Product data sheet accessories control and regulation Accessories AIRWIN

Similar documents
MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Non-communicating room controllers

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Digital electropneumatic positioner

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

JUMO Quantum PID100/PID200/PID300

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

InBin-P Pressure switches from 5 Pa Pa

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

Displays Transducers. Displays and transducers

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

PHOENIX CONTACT Features

Non-communicating room controllers

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Millenium II +: general characteristics

Immersion Temperature Sensors

Digital electropneumatic positioner

Process displays For current and voltage

Digital electropneumatic Positioner for the integrated mounting on process control valves

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Wall-/Pipe Mounted Universal Process Indicator

Digital electropneumatic Positioner for the integrated mounting on process control valves

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Temperature Controller E5C4

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Humidity transmitter for critical climate applications

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

C160 Wall-/Pipe Mounted Universal Process Indicator

MCX08M2 Programmable controller

Converter Box Data Sheet

Universal Controller

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

Level sensor Stainless steel version Model RLT-1000, for industrial applications

MID approval no. DE-08-MI004-PTB004 Date of release

FCU-MULTI Modbus Fan Coil Unit Controller

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Amplifiers, Counters, Timers & Controls

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

T EN TROVIS Electropneumatic Positioner

/8 DIN Universal Process Indicator

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

InReg Volume flow controller Pa

Room unit with PPS2 interface

DMT345 and DMT346 Dewpoint Transmitters

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Hotel Room Controller

LBVR1718. Description. Features channel paperless recorder

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

TM221M16R controller M IO relay

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

SSR - Supplies - Relays

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

InCos-P Pressure sensor 20 Pa Pa

PI-EX-ME-2NAM/COC-24VDC

AB Axis Industries. Use

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

HERZ Actuator 7708, 7990

Neon pr. ph/ ORP measurement. Applications. Description

VENTILATION BUTTONS 24 V DC

Smart Equipment Controls (SEC)

SIMOCODE 3UF Motor Management and Control Devices

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Temperature controller Ducted systems

Digital electropneumatic Positioner SideControl

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Motor protection relays

Digital electropneumatic Positioner for the integrated mounting on process control valves

TSA TEMPERATURE SWITCHES 15.13a

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

EM2020 Selectable AC transducer A (UK)

Vision OPLC. Technical Specifications. V T34 Technical Specifications

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

TM221CE24R controller M IO relay Ethernet

CLEAN ROOM PANEL - CRP5

JUMO TYA 202 SCR Power Controller in a three-phase economy circuit For the continous control of ohmic-inductive loads

AC5160 SiPass integrated controller kit

Faults on the system Proximity switch connection technology:

Transcription:

Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching, limit comparators, program start, status signal BO-CT1 Option board analog input 2 Item no. 0002213 external setpoint settings BO-CT1 Option board interface RS422/485 Item no. 0002214 Communication GLT, modbus BO-CSA-6 Isolation amplifier Item no. 6100114 Control signal amplifier BO-WDK Wall bracket Item no. 6100093 for humidity sensor with sensor tube Ø 20 mm BO-SI Sinter filter Item no. 6100108 Protection for humidity sensor with sensor tube Ø 20 mm

Product data sheet AIRWIN Continuous Controller BO-CT1 The Continuous Controller BO-CT1 is a product of the AIRWIN brand of. It takes over continuous proportional power control of humidifiers with the reference variable relative air humidity, which must be supplied by a humidity sensor. The continuous controller is freely configurable and can be adjusted to the requirements of the customer. Its functionality may be extended with optional modules. Continuous proportional control of up to 5 humidifiers High-contrast multi-color LCD display for actual value, setpoint and operator guidance Operation via four front panel buttons Analogous input for sensor signal, control output for control signal, 2 relay outputs, power supply for external humidity sensor, 2 binary inputs Power supply 110...240 / 48...63 V/Hz Power consumption 13 VA Voltage output sensor 17 / 20 V/mA Relay outputs 230 / 3 V/A Input measuring signal voltage 0 (2)...10 V resistance > 100 kω Input measuring signal power 0 (4)...20 ma resistance < 100 Ω Output control signal voltage 0...10 / 2...10 V / V load resistance 500 Ω Output control signal power 0...20 / 4...20 ma / ma load resistance 500 Ω Protection class front / rear IP 65 / IP 20 Installation dimensions - height x width x depth 57.1 x 99 x 90 mm Panel cut-out - height x width 48 x 96 mm Weight 0.55 kg Ambient temperature 0...55 C Ambient humidity 0...90 % RH Position front panel mounting according to DIN IEC 61554 Continuous controller BO-CT1 Operating manual Seal Fastening elements BO-CT1 continuous controller Item no. 6100101

