SIMATIC. Process Control System PCS 7 Released modules (V8.2) Security information 1 ET 200M 2. Gateway 3 ET 200PA SMART 4 ET 200S 5.

Similar documents
SIMATIC. Process Control System PCS 7 Released Modules (V8.0 SP2) ET 200M 1. Gateway 2 ET 200S 3. ET 200iSP 4 ET 200S 5 ET 200X 6.

SIMATIC. Process Control System PCS 7 Released Modules (V8.0 SP2) Security information 1 ET 200M 2. Gateway 3 ET 200S 4. ET 200iSP 5 ET 200S 6

SIMATIC. Process Control System PCS 7 Released modules (V8.0) ET 200M 1. Gateway 2 ET 200S 3. ET 200iSP 4 ET 200S 5 ET 200X 6.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)


IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

ST (6ES7132-6FD00-0BB1)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

S7-400 CPU ES XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI;

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Short Description. Version

Readme SiVArc V14 SP1 Update 6

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.


SIMATIC S plus TIA Portal

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC. PCS 7 process control system PCS 7 Basis Library Readme V9.0 (Online) Security information 1. Overview 2. Notes on installation 3

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

SIMATIC. Process Control System PCS 7 PCS 7 Basis Library Readme V8.2 Update 2 (online) Security information 1. Overview 2. Notes on installation 3

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

Siemens Drives & PLCs

SIMATIC. S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Preface. Documentation guide. Product overview.

Product Information on the Manual

Plant Automation Accelerator 2.1 Readme (Online)

SIMATIC. Process Control System PCS 7 PCS 7 Basis Library Readme V8.2 Update 4 (Online) Security information 1. Overview 2. Notes on installation 3

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

Intrinsic Safety Control Drawing

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. Distributed I/O Device ET 200iSP. Preface, Contents. Product Overview Getting Started with Commissioning. Configuration Options.

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual


SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Preface. Guide to the documentation. New properties. Product overview 3

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Preface. Guide SIMATIC. System overview. Integration into the automation system 3. IO-Link system. Function Manual 12/2017 A5E AB

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. S7-1500/ET 200MP Digital output module DQ 32x24VDC/0.5A BA (6ES7522-1BL10-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations


Certificate Z SIMATIC S7 Distributed Safety

Product information on the documentation of the. ET 200SP distributed I/O system SIMATIC ET 200SP. ET 200SP distributed I/O system.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Certificate Z SIMATIC S7 Distributed Safety

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

ET 200S Motor Starters and Safety Motor Starters

No. Product Information Drawing number Edition

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC. SIMATIC Logon V1.6. Security information 1. Conditions for secure operation of SIMATIC Logon 2. User management and electronic signatures 3

BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/ Giá chưa bao gồm thuế VAT

SIMATIC. PCS 7 process control system PCS 7 SMART (V9.0) Security information 1. Preface 2. System Requirements 3. Licenses 4


Load Feeders. Communication-capable load feeders

SIMATIC. PCS 7 process control system CPU 410 Process Automation/CPU 410 SMART. Preface 1. Introduction to the CPU 410. Configuration of the CPU 410 3

CPU 410-5H Process Automation SIMATIC. PCS 7 process control system CPU 410-5H Process Automation. Preface 1. Introduction to CPU 410-5H

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

SIMATIC. Automation system Fail-safe signal modules. Preface. Product overview 1. Configuration options 2. Configuration and parameter assignment

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

COMOS. Lifecycle FLEXnet License Installation and Management. Security information 1. Notices 2. License types 3. Get the HostID 4.

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC. ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Preface. Documentation guide. Product overview.

Transcription:

SIMATIC rocess Control System CS 7 Offer overview Valid for CS 7 as of V8.2 Security information 1 ET 200M 2 Gateway 3 ET 200A SMART 4 ET 200S 5 ET 200iS 6 ET 200S 7 ET 200S 8 ET 200X 9 ET 200pro 10 Repeater 11 Network Components 12 C 13 C-based automation 14 CS 7 15 S7-300 16 S7-400 17 SILUS modules 18 Appendix A 11/2016 A5E36185002-AB

Legal information arning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. ARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified ersonnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. roper use of Siemens products Note the following: Trademarks ARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. roper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability e have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division rocess Industries and Drives ostfach 48 48 90026 NÜRNBERG GERMAN A5E36185002-AB 11/2017 Subject to change Copyright Siemens AG 2016. All rights reserved

Table of contents 1 Security information...9 2 ET 200M...11 2.1 IM...11 2.2 Accessories...12 3 Gateway...15 3.1 IE/B Link...15 3.2 D link...15 3.3 FF Link...17 3.4 Compact FF Link...17 3.5 Link...18 3.6 A coupler...18 3.7 Optical link module...19 3.8 Accessories...20 4 ET 200A SMART...23 4.1 AI...23 4.2 AO...23 4.3 DI...24 4.4 DO...24 4.5 IM...24 4.6 Accessories...25 5 ET 200S...27 5.1 AI...27 5.2 AO...27 5.3 DI...28 5.4 DO...28 5.5 IM...28 5.6 S...28 5.7 Terminal module...29 6 ET 200iS...31 6.1 AI...31 6.2 AI-F...31 Offer overview, 11/2016, A5E36185002-AB 3

Table of contents 6.3 AO...31 6.4 DI...32 6.5 DI-F...32 6.6 DO...32 6.7 DO-F...33 6.8 IM...33 6.9 S...34 6.10 EM...34 6.11 atchdog...34 6.12 Couplers...34 6.13 Terminal module...35 7 ET 200S...37 7.1 AI...37 7.2 AO...38 7.3 DI...39 7.4 DO...40 7.5 FM...42 7.6 IM...42 7.7 S...43 7.8 Terminal module...44 7.9 Motor starter...46 7.10 F motor starter...51 7.11 Motor starter accessories...54 7.12 TM motor starter...54 8 ET 200S...55 8.1 AI...55 8.2 AO...55 8.3 DI...56 8.4 DO...56 8.5 IM...56 8.6 Server module...57 8.7 Bus adapter...57 9 ET 200X...59 9.1 AI...59 9.2 AO...59 4 Offer overview, 11/2016, A5E36185002-AB

Table of contents 9.3 BM_DI...60 9.4 BM_DO...60 9.5 DI...60 9.6 DO...60 9.7 S...61 9.8 Valve...61 10 ET 200pro...63 10.1 AI...63 10.2 AO...63 10.3 DI...63 10.4 DO...64 10.5 F_DI...64 10.6 F_DI/DO...64 10.7 IM...64 10.8 S...65 10.9 Connection modules...65 11 Repeater...67 11.1 Repeater...67 12 Network Components...69 12.1 IE OSM - ESM...69 12.2 XB-000...70 12.3 X100...70 12.4 XC-100...71 12.5 X200...72 12.6 XB200...75 12.7 X300...76 12.8 XR300 Modular...77 12.9 X400...79 12.10 XM400...80 12.11 XR500 Modular...81 12.12 S600 (Industrial Security Module)...82 12.13 700 (LAN)...83 13 C...89 13.1 C Ethernet...89 13.2 C ROFIBUS...89 Offer overview, 11/2016, A5E36185002-AB 5

Table of contents 13.3 C ILAN...90 13.4 Network adapter...90 13.5 Graphics cards...91 13.6 Signal modules...91 13.7 rinters...91 13.8 Chip card reader...92 14 C-based automation...93 14.1 Controller...93 14.2 CS7 BOX...93 14.3 CS7 AS RTX...94 15 CS 7...95 15.1 artner modules...95 16 S7-300...99 16.1 C t...99 16.2 C AS-i...99 16.3 FM...100 16.4 S...100 16.5 SM DI...101 16.6 SM DO...103 16.7 SM DI/DO...105 16.8 SM DI-F...106 16.9 SM DO-F...106 16.10 SM AI...107 16.11 SM AO...109 16.12 SM AI-F...110 16.13 SM MTA...110 17 S7-400...113 17.1 C Ethernet...113 17.2 C ROFIBUS...114 17.3 FM...115 17.4 CU prior to 04/99 (up to CS7 V4.02)...115 17.5 CU as of 04/99 (CS7 V5.0 and later)...116 17.6 H-CU as of 04/99 (CS7 V5.0 and later)...118 17.7 CU as of 08/04 (CS7 V6.1 and later)...120 17.8 H-CU as of 08/04 (CS7 V6.1 and later)...121 6 Offer overview, 11/2016, A5E36185002-AB

