IDA8C. Networkable PAVA system Controller Unit. IDA8 System

Similar documents
Public Address Voice Alarm CATALOGUE D e l i v e r i n g Yo u r Me s s a g e

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

EMS10 - EMS50. Cameo specification sheet. Product Description

W W. Public Address & Voice Evacuation System. Flexible and scalable configuration Fully digitalised audio transmission

VIPEDIA-12. Cameo specification sheet. Product Description

MPS01. Paging and Emergency Microphone

MPS10 - MPS50. Modular Paging and Emergency Microphones

MX X 250W AMPLIFIED MASTER UNIT

MU 9186R MASTER UNIT WITH ROUTER

Automated Remote Messaging ARM-911A RM-911D RM-911W

Commercial Audio CATALOGUE Public Address - Voice Alarm Audio Distribution over IP. Commercial Audio

AUDIO MANAGEMENT SYSTEM

Data sheet FC-9 DSP system controller. Amp Contoller-Series DSP-Amplifiers + DSP-Controller.

EN60849/IEC60849 compliant

Voice Alarm System VX-3000 Series

FreeSpace Amplifiers. Premium commercial amplifiers designed to enhance audio installations using Bose FreeSpace loudspeakers.

TitanONE Smart Mainframe Power Amplifier

Voice Alarm System VX-3000 Series

CLOUD CX261 Single Zone Mixer

USER GUIDE 1 of 26 STAGEGRID 4000 User Guide rev.01 abr-18

Voice Alarm System VX-3000 Series

TeamConnect Ceiling Ceiling microphone conference system

TeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox

DATA SHEET TESIRAFORTÉ DAN AI

Compact Mixing Console 52/SX. Digital Broadcast Technology

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

MATRIX-MIXERS AUTOMIXER AX 8042 and ZONER ZX 8060 FOR INSTALL SOUND AND COMMERCIAL AUDIO APPLICATIONS ENG

PSSG2 CD Touch Microphone Console. User Manual

8 x 8 Audio Matrix with Local Control PX (With RM-8000/LM-8000)

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

by BSS Audio Detailed product description 1 Introduction

Series 52. Compact Mixing Console. audio.com DHD. Digital Broadcast Technology. audio. Made in Germany

System Interface Unit SIU-100/100T

ex 800A Series ematrix System

VM SERIES Rackmount 100V mixer-amplifiers

SYNAPSE. High Channel Density Networked Audio Interfaces AES67. Common Features DM 1. D32 o. D32 i. Product Family Overview. Applications.

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

IP100 Series. IP116-D Model is Shown

Audio Over Ethernet AOE-212N

AMX-9-DSP4-ACD YEARS OF EXPERTISE. DIGITAL AUTOMATIC PRE-AMPLIFIER

TOA Net Price List PROFESSIONAL USER

D-901 ALL-IN-ONE MODULAR DIGITAL MIXER

TeamConnect TeamConnect System - The perfect audio solution for meetings

Digital Mixing System D-2000 Series

N8000. Electro-Voice N8000. Full IRIS-Net Software Support. 32-Channel Digital Matrix Bus. 115 db Dynamic Range

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

CU 6005 DCS 6000 Medium Power Central Control Unit

V-9908 MESSAGE/PAGE PANEL

TOA ELECTRIC CO., LTD.

LPT-C2 & LPT-C6 ListenPoint Standard & Advanced Control Unit (CU)

IP Desktop Intercom Stations 12 NIB 001 Series

DATA SHEET DEVIO DEVIO CR-1 CONFERENCE ROOM DEVICE

Multimedia digital audio mixer

LA8 Amplified Controller

MX-Net Inter-Controller Network

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

Digital Audio Matrix System. NPX System

BSS EURO PRICELIST JUNE 2017 (OA) THIS PRICELIST REPLACES ALL EARLIER PUBLISHED PRICELISTS

INTEGRATED VOICE EVACUATION SYSTEM

MASELEC MTC-6 master transfer and monitor system

HORECA140BK. Plug & Play Audio Set ECLER TECHNICAL DATA SHEET AUDIO SETS

AP 701 Access Panel. Features and Functions

DR bit Digital Mix Processor 12 in 8 out Audio System PC configuration software

SIP-Based Audio Distribution Over IP. Architect's and Engineering s. Specification

