassBridge System. In this manual, names of dialog boxes, menu commands and menu buttons are written in boldface (e.g. Navigation menu, Edit command, OK button). References to buttons on the keyboard and on the optional operator panels are written in boldface, but in a different text style (e.g. F9 button). Important text that requires special attention from the reader is emphasized as follows: Used to draw the reader s attention to a comment or some important information. Used when it is necessary to warn personnel that a risk of damage to the equipment or injury/death exists if care is not exercised. Sections The document includes the following sections: 1 Installation Description for unpacking and handling the equipment, for mechanical and electrical installation of all units in a GB60 system 2 System setup How to set up a GB60 system with multiple monitors, a GB60 GlassBridge network, and the radar input ports. 3 Software configuration How to configure the GB60 software 4 Installing charts How to install charts on the GB60 system 5 Backup and Restore procedures Back-up and restore procedures for the GB60 software 6 Spare parts Part numbers for all standard and optional units that may be included in a GB60 system. 7 Technical specifications Hardware specification for all units included in a GB60 system. 8 Drawings Drawings, diagrams and cut-out templates for units in a GB60 system. 20222444 / B ii

Simrad GB60 THIS PAGE INTENTIONALLY LEFT BLANK iii 20222444 / B

INSTALLATION MANUAL Contents 1 INSTALLATION...1 1.1 System components...2 1.2 Unpacking and handling...3 1.3 Location of the units...3 1.4 Mechanical installation...3 1.5 Grounding the units...6 1.6 GB60 BB terminal layout...7 1.7 Cable connection...8 1.8 Power connection...8 1.9 Internal cable connections...9 1.10 Connecting optional equipment...11 1.11 Connecting external equipment...12 1.12 Network connections...15 2 SYSTEM SETUP...17 2.1 System Settings dialog...18 2.2 Changing the display setup...19 2.3 Setting the IP addresses in a network...21 2.4 Configuring the radar input ports...23 3 SOFTWARE CONFIGURATION...25 3.1 General...26 3.2 The Option dialog...26 3.3 Configuring the input ports...28 3.4 Configuring the output ports...30 3.5 Port priorities...31 3.6 Radar configuration...32 3.7 Network configuration...34 3.8 Identifying the video inputs...37 4 INSTALLING CHARTS...39 4.1 The Permit code...40 4.2 Obtaining a permit code...41 4.3 Installing the charts...41 5 BACKUP AND RESTORE PROCEDURES...45 5.1 General...46 5.2 Making a backup...46 20222444 / B iv

Simrad GB60 5.3 Restoring the software...47 6 SPARE PARTS...49 6.1 Main components...50 6.2 GB60 Keyboards, Trackballs and Operator panels...50 6.3 Accessories...50 6.4 GB60 Optional equipment...51 6.5 GB60 GlassBridge monitors...52 7 TECHNICAL SPECIFICATIONS...53 7.1 Cable lengths...54 7.2 GB60 Black Box...55 7.3 DVD Module...55 7.4 KM60 Keyboard and Mouse (Option)...56 7.5 GB60 Armrest CU (Option)...56 7.6 PD60 Pointing device (Option)...57 7.7 COP20 Operator Panel (Option)...57 7.8 NMEA support...58 8 DRAWINGS...61 8.1 Drawings overview...62 8.2 GB60 Black Box, Top view...63 8.3 GB60 Black Box, Back view...64 8.4 GB60 Black Box, Side view...65 8.5 GB60 DVD module, Dimensions...66 8.6 KM60 Keyboard/Mouse, Dimensions...67 8.7 GB60 Armrest CU remote unit, Dimensions...68 8.8 PD60 Pointing device, Dimensions...69 8.9 COP20 Operator Panel, Dimensions...70 8.10 GB60 Cabling diagram...71 v 20222444 / B

INSTALLATION 1 INSTALLATION This section holds descriptions for unpacking and handling the equipment, and for mechanical and electrical installation of all units in the GB60 system. 20222444 / B 1

Simrad GB60 1.1 System components The GB60 system includes the following units: GB60 BB (Black Box) DVD module Color monitor (may be supplied by others) Keyboard and mouse (may be supplied by others) Keyboard and mouse may be replaced with a KM60 or a COP20, including both a keyboard and a pointing device. The basic system may be expanded with a GB60 Armrest CU remote panel and with a PD60 Pointing device. Optional equipment Units that may be delivered by others 2 20222444 / B

INSTALLATION 1.2 Unpacking and handling Care should be taken when unpacking and handling the equipment. A visual inspection should be made to see that the equipment has not been damaged during shipment and that all components and parts are present. 1.3 Location of the units The units included in the GB60 system should be mounted with special regard to the units environmental protection, temperature range and cable length. The GB60 units are designed to operate within the temperature range of 0 C to +55 C. However, it is highly recommended that adequate ventilation/air-conditioning is provided in order to keep the ambient operating temperature at +20 C. It is also recommended that the area around the units is kept relatively free from dust and build-up static electricity. 1.4 Mechanical installation GB60 BB The GB60 BB has to be mounted horizontally, and should not be installed close to heavy transformers or similar. Other equipment should not be stored upon the unit. 20222444 / B 3

Simrad GB60 When running, the GB60BB emits 200W/h. As the working temperature for the unit must be kept below 50 C (32 F), it is strongly recommended to connect the mounting area to the vessel s air conditioning system. It is necessary to have working area when replacing the air inlet fans dust filter. Refer dimensional drawing showing recommended working area, page 61 onwards. DVD module The DVD module should be mounted horizontally. Secure the unit with four 4mm screws as indicated in the figure below. Refer dimensional drawing page 66, and the enclosed drilling template. 4 20222444 / B

