Manual EM260 with Volume Corrector EK220/260/280

Similar documents
Manual EM260. Contents 3 WIRING OF EM260 S COMMUNICATION INTERFACE 3 4 PARAMETERS OF THE INTERNAL SERIAL INTERFACE IN THE EK230 3

Extension module for BACnet over Ethernet / IP and graphic Web functions

Converter Box Data Sheet

Installation & Configuration manual. InduBox GSM IV

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

connecdim Gateway G1 Ethernet TCP/IP to DALI

ISDN OEM1. DesignGuide V1.2

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Hardware Manual RM CANview

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

Extension module for graphic Web functions for one automation station

Manual Industry Interfaces

DF PROFI II PC/104-Plus

MEC-COM-M134. User s Manual

Extension module for Web functions generic

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Hardware Reference. with DIL/NetPC ADNP/9200. Remote Access Gateway IGW/922

ISDN - SOC. DesignGuide. Rev 2.2

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

SoundwebTM. Installation Guide

F1000 User's Manual. (Version: V1.01)

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Sauter Systems

RTU560 Remote Terminal Unit Connections and Settings

Miniature Asynchronous Modems

LLM-336S.Eth. Introduction. Features. Industrial Leased line modem with internal Ethernet Bridge.

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Universal communications device Metcom T A..

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

PXR11 PXR12. System controllers DESIGO PX

TM221CE40T controller M IO transistor PNP Ethernet

MGate 4101-MB-PBS Series

MGate 5105-MB-EIP Series

Miniature Asynchronous 4-Wire High Speed Modems

Manual Fiber Optic Interfaces

EPC-APL. Quick Reference Guide. Intel Pentium /Celeron Processor Fanless Tiny System. Copyright Notice. 1 st Ed 12 September 2017

User Manual A08. User Manual

EZ864 UMTS Terminal Telit Cellular GSM Engine

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

ME-9000i isolated Serial Interface Board, RS232, RS422, RS485

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

TM221CE24R controller M IO relay Ethernet

RTU560 Connections and Settings DIN Rail RTU 560CIG10

HEC. General Operating, Maintenance and Installation Manual

TM221CE40R controller M IO relay Ethernet

NPort Z2150/Z3150 Series

Serial PROFIBUS Interface

DATA CONNECT ENTERPRISE

Cable Pinouts. SRP I/O Module

Remote Maintenance of Controllers via Serial Port

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Features and Benefits. SNMP MIB-II for network management. Certifications

TM221CE24T controller M IO transistor PNP Ethernet

-C5RS-LC RS232 EXTENDER

Channel Switch CS. General Operating, Maintenance and Installation Manual

Accessories / 7XV5820

TM221ME16T controller M IO transistor PNP Ethernet

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

Industrial Serial Device Server

Appendix. Specifications

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

General Operating, Maintenance and Installation Manual

Order Information. (*) ask for details at our sales department

C-Bus Pascal Automation Controller

W&T Manual Interface modules W&T

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

EX-RC1 Remote I/O Adapter

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

4170 POS System Installation Guide

Feature and Benefits. Certifications

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Features and Benefits. Certifications

Features and Benefits. Certifications

EX-RC1 Remote I/O Adapter

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Powered RS Port PCIe Card

+70 C -25 C 95% RH EMC

Cable and Port Specifications

2xGbE (1x Intel I210, 1x Realtek RTL8111G), 1x HDMI, 1x VGA, 1x USB3.0, 2x USB2.0

Development KIT for TM2 GPRS modem User manual 1.2. Development KIT. Development KIT for TM2 GSM/GPRS modem User s manual 1.2

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

SENECA s.r.l. Commercial

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

TM221CE40R controller M IO relay Ethernet

Transcription:

with Volume Corrector EK260/280 Manual EM260 with Volume Corrector EK220/260/280 Manual: 73021398 Version: g Release: 03.01.2014 Edition: - Contents 1 SAFETY INSTRUCTIONS 2 2 FEATURES 2 3 WIRING EM260 EK220/260/280 3 4 WIRING OF EM260 S COMMUNICATION INTERFACE 3 5 SETTINGS OF THE SERIAL INTERFACE IN THE EK220/260/280 3 6 SETTING THE PARAMETERS FOR THE COMMUNICATION MODULE 4 7 REPLACEMENT OF COMMUNICATION MODULES 5 8 POWER SUPPLY 5 9 OPERATING STATUS DISPLAY 5 10 JUMPER 5 11 TECHNICAL DATA 6 Betriebsanleitung-EM260-EK2x0_en_g.doc 1 of 6