Table of contents 17.9 CU as of 12/06 (CS7 V7.0 and later)...121 17.10 H-CU as of 09/07 (CS7 V7.0.1 and later)...124 17.11 CU as of 08/10 (CS7 V7.1.2 and later)...124 17.12 H-CU as of 12/11 (CS7 V8.0 and later)...125 17.13 CU as of 06/13 (as of CS 7 V8.0.2)...125 17.14 CU as of 09/14 (as of CS 7 V8.1)...126 17.15 CU as of 02/16 (as of CS 7 V8.2)...127 17.16 IM...127 17.17 S...128 17.18 Racks...129 17.19 SM DI...130 17.20 SM DO...131 17.21 SM AI...132 17.22 SM AO...133 18 SILUS modules...135 A Appendix...137 A.1 roperties...137 Offer overview, 11/2016, A5E36185002-AB 7

Table of contents 8 Offer overview, 11/2016, A5E36185002-AB

Security information 1 Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit: http://www.siemens.com/industrialsecurity Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under: http://www.siemens.com/industrialsecurity Offer overview, 11/2016, A5E36185002-AB 9

Security information 10 Offer overview, 11/2016, A5E36185002-AB

ET 200M 2 2.1 IM Approved combinations See the "SIMATIC Distributed I/O Device ET 200M" manual for the approved combinations of interface modules and bus modules and for the available functions. roduct name Article no. Firmware version Brief description roperties ET 200M- IM 153-1 ET 200M- IM 153-1, extended environmental conditions ET 200M- IM 153-1 ET 200M- IM 153-1, extended environmental conditions ET 200M- IM 153-2 ET 200M- IM 153-2 ET 200M- IM 153-2 ET 200M- IM 153-2 ET 200M- IM 153-2 6ES7 153-1AA02-0XB0 6ES7 153-1AA82-0XB0 6ES7 153-1AA03-0XB0 6ES7 153-1AA83-0XB0 6ES7 153-2AA01-0XB0 6ES7 153-2AA02-0XB0 6ES7 153-2BA00-0XB0 V3.x 6ES7 153-2BA01-0XB0 V4.x 6ES7 153-2BA81-0XB0 V4.x Bus interface for S7-300 SMs, FM 350 to FM 352, FM 355, C 341, module replacement during operation Bus interface for S7-300 SMs, extended environmental conditions Bus interface for S7-300 SMs, FM 350 to FM 352, FM 355, C 341, module replacement during operation Bus interface for S7-300 SMs, extended environmental conditions Bus interface for S7-300 SMs, FMs (except FM 356-4), module replacement during operation Bus interface for S7-300 SMs, FMs (except FM 356-4), module replacement during operation Bus interface for S7-300 SMs, FMs (except FM 356-4), module replacement during operation, extension of process control functions Bus interface for S7-300 SMs, FMs (except FM 356-4), module replacement during operation, extension of process control functions Bus interface for S7-300 SMs, (outdoor), FMs (except FM 356-4), module replacement during operation, extension of process control functions X 08/ 00 X 10/ 05 X X 11/ 03 X 04/ 00 X 06/ 04 S X 07/ 06 S X 10/ 09 S X 12/ 10 Offer overview, 11/2016, A5E36185002-AB 11

ET 200M 2.2 Accessories roduct name Article no. Firmware version Brief description roperties ET 200M- IM 153-2 ET 200M- IM 153-2 ET 200M- IM 153-2 FO ET 200M- IM 153-2 FO ET 200M- IM 153-4 N HF ET 200M- IM 153-2 ET 200M- IM 153-2 6ES7 153-2BA02-0XB0 V5.x 6ES7 153-2BA82-0XB0 V5.x 6ES7 153-2AB01-0XB0 6ES7 153-2BB00-0XB0 V3.x 6ES7 153-4BA00-0XB0 V4.x 6ES7 153-2BA70-0XB0 6ES7 153-2BA10-0XB0 Bus interface for S7-300 SMs, FMs (except FM 356-4), module replacement during operation, extension of process control functions, up to 12 I/O modules can be operated Bus interface for S7-300 SMs, (outdoor), FMs (except FM 356-4), module replacement during operation, extension of process control functions, up to 12 I/O modules can be operated Bus interface for S7-300 SMs, with fiber optics, FMs (except FM 356-4), module replacement during operation Bus interface for S7-300 SMs, with fiber optics, FMs (except FM 356-4), module replacement during operation, extension of process control functions Bus interface for S7-300 SMs, with ROFINET connection; supports failsafe and HART module, N system redundancy Bus interface for S7-300 SMs (Outdoor); FMs (except FM 356-4), module replacement during operation, up to 12 I/O modules can be operated Bus interface for S7-300 SMs, FMs (except FM356-4), module replacement during operation, extension of process control functions, up to 12 I/O modules can be operated S X S X X 01/ 03 S X 10/ 06 S X S X 2.2 Accessories Approved combinations See the "SIMATIC Distributed I/O Device ET 200M" manual for the approved combinations of interface modules and bus modules and for the available functions. artition 6ES7 195-1KA00-0XA0 Ex partition for ET 200M Bus module 6ES7 195-7HA00-0XA0 Active bus module for ET 200M IM 153; S/IM 12 Offer overview, 11/2016, A5E36185002-AB

ET 200M 2.2 Accessories Bus module 6ES7 195-7HB00-0XA0 Active bus module for ET 200M IM 153; 2x 40 mm Bus module 6ES7 195-7HC00-0XA0 Active bus module for ET 200M IM 153; 1x 80 mm BM IM/IM 6ES7 195-7HD00-0XA0 Active bus module for ET 200M IM 153; IM/IM for redundant IM operation BM IM/IM 6ES7 195-7HD10-0XA0 Active bus module for ET 200M IM 153; IM/IM for redundant IM operation F separator bus module 6ES7 195-7HG00-0XA0 F separator bus module for ET 200M F separator module 6ES7 195-7KF00-0XA0 F separator module for ET 200M 07/ 04 Offer overview, 11/2016, A5E36185002-AB 13

ET 200M 2.2 Accessories 14 Offer overview, 11/2016, A5E36185002-AB

Gateway 3 3.1 IE/B Link Approved combinations See SIMATIC Net; S7-Cs for Industrial Ethernet; Manual, art BL1 for the approved combinations of interface modules, couplers and bus modules as well as for the available functions. IE/B Link N IO 6GK1 411-5AB00 IE/B link ROFINET IO proxy including real-time; gateway between Industrial Ethernet and rofibus; S7 routing; data record gateway; S7 slaves; DV1 slaves; 10/100 Mbps Fast Ethernet; 9.6 Kbps to 12 Mbps ROFIBUS 3.2 D link Approved combinations See SIMATIC Bus links D/A coupler, active field distributor, D/A Link and Link documentation for the approved combinations of interface modules, couplers and bus modules and for the available functions. roduct name Article no. Firmware version Brief description IM 157 6ES7 157-0AA80-0XA0 Interface module for ROFIBUS A; extended temperature range -25... 60 C IM 157 6ES7 157-0AA81-0XA0 Interface module for ROFIBUS A; extended temperature range -25... 60 C IM 157 6ES7 157-0AA82-0XA0 V4.x Interface module for A Link, D V1 to D and A; module replacement during operation, information function, F update via bus, extension of process control functions roperties X 06/ 00 X 12/ 03 S 06/ 06 Offer overview, 11/2016, A5E36185002-AB 15