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

PMX-CSK Promatrix Call Station Kit

Overview. Features. Technical Data Sheet 1 / 5. Signal Processor MRX7-D

MINERVA MX MX-Net Inter-Controller Network

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

PRELIMINARY DATA SHEET AM 1 AUTOMIXER SHIPS APRIL 2010

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

AUTROVOICE MULTIVES EXCHANGEABLE MODULES

HCS-5300MA/ 80 Digital Infrared Wireless Conference Main Unit

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

INTEGRATED VOICE EVACUATION SYSTEM

INTEGRATED VOICE EVACUATION SYSTEM

AMP100 AMP102 AMP110 AMP210 AMP310

N-8000 SERIES IP INTERCOM SYSTEM

IPCSDTouch-G 1/5. GLOBALCOM.IP Touch Screen Digital Communication Station. IPCSDTouch-H (Handheld Microphone Version) Features. General Description

Digital Audio Matrix System. NPX System

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

PXR 1506 / WATT MIXER AMPLIFIER

Digital Audio Matrix System. NPX System

Redundancy Concepts. INTRON-D plus. Single System with N+1 Components Duplicated Control System (hot stand-by operation) A+B System (shared operation)

1 master and 8 independent stereo subgroup Flexible architecture including a modular control surface, outputs

USB MP3 MIXING AMPLIFIER MA-206U/212U/224U

MAJOR VA Power Inverter

IP-ZCM. PoE+ IP to Analog Gateway (Zone Controller)

TR2000 Network Audio Matrix

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Quick Start Guide. Installation. User s Manual 1

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

xin 4, xio 4x4 and xout 4

Alternative B Type Mid-Span Power Sourcing Equipment. User s Guide

MG12XU Overview Features Technical Data Sheet

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

The SOUND4 IMPACT. Dual Power supply 2 Processing path: FM & HD

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Transcription:

IDA8C Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Networkable PAVA system Controller Unit IDA8 System IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

D e l i v e r i n g Y o u r M e s s a g e

IDA8C Networkable PAVA system CONTROLLER UNIT IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations. Connectivity: Main characteristics Public address and emergency sound system control unit Fully digital with 8 audio inputs and 8 audio outputs 4 dedicated and monitored PDC-ports for firemen s microphones 2 dedicated audio in and outputs for back-up amplifiers Enhanced loudspeaker line surveillance for AB-zoned installation Simultaneous control and routing of 48 audio channels over dedicated network Equiped as standard with RJ45 network cards (NET-C1) for links up to 100 m Optional Fibreoptic cards for links up to 20 km 9 supervised control inputs and 8 control outputs Ethernet interface for configuration, control, diagnostics and logging Digital storage for up to 4 hours of prerecorded messages 4 message players Stores the last 999 fault events EN54-16 certified The IDA8C Controller unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, with front panel access for a fully monitored fireman s microphone and emergency message trigger buttons. IDA8C also supports amplifier monitoring with hot-swap amplifiers and loudspeaker line impedance monitoring. It can support up to four PSS-AS monitored microphone consoles and up to eight monitored amplifiers plus two back-up amplifiers, paging into 8 different zones per unit with A/B line detection according to BS5939 part 8. Two card slots are provided for either 4-channel 0dB audio input or 4-channel audio cards. Optional AES/EBU cards are also available. Each IDA8C input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delaylines. Up to 4 hours of digital messaging (WAV format) can be stored for live or pre-recorded playback. Digital audio files are uploaded from a computer to the IDA8S through the user-friendly ATEÏS Studio GUI. Several messages can be played simultaneously into different zones: up to 4 messages from a single IDA8C Controller or a total of 48 messages across an IDA8 system (controller with slaves). A built-in loudspeaker on the IDA8C allows selective feedback for all sources and 100V output signals. IDA8S Slave units can extend the system configuration with an additional 8 inputs and 8 outputs and 2 back-up amplifiers. The slave units are available as single zone (IDA8S) or with A/B speaker line configurations (IDA8SAB), or for Low-impedance monitoring (IDA8SL). The IDA8C Controller unit enables operators to see a detailed overview of the operational status of the entire PA system at the press of a button. It is able to run an impedance scan of all components connected to it, covering not only the input paging consoles but also connectors, cabling, processing blocks such as compressors and limiters, delay lines, the network and loudspeakers. The IDA8C Controller operates either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored. IDA8C is easily configured using the PC-based ATEÏS Studio global software. Once programmed, the system will operate independently (off-line) without a PC having to be connected. Security In accordance with EN54-16, ISO 7240-16 and BS5839/8, all IDA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally-generated pilot tone is available for monitoring impedance on the loudspeaker lines. The system can handle 256 priorities for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements. The controller monitors the status of all the equipment in the system, reports status changes and logs the last 999 fault messages in the system. The log can be accessed on the front-panel IDA8C display or on a PC through ATEÏS Studio. The IDA8C system (controller and slaves) supports redundant network cabling, wired as a redundant loop. 3

