LEA_IT_DAC Datalogger CUM Instruments and Systems for Geotechnical and Structural Monitoring

Similar documents
crio Multi-Channel Acquisition Unit mod. crio_vw01

G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

LEA_EN_INC Inclinometer With digital Sensor. Instruments and Systems for Geotechnical and Structural Monitoring

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

GSV-6BT GSV-6BT. Description

InteliLite MRS17 Click Here to Learn More

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

Programmable Relay ZEN V2 Units

Process displays For current and voltage

Comprehensive Modular Genset Controller

Data Sheet. RS Datascan data acquisition system

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

MCX08M2 Programmable controller

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

C100 Portable Multifunction

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION

AANDERAA. DATALOGGERS 3634 and 3660

DIGITAL PRESSURE SENSOR SCANNER CUM DATALOGGER

RS-485 I/O Modules: ADAM-4000

100% electricity. Automatic transfer switch controllers ATL series

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Precision thermometer Model CTR5000

DATENBLATT. DT85-Serie. dex Logger Software ab Seite 14

DIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG

GS828-H. GPRS Data Logger

SX 6000 Paperless Recorder

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

LBVR1718. Description. Features channel paperless recorder

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GS828. GPRS Data Logger

world class water monitoring series 42

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

HL20-A Measurement and Control System

SCADAPack 50. Wireless Remote Data Logger

A general-purpose industrial input/output

Pen Drive USB Datalogger!

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

Circuit Breaker Analyzer & Timer CAT126

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Strain Gauge Converter

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

WI-I/O 9 Multi I/O Units

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

Circuit Breaker Analyzer & Timer CAT66

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

Control instruments GUARDIAN 2 - GUARDIAN 3

X-Log Expert Data Logger

em4 Accessories Digital expansions

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

Circuit Breaker Analyzer & Timer CAT126

DIGITAL INDICATING CONTROLLER

CABINET OMNIALOG DATA ACQUISITION SYSTEMS OMNIACABXX FEATURES

GeoLogger Linx Series

DAS-8000 Data Acquisition System Version 2.5

Vibrating Wire Instrument Assembly Guide

Multi-functional precision thermometer CTR3000

MODEL 9250 Preliminary data sheet

EC 600 Electronic Volume Corrector

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Samba PLC+HMI SM35-J-RA22

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

A2000 Multifunctional Power Meter

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

EXOcompact. Third generation freely programmable controllers

Hand-held thermometer Model CTH7000

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

HD32.7 HD HD [ GB ] 8-input Data Logger for Pt100 probes with SICRAM module

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

Circuit Breaker Analyzer & Timer CAT126

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

A NEW DATA LOGGER Stand alone. Secure. Fast.

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

( F L O W I Z F A M I L Y )

RUC industrial relays of small dimensions

Display and Monitoing Units

HD32MT.1. Programmable Data Logger ENGLISH

Tap Position Indicator - PI

MULTICHANNEL DATA RECORDERS

Digital Speed Controller User Manual

Low Power Modbus GPRS Data Logger

Specification for temperature sensor calibration setup

Transcription:

LEA_IT_DAC1001001 Datalogger CUM3000

LEA_IT_DAC1001001 Datalogger CUM3000 Descrizione _ The Data Logger CUM 3000 is entirely developed and manufactured by Pizzi Instruments for applications in geotechnical and structural monitoring. It can read and acquire data from almost all monitoring instruments available on the market today including vibrating wire, analog (voltage and current), potentiometers and pulse etc. Among the instruments readable with the Datalogger CUM3000 are also Maihak and Carlson sensors, still present in different structures in Italy and elsewhere. Through the connection via specific Multiplexers, CUM3000 allows the connection and control of up to a maximum of 480 sensors, such as vibrating wire, analog or digital (RS485). Rugged, durable and fully realized in our laboratories, it is simple and efficient and also suitable for the most complex environments. The CUM3000 can be configured and managed via keyboard and integrated display or remotely via PC using specific Sentinel software. It automatically acquires data from instruments using preconfigured scan sequences, or remotely via manual command for single instrument measurements. Remote single instrument measurement, via the real-time functions of the Sentinel software, is a particular feature of our data logger and is useful for the real-time monitoring of some remote sensors. The parameters of each sensor connected to CUM3000 can be configured and stored directly in the data logger allowing communication of data both in electrical and physical form. Measurements and configurations are automatically transmitted via modem or other remote communication system, or locally transferred via PC connection or other portable device. The CUM3000 can function either as a stand-alone unit or connected to the data logger network (multilogger systems). Depending on the number and type of connected sensors, it can be provided in low consumption configuration with type D power supply batteries.