INSTALLATION GB60 Armrest CU (Option) GB60 Armrest CU is designed for panel mounting. The unit is secured to the panel with four 4mm screws as indicated in the figure below. Refer dimensional drawing page 68, and the enclosed drilling template. PD60 Pointing device (Option) The unit is secured to the panel with four 4mm screws as indicated in the figure below. Refer dimensional drawing page 69, and the enclosed drilling template. 20222444 / B 5

Simrad GB60 1.5 Grounding the units GB60 BB and the DVD module should have a proper ground connection from the units ground terminal. The wires should be as short as possible and have a cross section of at least 16mm 2 (gauge). GROUND TERMINAL 6 20222444 / B

INSTALLATION 1.6 GB60 BB terminal layout The figure on the next page shows GB60 BB terminal layout. Ports not used by the system are grayed, and ports used for internal termination are shown hatched. ETHERNET 24V DC POWER RSI PS2 SIMNET DVD MODULE USB COM 3 4 6 5 1 VGA MONITOR S-VIDEO 3 DVI 2 MONITORS CAMERAS 20222444 / B 7

Simrad GB60 1.7 Cable connection To avoid that vibration should cause the plugs to lose connection, it is recommended to attach the cable to the fixing devices on GB60 BB and the DVD module with a wire strip. 1.8 Power connection The GB60 BB and the DVD module should be supplied with 24V DC. GB60 BB Connect the power cable via a 10 Amp fuse to the plug supplied with the equipment according to the terminal labeling shown below. - DVD Module Connect the power via a 3 Amp fuse to terminal 6, 7 and 8 on the plug supplied with the equipment. TERMINAL NO SIGNAL 6 + 7-8 GND 8 20222444 / B

INSTALLATION 1.9 Internal cable connections DVD Module GB60 BB Connect the DVD module to GB60 BB with the 2 supplied cables. The screen should be terminated to the ground terminal on GB60 BB and to pos 5 on the DVD plug. GB60BB DVD MODULE PART OF GB60BB PART OF DVD MODULE 1 2 3 4 1 2 3 4 24V POWER SUPPLY 1 2 3 4 1 2 3 4 5 6 7 8 ON/OFF + - + - GND USB 20222444 / B 9

Simrad GB60 Monitor(s) GB60BB includes 1 VGA and 2 DVI ports. DVI/VGA converters may be used to connect VGA plugs to the DVI ports. When using multiple monitors, the monitors are identified in software when the system is configured. It is however recommended that the monitors are connected in a logical order. MONITOR #1 MONITOR #2 MONITOR #3 1 VGA MONITOR 3 2 DVI MONITORS Refer Changing the display setup, page 19. Standard keyboard and mouse A standard keyboard and mouse may be used for operating GB60. The units should be connected to the PS2 Keyboard/Mouse ports on GB60 BB, or to one of the USB ports on GB60 or the DVD module. 10 20222444 / B

INSTALLATION 1.10 Connecting optional equipment KM60 An optional KM60 may be used to replace standard keyboard and mouse in the GB60 system. The unit is connected to the PS2 Keyboard and Mouse ports on GB60 BB, or to one of the USB ports via a PS2/USB converter. PS2 / USB KM60 USB PART OF GB60 BB PS2 KEYB. PS2 MOUSE GB60 Armrest CU Optional GB60 Armrest CUs may be connected to the system in addition to standard keyboard/mouse or the KM60. The male plug on the armrest unit is connected to a PS2 port on GB60 BB, or the unit could be connected between a PS2 keyboard (or keyboard plug KM60/COP20) and GB60 BB as illustrated below. GB60 ARMREST CU KEYBOARD PART OF GB60 BB PS2 KEYB. PD60 Pointing device The PD60 is connected to any of the USB ports on the GB60 BB or the DVD module. 20222444 / B 11

Simrad GB60 COP20 Operator panel An optional COP20 may be used to replace standard keyboard and mouse in the GB60 system. The unit is connected to the PS2 Keyboard and Mouse ports on GB60 BB, or to one of the USB ports via a PS2/USB converter. PS2 / USB COP20 USB PART OF GB60 BB PS2 KEYB. PS2 MOUSE 1.11 Connecting external equipment NMEA devices 1 optical isolated NMEA converter is included in the GB60 system. This must be used for connecting external equipment to a com port on GB60 BB. Connect the cable to external equipment according to the manufacturer s specification and according to the table below. COM 3-6 SIGNAL NAME RX + RX - TX + TX - GND COLOR Yellow Red Green Blue Braided screen The supplied NMEA converter includes opto isolation and active components inside the connector house. No external equipment must be connected to the serial ports without using an NMEA converter. The cables can only be replaced with cables ordered from Simrad! (part no. 26049759) 12 20222444 / B

INSTALLATION SimNet equipment GB60 may be interface to equipment communicating on SimNet (Simrad Intelligent Marine Network) data network. SimNet equipment PART OF GB60 BB SimNet 12V DC Power supply To other SimNet equipment or end terminal The manual following the SimNet equipment has a detailed description of how to connect the units. If necessary, a separate SimNet Installation manual (part no. 20222006) could be ordered from a Simrad dealer. The manual is also available on Simrad s web pages (www.simradyachting.com). Video input (Option) Up to 4 devices with a composite video output can be connected to a GB60 VSI and GB60 VSI&RSI system via the Video input ports on GB60 BB. The devices may be connected to any of the 4 video input ports, and the connection sequence is irrelevant. Video signal is not shared on a network. The video device and the monitors that should be set up with a video view must be connected to the same GB60 BB! 20222444 / B 13

