SYNFRAME RL AND SYNFRAME

Similar documents
Handling Technique. SynFrame RL and SynFrame. Modular approach and retraction system for minimally invasive surgery.

Low Profile 3.5 Pelvic System. The comprehensive solution for pelvic fracture fixation.

McCULLOCH. Micro-Discectomy Instruments The premium neurospine retractor system / / / / / / / / / /

Ordering Information. Low Profile 3.5 mm Pelvic System. The comprehensive solution for pelvic fracture fixation.

Modular Structural Parts

Advancing Modularity FIREBIRD SPINAL FIXATION SYSTEM PHOENIX MINIMALLY INVASIVE SPINAL FIXATION SYSTEM

Fibular Distal Plate. Angularly stable screws The distal fibular plate is fixed using Ø 3.5 mm and Ø 3.5/2.7 mm angularly stable screws.

Removal and Installation8

Video Assisted and Thoracoscopic Major Pulmonary Procedures

MatrixNEURO. The next generation cranial plating system.

TIONS INSTRUC TION A RECONSTRUCTION NAIL OPER

Laparoscopy. The cost-effective route to modern surgery. RIWKL-11011_Single_Port_Broschuere_GB_rz.indd 2

Medical Rail Systems 147

If you are missing any of the following items, please contact Stanton Video immediately (602)

VZ-SnapCrane-12 Professional Modular Camera Crane Instruction Manuall

VZ-SnapCrane-16 Professional Modular Camera Crane Instruction Manuall

Rigid endoscopes. Endoscopy with the highest image quality

Halo-5 Microdrive. Users Manual. Microdrive used for manually driving tetrodes for electrophysiology recordings

GH-50. Gimbal Head. You re on steady ground

System Storage EXP3000 Rack Installation Instructions

Further Information can be found at

M40 Microscope User s Manual

July Manual 10-slide disk outdoor viewer

OMM200 and OMM200T. Metallurgical Microscope

Data Fusion Virtual Surgery Medical Virtual Reality Team. Endo-Robot. Database Functional. Database

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Zero Gravity Rig Operating Instructions

TEC APO 200 OWNER S MANUAL

5. Operating instructions: Octagon 200CL

Highlights Edition 2/2018. Cardiovascular Surgery

TABLE OF CONTENTS BASIC INSTRUMENTATION ENDOSCOPES INSTRUMENT STORAGE FORCEPS

CMOS Technology in Otorhinolaryngology

DORO. Cranial Stabilization & Retractor Systems. DORO Simply Better Built Simply More Choices.

Cannulated Screw System. Surgical Technique

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

To connect the AC adapter:

AVT Model Tripod.

Aesculap Sterile Technology Aesculap Universal Storage System. Organisation and protection of surgical instruments

Rotary Microtomes. Tissue Processors. Embedding Centers. Microtomes. Cryostats. Water Bath & Slide Warmer. Staining Systems.

A-dec 586 Ceiling Monitor Mount

Video Assisted Heart Valve Surgery

Catalog Numbers: CMB022, CMB022-AA, CMB022-UP, CMB033, CMB033-AA, CMB033-UP, CMB-CW, CMB-LK

Sterilcontainer Sterilizing Containers Contenedores de Esterilización Container di Sterilizzazione Conteneurs de Stérilisation

Equine, Bovine, Camels

Description and Assembly Instructions

Highlights Edition 1/2018. Oral and Maxillofacial Surgery

Polarization Microscope. Omano OM349P Series. User Guide

Sterilization Cases in stainless steel with silicone inserts

Original Instruments and Implants of the Association for the Study of Internal Fixation AO ASIF

Aesculap Spine Spectrum Brochure

Locking Reconstruction and Mini Plate System. Contourable in three dimensions.