In automatic monitoring systems the data-logger CUM3000 is usually integrated with the following accessories and components: Multiplexers 12V Power supply or solar panel Overvoltage protection Modem for data transmission Applications _ Main applications are: RCC dams, concrete and earthfill dams Tunnels Bridges and viaducts Railway and road embankments Walls and diaphragm walls Monuments Residential and historical buildings Archaeological structures Mines and excavations Underground works Landslides Others In addition: Structural monitoring Geotechnical monitoring Load test on piles Laboratory tests Any application where analog, vibrating wire or digital sensors (with known protocol), are requested.

Features and benefits _ Fully developed and produced by our company in Florence Flexibility in configuration Easy to use Stand-alone or network multilogger Management and reading of all geotechnical and structural monitoring instruments Robust and compact Low consumption and standby functions Functioning test for connected sensors Possibility to manage and configure both locally and remotely Possibility of implementing measurements in both automatic and manually from remote Local and remote alarm Individual configuration and settings for each datalogger sensor Return of engineered data Watchdog functions and self-diagnosis

Operation _ Our experience in the design and construction of vibrating wire instruments has enabled us to design and create the datalogger CUM3000, characterized by the most actual electronic components available today combined with tested and reliable measurement methods. The unit uses high-resistance components, meeting the security requirements of the most important institutions, such as testing for electromagnetic compatibility required by ENEL. The data logger is designed to ensure maximum reliability and durability in harsh environments and difficult conditions such as those found in the monitoring of dams. Protection to the entrance of signals (input signals), and power source, and multiplexers with relay in a nitrogen environment, ensure hardware settings have maximum security and reliability. The data logger is configured and managed through both the display and integrated keypad or through the configuration function of the Sentinel monitoring software suite. It can be configured for automatic acquisitions with adjustable frequency or perform precise measurements with both local commands from the keyboard and remotely through the application of real-time Sentinel software. The parameters of each sensor connected to CUM3000 can be configured and stored directly in the data logger enabling the communication of measurements in electrical format and physical units. The measurements and configurations are automatically transmitted via modem or other remote communication systems or locally transferred through the connection of a PC or other portable device. The CUM3000 can function either as a stand-alone unit or connected to the data logger network (multilogger systems). Depending on the number and type of connected sensors, it can be provided in low power configuration power supply batteries mod D. The CUM3000 is capable of reading almost all instrumentation present today on the geotechnical and structural market, including: Level meters Automatic coordimeters Crackmeters Strain gauges Piezometers Meteorogical sensors Thermometers Inclinometers Vibrating wire sensors Analog sensors Potentiometric sensors Sensors and systems with digital output

Technical specifications N of Channels A/D Converter Type of selector Memory Communication Ports Interval of acquisition Clock Type of modem Alarms Power Supply Absorption Consumption Chassis 0 480 24 bit Relay with 2 or 4 contacts, current of contact 1A, contact resistance < 50mΩ, insulation tension : between contacts and open circuit 1500 Vdc, between contact and coil 2000 Vdc, insulation resistance 1000 MΩ 15360 measurements N 1 Serial Port of Communication with PC: RS-232 / RS485 / RS422. (1 bit of start, 1 bit of stop, 8 bit of data, no parity, velocity 75 19200 baud) Communication Serial Port with sensors (channels MUX): RS-232 / RS485 / RS422. (1 bit of start, 1 bit of stop, 7/8 bit of data, parity E/0, velocity 75 19200 baud) 2min. / 5min./ 20min. / 1hour / 6hours / 8hours / 12hours / 24hours / 48hours / 1week Accuracy 1 minute / month GSM; GPRS; 2G;Satellite;ADSL; Analogic for phone line PSTN; Radio 2,4Ghz; Radio VHF; Adjustable thresholds 12 Vdc 5 VA max 20 micro Ampere in Stand by and 60 ma in full uses Painted aluminum ; thickness 2mm Operation temperature 40 C + 85 C Display Keyboard Input Protection Sensor Autonomy Data Output Dimensions of chassis Alphanumeric LCD (20 digits x 4 rows), Led backli Composed by 6 function keys; momentary button protected by polycarbonate film thickness 175 µm Transzorber Overvoltage Protection on relay board for each sensor At least 6 months with 4 acquisition a day and 24 VW connected sensors In physical units after appropriate programming 162mm x 114mm ; h = 85,6mm