Simrad GB60 Radar(Option) GB60 system is designed to receive input from RA60 series radar or from a stand-alone radar with remote station output (Radar Signal Interface, RSI). The RSI port is only available on the GB60 RSI and GB60 VSI&RSI systems! Each GB60 BB may be interfaced to two RA60 series radars using the Ethernet network ports, or to one stand-alone radar connected to the RSI port. RA60 radars can not be mixed with an RSI radar input on the same GB60 BB. Two GB60 BBs must be networked to achieve this configuration! Refer the radars separate Installation Guide for how to physically connect these radars to GB60 BB. It is strongly recommended to use a qualified marine technician to install all radar hardware. RSI connector pinout A D-SUB connector is included in the GB60 RSI system. This should be used for connection a radar to the RSI port on GB60 BB. The figure below shows RSI connector pinout and recommended termination in the radar. 1 Video - 2 Video + 3 Trigger - 4 Trigger + 5 BP - 6 BP + 7 SHM - 8 SHM + EXTERNAL RADAR Video GND Video Trigger BP SHM GND 14 20222444 / B

INSTALLATION 1.12 Network connections Up to 4 GB60 BBs may be connected in a GlassBridge network. By using this option, charts and data from external equipment could be shared across the network. Video signal is not shared on the network. The video device and the monitors that should be set up with a video view must be connected to the same GB60 BB! An Ethernet network switch is included in the GB60 BB, and no hub is required. The computers are connected from one computer to the other by using a Cat5 network cable between the Ethernet ports on GB60 BB. It is essential to not connect the cables so that a circle is created. This will result in a Network storm and the network will be useless! Before the computers are connected, each GB60 BB must be set up as described in Setting the IP addresses in a network, page 21. 20222444 / B 15

Simrad GB60 THIS PAGE INTENTIONALLY LEFT BLANK 16 20222444 / B

SYSTEM SETUP 2 SYSTEM SETUP This section described how to set up a GB60 system with multiple monitors, a GB60 GlassBridge network, and the radar input ports. 20222444 / B 17

Simrad GB60 2.1 System Settings dialog System setup and maintenance is performed by using the System Settings dialog. This dialog is only accessible at startup. Use the following procedure to display this dialog: 1 Start/restart the GB60 system 2 When the Simrad dialog is displayed, press the System settings button The System Settings dialog is displayed within few seconds The following options are available: Text Description Ref page: Data Management Restore to Factory Settings Installer Setup Write Log Files to Memory Stick View Startup Log Install WF30 Charts / Software updates Deletes data and charts Restores all settings to default values Used for configuring display, network and external devices Copies all log files to a memory stick connected to the USB port on front of the DVD module Displays the startup log Button text depending on the CD/DVD in the DVD reader. Installation of WF30 charts 41 Software updates are described in the separate GB60 Operator manual. 17 18 20222444 / B

SYSTEM SETUP Displaying the Installer Setup dialog The display, network and external devices are all configured from the Installer Setup dialog. 1 Press the Installer Setup button in the System Settings dialog 2 Enter 1234 in the Installer Setup Password dialog The Installer Setup dialog will be displayed: 2.2 Changing the display setup The Display Properties dialog is displayed by pressing the Display Setup button in the Installer Setup dialog. PART OF INSTALLER SETUP DIALOG 20222444 / B 19

Simrad GB60 Setting the monitors arrangement If multiple monitors are used in the GB60 system, the monitors should be connected according to their physical arrangement. If this is impossible, the setting could be changed by pressing the Settings tab in the Display Properties dialog. Drag the monitor icon to match the cursor movement as illustrated below. When monitor no.2 is active, the cursor should appear on monitor no.1 when the cursor is moved left and out of monitor 2, and should appear on monitor no.3 when the cursor is moved right. MONITOR (1) MONITOR (2) MONITOR (3) The Identify button will test the settings before it is finally approved by pressing the Apply or OK button. 20 20222444 / B

SYSTEM SETUP Defining the main monitor The monitor located at the main operator station has to be defined as the main monitor. By default the system will consider the monitor connected to monitor port no.1 as the main monitor. If another monitor is located at the operator station, this monitor is setup as main by selecting the monitor icon and checking the Use this device as primary monitor option in the Settings dialog. 2.3 Setting the IP addresses in a network Up to 4 GB60 BBs may be connected in a GlassBridge network, and the computers are recognized by unique IP addresses. The table below shows an example where the IP address is increased by one for each computer, while the Subnet mask is identical. BLACK BOX no IP ADDRESS SUBNET MASK 1 192.168.0.10 255.255.255.0 2 192.168.0.11 255.255.255.0 3 192.168.0.12 255.255.255.0 4 192.168.0.13 255.255.255.0 The IP addressed are set as described below: 1 Display the System Settings followed by the Installer Setup dialogs as described in page 19 onwards 20222444 / B 21

Simrad GB60 2 Press the Network Setup button The Network Connections dialog will be displayed 3 Right-click on Local Area Connection, and select Properties 4 Select Internet Protocol (TCP/IP), and press the Properties button 5 Select Use the following IP address, and enter an IP address and a Subnet mask as proposed in the table in page 21. Leave the other fields empty 6 Repeat for all GB60 BBs in the GlassBridge Network The settings will not take effect before the system is restarted! 22 20222444 / B

SYSTEM SETUP 2.4 Configuring the radar input ports GB60 is configured to the radar(s) by using the Radar setup wizard. For advanced radar settings, refer to the separate radar Installation manual. Make sure that the radar(s) are powered on and connected to GB60 BB prior to running the Radar setup wizard. If the system includes a GlassBridge network, each GB60 BB connected to a radar needs to be configured separately before the network is connected! Use the Radar setup wizard as follows: 1 Display the System Settings followed by the Installer Setup dialogs as described in page 19 onwards 2 Select Yes in the Step 1 field if the radar is connected to the RSI port on GB60 BB 3 Press the Run Radar Setup Wizard button, and follow the instructions on the screen 4 When the radar connections are found, press the Next button to display the Radar Status dialog. The radar(s) may now be renamed by pressing the Rename Selected Radar button 20222444 / B 23