IDA8 system IDA8C Networkable PAVA system CONTROLLER UNIT Installation Notes 4

IDA8C Networkable PAVA system CONTROLLER UNIT Controls and indicators Front 3,5 full colour touch-screen LCD display Zone selection buttons EVAC-start Fireman s microphone Status indicators Rear Voltage selector Interconnections Front Firemen s microphone Rear Mains input Battery backup input 9 control inputs 8 control outputs 4 analogue audio mic/line inputs 4 analogue audio line inputs Ethernet LOCAL network in/out card Free slot for GLOBAL-network card 8 amplifier in and outputs 2 connections for back-up amplifiers 4 monitored paging console inputs Certifications and Approvals Region Certifications Europe CE CE 0359 (Intertek) Immunity according to EN50103-4 PAVA EN54-16 certified 2012 Parts Included Quantities Components 1 IDA8Cxx Controller unit 1 Power cord 1 Set of mounting brackets for 19 rack 1 Set of connectors 1 Ateis Studio software GUI Technical Specifications Electrical Mains power supply Voltage 115 or 230 VAC ±15%, 50/60 Hz Power consumption 48 W Battery power supply Voltage 18-26 VDC Performance Frequency response -3 db @ 20 Hz and 20 khz Loudspeaker lines in 8 x 100 V Rated load resistance 20 ohm (100 V) Rated load capacitance 250 nf (100 V) Rated output power (per channel) Loudspeaker lines out 500 W (cont. at 40 C) 8 x (A+B) Rated load resistance 20 ohm (100 V) Rated load capacitance 250 nf (100 V) Rated output power (per channel) Mechanical Dimensions (H x W x D) With 19 rackmount brackets Weight Mounting Colour 500 W (cont. at 40 C) 88 x 483 x 305 mm 5.36 kg (11,8lb) 19 -rackmount RAL7016 Environmental Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity 15% to 90% Air pressure 600 to 1100 h Pa Line inputs (Optional audio input card) Ordering Information Connector Frequency response 3-pin phoenix -3 db @ 20 Hz and 20 khz IDA8C-C1-IO Controller with NET-C1 card & 4 audio inputs & 4 audio outputs S/N THD >90 dba < 0,1% @ 1 khz IDA8C-C1-2I Controller with NET-C1 card & 8 audio inputs Input sensivity 770 mv Input impedance 20 kohm Line outputs (Optional audio output card) Connector 3-pin phoenix S/N >-85 dbu THD < 0,02% @ 1 khz Signal 770 mv Output impedance <300 ohm 5

IDA8C Networkable PAVA system CONTROLLER UNIT 1. Fireman microphone active 2. Fireman microphone input 3. Fireman microphone hook 4. Monitoring loudspeaker (Audible warning) 5. Bypass mode 6. General fault 7. System fault 8. Global EVAC 9. Bypass monitoring 10. 3.5 Touch screen 11. ESC - button 12. OK button 13. Up button 14. Down button 15. Plus button 16. Minus button 17. EVAC indicators 18. FAULT indicators 19. RESET button 20. Power 21. Network 22. EVAC button 1. Speaker zone outputs (A+B) 2. Back-up amplifiers (2x) 3. Amplifier 0dB line outputs 4. Bypass mode contact input 5. EVAC and GF output contact 6. 7. Ethernet PDC-ports for secured paging consoles 8. Local network card 9. Global network card 10. Audio I/O 11. Telephone line input 12. Telephone controller 13. Bypass mode outputs 14. Contact outputs, 8x 15. Contact inputs, 9x 16. 24VDC slave output 17. 24VDC back-up input 18. AC power socket 6