INTERAPID Depth Feet. Brown & Sharpe CENTER FINDER. Model with a flat measuring face. Model with a prismatic measuring face H-16

Highlights Edition, Quarter 3. Laparoscopy

AtRactor. Atraumatic Retraction System. Aesculap Surgical Technologies Surgical Instruments

Replacing the SATA PCI Controller Card

Maintaining E-Series Routers

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

Rack Installation Instructions

C-pan arm USERS INSTRUCTIONS

Unitrac. Retraction & holding system for open & minimally invasive surgery. Aesculap Surgical Technologies - Surgical Instruments

PVS-14 Slide to Side Quick Detach Weapon Mount

PH-03: Clinical Photography Production Checklist With The Sony Cybershot T-9 Digital Camera

Parts Manual Kleen Sweep 32R Rider Sweeper

Maintaining the ERX System

Instruction Manual. B1 Series. Copyright 02/02 Motic Microscopes, European Division

Organisational Kitchen Fittings Drawer and Front Extensions

Microscopic Imaging Research Station (MIRS) Assembly Guide. Version 1.0.0

3D-Welding Table Systems

MicroLab Component Holders

Model No. ET-JPF200BE

Installing System Board Options

Upgrading LVDS Cables Instruction Sheet

FOR PC BOARD TO FLAT CABLE

Rack Installation Instructions

STEP-BY-STEP INSTRUCTIONS FOR BUILDING AN AUTOCOLLIMATOR. TECHSPEC Optical Cage System

Contents. Illumination...GHI-110. Bipolar Forceps...GHI-210. Bipolar Electrodes...GHI-215. Scalpels...GHI-220. Scissors...

MINOP InVent. Offering more for patients through less invasive techniques. Aesculap Neurosurgery

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A MICHELSON INTERFEROMETER. TECHSPEC Optical Cage System

SYSTEM 6 handles. SYSTEM 6 handles.

Ultrasound Stabilisation Headset

Simply the best fixation. 3D articulated arms Innovative high-quality products

G12/G12x USER S MANUAL

Technical Data Sheet Screw Clamps and Universal Clamps

MatrixMANDIBLE TM PLATING SYSTEM OVERVIEW BROCHURE. The next-generation mandible plating system

A-MOD DESKTOP OWNER S MANUAL

STORAGE. WORKTOP Worktop covered with a removable 2 mm ABS plate. HANDLES Metal handle.

IBM. Rack Installation Instructions

Mi50 Inverted Microscope User s Manual. Fein.

Flow Sensor SONOFLOW CO.55

Rack Installation Instructions

Removing and Replacing Parts

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

Blackout Shutter Kits with Breathable Wall Light Traps

Borescopes. Endoscopy with highest image quality

420 SS Bridgeback Reamer

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Rack Installation Instructions

ALL-IN-ONE TMJ Arthroscope

Transcription:

SYNFRAME RL AND SYNFRAME Modular approach ach and retraction system Instruments and implants approved by the AO Foundation. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Image intensifier control This description alone does not provide sufficient background for direct use of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contact your local sales representative or refer to: http://emea.depuysynthes.com/hcp/reprocessing-care-maintenance For general information about reprocessing, care and maintenance of Synthes reusable devices, instrument trays and cases, as well as processing of Synthes non-sterile implants, please consult the Important Information leaflet (SE_023827) or refer to: http://emea.depuysynthes.com/hcp/reprocessing-care-maintenance

Table of Contents Introduction SynFrame RL and SynFrame 2 Set Overview 4 AO Spine Principles 6 Surgical Technique Mounting the Basic System 7 Mounting Soft Tissue Retractors/Muscle Retractors 13 Mounting Bone Levers 15 Mounting Rib Retractors 17 Mounting Light-transmitting Rod and Optics Holder 19 Removal 21 Product Information Sets 23 Bibliography 37 SynFrame RL and SynFrame Surgical Technique DePuy Synthes 1

SynFrame RL and SynFrame Modular approach and retraction system The SynFrame family is composed of several modules, allowing for either a lumbar or a cervical set up. In addition to the Stainless Steel blades (SST), blades made out of radiolucent aluminium alloy (Alu) are also available. Semi-transparent bone levers made out of Titanium Alloy (TAV) complete the system. Optimizing minimally invasive surgery Exposure in the depth of the operating field by Distal expansion capability allows surgeon to work through a small skin incision Enhanced illumination by means of the polyaxial holder for optics and endoscope Stable operating field System attached to both sides of the operating table Precise fixation of the retractors Soft Tissue and Muscle Retractors Alu SST Alu SST 2 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Enhanced visibility Unobstructed view of the operating field: Modules can be positioned freely on the frame Comprehensive overview of the operating field Aluminium and titanium alloy components allow for improved fluoroscopic viewing in comparison to stainless steel components. Broad range of applications All retractors can be combined Different lumbar approaches (anterior, lateral, posterior) Anterior cervical approach Atraumatic retraction Traction forces can be individually adjusted Exact and rapid fixation: Constant traction to protect critical structures Bone Levers Rib Retractors Holder for Optics SST Light-transmitting Rod TAV SST SynFrame RL and SynFrame Surgical Technique DePuy Synthes 3