Gateway 3.2 D link roduct name Article no. Firmware version Brief description roperties IM 153-2 HF IM 153-2 Outdoor IM 153-2 HF IM 153-2 HF Outdoor 6ES7 153-2BA01-0XB0 V4.x 6ES7 153-2BA81-0XB0 V4.x 6ES7 153-2BA02-0XB0 V5.x 6ES7 153-2BA82-0XB0 V5.x A Link, D V1 to D and A; module replacement during operation, information function, F update via bus, extension of process control functions A Link, outdoor, D V1 to D and A; module replacement during operation, information function, F update via bus, extension of process control functions A Link, D V1to D and A; module replacement during operation, information function, F update via bus, extension of process control functions A Link, outdoor, D V1to D and A; module replacement during operation, information function, F update via bus, extension of process control functions IM 153-2 HF Outdoor 6ES7 153-2BA70-0XB0 A Link, D V1to D and A; module replacement during operation, information function, F update via bus, extension of process control functions, D/A Link with extended field bus diagnostics IM 153-2 HF 6ES7 153-2BA10-0XB0 A Link, D V1to D and A; module replacement during operation, information function, F update via bus, extension of process control functions S 10/ 09 S 10/ 07 S S S S 16 Offer overview, 11/2016, A5E36185002-AB

Gateway 3.4 Compact FF Link 3.3 FF Link Approved combinations See SIMATIC Bus links FF Link bus link documentation for the approved combinations of interface modules, couplers and bus modules and for the available functions. roduct name Article no. Firmware version Brief description IM 153-2 FF Outdoor 6ES7 153-2DA80-0XB0 Interface module for SIMATIC FF Link, capable of redundant operation; FOUNDATION Fieldbus Link Master, extended temperature range FDC 157 6ES7 157-0AC84-0XA0 Interface module for SIMATIC FF Link; physical interface for FOUNDATION Fieldbus H1, capable of redundant operation, with integrated bus supply up to 1 A; integrated diagnostics FDC 157 6ES7 157-0AC85-0XA0 D/FF coupler; Interface module for SIMATIC FF Link; physical interface for FOUNDATION Fieldbus H1, capable of redundant operation, with integrated bus supply up to 1 A; integrated diagnostics roperties S S 3.4 Compact FF Link Approved combinations ou can find additional information in the SIMATIC Bus links; Compact FF Link bus link documentation. roduct name Article no. Firmware version Brief description Compact FF Link 6ES7 655-5BA00-0AB0 Interface for FOUNDATION Fieldbus; FOUNDA TION Fieldbus Link Master; for redundant operation; integrated diagnostics extended temperature range; with integrated bus supply up to 0.5 A roperties Offer overview, 11/2016, A5E36185002-AB 17

Gateway 3.6 A coupler 3.5 Link Approved combinations See SIMATIC Bus links D/A coupler, active field distributor, D/A Link and Link documentation for the approved combinations of interface modules, couplers and bus modules and for the available functions. coupler 6ES7 654-0K00-0AB0 coupler; star connection for connection of singlechannel I/O to H system; single interface module coupler 6ES7 197-1LB00-0XA0 coupler; star connection for connection of single-channel I/O to H system; single interface module with integrated RS 485 repeater 10/ 06 3.6 A coupler Approved combinations See SIMATIC Bus links D/A coupler, active field distributor, D/A-Link and -Link documentation for the approved combinations of interface modules, couplers and bus modules and for the available functions. D/A coupler 6ES7 157-0AC00-0XA0 D/A coupler 04/ 00 D/A coupler 6ES7 157-0AC80-0XA0 D/A coupler, non-ex; (outdoor); 400 ma D/A coupler 6ES7 157-0AC81-0XA0 D/A coupler, non-ex; (outdoor); 400 ma D/A coupler 6ES7 157-0AC82-0XA0 D/A coupler, non-ex; (outdoor); 1000 ma, 31 V D/A coupler 6ES7 157-0AC83-0XA0 D/A coupler, non-ex; (outdoor); for redundant operation D/A coupler 6ES7 157-0AC85-0XA0 D/A coupler, non-ex; (outdoor); for redundant operation; extended field bus diagnostics D/A coupler 6ES7 157-0AD00-0XA0 D/A coupler, ex(i) 07/ 01 D/A coupler 6ES7 157-0AD80-0XA0 D/A coupler, ex(ib); extended environmental conditions A 05/ 04 04/ 05 07/ 07 12/ 03 18 Offer overview, 11/2016, A5E36185002-AB

Gateway 3.7 Optical link module D/A coupler, ex 6ES7 157-0AD81-0XA0 D/A coupler; extended environmental conditions (ia), FM certification D/A coupler, ex 6ES7 157-0AD82-0XA0 D/A coupler; extended environmental conditions (ia), FM certification, dust type certification Active field distributor 6ES7 157-0AG81-0XA0 Active field distributor AFD for ROFIBUS A; ring redundancy; 4 spur lines Active field distributor 6ES7 157-0AG82-0XA0 Active field distributor AFD for ROFIBUS A; ring redundancy; 8 spur lines 05/ 04 3.7 Optical link module Approved combinations See the "SIMATIC Bus links D/A Link and Link" manual for the approved combinations of interface modules, couplers and bus modules and for the available functions. roduct name Article no. Firmware version Brief description roperties ROFIBUS OLM 11 ROFIBUS OLM 12 ROFIBUS OLM G11 ROFIBUS OLM G12 6GK1 503-2CA00 V4.x 6GK1 503-3CA00 V4.x 6GK1 503-2CB00 V4.x 6GK1 503-3CB00 V4.x Optical Link Module; 1 RS 485 1 fiber-optic interface (2 BFOC - OF/CF); signaling contact and measuring output, including 2 BFOC connectors Optical Link Module; 1 RS 485 2 fiber-optic interface (4 BFOC - OF/CF); signaling contact and measuring output, including 4 BFOC connectors Optical Link Module; 1 RS 485 1 fiber-optic interface (2 BFOC - multimode fiber-optic cable); signaling contact and measuring output Optical Link Module; 1 RS 485 1 fiber-optic interface (2 BFOC - multimode fiber-optic cable); signaling contact and measuring output Offer overview, 11/2016, A5E36185002-AB 19

Gateway 3.8 Accessories roduct name Article no. Firmware version Brief description roperties ROFIBUS OLM G12-EEC ROFIBUS OLM G11-1300 ROFIBUS OLM G12-1300 ROFIBUS OLM G22 6GK1 503-3CD00 V4.x 6GK1 503-2CC00 V4.x 6GK1 503-3CC00 V4.x 6GK1 503-4CB00 V4.x Optical Link Module; 1 RS 485 2 fiber-optic interface (4 BFOC - multimode fiber-optic cable); signaling contact and measuring output, extended temperature range -20... +60 C Optical Link Module; 1 RS 485 1 fiber-optic interface (2 BFOC - single-mode fiber-optic cable) wavelength 1300 nm for long distances, signaling contact and measuring output Optical Link Module; 1 RS 485 2 fiber-optic interface (4 BFOC - single-mode fiber-optic cable) wavelength 1300 nm for long distances, signaling contact and measuring output Optical Link Module; 2 RS 485 2 fiber-optic interface (2 BFOC) signaling contact and measuring output 3.8 Accessories Approved combinations See the corresponding manuals for the approved combinations of interface modules and bus modules and for the available functions. BM S/IM SILUS extreme 6AG1 195-7HA00-2XA0 BM S/IM 6ES7 195-7HA00-0XA0 Bus module for IM 153 Bus module for IM 153-2 High Feature / IM 153-2 FF Active bus module for 1 load power supply and 1 module; for "hot swap in runtime" function, extended temperature range -25 to +70 C Active bus module for 1 power supply and 1 module BM IM/IM 6ES7 195-7HD80-0XA0 Bus module for IM 157 / IM 153-2 High Feature / IM 153-2 FF Active bus module for 2 modules; for redundant and non-redundant configuration; "hot swap in runtime" function, extended temperature range -25 to +60 C 20 Offer overview, 11/2016, A5E36185002-AB