Technical specifications for different type of sensor Measurable Sensors Accuracy Measurement Measuring Range Resolution Vibrating Wire (350 6000) Hz 0,01% F.S. 350 6000 Hz 0,01 Hz Voltage ± 5Vdc 0,003% F.S. ± 5000 mv 0,010 mv Current 4 20 ma 0,02% F.S. 4 20 ma 0,762 µa Potentiometer Magneto Resistive 1 10 KΩ 0,001% F.S. ±50% 0,001% Thermo resistance PT100 0,06% F.S. -50 +99 C 0,06 C Thermo resistance CU30 0,06% F.S. -50 +99 C 0,06 C Pulse counting 1 pulse 0 65.536 impulsi 1 pulse Potentiometer Resistive 1KΩ 10 KΩ 0,001% F.S. ±50% 0,001% Resistance 0 1000 Ω 0,02% F.S. 0,000 99,999 Ω 0,001 Ω Resistive Bridge 0,003% F.S. ±9 mv/v 0,0001 mv/v NTC 0,06 C F.S. -20 80 C 0,06 C Vibrating Wire GALILEO (350 6000 Hz) 0,01% F.S. ra 350 6000 Hz 0,01 Hz Vibrating Wire Maihak 0,01% F.S. 350 6000 Hz 0,01 Hz Carlson/C 0,06% F.S. -50 +99,9 C 0,06 C Carlson/Ratio 0,003% F.S. 70 130% 0,001% Carlson/Ohm 0,02% F.S. 20 80 ohm 0,001 Ω

Accessories and related products Multiplexer Modulo Alimentatore Protezioni Pannello Solare Modulo Trasmissione Dati Scatole di giunzione Pannello di Misura e Selezione Pannello di Misura Mux 8 canali 220 Vac/12 Vdc Protezioni contro le sovratensioni Da dimensionare secondo le specifiche del sistema GSM; GPRS; 2G; Satellitare; ADSL; Analogico per linea telefonica PSTN; Radio 2,4 Ghz; Radio VHF; Dimensioni e gradi di protezione vari Pannello di misura completo con schede MUX per selezione automatica Pannello di misura semplice Multiplexer - MUX 8 Number of channels 8 Type of internal relay Resistance to insulation a.c. Insulation Voltage a.c. Conduction Resistance Maximum contact current Protections from overvoltages Power Supply Type Protection Degree 2 or 4 contacts At least 1000MΩ 1500V between contacts; 2000V between contacts and coil Less than 50mΩ 1 A Protections from overvoltages on transzorber on relay card for each sensor 12V Painted aluminum thickness 2mm IP 40 (EN60529) Operation temperature 40 to 85 C Installation Connection on a DIN bar Technical Assistance If you have any requests or questions about our instruments or if you have special needs that require different solutions from the standard, please contact us. Our team will provide all the necessary information and will be very happy to work with you to study, develop and customize instruments and solutions suitable for your specific needs.

LEA_IT_DAC1001001 Datalogger CUM3000 The product information may be subject to variations at any time. Please carefully check the release and contact Pizzi Instruments for further details. Pizzi Instruments S.r.l. Tel/Fax: +39 055 6810722 Via di Ripoli 207/F info@pizzi-instruments.it 50126 - Florence - Italy