Simrad GB60 5 Press the Next button to adjust the radar image. It may be necessary to wait up to 3 minutes while the radar warms up. Once the radar is transmitting data, the Radar Viewer section in the Adjust Radar Image dialog will indicate how the radar will appear on the screen. 6 Click Adjust to open the Radar Control dialog. Use this dialog to modify your radar settings and improve radar viewing It may take a few minutes for the changes to be applied 7 Click the Next button when the radar appearance is accepted 8 The radar wizard is now completed, and the setup is confirmed by pressing the Finish button 24 20222444 / B

SOFTWARE CONFIGURATION 3 SOFTWARE CONFIGURATION This section describes how to configure the GB60 software. 20222444 / B 25

Simrad GB60 3.1 General The GB60 system is configured when delivered from Simrad, and should normally only need to be configured to external devices connected to the system. 3.2 The Option dialog All configuration of the GB60 system is done from the Options dialog. This dialog is the entrance to all settings that have to be done when configuring the system. The Options dialog is only accessible from an active Nav or Radar window. To avoid unintended alteration of system parameters, the Options dialog is password protected. Use the following procedure to open the dialog: 1 Click the right mouse button in an active Nav or Radar window, and select the Options command A dialog will request a password before it is possible to enter the system configuration 2 Enter 1234 in the password field to get access to the Options dialog Data entered in the Options dialog are not taken into account until it is confirmed by clicking the OK or APPLY buttons: APPLY: changes are applied, and the dialog box remains displayed. OK: changes are applied, and the dialog box is removed from the display 26 20222444 / B

SOFTWARE CONFIGURATION The settings in the different tabs in the Options dialog have all clear and self-explanatory text, and only a few tabs are therefore described here. Description Ref page: Ports: Configure: External equipment configuration 28 Port Priorities Priority settings for devices sending equal information 31 Radar Weather Units Misc. Colors Audio 3D/Bathy Depth Contours Targets GlassBridge Network Data Sharing Radar settings Relative bearing settings for apparent and theoretical wind angle Units of measurement for speed, depth/length, volume, distance and temperature. Available options are metric, nautical and US units of measure Miscellaneous settings. Most options available as Yes (enable) or No (disable) Color settings for routes, boundaries and ranges/bearings Audio report settings used for providing periodic, verbal reports about any of the selected data types Settings for 3D and bathymetric window appearance Depth and contour settings used for 2D charts MARPA and AIS target options Settings required when the GB60 includes a GlassBridge network Video Video identification 37 32 35 20222444 / B 27

Simrad GB60 3.3 Configuring the input ports The input/output com ports are configured from the Ports: Configure tab in the Options dialog. If several GB60BBs are connected in a GlassBridge network, each GB60BB has to be configured separately before the network cable is connected. In addition to port selection and buttons, the Ports: Configure tab includes the following options: TEXT Require Valid Checksums on all Sentences Require Checksums to be Valid if Present Report Checksum Discrepancies Ignore Invalid GPS Position Data Detect GPS MOB Detect MOB hardware Log All Input Log All Output DESCRIPTION If this option is enabled, the software will ignore any data that does not contain a valid checksum. Equipment conforming to previous versions of NMEA0183 specifications do not always use checksums in all data sentences. Verifies validity of sentences which contain checksums, but accepts sentences which do not contain checksums. Alerts if a checksum error is found. Ignores invalid data from the GPS receiver. Used to detect externally connected hardware. Used for debugging and problem solving. 28 20222444 / B

SOFTWARE CONFIGURATION Using the GPS/Ports Setup Wizard It is recommended to use the setup wizard whenever a device is connected to the GB60 system. This option will search for any NMEA device that is installed and powered on. If a radar is connected to the GB60 system, the unit should be setup and configured as described in Configuring the radar input ports, page 23 onwards. The wizard is started by pressing the GPS/Port Setup Wizard button in the Options dialog. Follow the instructions on the screen to complete the setup wizard. Manually configuring the input COM ports If required, the input ports may be manually configured as follows: 1 Select the Ports: Configure tab in the Options dialog 2 In the Input Ports list, select the COM port(s) to use. Error messages will display if the port is unavailable or improperly configured. 3 Select a COM port and then press the Configure This Input Port button to display the port s Input Configure dialog 4 Select input options and port speed 5 Click the OK to confirm the settings and close the dialog 20222444 / B 29

Simrad GB60 3.4 Configuring the output ports To communicate with different external devices, GB60 contains a number of available information settings. Consult with the device s manual to verify what information needed for communication with GB60. Use the following procedure to configure the output ports: 1 Select the Ports: Configure tab in the Options dialog, and select the port used for the device 2 Click the Configure All Output/Autopilot Ports button to display the Configure Output/Autopilot Settings dialog 3 In the Update Interval field, specify how often control data should be sent to the device 4 Specify bearing output, precision and toggle on other required settings 5 Select NMEA strings to be sent to the device 6 Enter the talker identification to be used to identify the GB60 to the device 30 20222444 / B

SOFTWARE CONFIGURATION 7 Click OK to save the settings 8 Test the device and change the settings if needed 9 Document the settings for future reference 3.5 Port priorities If two or more devices send redundant information to GB60, the system will automatically select the device sending the information with highest resolution. It is however possible to manually prioritize the devices from the Port Priorities tab. The Port priority is set as follows: 1 Select the Port Priorities tab in the Options dialog 2 Click the Add button. The Add Device dialog box will display 3 Select Port, Device, and Data Type, and enter a Time Out value 4 Prioritize each position device in the same manner. Multiple devices may connect to the same port if they have different NMEA Talker ID s 5 Close the dialog and return to the Port Priorities dialog by pressing the OK button 6 Click the up or down arrows to place device entries in order, with the highest priority device at the top of the list 20222444 / B 31