Gateway 3.8 Accessories BM IM/IM 6ES7 195-7HD10-0XA0 Bus module for IM 153-2 BM 6ES7 195-7HE80-0XA0 Bus module for IM 157 Bus module for redundant IM mode; "hot swap in runtime" function Bus module for redundant configuration of the IM 157 and module hot swap in runtime; temperature range -25 to +60 C BM FDC 6ES7 195-7HF80-0XA0 Bus module for 1 D/A coupler Ex(i) / FDC 157-0 / 1 field device coupler Active bus module for "hot swap in runtime" function, extended temperature range -25 to +60 C BM FDC/FDC 6ES7 195-7HG80-0XA0 Bus module for 2 D/A couplers / 2 field device couplers Active bus module for redundant configuration; for "hot swap in runtime" function, extended temperature range -25 to +60 C BM 6ES7 654-7H00-0XA0 Bus module for coupler BM Compact FF Link 6ES7655-5EF00-0AA0 Bus module for Compact FF Link Active field distributor AFD Active field distributor AFS Active field distributor AFS Active field distributor AFD4 Active field distributor AFD8 Active field distributor AFDiS Active field distributor AFDiSD 6ES7 157-0AF81-0XA0 6ES7 157-0AF82-0XA0 6ES7 157-0AG80-0XA0 6ES7 157-0AG81-0XA0 6ES7 157-0AG82-0XA0 6ES7 157-0AG83-0XA0 6ES7 655-5DX60-1BB0 Active bus module for 2 modules; for redundant and non-redundant configuration; "hot swap in runtime" function, extended temperature range -25... +60 C Active field distributor AFD for A or FF field devices; ring redundancy; 4 short-circuit proof spur line connections Active field distributor AFS for A or FF; coupler redundancy Active field distributor AFS for ROFIBUS A and FOUNDATION Fieldbus H1; coupler redundancy Active field distributor AFD4 for ROFIBUS A and FOUNDATION Fieldbus H1; ring redundancy; 4 short-circuit proof spur line connections Active field distributor AFD8 for ROFIBUS A and FOUNDATION Fieldbus H1; ring redundancy; 8 short-circuit proof spur line connections Active field distributor AFDiS for A or FF field devices; ring redundancy; 6 short-circuit proof and intrinsically safe spur line connections Active field distributor AFDiSD with diagnostics for A or FF field devices; ring redundancy; 6 short-circuit proof and intrinsically safe spur line connections 08/ 12 08/ 12 Offer overview, 11/2016, A5E36185002-AB 21

Gateway 3.8 Accessories 22 Offer overview, 11/2016, A5E36185002-AB

ET 200A SMART 4 4.1 AI AI8 Diag 6ES7 650-8AK60-0AA0 Analog input module 8 AI; 16 Bit 0/4...20mA; with diagnostics AI8 Diag 6ES7 650-8AK60-1AA0 Analog input module 8 AI; 16 Bit 0/4...20mA; with diagnostics; version with protective coating AI16 Diag 6ES7 650-8AK70-0AA0 Analog input module 16 AI; 16 Bit 0/4...20mA; with diagnostics AI16 Diag 6ES7 650-8AK70-1AA0 Analog input module 16 AI; 16 Bit 0/4...20mA; with diagnostics; version with protective coating AI TC/RTD 6ES7 650-8AR60-0AA0 Analog input module 8 AI TC, 4 AI RTD; 16 Bit; with diagnostics AI TC/RTD 6ES7 650-8AR60-1AA0 Analog input module 8 AI TC, 4 AI RTD; 16 Bit; with diagnostics; version with protective coating SM SM SM SM SM SM O C O C O C O C O G O G 4.2 AO AO8 Diag 6ES7 650-8BK60-0AA0 Analog output module 8 AO; with diagnostics AO8 Diag 6ES7 650-8BK60-1AA0 Analog output module 8 AO; with diagnostics; version with protective coating SM SM O C O C Offer overview, 11/2016, A5E36185002-AB 23

ET 200A SMART 4.5 IM 4.3 DI DI32 6ES7 650-8DK80-0AA0 Digital input module 32 DI; DC 24 V DI32 6ES7 650-8DK80-1AA0 Digital input module 32 DI; DC 24 V; version with protective coating DI16 6ES7 650-8DK70-0AA0 Digital input module 16 DI; DC 24 V; with diagnostics DI16 6ES7 650-8DK70-1AA0 Digital input module 16 DI; DC 24 V; with diagnostics; version with protective coating SM SM SM SM O M O M O C O C 4.4 DO DO32 6ES7 650-8EK80-0AA0 32 DO; DC 24 V / 0.5 A DO32 6ES7 650-8EK80-1AA0 32 DO; DC 24 V / 0.5 A; version with protective coating DO16 6ES7 650-8EK70-0AA0 16 DO; DC 24 V / 0.5 A; with diagnostics DO16 6ES7 650-8EK70-1AA0 16 DO; DC 24 V / 0.5 A; with diagnostics; version with protective coating SM SM SM SM O M O M O C O C 4.5 IM roduct name Article no. Firmware version Brief description IM 650-8 6ES7 650-8H00-0AA0 Interface module connection for ET 200A SMART IM 650-8 6ES7 650-8H00-1AA0 Interface module connection for ET 200A SMART; version with protective coating roperties S X S X 24 Offer overview, 11/2016, A5E36185002-AB

ET 200A SMART 4.6 Accessories 4.6 Accessories Accessories Bus module S/IM 6ES7 650-8A00-0AA0 Backplane bus module for power supply and IM 650-8 Bus module S/IM 6ES7 650-8A00-1AA0 Backplane bus module for power supply and IM 650-8 version with protective coating Bus module IM/IM 6ES7 650-8B00-0AA0 Backplane bus module for 2 x IM 650-8 redundant Bus module IM/IM 6ES7 650-8B00-1AA0 Backplane bus module for 2 x IM 650-8 redundant version with protective coating Bus module 6ES7 650-8C00-0AA0 Backplane bus module for 2 x SMART electronic module Bus module 6ES7 650-8C00-1AA0 Backplane bus module for 2 x SMART electronic module Version with protective coating Offer overview, 11/2016, A5E36185002-AB 25

ET 200A SMART 4.6 Accessories 26 Offer overview, 11/2016, A5E36185002-AB

ET 200S 5 5.1 AI 2 AI 2 IRE 6ES7 134-5RB00-0AB0 Analog input module 2 AI I; 2-wire measuring transducer; 0..20 ma / 12 bits + sign, 4... 20 ma / 12 bits 2 AI 4 IRE 6ES7 134-5RB50-0AB0 Analog input module 2 AI I; 4-wire measuring transducer; 0..20 ma / 12 bits, 4... 20 ma / 12 bits 2 AI TC 6ES7 134-5SB00-0AB0 Analog input module 2 AI TC; 15 bits + sign; standard; thermocouples: E, N, J, K, L, S, R, B, T,U 2 AI RTD 6ES7 134-5SB50-0AB0 Analog input module 2 AI RTD; 15 bits + sign; standard; R: 600 Ohm; RTD: t 100, Ni 100: 2 AI 2 IRE HART 6ES7 134-5TB00-0AB0 Analog input module 2 AI; 4... 20 ma, with HART communication for connecting 2-wire measuring transducers 2 AI 4 IRE HART 6ES7 134-5TB50-0AB0 Analog input module 2 AI; 4... 20 ma, with HART communication for connecting 4-wire measuring transducers 09/ 06 09/ 06 09/ 06 09/ 06 09/ 06 09/ 06 5.2 AO 2 AO 0/4-20mA 6ES7 135-5RB00-0AB0 Analog output module 2 AO; 0..20 ma / 12 bits + sign; 4..20 ma / 12 bits 2 AO HART 6ES7 135-5TB00-0AB0 Analog output module 2 AO; 4..20 ma; with HART communication 09/ 06 09/ 06 Offer overview, 11/2016, A5E36185002-AB 27

ET 200S 5.6 S 5.3 DI 4 DI NAMUR 6ES7 131-5RD00-0AB0 Digital input module 4 DI NAMUR 09/ 06 5.4 DO 2 DO 6ES7 132-5SB00-0AB0 2 DO; DC 25 V / 25 ma 09/ 06 5.5 IM ET 200iS-IM 151-2 6ES7 151-2AA00-0AB0 Interface module for ET 200iS electronic modules for intrinsically safe ROFIBUS D X 09/ 06 5.6 S S 6ES7 138-5EA00-0AA0 ower supply for ET 200iS 09/ 06 28 Offer overview, 11/2016, A5E36185002-AB