Set Overview 687.313 Vario Case for SynFrame Basic System (Fixation Components for OR Table), with Lid, without Contents SynFrame Basic System 187.310 SynFrame Basic System in Vario Case 687.319 Vario Case for SynFrame Basic System (Fixation Components for Ring), with Lid, without Contents 4 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

01.609.102 Set SynFrame RL, lumbar 01.609.101 Set SynFrame RL, cervical SynFrame RL (radiolucent) Optional Retractors for SynFrame RL, without Vario Case 187.316 SynFrame Soft Tissue Retractors in Vario Case 187.322 SynFrame Bone Levers in Vario Case SynFrame (Stainless Steel) 187.325 SynFrame Muscle Retractors in Vario Case Optional Retractors for SynFrame, without Vario Case SynFrame RL and SynFrame Surgical Technique DePuy Synthes 5

AO Spine Principles The four principles to be considered as the foundation for proper spine patient management underpin the design and delivery of the Curriculum: Stability Alignment Biology Function. 1,2 Stability Stabilization to achieve a specific therapeutic outcome axial sagittal coronal Alignment Balancing the spine in three dimensions Biology Etiology, pathogenesis, neural protection, and tissue healing Function Preservations and restoration of function to prevent disability Copyright 2012 by AOSpine 1 Aebi et al (1998) 2 Aebi et al (2007) 6 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Mounting the Basic System SynFrame is a surgical approach and retraction system. It consists of a basic system (basic construction) and modules that are specially designed for the respective requirements and needs of various indications and/or approach techniques (eg. anterior lumbar approach for total disc replacement). For further details and indications please refer to the corresponding technique guides. The illustrations for the assembly technique of the SynFrame basic system will be described with reference to a supine patient (anterior lumbar approach in this case). In other patient positions, the SynFrame basic system is always constructed in the same sequence following the same principles. Assembly on the operating table and over the surgical approach needs to be adapted to the patient position. Sterile assembly of SynFrame To separate the sterile area from the unsterile area on the operating table, sterile cover tubing or a corresponding cover with special fenestrated drapes is recommended. Since the insulated holding base (387.346) can be sterilized, it can also be used in the covered area (for example over the sterile cover). Note: During assembly, check if the holding base is firmly affixed to the guide rails of the operating table and does not move. The clamping mechanism for the holding base can damage special cover materials (such as Goretex) in certain circumstances. SynFrame RL and SynFrame Surgical Technique DePuy Synthes 7

Mounting the Basic System 1 Mount the holding base Tightly screw an insulated holding base (387.346) to the guide rails, diagonally to each other. Offset the insulated holding base to the side so that: a. The retaining ring B 300 mm (387.336) can be affixed cranially and caudally between the holding base on the operating table (required space: at least 400 mm), b. The retaining ring can be positioned laterally and cranially or caudally between the angled rods (387.344) held in the holding bases depending on the planned surgery, c. The freedom of movement and the work area of the surgeon and assistants are not restricted. If this construction is not possible due to the patient s position, the approach or the design of the operating table, always assemble the basic system so that it, and the retaining ring in particular, is held securely. Note: The SynFrame holding base for the operating table insulates the entire SynFrame system from the grounded operating table and meets safety standards IEC 60601-1 and 2-2, VDE 0750 part 2, and VDE 0753 for ground-free patient positioning. Ground-free patient positioning with the SynFrame is only guaranteed by the manufacturer when original SynFrame holding bases are used. Damaged holding bases or those with an expired product expiration date may not be used. 8 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