Simrad GB60 3.6 Radar configuration The target settings are defined in the Targets tab. The following parameters are available: Parameter Display ARPA Targets ARPA targets based on magnetic Display AIS Targets Display targets on radar display Display DSC Targets Target Name Settings Display Predictors Display Wakes AIS/ARPA Target Timeouts DSC Target Timeouts Description Turns ON/OFF the displaying of ARPA targets Defines if a magnetic heading sensor is connected to an external radar Turns ON/OFF the displaying of AIS targets Turns ON/OFF targets on the GB60 radar window Turns ON/OFF the displaying of DSC targets Defines how the target name will be displayed on the chart Displays a course predictor line in minutes for all detected targets Displays a historical track of where the target has been Selects how long an AIS/ARPA target will remain on the chart after it is lost Selects how long an DSC target will remain on the chart after it is lost Target Threat Settings Target alarm settings. Refer Target alarms, page 33 DSC Directory Used to assign names to the DSC targets 32 20222444 / B

SOFTWARE CONFIGURATION Target alarms The Target Threat Settings button in the Targets tab (Options dialog) gives access to settings defining when a target should be considered as dangerous. When Detect Threats option is turned on, the GB60 will detect potential threats based on information received from the targets. A target will be considered as a threat if it is within the limits set for CPA (Closest Point of Approach) or TCPA (Time to Closest Point of Approach). When a target becomes a threat, the symbol will change to a red triangle, and a flashing target alarm symbol will appear in the lower left part of all chart and radar windows. If selected, an audible alarm will also be activated. 20222444 / B 33

Simrad GB60 3.7 Network configuration Configuring the input devices Each GB60 BB that is directly connected to a NMEA0183 sensor device (GPS, etc.) needs to be configured separately to receive this information. This configuration has to be performed before the GB60 BB is connected to the network. See Configuring the input ports page 28 for more information. Enabling the network This settings described below must be selected on each GB60 system that should share data. 1 Disconnect all GB60 BB from the network and start each separate GB60 system 2 Verify that each installation is working properly 3 Connect all computers to the network 4 Select the GlassBridge Network tab in the Options dialog The network identity will default to the name of the GB60 BB. A new name may be entered if required 5 Click Enable Advanced Networking 6 Click Accept Active Waypoints from other Computers Whenever another station creates or moves an active waypoint, this station will update accordingly 7 Chose one of the Chart Sharing options (Ask, Yes or No) Ask will prompt the user each time the GB60 BB is started whether or not to share charts. Yes will share all Passport charts each time the program opens and No turns chart sharing off 34 20222444 / B

SOFTWARE CONFIGURATION 8 Check Share Radar Targets if appropriate 9 Check Routes and Marks Home-location for all Nav Objects on the GB60 BB that will be the server for the other GB60 BBs on the network 10 Select one of the options for Accept Nav Objects From Other Stations (Prompt or Accept All) 11 Repeat steps 4-9 to configure each GB60 BB The settings will not take effect before the system is restarted! Data sharing Two types of data that can be shared on the network: Processed and Raw data. Raw data comes into the GB60 system from any NMEA0183 device, while processed data is produced in the GB60 system itself. GPS position is an example of Raw NMEA0183 data. If more than one GPS is connected to one of the GB60 BBs on the network, the port priorities are used to set the GPS priority. By default, GB60 will share the position reference as Processed Data on the network. This means that it is not necessary to set a priority for position on each of the other computers on the network. The data sharing options are set in the Data Sharing tab in the Optons dialog. 20222444 / B 35

Simrad GB60 The following options are available: OPTION Processed NMEA Sharing Raw NMEA Sharing Repeater Ports Auto Detect Mode: DESCRIPTION Automatically listens to the GlassBridge Network at startup to determine whether to send Processed NMEA Data to other computers or to listen. This decision is based on what network computers are currently doing and what navigation inputs are directly (physically) connected to the computer. This is the default setting. Send Processed NMEA / Listen for Processed NMEA: Explicitly sends/listens to Processed data None: No Processed data sent or retrieved Sends or receives Raw NMEA data on the network. Basically used for sharing NMEA data that is not vessel related, such as AIS target information or external radar targets. Designates the COM ports that will be used to output or repeat all received data. Repeater ports should only be used to forward NMEA data to other devices. Select repeater options in the COMn Repeater Configuration dialog It is recommended to use Processed NMEA data sharing. In cases where both Processed and Raw data is received, processed data takes priority. This is more efficient and also reduces the configuration issues. 36 20222444 / B

SOFTWARE CONFIGURATION 3.8 Identifying the video inputs Up to 4 devices with a composite video output can be connected to a GB60 VSI and GB60 VSI&RSI system via the Video input ports on GB60 BB. A video signal can not be shared on the network. The video device and the monitors that should be set up with a video view must be connected to the same GB60 BB! When a video device is connected and recognized by the GB60 software, the device are named or renamed in the Video tab in the Options dialog. When the video device is installed, settings and stream format should be adjusted from an active video window as described below. Adjusting video device settings The video device settings should be set according to the specifications for the connected device. The settings are adjusted in the Video Decoder and Video Proc Amp tabs in the Properties dialog, activated by selecting the Adjust Settings command in the video pop-up menu. 20222444 / B 37

Simrad GB60 Adjusting stream format The dialog used for setting the video format is activated by pressing the Adjust Stream command in the video pop-up menu. Frame Rate: Defines how often the video picture is updated per second. Output Size: Defines the number of pixels used for presenting the video picture. Setting the Frame Rate or Output Size values too high will decrease the GB60 system s capacity! 38 20222444 / B