ET 200S 5.7 Terminal module 5.7 Terminal module TM-E30S-44iS 6ES7 193-5CB00-0AA0 Terminal module for Ems; 4 rows; screw terminal TM-E30C-44iS 6ES7 193-5CB10-0AA0 Terminal module for EMs; 4 rows; spring-loaded terminal TM-S-iS 6ES7 193-5DA00-0AA0 Terminal module for S 09/ 06 TM-IM-iS 6ES7 193-5DB00-0AA0 Terminal module for IM 151-2 09/ 06 09/ 06 09/ 06 Offer overview, 11/2016, A5E36185002-AB 29

ET 200S 5.7 Terminal module 30 Offer overview, 11/2016, A5E36185002-AB

ET 200iS 6 6.1 AI 4 AI I 2IRE HART 6ES7 134-7TD00-0AB0 Analog input module 4 AI; 4... 20 ma; with HART communication for connecting 2-wire measuring transducers 4 AI I 4IRE HART 6ES7 134-7TD50-0AB0 Analog input module 4 AI; 4... 20 ma; with HART communication for connecting 4-wire measuring transducers 4 AI TC 6ES7 134-7SD00-0AB0 Analog input module 4 AI TC 4 AI RTD 6ES7 134-7SD50-0AB0 Analog input module 4 AI RTD 4 AI RTD 6ES7 134-7SD51-0AB0 Analog input module 4 AI RTD M M M M 05/ 08 M 6.2 AI-F 4 AI 2IRE HART 6ES7 138-7FA00-0AB0 Analog input module 4 AI; 0/4... 20 ma; safety-related, ex i;with HART communication for connecting 2-wire measuring transducers M 6.3 AO 4 AO I HART 6ES7 135-7TD00-0AB0 Analog output module 4 AO; 4... 20 ma; with HART communication M Offer overview, 11/2016, A5E36185002-AB 31

ET 200iS 6.6 DO 6.4 DI 8 DI NAMUR 6ES7 131-7RF00-0AB0 Digital input module 8 DI NAMUR M 6.5 DI-F 8 DI NAMUR 6ES7 138-7FN00-0AB0 Digital input module F-DI 8 NAMUR, safety-related, ex i M 6.6 DO 4 DO DC23,1V/20mA 6ES7 132-7RD00-0AB0 4 DO; DC 23.1 V / 20 ma 4 DO DC23,1V/20mA Shutdown "H" 6ES7 132-7RD01-0AB0 4 DO; DC 23.1 V / 20 ma; shutdown "H" 4 DO DC17,4V/27mA 6ES7 132-7RD10-0AB0 4 DO; DC 17.4 V / 27 ma 4 DO DC17,4V/27mA Shutdown "H" 6ES7 132-7RD11-0AB0 4 DO; DC 17.4 V / 27 ma; shutdown "H" 4 DO DC17,4V/40mA 6ES7 132-7RD20-0AB0 4 DO; DC 17.4 V / 40 ma 4 DO DC17,4V/40mA Shutdown "H"" 4 DO DC17,4V/40mA Shutdown "H" 4 DO DC23,1V/20mA Shutdown "L" 4 DO DC17,4V/ 27mAShutdown "L" 6ES7 132-7RD21-0AB0 6ES7 132-7RD22-0AB0 6ES7 132-7GD00-0AB0 6ES7 132-7GD10-0AB0 4 DO; DC 17.4 V / 40 ma; shutdown "H" 4 DO; DC 17.4 V / 40 ma; shutdown "H" 4 DO; DC 23.1 V / 20 ma; shutdown "L" 4 DO; DC 17.4 V / 27 ma; shutdown "L" M 10/ 06 M M 10/ 06 M M 10/ 06 M 06/ 10 M M M 32 Offer overview, 11/2016, A5E36185002-AB

ET 200iS 6.8 IM 4 DO DC17,4V/40mA Shutdown "L" 4 DO DC17,4V/ 40mAShutdown "L" 4 DO DC25,5V/22mA Shutdown "L" 2 DO Relais UC60V/ 2A 6ES7 132-7GD20-0AB0 6ES7 132-7GD21-0AB0 6ES7 132-7GD30-0AB0 6ES7 132-7HB00-0AB0 4 DO; DC 17.4 V / 40 ma; shutdown "L" 4 DO; DC 17.4 V / 40 ma; shutdown "L" 4 DO; DC 25.5 V / 22 ma; shutdown "L" 2 DO relay; UC 60 V / 2 A M 06/ 10 M M M 6.7 DO-F 4 DO 6ES7 138-7FD00-0AB0 4 DO; DC 17.4 V / 40 ma; -switching, safety-related, ex i M 6.8 IM roduct name Article no. Firmware version Brief description ET 200iS-IM 152-1 6ES7 152-1AA00-0AB0 Interface module for ET 200iS electronic modules for intrinsically safe ROFIBUS D ET 200iS-IM 152-1 6ES7 152-1AA00-0AB0 V2.0 Interface module for ET 200iS electronic modules for intrinsically safe ROFIBUS D can be used for redundant operation in the H system roperties S S Offer overview, 11/2016, A5E36185002-AB 33

ET 200iS 6.12 Couplers 6.9 S S DC 24V 6ES7 138-7EA00-0AA0 ower supply for ET 200iS 07/ 06 S DC 24V 6ES7 138-7EA01-0AA0 ower supply for ET 200iS S AC 120/230V 6ES7 138-7EC00-0AA0 ower supply for ET 200iS 6.10 EM EM reserve module 6ES7 138-7AA00-0AA0 Reserve module for free slots 6.11 atchdog atchdog module 6ES7 138-7BB00-0AB0 Special module for station monitoring M 6.12 Couplers RS 485-IS coupler 6ES7 972-0AC80-0XA0 Fieldbus coupler between ROFIBUS D and RS 485-IS; to control intrinsically safe ROFIBUS nodes; installation in Zone 2 possible; extended temperature range 34 Offer overview, 11/2016, A5E36185002-AB

ET 200iS 6.13 Terminal module 6.13 Terminal module TM-EM/EM 60 S 6ES7 193-7CA00-0AA0 Terminal module for 2 EM; screw terminal TM-EM/EM 60 C 6ES7 193-7CA10-0AA0 Terminal module for 2 EM; spring-loaded terminal TM-EM/EM 60 S 6ES7 193-7CA20-0AA0 Terminal module for 2 EM; screw terminal TM-EM Relais C 6ES7 193-7CB00-0AA0 Terminal module for EM relay; screw terminal TM-IM/EM 60 S 6ES7 193-7AA00-0AA0 Terminal module for IM / EM; screw terminal TM-IM/EM 60 C 6ES7 193-7AA10-0AA0 Terminal module for IM / EM; spring-loaded terminal TM-IM/EM 60 S 6ES7 193-7AA20-0AA0 Terminal module for IM / EM; screw terminal TM-IM/IM 6ES7 193-7AB00-0AA0 Terminal module for redundant IM TM-S-A 6ES7 193-7DA00-0AA0 Terminal module for power supply 07/ 06 TM-S-B 6ES7 193-7DB00-0AA0 Terminal module for redundant power supply TM-S-A 6ES7 193-7DA10-0AA0 Terminal module for 24 V DC power supply TM-S-B 6ES7 193-7DB10-0AA0 Terminal module for 24 V DC redundant power supply TM-S-A 6ES7 193-7DA20-0AA0 Terminal module for 120/230 V AC power supply TM-S-B 6ES7 193-7DB20-0AA0 Terminal module for 120/230 V AC redundant power supply 07/ 06 Offer overview, 11/2016, A5E36185002-AB 35