IDA8S IDA8 Networkable PAVA system SLAVE UNIT IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations. Main characteristics Public address and emergency sound system slave unit Fully digital with Optional: 8 audio inputs and 8 audio outputs 2 dedicated audio in and outputs for back-up amplifiers 2 dedicated and monitored PDC-ports for fireman s microphones Enhanced loudspeaker line surveillance for zoned installations Simultaneous control and routing of 48 audio channels over dedicated network Equipped as standard with RJ45 network cards for links up to 100m Optional Fibreoptic cards for links up to 20 km 9 supervised control inputs and 8 control outputs Ethernet interface for configuration, control, diagnostics and logging Digital storage for up to 4 hours of pre-recorded messages 4 message players EN54-16 certified Connectivity: The IDA8S Slave unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, along with amplifier monitoring for hot-swap amplifiers and loudspeaker line impedance monitoring. It can support up to two PSS-AS monitored microphone consoles and up to eight monitored amplifiers plus two backup amplifiers, paging into 8 different zones per unit with line detection. Two card slots can fitted with optional 4-channel analogue audio input/outputs cards or 4-channel audio AES/EBU cards (max two cards per device). IDA8S Slave units extend the IDA8 system configuration with an additional 8 output zones and 2 back-up amplifiers. Each input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delay-lines. Up to 4 hours of digital messaging (WAV format) can be stored for live or pre-recorded playback. Digital audio files are uploaded from a computer to the IDA8S through the user-friendly ATEÏS Studio GUI. Several messages can be played simultaneously into different zones: up to 4 messages from a single IDA8S Slave or a total of 48 messages across an IDA8 system (controller with slaves). The IDA8S Slave operates either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored. The IDA8S Slave also supports redundant loop network cabling. IDA8S is easily configured using the PC-based ATEÏS Studio global software. Once programmed, the system will operate independently (off-line) without a PC having to be connected. Security In accordance with EN54-16, ISO 7240-16 and BS5839/8, all IDA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally-generated pilot tone is available for monitoring impedance on the loudspeaker lines. The system can handle 256 priorities for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements. The controller monitors the status of all the equipment in the system, reports status changes and logs error details. The log can be accessed on the front-panel IDA8C display or on a PC through ATEÏS Studio. 7

IDA8S IDA8 Networkable PAVA system SLAVE UNIT Installation Notes 8

IDA8S IDA8 Networkable PAVA system SLAVE UNIT Controls and indicators Front Status LEDs Zone LEDs Power LEDs Rear Voltage selector Interconnections Rear Mains input Battery backup input 9 control inputs 8 control outputs Optional 4 analogue audio mic/line inputs Optional 4 analogue line audio inputs 2 system LOCAL-network connections 8 amplifier in and outputs 2 connections for back-up amplifiers Certifications and Approvals Region Certifications Europe CE CE 0359 (Intertek) Immunity according to EN50103-4 PAVA EN54-16 certified 2012 Parts Included Quantities Components 1 IDA8Sxx Slave unit 1 Power cord 1 Set of mounting brackets for 19 rack 1 Set of connectors 1 Ateis Studio software GUI Technical Specifications Electrical Mains power supply Voltage 115 or 230 VAC ±15%, 50/60 Hz Power consumption 48 W Loudspeaker lines in 8 x 100 V Rated load resistance 20 ohm (100 V) Rated load capacitance 250 nf (100 V) Rated output power (per channel) Loudspeaker lines out 500 W (cont. at 40 C) 8 x Rated load resistance 20 ohm (100 V) Rated load capacitance 250 nf (100 V) Rated output power (per channel) Mechanical Dimensions (H x W x D) for 19 rack use, with brackets Weight IDA8S Mounting Colour 500 W (cont. at 40 C) 88 x 483 x 285 mm 4.2 kg (9.25 lb) 19 -rackmount RAL7016 Battery power supply Voltage Performance Frequency response Line inputs Connector Frequency response S/N THD Input sensitivity Input impedance 18-26 VDC -3 db @ 20 Hz and 20 khz (Optional input card) 3-pin phoenix (electronically balanced) +/-3 db @ 20 Hz and 20 khz >90 dba < 0,1% @ 1 khz 770 mv 20 kohm Environmental Operating temperature Storage temperature Relative humidity 15% to 90% Air pressure Ordering Information -5 ºC to +55 ºC (+23 ºF to +131 ºF) -40 ºC to +70 ºC (-40 ºF to +158 ºF) 600 to 1100 h Pa IDA8S-C1 Slave with NET-C1 card IDA8S-C1-IO IDA8S-C1-2I IDA8S-C1-2O Slave with NET-C1 card & 4 audio inputs & 4 audio outputs Slave with NET-C1 card & 8 audio inputs Slave with NET-C1 card & 8 audio outputs Line outputs Connector S/N THD Signal Output impedance (Optional output card) 3-pin phoenix >-85 dbu < 0,02% @ 1 khz 770 mv < 300 ohm 9

IDA8S IDA8 Networkable PAVA system SLAVE UNIT 1. System fault 2. General fault 3. Bypass mode 4. Bypass monitoring 5. Global EVAC 6. EVAC indicators 7. Power 8. Network 9. FAULT indicators 1. Speaker zone outputs (8x) 2. Back-up amplifiers (2x) 3. Amplifier 0dB line outputs 4. Bypass mode outputs 5. PDC-ports for secured paging consoles 6. Local network card 7. Audio I/O (Optional) 8. 8 Contact outputs 9. 9 Contact inputs 10. 24 VDC input 11. 24 VDC back-up input 10