Product data sheet AIRWIN Extension BO-CT1 Accessories AIRWIN The continuous controller BO CT1 serves as continuous proportional controller for ultrasonic humidifiers of the AIRWIN brand of. The functionality of the controller can be extended by a maximum of two function boards. For this purpose, the optional boards come with 2 binary inputs, analogous input 2 for external setpoint setting and interface RS422/485. Plug-in board for functional extension of the continuous controller BO CT1 Inclusion of up to two additional test boards Optional board with binary inputs to be used for setpoint switch-over, limit comparators, software start, status message Optional board with analogous input to be used as an extension of the input signals, e.g. for external setpoint setting Optional board interface RS422/RS485 for communication between a master and up to 31 slaves Optional board binary inputs Number of binary inputs potential-free 2 Optional board for analogous input Voltage 0(2)...10 V Input resistance voltage > 100 kω Current 0(4). 20 ma Input resistance current < 100 Ω Optional board interface RS422/485 Interface model RS422/RS485 Protocol Modbus, Modbus Integer Baud rate 9600, 19200, 38400 Bd Device address 0...255 Max. number of participants 32 Plug-in board for continuous controller BO-CT1 - height x width x depth 13 x 68 x 21 mm Integration in continuous controller BO CT1 Optional board for use in continuous controller BO CT1 BO-CT1 optional board Use Item no. 2 binary inputs Signal contacts 0002212 Analogous input 2 External setpoint setting 0002213 Interface RS422/485 Communication with BMS 0002214 see chart Item no. see chart

Product data sheet AIRWIN BO-CSA-6 Isolation Amplifier The isolation amplifier BO-CSA-6 is a product of the AIRWIN brand of. It helps to reinforce the proportional control signal 0-10 VDC and can be integrated in the control cabinet SUR/P and SUR/PT. The reinforcement of the control signal by the isolation amplifier allows the proportionate control of up to six humidifiers. By using five isolation amplifiers up to 30 ultrasonic air humidifiers can be controlled. Add-on housing made of PA / V0 Unipolar inputs and outputs 3-way galvanic isolation between input, output and auxiliary voltage Snap-in mounting for standard rail TS35 High reliability Connection with M3 screw terminals 0.14-2.5 mm², rigid or flexible Supply voltage 19.2...30 VDC Power consumption 2 VA Transmission frequency 25 Hz Input control signal voltage 0...10 V Load 100 kω Max overload 50 V Output control signal voltage 0...10 V Current max. 20 ma installation dimensions - height x width x depth 70.4 x 17.5 x 90.5 mm Weight 68 g Ambient temperature 0...50 C Ambient humidity 0...90 % RH Protection IP20 BO-CSA-6 isolation amplifier Installation and operating instructions BO-CSA-6 Item no. 6100114

Product data sheet accessories humidity sensors Accessories AIRWIN The wall console BO-WDK was designed for easy installation of humidity sensors with Ø 20 mm sensor pipe. It is made of plastic and can be installed at the place of operation. It is attached with screws at the console base through three holes. The sinter filter BO SI is used to protect the humidity sensors with a Ø 20 mm sensor pipe against mechanical damage caused by particle bombardment at higher air speeds or damaging deposits. It is screwed onto the sensor pipe. Wall console BO WDK made of plastic for housing humidity sensors with Ø20 mm sensor pipe Sinter filter BO-SI, with coarse pores made of stainless steel to protect the sensor against foreign particles BO-WDK Material plastic BO-SI Material coarse pores, stainless steel Permissible air speed 1.5...20 m/s Temperature range - 50.. + 150 C BO-WDK - height x width x depth 96 x 69 x 61 mm Mounting holes Ø 6.5 mm BO SI - height x width x depth Ø 20 x 25 mm Screw-on thread M18 x 1 mm BO-WDK wall console for housing humidity sensor BO SI sinter filter for the protection of the humidity sensor BO-WDK Item No. 6100093 BO-SI Item No. 6100108