ET 200iS 6.13 Terminal module 36 Offer overview, 11/2016, A5E36185002-AB

ET 200S 7 7.1 AI 2 AI U 6ES7 134-4FB00-0AB0 Analog input module 2 AI; (+/-5 V, 1... 5 V, +/-10 V) / 13 bits; standard 2 AI U 6ES7 134-4FB01-0AB0 Analog input module 2 AI; (+/-5 V, 1... 5 V, +/-10 V) / 13 bits; standard 2 AI I 2DMU 6ES7 134-4GB00-0AB0 Analog input module 2 AI; 2-wire measuring transducer (4... 20 ma) / 13 bits; standard 2 AI I 2DMU 6ES7 134-4GB01-0AB0 Analog input module 2 AI; 2-wire measuring transducer (4... 20 ma) / 13 bits; standard 2 AI I 4DMU 6ES7 134-4GB10-0AB0 Analog input module 2 AI; 4-wire measuring transducer (+/-20 ma, 4... 20 ma) / 13 bits; standard 2 AI I 4DMU 6ES7 134-4GB11-0AB0 Analog input module 2 AI; 4-wire measuring transducer (+/-20 ma, 4... 20 ma) / 13 bits; standard 2 AI I TC 6ES7 134-4JB00-0AB0 Analog input module 2 AI TC; 15 bits; standard 2 AI I TC 6ES7 134-4JB01-0AB0 Analog input module 2 AI TC; 15 bits; standard 2 AI I RTD 6ES7 134-4JB50-0AB0 Analog input module 2 AI RTD; 15 bits; standard 2 AI I RTD 6ES7 134-4JB51-0AB0 Analog input module 2 AI RTD; 15 bits; standard 2 AI U 6ES7 134-4LB00-0AB0 Analog input module 2 AI; (1... 5 V, +/- 5 V, +/- 10 V) / 15 bits; high-resolution 2 AI U 6ES7 134-4LB02-0AB0 Analog input module 2 AI; (1... 5 V, +/- 5 V, +/- 10 V) / 15 bits; high-resolution 2 AI I 6ES7 134-4MB00-0AB0 Analog input module 2 AI; (+/-20 ma, 4... 20 ma) / 15 bits, high-resolution 2 AI I 6ES7 134-4MB02-0AB0 Analog input module 2 AI; (+/-20 ma, 4... 20 ma) / 15 bits, high-resolution 2 AI I TC High Feature 6ES7 134-4NB00-0AB0 Analog input module 2 AI TC; 15 bits; high feature 07/ 05 04/ 05 05/ 05 09/ 08 09/ 08 06/ 06 06/ 06 09/ 05 Offer overview, 11/2016, A5E36185002-AB 37

ET 200S 7.2 AO 2 AI I TC High Feature 2 AI I RTD High Feature 2 AI I RTD High Feature 6ES7 134-4NB01-0AB0 6ES7 134-4NB50-0AB0 6ES7 134-4NB51-0AB0 Analog input module 2 AI TC; 15 bits; high feature Analog input module 2 AI RTD; 15 bits; high feature Analog input module 2 AI RTD; 15 bits; high feature 11/ 05 7.2 AO 2 AO U 6ES7 135-4FB00-0AB0 Analog output module 2 AO; 1... 5 V / 12 Bit, +/-10 V / 13 bits; standard 2 AO U 6ES7 135-4FB01-0AB0 Analog output module 2 AO; 1... 5 V / 12 Bit, +/-10 V / 13 bits; standard 2 AO I 6ES7 135-4GB00-0AB0 Analog output module 2 AO; (+/-20 ma, 4... 20 ma) / 13 bits; standard 2 AO I 6ES7 135-4GB01-0AB0 Analog output module 2 AO; (+/-20 ma, 4... 20 ma) / 13 bits; standard 2 AO U 6ES7 135-4LB00-0AB0 Analog output module 2 AO; (1... 5 V, +/-10 V) / 15 bits; high-resolution 2 AO U 6ES7 135-4LB01-0AB0 Analog output module 2 AO; (1... 5 V, +/-10 V) / 15 bits; high-resolution, supports isochronous mode 2 AO U 6ES7 135-4LB02-0AB0 Analog output module 2 AO; (1... 5 V, +/-10 V) / 15 bits; high-resolution, supports isochronous mode 2 AO I 6ES7 135-4MB00-0AB0 Analog output module 2 AO; (+/-20 ma, 4... 20 ma) / 15 bits; high-resolution 2 AO I 6ES7 135-4MB01-0AB0 Analog output module 2 AO; (+/-20 ma, 4... 20 ma) / 15 bits, high-resolution, supports isochronous mode 2 AO I 6ES7 135-4MB02-0AB0 Analog output module 2 AO; (+/-20 ma, 4... 20 ma) / 15 bits; high-resolution, supports isochronous mode 05/ 05 05/ 05 08/ 03 06/ 06 08/ 03 06/ 06 38 Offer overview, 11/2016, A5E36185002-AB

ET 200S 7.3 DI 7.3 DI 2 DI DC24V 6ES7 131-4BB00-0AA0 Digital input module 2 DI; 24 V DC; standard 2 DI DC24V 6ES7 131-4BB01-0AA0 Digital input module 2 DI; 24 V DC; standard 4 DI DC24V 6ES7 131-4BD00-0AA0 Digital input module 4 DI; 24 V DC; standard 4 DI DC24V 6ES7 131-4BD01-0AA0 Digital input module 4 DI; 24 V DC; standard 2 DI DC24V High Feature 2 DI DC24V High Feature 4 DI DC24V High Feature 4 DI DC24V High Feature 8 DI DC24V High Speed 6ES7 131-4BB00-0AB0 6ES7 131-4BB01-0AB0 6ES7 131-4BD00-0AB0 6ES7 131-4BD01-0AB0 6ES7 131-4BF00-0AA0 Digital input module 2 DI; 24 V DC; High Feature; with diagnostics Digital input module 2 DI; 24 V DC; High Feature; with diagnostics Digital input module 4 DI; 24 V DC; High Feature; with diagnostics Digital input module 4 DI; 24 V DC; High Feature; with diagnostics Digital input module 8 DI; DC 24 V;supports isochronous mode 4 DI 6ES7 131-4CD00-0AB0 Digital input module 4 DI; UC 24... 48 V; High Feature; with diagnostics 4 DI UC 24..48V HF 6ES7 131-4CD02-0AB0 Digital input module 4 DI; UC 24... 48 V; High Feature; with diagnostics 2 DI AC 120V 6ES7 131-4EB00-0AB0 Digital input module 2 DI; 120 V AC 2 DI AC 230V 6ES7 131-4FB00-0AB0 Digital input module 2 DI; 120 V AC 4 DI NAMUR 6ES7 131-4RD00-0AB0 Digital input module 4 DI NAMUR; with diagnostics 4 DI NAMUR 6ES7 131-4RD02-0AB0 Digital input module 4 DI NAMUR; with diagnostics 8 DI DC 24V 6ES7 138-4FA00-0AB0 Digital input module 4 / 8 DI; 24 V DC; 8 DI safety-related SIL-2 or 4 DI safety-related SIL-3, with diagnostics 04/ 05 04/ 05 06/ 05 05/ 05 08/ 10 10/ 10 06/ 04 Offer overview, 11/2016, A5E36185002-AB 39

ET 200S 7.4 DO 8 DI DC 24V 6ES7 138-4FA01-0AB0 Digital input module 4 / 8 DI; 24 V DC; 8 DIsafety-related SIL-2 or 4 DI safety-related SIL-3, with diagnostics 8 DI DC 24V 6ES7 138-4FA02-0AB0 Digital input module 4 / 8 DI; 24 V DC; 8 DI safety-related SIL-2 or 4 DI safety-related SIL-3, with diagnostics 8 DI DC 24V 6ES7 138-4FA03-0AB0 Digital input module 4 / 8 DI; 24 V DC; 8 DI safety-related SIL-2 or 4 DI safety-related SIL-3, with diagnostics 8 DI DC 24V 6ES7 138-4FA04-0AB0 Digital input module 4 / 8 DI; 24 V DC; 8 DI safety-related SIL-2 or 4 DI safety-related SIL-3, with diagnostics 8 DI DC 24V 6ES7 138-4FA05-0AB0 Digital input module 4 / 8 DI; 24 V DC; 8 DI safety-related SIL-2 or 4 DI safety-related SIL-3, with diagnostics 10/ 05 01/ 07 10/ 08 7.4 DO 2 DO DC24V/0.5A 2 DO DC24V/0.5A 2 DO DC24V/2A 2 DO DC24V/2A 2 DO DC24V/0.5A High Feature 2 DO DC24V/0.5A High Feature 6ES7 132-4BB00-0AA0 6ES7 132-4BB01-0AA0 6ES7 132-4BB30-0AA0 6ES7 132-4BB31-0AA0 6ES7 132-4BB00-0AB0 6ES7 132-4BB01-0AB0 2 DO; 24 V DC / 0.5 A; standard 2 DO; 24 V DC / 0.5 A; standard 2 DO; 24 V DC / 2 A; standard 2 DO; 24 V DC / 2 A; standard 2 DO; 24 V DC / 0.5 A; High Feature; with diagnostics 2 DO; 24 V DC / 0.5 A; High Feature; with diagnostics 04/ 05 04/ 05 09/ 05 40 Offer overview, 11/2016, A5E36185002-AB