IDA8SAB IDA8 Networkable PAVA system SLAVE UNIT A/B zoning IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations. Main characteristics Public address and emergency sound system slave unit Fully digital with up to 8 audio inputs and outputs (optional) 2 dedicated and monitored PDC-ports for fireman s microphones 2 dedicated audio in and outputs for back-up amplifiers Enhanced loudspeaker line surveillance for AB-zoned installations Simultaneous control and routing of 48 audio channels over dedicated network Equipped as standard with RJ45 network cards for links up to 100 m Optional fibreoptic cards for links up to 20 km 9 supervised control inputs and 8 control outputs Ethernet interface for configuration, control, diagnostics and logging Digital storage for up to 4 hours of pre-recorded messages 4 message players EN54-16 certified Connectivity: The IDA8SAB Slave unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, along with amplifier monitoring with hot-swap amplifiers and loudspeaker line-impedance line monitoring. It can support up to two PSS-AS monitored microphone consoles, up to eight monitored amplifiers plus two backup amplifiers and paging into 8 different zones per unit with A/B line detection according to the BS 5939-part 8. Two rear card slots can be fitted with optional 4-channel analogue audio in/output cards 4 channel AES/EBU cards for digital audio in/out. IDA8SAB Slave units can extend the IDA8 system configuration with an additional 8 output zones and 2 back-up amplifiers. Up to 4 hours of digital messaging can be stored in the unit for live or scheduled playback. Files are uploaded in WAV format from a computer using the ATEÏS Studio system GUI. Several messages can be played simultaneously into different zones: up to 4 from a single IDA8SAB or a total of 48 messages across a full IDA8 system with slaves. Each input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delay-lines. IDA8SAB is easily configured with PC-based ATEÏS Studio global software. Once programmed, the system will run independently without a PC connected. The IDA8SAB Slave operates either on AC mains power or on a 24V DC battery power supply for emergency back-up, with automatic switchover. Both of the power supplies are monitored Security In accordance with EN54-16, ISO 7240-16 and BS5839:pt8, all system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally generated pilot tone is available for monitoring impedance on the loudspeaker lines. The IDA8SL Slave supports redundant network cabling as a redundant loop. The system can handle 256 priorities, for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements. 11

IDA8SAB IDA8 Networkable PAVA system SLAVE UNIT A/B zoning Installation Notes 12

IDA8SAB IDA8 Networkable PAVA system SLAVE UNIT A/B zoning Controls and indicators Front Status LEDs Zone LEDs Power LEDs Rear Voltage selector Interconnections Rear Mains input Battery backup input 9 control inputs 8 control outputs 4 analogue audio mic/line inputs (optional) 4 analogue audio line inputs (optional) 2 system LOCAL-network connections 8 amplifier in and outputs 2 connections for back-up amplifiers 2 monitored paging console inputs Certifications and Approvals Region Certifications Europe CE CE 0359 (Intertek) Immunity according to EN50103-4 PAVA EN54-16 certified 2012 Parts Included Quantities Components 1 IDA8SAB Slave unit 1 Power cord 1 Set of mounting brackets for 19 rack 1 Set of connectors 1 Ateis Studio software GUI Technical Specifications Electrical Mains power supply Voltage 115 or 230 VAC ±15%, 50/60 Hz Power consumption 48 W Loudspeaker lines in 8 x 100 V Rated load resistance 20 ohm (100 V) Rated load capacitance 250 nf (100 V) Rated output power (per channel) Loudspeaker lines out 500 W (cont. at 40 C) 8x (A+B) Rated load resistance 20 ohm (100 V) Rated load capacitance 250 nf (100 V) Rated output power (per channel) Mechanical Dimensions (H x W x D) (including brackets) Weight IDA8SAB Mounting Colour rackmount 500 W (cont. at 40 C) 2U, 88 x 483 x 289 mm 5 kg (11 lb) 19 -rackmount RAL7016 Battery power supply Voltage Performance Frequency response 18-26 VDC -3 db @ 20 Hz and 20 khz Environmental Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity 15% to 90% Air pressure 600 to 1100 h Pa Line inputs (OPTIONAL) Ordering Information Connector Frequency response 3-pin phoenix (electronically balanced) +/-3 db @ 20 Hz and 20 khz IDA8SAB-C1 IDA8SAB-C1-IO Slave with NET-C1 card Slave with NET-C1 card & 4 audio inputs & 4 audio outputs S/N THD > 90 dba < 0,1% @ 1 khz IDA8SAB-C1-2I Slave with NET-C1 card & 8 audio inputs Input sensitivity Input impedance 770 mv 20 kohm IDA8SAB-C1-2O Slave with NET-C1 card & 8 audio outputs Line outputs (OPTIONAL) Connector 3-pin phoenix S/N > -85 dbu THD < 0,02% @ 1 khz Signal 770 mv Output impedance < 300 ohm 13