with Volume Corretor EK260/280 1 Safety Instructions! Please read these instructions carefully before assembling, installing or commissioning the EM260 to avoid any damage, dangers or problems. Assembly and installation should be carried out by qualified personnel!! The AC version of the EM260 has a power supply of 90...260 V. Do not touch any live parts as this is extremely dangerous! Shut off the power supply before carrying out any installation work and before opening the housing! Switch the power back on only after all of the work has been completed and the housing has been firmly closed! Other notes: The PE connections in both the EM260 and the EK2x0 should be as short as possible and have as wide a cross-section as possible. When assembling the front cover, ensure that the flat-strip cable for connecting the LEDs integrated into the front transparent film is plugged into the 4x1 pin strip ST8! 2 Features Modem for use with ELSTER LIS-100 and LIS-200 end devices Internal TTL interface for one of the following communication modules: Standard analogue modem ISDN adapter Ethernet LAN adapter. ELSTER-CL0 interface card RS232 / V.24 interface to end device (RxD, TxD, Gnd, DCD, DTR, RI), galvanically separated Power supply for EK2x0 and EK-88 5 VDC outputs for interface component of LIS100 devices, only switched on during modem connection (online status) EMC in accordance with standards EN55011 Class B, EN55024, EN61326 and EN12405 (standard for volume correctors) Operating status display: Power on (green LED), Ring and Online (yellow LED) Apart from mains cable, all cables are already assembled exworks (Plug & Play): Data cable Power supply for end device Communication cable (TAE, ISDN, Ethernet). 2 / 6 Betriebsanleitung-EM260-EK2x0_en_g.doc

with Volume Corrector EK260/280 3 Wiring EK220/260/280 EM260 EK terminal Direction EM260 EK220 EK260 EK280 of data terminal TxD TD TxD TxD DTR RS RTS DTR RxD RD RxD RxD DCD CS CTS DCD n.c. RI RI RI n.c. Gnd GND GND Uext Uext + Uext + +9V GND Uext - Uext - GND For the wiring, a shielded 8-wire cable (Elster-Instromet ID no. 04250469) is recommended. In the EM260 the cable is assembled by Elster-Instromet exworks. When connecting the EM260 to the EK2x0, please ensure the cable is properly inserted into the EMV cable fitting on the EK2x0. 4 Wiring of EM260 s communication interface If an analogue modem, an ISDN adapter or an Ethernet adapter is mounted inside the EM260, the corresponding cable is also mounted by Elster-Instromet exworks. The cable is connected to the terminals a(rx-), b(rx+), a2(tx-) and b2(tx+). When using a CL0 interface, a shielded cable with two leads (e.g. ID no. 04250467, 2 x 1,0 mm 2 ) must be connected on site by the customer in the following way: EM260 terminal a (Rx-) b (Rx+) Terminal in the CL1 modem CL- / Rx- CL+ / Rx+ 5 Settings of the serial interface in the EK220/260/280 If the EK2x0 is delivered together with the EM260, the EK2x0 s internal serial interface as well as the communication module integrated in the EM260 are properly set by Elster-Instromet exworks. If the EM260 is delivered separately for additional installation beside an EK2x0, the internal serial interface of the EK2x0 must be set in accordance with the software version of the EK2x0 and with the type of communication module integrated in the EM260. The serial interface of the EK2x0 must be parameterised before the EM260 is connected to the EK2x0 and switched on. For this purpose the parameter software WinPADS200-EK or ensuite (only for EK280) can be used: - WinPADS200-EK: Menu Data transfer, item Send parameter file - ensuite: Item Send parameter file, then button Open Then you can select the parameter file (*.WPP) which fits to your application (communication module, version of EK2x0). Example: EM260 with an analogue modem connected with an EK280 V2.0: EK280_2v2.. - EM260 & i-modul Analogmodem_a.WPP If there is no laptop with WinPADS or ensuite available on site, you can set the most important values via the keypad of the EK2x0 (EK220/260: menu Ser.IO, EK280: menu Terminal Interface ). The following values cannot be set via the keypad: SMS specific values, ISDN MSN, IP address for Ethernet. The following table contains the most important parameters which can be set via the interface menu: Betriebsanleitung-EM260-EK2x0_en_g.doc 3 of 6