ET 200S 7.4 DO 2 DO DC24V/2A High Feature 2 DO DC24V/2A High Feature 4 DO DC24V/0.5A 4 DO DC24V/0.5A High Feature 4 DO DC24V/0.5A 4 DO DC24V/0.5A 4 DO DC24V/2A 4 DO DC24V/2A High Feature 4 DO DC24V/2A 4 DO DC24V/2A 8 DO DC24V/0.5A High Speed 8 DO DC24V/0.5A High Feature 2 DO AC 120/230V/ 1A 2 DO AC 120/230V/ 1A 2 DO Rel. 24.230V/5A 2 DO Rel. 24.230V/5A 2 DO Rel. 24.230V/5A 2 DO Rel. 24.230V/5A 4 DO DC 24V/2A 6ES7 132-4BB30-0AB0 6ES7 132-4BB31-0AB0 6ES7 132-4BD00-0AA0 6ES7 132-4BD00-0AB0 6ES7 132-4BD01-0AA0 6ES7 132-4BD02-0AA0 6ES7 132-4BD30-0AA0 6ES7 132-4BD30-0AB0 6ES7 132-4BD31-0AA0 6ES7 132-4BD32-0AA0 6ES7 132-4BF00-0AA0 6ES7 132-4BF00-0AB0 6ES7 132-4FB00-0AB0 6ES7 132-4FB01-0AB0 6ES7 132-4HB00-0AB0 6ES7 132-4HB01-0AB0 6ES7 132-4HB10-0AB0 6ES7 132-4HB12-0AB0 6ES7 138-4FB00-0AB0 2 DO; 24 V DC / 2 A; High Feature; with diagnostics 2 DO; 24 V DC / 2 A; High Feature; with diagnostics 4 DO; 24 V DC / 0.5 A; standard 4 DO; 24 V DC / 0.5 A; High Feature; with diagnostics 4 DO; 24 V DC / 0.5 A; standard 4 DO; 24 V DC / 0.5 A; standard 4 DO; 24 V DC / 2 A; standard 4 DO; 24 V DC / 2 A; High Feature, with diagnostics 4 DO; 24 V DC / 2 A; standard 4 DO; 24 V DC / 2 A; standard 8 DO; 24 V DC/ 0.5 A; supports isochronous mode 8 DO; 24 V DC/ 0.5 A; High Feature, with diagnostics, supports isochronous mode 2 DO; 120 / 230 V, 1 A AC 2 DO; 120 / 230 V, 1 A AC 2 relays; 24..230 V / 5 A UC 2 relays; 24..230 V / 5 A UC 2 relays; form C; 24..230 V / 5 A UC 2 relays; form C; 24..230 V / 5 A UC 4 DO; 24 V / 2 A; DC safety-related up tosil-3, with diagnostics, M-switching 07/ 05 05/ 05 10/ 10 04/ 05 05/ 07 01/ 07 04/ 05 05/ 11 06/ 04 Offer overview, 11/2016, A5E36185002-AB 41

ET 200S 7.6 IM 4 DO DC 24V/2A 4 DO DC 24V/2A 4 DO DC 24V/2A 4 DO DC 24V/2A 6ES7 138-4FB01-0AB0 6ES7 138-4FB02-0AB0 6ES7 138-4FB03-0AB0 6ES7 138-4FB04-0AB0 4 DO; 24 V / 2 A; DC safety-related up tosil-3, with diagnostics, M-switching 4 DO; 24 V / 2 A; DC safety-related up tosil-3, with diagnostics, M-switching 4 DO; 24 V / 2 A; DC safety-related up tosil-3, with diagnostics, M-switching 4 DO; 24 V / 2 A; DC safety related to SIL-3, with diagnostics, M switching 10/ 05 10/ 08 7.5 FM Counter module, 24 V/100 khz 6ES7 138-4DA04-0AB0 Counter module, 24 V / 100 khz; for single, continuous and periodic counting, supports isochronous mode (only counting and measuring modes have been released for CS 7) 7.6 IM IM 151-1 6ES7 151-1BA00-0AB0 Interface module IM 151-1 for ET 200S; high feature IM 151-1 6ES7 151-1BA01-0AB0 Interface module IM 151-1 for ET 200S; high feature IM 151-1 6ES7 151-1BA02-0AB0 Interface module IM 151-1 for ET 200S; high feature X 10/ 05 X 03/ 07 X 42 Offer overview, 11/2016, A5E36185002-AB

ET 200S 7.7 S 7.7 S M-E DC24V 6ES7 138-4CA00-0AA0 ower supply, DC 24 V; with diagnostics M-E DC24V 6ES7 138-4CA01-0AA0 ower supply, DC 24 V; with diagnostics M-E DC24V HF 6ES7 138-4CA60-0AB0 ower supply, DC 24 V; with diagnostics, high feature M-E DC24V/ AC120/230V M-E DC24V..48/ AC24..230V 6ES7 138-4CB10-0AB0 6ES7 138-4CB11-0AB0 ower supply, DC 24 V; AC 120 V or 230 V; with diagnostics and fuse ower supply, DC 24... 48 V, AC 24... 230 V; with diagnostics and fuse M-E DC24V 6ES7 138-4CF00-0AB0 ower supply, DC 24 V; safety-related, with 2 DO 24V M-switching; with diagnostics M-E DC24V 6ES7 138-4CF01-0AB0 ower supply, DC 24 V; safety-related, with 2 DO 24V M-switching; with diagnostics M-E DC24V 6ES7 138-4CF02-0AB0 ower supply, DC 24 V; safety-related, with 2 DO 24V M-switching; with diagnostics M-E DC24V 6ES7 138-4CF03-0AB0 ower supply, DC 24 V; safety-related, with 2 DO 24V M-switching; with diagnostics M-E DC24V 6ES7 138-4CF42-0AB0 ower supply, DC 24 V; safety-related, -switching; with diagnostics M-D DC24V 3RK1 903-0BA00 ower supply, DC 24 V; 2 M-D; DC 24 V M-D F1 SIGUARD 3RK1 903-1BA00 ower supply; EMERGENC OFF; monitored start-up; 2-channel M-D F2 SIGUARD 3RK1 903-1BB00 ower supply; protective door; autostart; 2-channel M-D F4 SIGUARD 3RK1 903-1BC00 ower supply; extension to F1/2 for additional potential group 04/ 05 11/ 06 06/ 04 10/ 05 10/ 08 Offer overview, 11/2016, A5E36185002-AB 43

ET 200S 7.8 Terminal module M-D F3 SIGUARD 3RK1 903-1BD00 ower supply; extension to F1/2 for additional potential group; time-delayed M-D F5 SIGUARD 3RK1 903-1BE00 ower supply; extension to M-D F1 to M-D F4; contact multiplier M-X SIGUARD 3RK1 903-1CB00 Connection module for incoming feeder protection; external safety circuits M-D F ROFIsafe 3RK1 903-3BA00 ower supply for 6 vector groups; safety-related M-D F ROFIsafe 3RK1 903-3BA01 ower supply for 6 vector groups; safety-related M-D F ROFIsafe 3RK1 903-3BA02 ower supply for 6 vector groups; safety-related F-CM 3RK1 903-3CA00 Contact multiplier; extension to M-D F ROFIsafe; M-D F X1 3RK1 903-3DA00 ower supply/expansion module; overvoltage protection; for supplying external EMERGENC OFF signals; for 6 vector groups 10/ 09 7.8 Terminal module TM-E15x26-A1 6ES7 193-4CAx0-0AA0 Terminal module for electronic modules; pass-through AUX rail to adjacent potential group on the left; access to AUX1 potential via terminals TM-E15x24-A1 6ES7 193-4CAx0-0AA0 Terminal module for electronic modules; pass-through AUX rail to adjacent potential group on the left; access to AUX1 potential via terminals TM-E15x24-01 6ES7 193-4CBx0-0AA0 Terminal module for electronic modules; pass-through AUX rail to adjacent potential group on the left; no access to AUX1 potential via terminals TM-E15x23-01 6ES7 193-4CBx0-0AA0 Terminal module for electronic modules; pass-through AUX rail to adjacent potential group on the left; no access to AUX1 potential via terminals 44 Offer overview, 11/2016, A5E36185002-AB