INSTALLING CHARTS 4 INSTALLING CHARTS This section holds description for how to install charts on the GB60 system. 20222444 / B 39

Simrad GB60 4.1 The Permit code GB60 uses Passport World Charts and Passport Deluxe charts (available for specific locations in North America) from Jeppesen Marine. When delivered from factory a default large-scale world chart is installed on the GB system, and a DVD with the Passport World Folio (WF) database will follow the system. The WF chart database contains the entire world of vector charts. All chart regions are however encrypted, and a permit code for selected region(s) has to be obtained from a Simrad dealer or directly from Jeppesen Marine (www.passportonboard.com) before the system can be used. When the permit code is created by Jeppesen, they will send a DVD with the latest updated world charts to the customer. The permit code will unlock the purchased regions on the latest charts sent on the CD. As the charts are updated regularly, the DVD shipped with the system may not contain the latest updated world charts. These charts should therefore only be installed if it is impossible to retrieve the new DVD from Jeppesen before the system should be used. The permit code will unlock also previously released databases. Passport OnBoard 0092-427587-7802-945177 The permit code is based on a unique system ID provided for each GB60BB. The system ID (also called the dongle ID) will be stored as the customers ID at Jeppesen Marine. The system ID is found on a sticker located nearby the hardware identification sticker on GB60BB s side panel. 40 20222444 / B

INSTALLING CHARTS 4.2 Obtaining a permit code To obtain a permit code, the system ID has to be submitted to a Simrad dealer or directly from Jeppesen Marine. If this sticker on the GB60BB is unavailable, the ID is found in the Chart table dialog. The dialog is activated by pressing Charts, followed by Chart table buttons, and then selecting the Install tab. 4.3 Installing the charts When a permit code is available, the charts are installed by using the following procedure: 1 Insert the WF DVD into the DVD player 2 Start/restart the GB60 system 3 When the Simrad dialog is displayed, press the System settings button The System Settings dialog will be displayed 20222444 / B 41

Simrad GB60 4 Press the Install WF xx Charts button to display the Passport Chart Installer dialog 5 Select the Next button to start the chart installer 6 Enter the permit code, and press the Next button to continue 42 20222444 / B

INSTALLING CHARTS 7 Press the Browse button to locate the files 8 When the files are found on the DVD, press the Finish button to start copying the charts from the DVD to the GB60 system A progress bar will be shown until all charts are copied When the installation is completed, the display will return to the System Settings dialog 9 Press the Launch GB60 button to start the chart program For further information about how to manage the chart database, refer to the separate GB60 Operator manual. 20222444 / B 43

Simrad GB60 THIS PAGE INTENTIONALLY LEFT BLANK 44 20222444 / B

BACKUP AND RESTORE PROCEDURES 5 BACKUP AND RESTORE PROCEDURES This section includes description for how to make back-up of the GB60 software, and for how to re-install the GB software. 20222444 / B 45

Simrad GB60 5.1 General When the GB60 system is delivered from factory, the software for both operating system and chart system is preinstalled from factory. No additional software should be attended installed on the GB60 BB. Doing so may cause malfunction on the GB60 system! When the GB system is installed and configured, it is strongly recommended to make a back-up of the complete installation. A complete backup will include the operating system as well as all setting made during the configuration procedure. If a restore of the system should be necessary and no backup is available, the GB software will have to be re-installed from the CDs delivered with the system. Refer page 47 onwards. The configuration procedure will then have to be repeated. 5.2 Making a backup Use the following procedure for making a backup of the software installed on the computer: 1 Insert the Simrad memory stick in the DVD drive 2 Shut-down and restart the system The system will now boot on the memory stick, and the following main menu will be displayed: 3 Insert a blank CD/DVD in the DVD drive. 4 Press 1 to start the backup procedure. A running progress bar indicates that the back-up procedure is running. 46 20222444 / B

BACKUP AND RESTORE PROCEDURES 5 Follow the instructions on the display, and eventually insert a new CD/DVD if required. 6 Press any key to return to the main menu when the backup is completed. 7 Remove the Simrad memory stick and any CD/DVD and restart the system. 8 Label the CDs/DVDs and make sure that they are kept in a safe location. 5.3 Restoring the software When backup CDs/DVDs have been created as described in page 46, the software may be restored by using the following procedure: 1 Insert the Simrad memory stick in the DVD drive. 2 Shut-down and restart the system. 3 The system will now boot on the memory stick, and the following main menu will be displayed: 4 Insert the backup CD/DVD containing the system backup. 5 Press 2 to start the restore procedure. A running progress bar indicates that the procedure is running. 6 Follow the instructions on the display, and eventually insert a new CD/DVD if required. 7 Press any key to return to the main menu when the restore is completed. 8 Remove the memory stick and the CD/DVD and restart the system. 20222444 / B 47

Simrad GB60 THIS PAGE INTENTIONALLY LEFT BLANK 48 20222444 / B

SPARE PARTS 6 SPARE PARTS This section includes part numbers for all standard and optional units that may be included in a GB60 system. 20222444 / B 49

Simrad GB60 6.1 Main components PART NUMBER 26058511 GB60 Black Box, Basic DESCRIPTION 26058529 GB60 Black Box, VSI (Video Signal Interface) 26058537 GB60 Black Box, RSI (Radar Signal Interface) 26058503 GB60 Black Box, VSI & RSI (Video & Radar Signal Interface) 26058826 GB60 DVD module 6.2 GB60 Keyboards, Trackballs and Operator panels PART NUMBER DESCRIPTION 44172377 Logitech Marble Trackball 44176022 Cherry keyboard 26058289 KM60 illuminated keyboard with track pad. 26053355 COP20 Illuminated keyboard with track ball. 26058321 PD60 Pointing Device. 26058081 GB60 Armrest Control unit. 6.3 Accessories PART NUMBER DESCRIPTION 44172328 Air inlet filter for GB60 Black Box 50 20222444 / B