with Volume Corretor EK260/280 Communication module EK260 SW vers. Md.S2 (2:705) DF.S2 (2:707) Bd.S2 (2:708) ----- TypS2 (2:709) 1) (2:70A) Num.T (2:720) Analogue 4) all 2 0 19200 19200 1 1, 2 9 ISDN up to 2.3.. 5 0 19200 19200 1-3) from 2.4.. 2 0 19200 19200 1 1 Ethernet up to 2.3.. 5 2 19200 19200 1-3) from 2.4.. 2 2 19200 19200 1 1 2) 300... 300... CL from 2.0.. 5 0 od. 2 19200 2) 2) 19200 1 3) - EK280 SW-Vers. MdxS2 (2:706) Analog ab 2.0.. standard AT auto 19200 19200 RS232 1 ISDN ab 2.0.. standard AT auto 19200 19200 RS232 1 Ethernet ab 2.0.. standard AT auto 19200 19200 RS232 1 CL ab 2.0.. transparent auto 300... 300... 19200 2) 2) 19200 RS232 3) - 1) Not available in in the interface menu! Can only be modified with WinPADS200-EK or ensuite! 2) According to the settings in the CL1 modem and the other devices installed in the current loop (CL). 3) This setting (number of rings) is not used in mode 5. In mode 5 the communication module in the EM260 always picks up an incoming call after the first ring signal. 4) Numbers in bold: Exworks settings performed by Elster-Instromet if the EK2x0 is delivered without any modem. 6 Setting the parameters for the communication module The parameters for the communication module (modem) in the EM260 are set ex-works for use with an EK2x0. If the parameters have to be modified on site, this can be carried out with the help of the parameter software WinPADS200-EK : Menu File transfer, item Send parameter file. Then you can select the parameter file (*.WPP) which fits to your application (communication module, version of EK2x0). Example: EM260/Analogue modem with EK260 V2.55 EK260_2v5.. - EM260 & int. Analog-Modem (Insys)_b.WPP Before disconnecting, the button Init modem should be pressed ( Interface Modem initialisation ). after it is disconnected, the EK2x0 sends the parameters to the communication module. The parameters are also sent after switching on the power supply and after M.INI=1 in EK2x0 s menu Ser.IO. The parameterisation of the communication module does not work with all EK2x0 versions and also not with all types of communication modules. The following table shows the dependences ( x means: Communication module can be parameterised by the EK2x0): Software version of EK260 Remarks Analogue ISDN Ethernet CL0 1.11 1) 1) 1) from V2.0.. up to V2.3.. x 1) 3) 1) 3) 2) from V2.4.. x x x EK280 From 2.0.. x x x 2) 1) Parameterisation can be carried out only by Elster-Instromet exworks or by Elster-Instromet customer service on site with the help of the software tool ModemIni (ID no. 73017249). 2) CL0 interface need not be parameterised 3) The modem parameters, of course, can be set by WinPADS200-EK ( Interface String for connected modem ), but after carrying out the parameterisation (Button Init modem, M.INI=1 or switching on power supply) they must be deleted again!!! Otherwise the communication module will not pick up any further incoming call!!! 4 / 6 Betriebsanleitung-EM260-EK2x0_en_g.doc

with Volume Corrector EK260/280 7 Replacement of communication modules A faulty communication module can be substituted by another communication module of the same type by the customer on site. It depends on the software version of the EK2x0 and on the type of the communication module if the new module can be parameterised on site or if it must be parameterised by Elster-Instromet exworks (refer to the table in chapter 6). The replacement of a communication module by another communication module of a different type (e.g. analogue modem replaced by ISDN adapter) can only be carried out by Elster- Instromet exworks or by Elster-Instromet s customer service. 8 Power supply The voltage required for power supply is marked on the nameplate (90...260 VAC / 18...30 VDC). The three left screwing terminals are connected as follows: 90...260 VAC version: 18...30 VDC version: ~ ~ PE + - PE 9 Operating status display Green LED: Power on Yellow LED: Ring / Online The yellow Online-LED has the following meanings: Analogue Modem / ISDN / Ethernet LED status Meaning off no connection flashing briefly ringing signal on online / data transfer NB: when a CL interface is in use, the Online-LED is always off!!! 10 Jumper J1 J2 J3 J1 J2 J3 up up up Analogue Modem / ISDN / Ethernet / CL up up down up Reserved down up up Setting parameters for analogue modem / ISDN / Ethernet down down down up Reserved any down Reserved. Betriebsanleitung-EM260-EK2x0_en_g.doc 5 of 6

with Volume Corretor EK260/280 11 Technical Data Internal communication module (only one of the following possibilities is integrated into the EM260): Standard analogue modem: V.32bis (14.4 kbps) ISDN adapter: V.110, V.120, X.75, PPP, HDLC Ethernet-LAN adapter: 10base-T, 10Mbit/s. ELSTER-CL0 interface card RS232 / V.24 interface to the end device (RxD, TxD, Gnd, DCD, DTR, RI), galvanically separated, screw terminals for leads with cross section 0.5...1.5 mm 2 Power supply for EK2x0 and EK-88: output 8.5 VDC +/-5% / 50 ma, galvanically separated, screw terminals for leads with cross section 0.5...1.5 mm 2 5 VDC outputs for interface component of LIS100 devices, only switched on during modem connection (online status), screw terminal for lead with cross section 0.5...1.5 mm 2 Power supply: 90...260 VAC, L, N, PE 18...30 VDC, +, -, PE screw terminal for lead with cross section 0.5...1.5 mm 2 Synthetic housing (standard ABS) with metallised surface inside, IP65 in accordance with EN60529, EMV cable fitting for shielded cable, otherwise synthetic cable fittings Ambient temperature: - with analogue modem INSYS i-module-modem : 0... + 50 C - with ISDN adapter TA+HUX : 0... + 50 C - with CL interface (CL0, passive): -10...+ 60 C - with Ethernet card: 0...+ 50 C Ambient humidity: max. 93%, non condensating Declaration of EU conformity in accordance with the current version of the EMC-Directive 89/336/EEC: The product EM260 conforms to the current versions of the following standards: Emission EN 55011 Class B (for domestic and commercial applications) Immunity EN 61326 (Electrical equipment for measurement, control and laboratory use) EN 12405 (Volume correctors) EN 55024 (IT equipment, data transmission devices) 6 / 6 Betriebsanleitung-EM260-EK2x0_en_g.doc