ET 200S 7.8 Terminal module TM-E15x24-AT 6ES7 193-4CLx0-0AA0 Terminal module for electronic modules 2 AI TC HF; pass-through AUX rail to adjacent potential group on the left; no access to AUX1 potential via terminals TM-E30x46-A1 6ES7 193-4CFx0-0AA0 Terminal module for electronic modules; pass-through AUX rail to adjacent potential group on the left; access to AUX1 potential via terminals TM-E30x44-01 6ES7 193-4CGx0-0AA0 Terminal module for electronic modules; pass-through AUX rail to adjacent potential group on the left; no access to AUX1 potential via terminals TM-15x23-A1 6ES7 193-4CCx0-0AA0 Terminal module for power supply; pass-through AUX rail to adjacent potential group on the left; access to AUX1 potential via terminals TM-15x23-A0 6ES7 193-4CDx0-0AA0 Terminal module for power supply; interrupted AUX rail to adjacent potential group on the left; access to AUX1 potential via terminals TM-15x22-01 6ES7 193-4CEx0-0AA0 Terminal module for power supply; pass-through AUX rail to adjacent potential group on the left; no access to AUX1 potential via terminals TM-30x44-A0 6ES7 193-4CKx0-0AA0 Terminal module for fail-safe power supply M-E F; interrupted AUX rail to adjacent potential group on the left; access to AUX1 potential via terminals TM-15S27-01 3RK1 903-0AA00 Terminal module for power supply M-D; with end cover TM-F30S47-B1 3RK1 903-1AA00 Terminal module SIGUARD M-D F 1,2; for potential group, supply U1, U2, sensor connection TM-F30S47-B0 3RK1 903-1AA10 Terminal module for SIGUARD M-D F 1,2 for potential subgroup, sensor connection TM-F30S47-C1 3RK1 903-1AC00 Terminal module SIGUARD M-D F 3,4 for potential group, supply U1, U2 TM-F30S47-C0 3RK1 903-1AC10 Terminal module SIGUARD M-D F 3,4 for potential subgroup, supply U2 Offer overview, 11/2016, A5E36185002-AB 45

ET 200S 7.9 Motor starter TM-F30S47-D0 3RK1 903-1AD10 Terminal module SIGUARD M-D F 5 for contact multipliers TM-X15 S27-01 3RK1 903-1AB00 Terminal module for connection module M- X connection unit for supply contactor TM-F30S47-F1 3RK1 903-3AA00 Terminal module for fail-safe power supply M-D F; pass-through AUX rail to adjacent potential group on the left; no access to AUX1 potential via terminals TM-FCM30S47-E0 3RK1 903-3AB10 Terminal module for F-CM; with bushing for U1 TM-FX30S47-G1 3RK1 903-3AE00 Terminal module for M-D F X1; for potential group; no supply from left for U1 TM-FX30S47-G0 3RK1 903-3AE10 Terminal module for M-D F X1; for potential group; with supply from left for U1 7.9 Motor starter DS1e-x 0,3-3 A High Feature DS1e-x 0,3-3 A High Feature 3RK1 301-0AB10-0AA2 3RK1 301-0AB10-0AA3 Direct starter DS 1e-x; 0.3-3 A; mechanical switching; electronic UE protection; no fuse; up to 1.1 K / 400 V; 0.3 A to 3 A; Option: Brake control module, control module; high feature Direct starter DS 1e-x; 0.3-3 A; mechanical switching; electronic UE protection; no fuse; up to 1.1 K / 400 V; 0.3 A to 3 A; Option: Brake control module, control module; switch ES; high feature 05/ 04 46 Offer overview, 11/2016, A5E36185002-AB

ET 200S 7.9 Motor starter DS1e-x 0,3-3 A High Feature DS1e-x 2,4-8 A High Feature DS1e-x 2,4-8 A High Feature DS1e-x 2,4-8 A High Feature DS1e-x 2,4-16 A High Feature DS1e-x 2,4-16 A High Feature 3RK1 301-0AB10-0AA4 3RK1 301-0BB10-0AA2 3RK1 301-0BB10-0AA3 3RK1 301-0BB10-0AA4 3RK1 301-0CB10-0AA2 3RK1 301-0CB10-0AA3 Direct starter DS 1e-x; 0.3-3 A; mechanical switching; electronic UE protection; no fuse; up to 1.1 K / 400 V; 0.3 A to 3 A; Option: Brake control module, control module; switch ES; high feature; circuit-breaker notification can be assigned Direct starter DS 1e-x; 2.4-8 A; mechanical switching; electronic UE protection; no fuse; up to 3 K / 400 V; 2,4 A to 8A; Option: Brake control module, control module; high feature Direct starter; DS 1e-x; 2.4-8 A; mechanical switching; electronic UE protection; no fuse; up to 3 K / 400 V; 2,4 A to 8 A; Option: Brake control module, control module; switch ES; high feature Direct starter DS 1e-x; 2.4-8 A; mechanical switching; electronic UE protection; no fuse; up to 3 K / 400 V; 2,4 A to 8 A; Option: Brake control module, control module; switch ES; high feature; circuit-breaker notification can be assigned Direct starter DS1e-x 2.4-16 A; mechanical switching; electronic UE protection; no fuse; up to 7.5 K / 400 V; 2,4 A to 16 A; Option: Brake control module, control module; high feature Direct starter DS 1e-x; 2.4-16 A; mechanical switching; electronic UE protection; no fuse; up to 7.5 K / 400 V; 2,4 A to 16 A; Option: Brake control module, control module; switch ES; high feature 05/ 04 05/ 04 Offer overview, 11/2016, A5E36185002-AB 47

ET 200S 7.9 Motor starter DS1e-x 2,4-16 A High Feature DSS1e-x 0,3-3 A High Feature DSS1e-x 0,3-3 A High Feature DSS1e-x 0,3-3 A High Feature DSS1e-x 2,4-8 A High Feature DSS1e-x 2,4-8 A High Feature 3RK1 301-0CB10-0AA4 3RK1 301-0AB20-0AA2 3RK1 301-0AB20-0AA3 3RK1 301-0AB20-0AA4 3RK1 301-0BB20-0AA2 3RK1 301-0BB20-0AA3 Direct starter DS 1e-x; 2.4-16 A; mechanical switching; electronic UE protection; no fuse; up to 7.5 K / 400 V; 2,4 A to 16 A; Option: Brake control module, control module; switch ES; high feature; circuit-breaker notification can be assigned Direct soft starter DSS 1e-x 0.3-3 A; electronic switching; electronic UE protection; no fuse; up to 1.1 K / 400 V; 0,30 A to 3,00 A; Option: Brake control module, control module; high feature Direct starter DSS 1e-x; 0.3-3 A; electronic switching; electronic UE protection; no fuse; up to 1.1 K / 400 V; 0.3 A to 3 A; Option: Brake control module, control module; switch ES; high feature Direct starter DSS 1e-x; 0.3-3 A; electronic switching; electronic UE protection; no fuse; up to 1.1 K / 400 V; 0.3 A to 3 A; Option: Brake control module, control module; switch ES; high feature Direct soft starter DSS 1 e-x; 2.4-8 A; electronic switching; electronic UE protection; no fuse; up to 3 K / 400 V; 2.4 A to 8 A; Option: Brake control module, control module; high feature Direct soft starter DSS 1e-x; 2,4-8 A; electronic switching; electronic UE protection; no fuse; up to 3 K / 400 V; 2.4 A to 8 A; Option: Brake control module, control module; switch ES; high feature 05/ 04 05/ 04 48 Offer overview, 11/2016, A5E36185002-AB