SPARE PARTS 6.4 GB60 Optional equipment PART NUMBER 000-0126-00 DESCRIPTION GS10 Active GPS Antenna for surface or pole mounting. 26058610 High resolution IR (night vision) color camera in stainless steel. 27107044 RB50 BB Radar. 27107051 RB60 BB Radar. 26049759 NMEA converter. 44172385 EMC compliant 5m USB extension cable with signal amplifier. 44172393 EMC compliant PS2/USB converter. 700-2100-011 36 pins connector for connection of stand-alone Simrad radar. 20222444 / B 51

Simrad GB60 6.5 GB60 GlassBridge monitors PART NUMBER DESCRIPTION 26058552 12 Monitor, rear or bracket mount. 26058586 12 Monitor with front mounting frame (20mm). 26058560 15 Monitor, rear or bracket mount. 26058594 15 Monitor with front mounting frame (20mm). 26058578 19 Monitor, rear or bracket mount. 26058502 19 Monitor with front mounting frame (20mm). 44177996 Mounting kit for 12 monitor. 44178002 Mounting kit for 15 monitor. 44178010 Mounting kit for 19 monitor. 52 20222444 / B

TECHNICAL SPECIFICATIONS 7 TECHNICAL SPECIFICATIONS This section lists hardware specification for all units included in the GB60 system. 20222444 / B 53

Simrad GB60 7.1 Cable lengths 1 2 3 4 5 6 7 8 9 10 Optional equipment Units that may be delivered by others CABLE NO. CABLE LENGTH DESCRIPTION 1 1.5 m 2 5 m Part of DVD module 3 1.6 m Supplied with keyboard (1.6 m for Cherry keyboard supplied by Simrad) 4 1.8 m Supplied with mouse (1.8 m for Logitech Marble Trackball supplied by Simrad) 5-6 3 m Part of PD60 Supplied with monitor (2m if GlassBridge monitor is supplied by Simrad) 7 5 m Part of GB60 Armrest CU 8 1.5 m (Keyboard) 9 1.7 m (Mouse) 10 1.5 m Part of KM60 Part of COP20 54 20222444 / B

TECHNICAL SPECIFICATIONS 7.2 GB60 Black Box Height:... 173 mm Width:... 532 mm Depth:... 304 mm Net weight...10.2 Kg Color:... Black Environmental Protection:... IP21 Power:... 24V DC Temperature range: Operating:... 0 to + 50 C (32 to 122 F) Storage:... -15 to + 70 C (5 to 158 F) Dimensional drawing:...page 62 onwards. 7.3 DVD Module Height:... 110 mm Width:... 220 mm Depth:... 286 mm Net weight...4.2 Kg Color:... Black Environmental Protection:... IP21 Power:... 24V DC Temperature range: Operating:... 0 to + 50 C (32 to 122 F) Storage:... -15 to + 70 C (5 to 158 F) Dimensional drawing:...page 66 onwards. 20222444 / B 55

Simrad GB60 7.4 KM60 Keyboard and Mouse (Option) Height:... 38 mm Width:... 304 mm Depth:... 169 mm Net weight...0.7 Kg Color:... Black Environmental Protection:... IP68 Temperature range: Operating:... 0 to + 50 C (32 to 122 F) Storage:... -15 to + 70 C (5 to 158 F) Dimensional drawing:...page 67 onwards. 7.5 GB60 Armrest CU (Option) Height:... 160 mm Width:... 82 mm Depth:...67 mm incl. cable nipple Net weight...1 Kg Color:... Black Enclosure material:... Aluminum Mounting:...Panel mounted Environmental Protection:... IP32 Temperature range: Operation:... 0 to +55 C (32 to 131 F) Storage:... 15 to +70 C (5 to 158 F) Dimensional drawing:... page 68. 56 20222444 / B

TECHNICAL SPECIFICATIONS 7.6 PD60 Pointing device (Option) Height:... 110 mm Width:... 82.5 mm Depth:...53 mm incl. cable nipple Net weight...0.4 Kg Color:... Black Enclosure material:... Aluminum Mounting:...Panel mounted Environmental Protection:... IP56 Temperature range: Operation:... 0 to +55 C (32 to 131 F) Storage:... 15 to +70 C (5 to 158 F) Dimensional drawing:... page 69. 7.7 COP20 Operator Panel (Option) Height:... 220 mm Width:... 440 mm Depth:... 135 mm incl. cable bend Net weight...3.8 Kg Color:... Black Enclosure material:... Aluminum Mounting:...Panel mounted Environmental Protection:... IP56 Temperature range: Operating:...0 to +55 C (+32 to +131 F) Storage:... 15 to +70 C (+5 to +158 F) Dimensional drawing:... page 70. 20222444 / B 57

Simrad GB60 7.8 NMEA support The following list shows MNEA0183 data sentences supported by GB60: GPS / DGPS Positioning and Tracking Information GGA Global Positioning System Fix Data GLA LORAN-C Past Position and Time GLF LORAN-C Predicted or Estimated Waypoint Positions and Times GLL Geographic Position - Latitude / Longitude GLP LORAN-C Present Position and Time GOA OMEGA Past Position and Time GOF OMEGA Present Position and Time GOP OMEGA Predicted or Estimated Waypoint Positions and Times GXF TRANSIT Predicted or Estimated Waypoint Positions and Times GXP TRANSIT Present Position and Time RMA Recommended Minimum Specific LORAN-C Data RMC Recommended Minimum Specific GPS / TRANSIT Data VTG Course Over Ground and Ground Speed TTM Tracked Target Message Water Depth Information DBK Depth Below the Keel DBS Depth Below the Surface DBT Depth Below the Transducer DPT Depth 58 20222444 / B