2 Insert the guiding tubes into the holding base Insert both guiding tubes (387.343) into the holding bases at the same height in relation to the positioned patient, and clamp them with the clamp (1). The outer diameter of the bottom part of the guiding tube mates with the guide of the holding bases. The larger outer diameter of the top part of the guiding tube acts as a stop so that the tightening bar (2) of the guiding tube does not touch the metal parts of the operating table or the insulated parts of the holding base which would eliminate the effects of the insulation. 2 1 3 Fix the angled rods in the guiding tubes Insert the angled rods (387.344) into the guiding tubes on both sides of the operating table, and affix them approximately 5 10 cm from the patient. 4 Affix tube-to-tube clamps on the angled rods Loosely insert the tube-to-tube clamps (387.353) onto the two angled rods. SynFrame RL and SynFrame Surgical Technique DePuy Synthes 9

Mounting the Basic System 5 Mount retaining ring The retaining ring (387.336) consists of the two half-rings (387.337). To mount the retaining ring, insert the two halfrings over the guide pins. Tighten the side set screws with the large hexagonal screwdriver (314.270). Alternative Mount the retaining ring with an extension The round retaining ring B 300 mm can be enlarged to form an oval retaining ring 400 mm long. Insert the extensions (387.338) over the guide pins onto the half rings on both sides, and tighten them with the large hexagonal screwdriver. 6 Mount the connection rods on the retaining ring Open the clamps of the two connecting rods (387.345). Insert the retaining ring into the two clamps, and screw on the clamps with the large hexagonal screwdriver so that the connecting rods can still freely slide on the retaining ring. The retaining ring can thereby be optimally adapted to the placement of the positioned patient. 11 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

7 Affix the retaining ring over the patient Insert the retaining ring with the connecting rods into the tube-to-tube clamps on both sides, and affix it over the operative field. Move the retaining ring as close as possible to the operative field so that the distance between the instruments later placed on the retaining ring and the operative field is as small as possible. If necessary, lower the angled rods further into the guiding tube. Adjust the optimum position, and tighten the tube-to-tube clamps (1) and screws in the clamps of the connecting rods (2). Check the stability of the connecting elements to prevent undesirable movement during surgery. Precaution: Do not lean against the basic SynFrame system. This could overload the construction, move individual parts of the SynFrame, and displace soft tissue and/or blood vessels. When moving the patient, monitor the position of the instruments in situ to avoid potential harm or dislocation of soft tissue and/or vessels. 1 2 2 1 Alternative way to mount the basic system The sequence of the steps can also be varied as follows: 1. First affix the connecting rods to the tube-to-tube clamps. 2. Then insert the mounted retaining ring into the opening of the connecting rods. (see steps 5 7) SynFrame RL and SynFrame Surgical Technique DePuy Synthes 11

Mounting the Basic System 8 Mount the clamp on the retaining ring The clamps (387.347) serve as a holder for the different SynFrame instruments on the retaining ring. They are construction elements of the basic system. Check if the clamp is completely open before snapping it on. Snap the clamp with the larger of the two slotted openings onto the retaining ring without tightening it. Make sure that the clamp is affixed from the outside since the holding force of the clamp is greatest there given its construction. 11 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Mounting Soft Tissue Retractors/ Muscle Retractors Soft tissue retractors are for retraction of soft tissues and blood vessels. Muscle retractors are for retraction of muscles of the sub cutaneous tissues and the skin. 1 Insert the retractor in the guide rod From the side, insert the selected retractor into the adjustable clamp of the guide rod (387.358) and rotate it 90 in the retaining ring. This holds the retractor in the guide, but the retractor remains fully movable. Soft tissue retractor Muscle retractor 2 Position the retractor Position the retractor in the operative site, and clamp the guide rod of the retractor in the smaller slotted opening of the clamp. Make sure that the clamp is completely opened. The retractor is freely moveable on the retaining ring in every plane as long as the clamp is not screwed tight. After the retractor is definitively positioned, stably affix the clamp by screwing tight. Precaution: The retractors can apply a relatively large force to the soft tissue and vessels. For this reason, loosen the retractors from time to time to prevent pressure necrosis. Precaution: Always align the retractor directly with the direction of pull of the guide rod so that the entire width of the retractor serves as a seat for the soft tissue (a). The pointed edge of the retractor may never contact the soft tissue (b); this can cause pressure necrosis and cause burns if it unintentionally contacts the coagulation device. a b SynFrame RL and SynFrame Surgical Technique DePuy Synthes 11