IDA8SAB IDA8 Networkable PAVA system SLAVE UNIT A/B zoning 1. System fault 2. General fault 3. Bypass mode 4. Bypass monitoring 5. Global EVAC 6. EVAC indicators 7. Power 8. Network 9. FAULT indicators 1. Speaker zone outputs (A+B) 2. 2 Back-up amplifier outputs 3. Amplifier 0dB line outputs 4. Bypass mode outputs 5. PDC-ports for secured paging consoles 6. Local network card 7. Audio I/O (optional) 8. Telephone line input 9. Telephone controller 10. 8 Contact outputs 11. 9 Contact inputs 12. 24 VDC slave output 13. 24 VDC back-up input 14. AC power socket 14

IDA8SL IDA8 Networkable PAVA system Low impedance Slave unit IDA8 is a third-generation modular system that complies with current architectural demands requiring IP and/or fibreoptic networking to allow for even the most complex of system designs. IDA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations. Connectivity: Main characteristics Public address and emergency sound system slave unit Fully digital with: 8 audio inputs and 8 audio outputs Two dedicated and monitored PDC-ports for firemen s microphones 2 dedicated audio in and outputs for back-up amplifiers Enhanced loudspeaker line surveillance for lowimpedance installations Simultaneous control and routing of 48 audio channels over dedicated network Equipped as standard with RJ45 network cards for links up to 100 m Optional Fiberoptic cards for links up to 20 km 9 supervised control inputs and 8 control outputs Ethernet interface for configuration, control, diagnostics and logging The IDA8SL Low-Impedance Slave unit houses advanced audio digital signal processing (DSP), matrix control functions and a digital message player, along with amplifier monitoring with hot-swap amplifiers and low-impedance line monitoring. It can support up to two PSS-AS monitored microphone consoles, up to four monitored amplifiers plus two backup amplifiers and paging into 4 different zones per unit with line detection. Each input and output channel is fitted with a wide range of pre-and post-processing devices such as volume controllers, routing mixers and switches, priority and paging components, equalisers, compressors, limiters and delay-lines. IDA8SL Slave units can extend the IDA8 system configuration with an additional 4 output zones and 2 back-up amplifiers. Up to 4 hours of digital messaging can be stored in the unit for live or scheduled playback. Files are uploaded in WAV format from a computer using the ATEÏS Studio system GUI. Several messages can be played simultaneously into different zones: up to 4 from a single IDA8SL or a total of 48 messages across a full IDA8 system with slaves. IDA8SL is easily configured with PC-based ATEÏS Studio global software. Once programmed, the system will run independently without a PC connected. The IDA8SL-Slave operates either on AC mains power or on a 24V DC battery power supply for emergency back-up, with automatic switchover. Both of the power supplies are monitored. Security In accordance with EN54-16, ISO 7240-16 and BS5839:pt8, all system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internally generated pilot tone is available for monitoring impedance on the loudspeaker lines. The IDA8SL Slave supports redundant network cabling as a redundant loop. The system can handle 256 priorities, for calls to hundreds of zones, satisfying even the most complex public address and emergency requirements. Digital storage for up to 4 hours of pre-recorded messages 4 message players EN54-16 certified 15

IDA8SL IDA8 Networkable PAVA system Low impedance Slave unit Installation Notes 16