TECHNICAL SPECIFICATIONS Heading Information HCC HCD HDG HDT HVD HVM Compass Heading Heading and Deviation Heading, Deviation, and Variation True HeadingHDMMagnetic Heading Magnetic Variation, Automatic Magnetic variation, Manually Set Wind and Water Speed and Direction Information MWD Surface Wind Direction and Velocity MWV Wind Speed and Angle VBW Ground and Water Speed VDR Set and Drift VHW Water Speed and Heading VWR Relative Wind Speed and Angle VWT True / Theoretical Speed and Angle Supported Autopilot Outputs AAM Waypoint Arrival Alarm APA Autopilot Sentence A APB Autopilot Sentence B BEC Bearing & Distance to Waypoint-Dead Reckoning BOD Bearing - Origin to Destination BPI Bearing & Distance to Point of Interest BWC Bearing & Distance to Waypoint (Great Circle) BWR Bearing & Distance to Waypoint - Rhumb Line BWW Bearing - Waypoint to Waypoint GLL Geographic Position - Latitude / Longitude HDG Heading, Deviation, and Variation HDM Magnetic Heading HDT True Heading HSC Heading Steering Command RMA Recommended Minimum Specific LORAN-C Data RMB Recommended Minimum Navigation Information RMC Recommended Minimum Specific GPS / TRANSIT Data VHW Water Speed and Heading VTG Course Over Ground and Ground Speed 20222444 / B 59

Simrad GB60 WCV WDC WDR WNC WNR WPL XTE XTR ZDA Waypoint Closure Velocity Distance to Waypoint Waypoint Distance, Rhumb Line Distance - Waypoint to Waypoint Waypoint to Waypoint Distance, Rhumb Line Waypoint Location Cross Track Error, Measured Cross Track Error - Dead Reckoning Time & Date Autopilot Talker Identifications DE DECCA Navigator EC Electronic Chart Display ER Engine Room Monitoring System GP Global Positioning System Integrated Instrumentation LA LORAN A LC LORAN C RA Radar and / or ARPA 60 20222444 / B

DRAWINGS 8 DRAWINGS This section includes dimensional drawings, diagrams and cut-out drawings for units in the GB60 system. 20222444 / B 61

Simrad GB60 8.1 Drawings overview Dimensional drawings Parts of the following drawings are enclosed: Name Page Drw.no Rev. GB60 Black Box (3 pages) - Top view 62 N3-605920 A - Back view 64 - Side view 65 GB60 DVD module 66 N2-605884 A KM60 Keyboard/Mouse 67 GB60 Armrest CU remote control 68 N3-605840 A PD60 Pointing Device 69 N3-605842 A COP20 Operator Panel 70 N1-605304 A Cabling diagram Name Page Drw.no Rev. GB60 Cabling diagram 71 N3-605922 A 62 20222444 / B

DRAWINGS 8.2 GB60 Black Box, Top view 532 [20.9] 504 [19.8] 194 [7.6] 304 [12.0] 518 [20.4] 20222444 / B 63

Simrad GB60 8.3 GB60 Black Box, Back view 50 [2.0] SERVICE AREA 50 [2.0] 64 20222444 / B

DRAWINGS 8.4 GB60 Black Box, Side view 200 [7.9] 50 [2.0] 200 [7.9] 173 [6.8] SERVICE AREA 20222444 / B 65

Simrad GB60 8.5 GB60 DVD module, Dimensions 66 20222444 / B

DRAWINGS 8.6 KM60 Keyboard/Mouse, Dimensions 20222444 / B 67

Simrad GB60 8.7 GB60 Armrest CU remote unit, Dimensions =pfjo^a=d_=sm= 68 20222444 / B

DRAWINGS 8.8 PD60 Pointing device, Dimensions pfjo^a=masm= 20222444 / B 69

Simrad GB60 8.9 COP20 Operator Panel, Dimensions 70 20222444 / B

DRAWINGS 8.10 GB60 Cabling diagram NOTE 1 COULD BE DELIVERED BY OTHERS NOTE 2 COULD BE EXTENDED AND CONNECTED TO A USB PORT BY USING THE PS2/USB CONVERTER INCLUDED IN THE SYSTEM DVD MODULE ON/OFF + 1 2 3 4 + - GND 1 2 3 4 5 6 7 8 1 2 3 4 24V POWER SUPPLY 5 m 1.5 m USB PD60 USB CONNECTED TO USB PORT ON DVD MODULE OR GB60 BB KEYBOARD NOTE 1 MOUSE NOTE 1 KM60 1.5 m NOTE 2 GB60 ARMREST CU 5 m CONNECTED BETWEEN KEYBOARD (OR KEYB. PLUG ON KM60) PS2 KEYB. PLUG ON GB60 1 2 3 4 SIMRAD DISPLAYS NOTE 1 RA50/60 RADAR 24V POWER SUPPLY 24V POWER SUPPLY 24V POWER SUPPLY DISPLAY OUTPUT NET NET NET NET VIDEO VIDEO USB USB GB60 BB VIDEO VIDEO USB USB COM 3 SERIAL LINES COM 4 COM 5 1.5 m COM 6 SIMNET PS2 MOUSE PS2 KEYB. RADAR SIGNAL INTERFACE 24V POWER SUPPLY 24V POWER SUPPLY TO SECOND SYSTEM TO THIRD SYSTEM SIMRAD CAMERAS NOTE 1 24V POWER SUPPLY NMEA CONVERTER RX+ RX- TX+ TX- GND TO/FROM NMEA DEVICES e.g. GPS, AUTOPILOT, GYRO, AIS - 20222444 / B 71