IDA8SL IDA8 Networkable PAVA system Low impedance Slave unit Controls and indicators Front Status LEDs Zone LEDs Power LEDs Rear Voltage selector Interconnections Rear Mains input Battery backup input 9 control inputs 8 control outputs Optional: 4 analogue audio mic/line inputs Optional: 4 analogue audio line inputs 2 system LOCAL-network connections 4 low-impedance amplifier in and outputs 1 connection for back-up amplifiers 2 monitored paging console inputs 2 connections for back-up amplifiers Certifications and Approvals Region Certifications Europe CE Immunity according to EN50103-4 PAVA EN54-16 certified 2012 Parts Included Quantities Components 1 IDA8SLxx Slave unit 1 Power cord 1 Set of mounting brackets for 19 rack 1 Set of connectors 1 Ateis Studio software GUI Technical Specifications Electrical Mains power supply Voltage 115 or 230 VAC ±15%, 50/60 Hz Power consumption 48 W Battery power supply Voltage 18-26 VDC Performance Frequency response -3 db @ 20 Hz and 20 khz Loudspeaker lines in Rated load resistance 4 x 8 ohm (100 W) RMS Rated load capacitance 250 nf (100 V) Rated output power (per channel) Loudspeaker lines out Rated load resistance Rated output power (per channel) Mechanical Dimensions (H x W x D) for 19 rack use, with brackets 100 W (cont. at 40 C) 1500 W Piek 4 x 19 in-front brackets 40 mm Weight IDA8SL Mounting Colour Environmental Operating temperature Storage temperature 8 ohm (100 W) RMS 100 W (cont. at 40 C) 1500 W Piek 88 x 483 x 300 mm 4.2 kg (9.25 lb) 19 - rackmount RAL7016 Relative humidity 15% to 90% Air pressure -5 ºC to +55 ºC (+23 ºF to +131 ºF) -40 ºC to +70 ºC (-40 ºF to +158 ºF) 600 to 1100 h Pa Line inputs Connector Frequency response S/N THD Input sensitivity Input impedance SPEAKON (electronically balanced) -3 db @ 20 Hz and 20 khz > 90 dba < 0,1% @ 1 khz 770 mv 20 kohm Ordering Information IDA8SL-C1 Slave with NET-C1 card IDA8SL-C1-IO IDA8SL-C1-2I IDA8SL-C1-2O Slave with NET-C1 card & 4 audio inputs & 4 audio outputs Slave with NET-C1 card & 8 audio inputs Slave with NET-C1 card & 8 audio outputs Line outputs Connector S/N THD Signal Output impedance SPEAKON >-85 dbu < 0,02% @ 1 khz 770 m V < 300 ohm 17

IDA8SL IDA8 Networkable PAVA system Low impedance Slave unit 1. System fault 2. General fault 3. Bypass mode 4. Bypass monitoring 5. Global EVAC 6. EVAC indicators 7. Power 8. Network 9. FAULT indicators 1. Backup amplifier output 2. Bypass mode outputs 3. PDC-ports for secured paging consoles 4. Local network card 5. Zone 1 Speaker line output 6. Zone 1 Amplifier output 7. Zone 1 amplifier input 8. Backup amplifier input 9. 8 Contact outputs 10. 9 Contact inputs 11. 24 VDC slave output 12. 24 VDC back-up input 13. AC power socket 18

NET-CX ATEIS Net Secured Audio Network Card NET-C1, 2x RJ45 Port A & Port B NET-C2, 1x RJ45 Port B & 1x fibre Port A NET-C4, 1x fibre Port B & 1x RJ45 Port A NET-C3, 2x fibre Port A & Port B Main characteristics Note Port A = network IN Port B = network OUT Ateis Net audio and data secured network Local-net & Global-net 32 x 32 - nodes in a combined network Low-latency <1ms 48-audio channels Redundant loop architecture 32 bit, 48 khz sampling CAT-5 for up to 100 m Fibreoptic dual-mode for up to 2 km Fibreoptic single-mode for up to 20 km Dedicated network EN54-16 certified ATEÏS Net is a secured (monitored) audio network developed for fast and low-latency audio and data transport over a redundant copper (CAT-5) or fibreoptic network ring. ATEÏS Net has an open-architecture design and interfaces with remote devices such as paging consoles, audio break-in and break-out convertors and room controllers. It is best suited to medium to large-scale installations, such as shop ping malls, retail stores, train stations and airports. ATEÏS Net secured audio network responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations. Functions ATEÏS Net is able to simultaneously transport 48 audio channels (32 bit, 48 khz sampling rate) with a latency <1ms together with the necessary control data over a CAT-5 or fibreoptic dedicated network. For LOCAL and GLOBAL system networking, optional ATEÏS Net networking cards can be installed into the IDA8 Controller and Slave units. Thanks to its loop architecture, the ATEÏS Net audio network is fully redundant. If a problem (line open or shorted) occurs on a loop segment, it will be automatically isolated without affecting system functionality. One IDA8C Controller and up to 31 IDA8S Slaves can be connected together onto one LOCAL network. For systems of more than 32 units, or to link LOCAL networks, the GLOBAL network is used. Up to 32 IDA8C Controllers can be connected on the same GLOBAL network. As network addresses are auto negotiated, network setup is very easy. Once programmed, the system will function independently without a PC having to be connected. IDA8C Controller units can be equipped with both LOCAL and GLOBAL network cards the communication network to be expanded up to 32 x 32 nodes. NET-C1 cards (RJ45 to RJ45) are suitable for installation distances of up to 100m between Controller and Slave and/ or Slave and Slave. For longer installation distances, optional NET-C2, C3 or C4 can be used to extend distances up to 2 km between units in multi-mode or 20 km in single-mode. 19

NET-CX ATEIS Net Secured Audio Network Card Parts Included Quantities 1 1 Components Ateis Net secured audio network card Set of interconnecting ribbon cables 1 Set of mounting pillars Technical Specifications Security In accordance with EN54-16, ISO 7240-16 and BS5839:pt8, all IDA8 system components and peripherals on the ATEÏS Net secured audio network are monitored and reports stored in the IDA8C system controller. The controller monitors the status of all the equipment in the system, reports status changes and stores fault messages for recall either on the controller front-panel display or through the ATEÏS Studio PC-based software. Installation Notes Electrical Battery power supply Voltage Power consumption Audio transport Internal multi-power socket 5 W 48 channels Performance Frequency response Sampling rate Latency Integrity assurance -3 db @ 20 Hz and 22 khz 32 bit / 48 khz < 1 ms Watchdog Indicators Led Led Network active Network present Mechanical Dimensions (H x W x d) 18 x 100 x 150 mm Environmental Operating temperature Storage temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF) -40 ºC to +70 ºC (-40 ºF to +158 ºF) Controls and indicators Front Data running indicator Certifications and Approvals Region Certifications Relative humidity 15% to 90% Air pressure Ordering information 600 to 1100 h Pa NET-C1, RJ45(A)/RJ45(B) (supplied as standard with IDA8 models) NET-C2, ST Multi-mode Fibre (A)/RJ45(B) (Surcharge) NET-C3, ST Multi-mode Fibre(A)/(B) (Surcharge) NET-C4, RJ45(A)/ST Multi-mode Fibre(B) (Surcharge) NET-C3S, ST Single-mode Fibre(A)/(B) (Surcharge) Net-work present indicator Interconnections Front Two system network connections either CAT5 or Fiber-optic or a combination Europe Certification CE 0359 (Intertek) Immunity according to EN50103-4 PAVA EN54-16 certified 2012 20

ATEÏS Studio ATEÏS Studio integrated operation software ATEÏS Studio is a user-friendly graphic user interface designed for intuitive system setup. The PC-based software allows hardware updating, full system configuration and generates the user interface for day-today system operation. Graphical User Interface Configuration software Runs on Windows Assignable access levels with rights management All system and unit parameters can be configured Easy navigation ATEÏS Studio allows complete PAVA/audio systems incorporating a range of devices to be configured, monitored and controlled centrally from a single user interface. ATEÏS Studio supports all IP-based products within the ATEÏS product family such as IDA8, LAP-AS and ECS. The software enables a comprehensive overview of the system and its virtual connections and also offers control and configuration for power amplifiers, paging consoles and remote controllers such as PSS-AS, CD16-AS and URC-AS devices. Diagnosting ATEÏS Studio monitors, controls, logs and reports a range of events. The whole system configuration preset can be stored and reloaded at the press of a button, depending on application. Users can tailor design elements of the graphic user interface or control panels, as well as program automatic sequences of events and create different levels of user access for security and rights management. Diagnostic and logging software Call, fault and general event logging On-line logging function Historical logging Event display priority can be changed Password-protected File transfer software Building ATEÏS Studio provides a complete set of tools and building blocks for real-time control, monitoring and design of an audio system or Voice Evacuation system from paging console to loudspeaker. Detailed information such as signal levels, loudspeaker impedance, pre-recorded messages, amplifier conditions and other parameters can be monitored in real-time. A comprehensive library of tools, control and monitoring elements is provided along with the GUI, including items such as volume control faders, metering, high-level EQ, compression, limiting, auto-gain, noise sensing, mixing, shortcut buttons and display elements. Element behaviour can be fully tailored to suit each application. Built-in file transfer software transfers both data and audio files from the PC to the network controller. PC-based application Supplied together with the network controller Creation of message sets Off-line configuration 21

ATEÏS Studio ATEÏS Studio integrated operation software Access levels Additional security can be added to the software with password-protected layers according to EN 54-16. Multiple users can be created and assigned, each with a unique password and access to specific layers of the GUI. This creates a control surface specific to the needs of system designers and operators at multiple levels. 22

D e l i v e r i n g Y o u r M e s s a g e

Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers IDA8S IDA8SAB Networkable PAVA system Slave Unit A/B-zoning Networkable PAVA system Slave Unit IDA8SL Networkable PAVA system Low impedance Slave Unit ATEÏS Europe B.V. Sydneystraat 42-3047 BP - ROTTERDAM - NETHERLANDS Phone: +31 (0)10 2088690 - Fax: +31 (0)10 2088699 www.ateis-europe.com info@ateis-europe.com ATEÏS reserve the right to change specifications without notice HELPROD.COM - Product pictures, Robert Peek Fotografie - Fotolia