Mounting Soft Tissue Retractors/Muscle Retractors 3 Enlarging the work area Loosen the setscrew in the adjustable clamp of the guide rod with socket wrench 6.0 mm (388.140). The adjustable tip of the affixed retractor can then be pivoted on its axis, and the visible working area can be enlarged. Precaution: If the socket wrench is used as a lever, there is a danger of too much force being transmitted to the retractor. This can damage the retracted structures (overstretching the vessels and soft tissue). It is therefore recommendable to guide the moveable retractor with your finger. The tension can be adjusted and distributed safely for soft tissue. 4 Retraction For retraction, release the clamps until the guide rod can be moved. Carefully pull the guide rod and the retractor until the desired retraction is achieved. Then screw the clamp tight in this position. 11 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Mounting Bone Levers For retracting soft tissue, blood vessels and muscular structures. 1 Anchor the bone lever in the bone Position and anchor the bone lever in the bone with the aid of a hammer. Warning: Carefully insert the bone lever into the operative site and hammer it in under visual observation. The sharp tip can cause tissue damage. 2 Affix the bone lever to the holder Enlarge the operative site by pulling back the bone lever, and hang the lever over the ball of the holder (387.356). Patient movement can be compensated by the ball joint and the flexible end of the holder. SynFrame RL and SynFrame Surgical Technique DePuy Synthes 11

Mounting Bone Levers 3 Clamp the bone lever holder in the clamp Clamp the bone lever holder in the smaller slotted opening of the clamp. As long as the clamp is not screwed tight, the holder for the bone lever can still be freely moved. 4 Retraction Carefully pull the holder for the bone lever in the not-fullytightened clamp together with the retractor until the desired retraction is achieved. Then screw the clamp tight in this position. 11 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Mounting Rib Retractors For retracting ribs for a thoracic approach. 1 Position the rib retractor Place the rib retractor into the desired position. 2 Clamp the rib retractor in the clamp Clamp the rib retractor in the smaller slotted opening of the clamp. As long as the clamp is not screwed tight, the rib retractor can still be freely moved. SynFrame RL and SynFrame Surgical Technique DePuy Synthes 11

Mounting Rib Retractors 3 Retraction Carefully pull the rib retractor in the not-fully-tightened clamp until the desired retraction is achieved. Then screw the clamp tight in this position. 11 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Mounting Light-transmitting Rod and Optics Holder Mount the light-transmitting rod The light-transmitting rod (387.362) is equipped with an ACM connection. Use the required adapter (Storz or Wolf) depending on the available fiber-optic cable system. Following the same procedure as with the guide rods for retractors, clamp the light-transmitting rod in the small slotted opening of the clamp. As with the guide rods, it is recommended to position the light-transmitting rod so that the working area is directly illuminated deep in the operative site without hindering surgery. Stably fix the light-transmitting rod on the frame by tightening the clamp. Precaution: Together with the high-power light sources, temperatures can arise at the light-source end and instrument end of the light-transmitting rod that can cause burns. In addition, high- energy light can increase the tissue temperature. For this reason, avoid direct contact with tissue, and maintain a distance between the tissue and distal end of the rod of at least 10 mm when affixing the SynFrame light-transmitting rod. Do not place the light-transmitting rod on flammable objects such as textiles (surgical drapes). Never look into the end of the connected light-transmitting rod (blinding hazard). SynFrame RL and SynFrame Surgical Technique DePuy Synthes 11

Mounting Light-transmitting Rod and Optics Holder Mount the optics holder Tighten the set screw to affix the holder for optics (387.365) facing outward on the ring so that the operative field remains free. Fix the polyaxial mechanism of the optics holder in the desired position using the central adjusting screw. The optics holder is designed for optics with a diameter of 4 mm or 10 mm. 22 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Removal Remove SynFrame SynFrame is removed in reverse sequence. The entire construction (retaining ring and connecting rods) above the patient can be quickly removed from the operative area by completely screwing out from the clamp the locking screws of the tube-to-tube clamps (387.353) on the angled rods. SynFrame RL and SynFrame Surgical Technique DePuy Synthes 22

Removal Using SynFrame with devices from other manufacturers Precaution: If SynFrame is used with high-frequency or electromedical surgical equipment, make sure that this equipment does not contact the metal parts of the SynFrame. The SynFrame manufacturer refers to the guidelines and instructions associated with the high-frequency or electromedical surgical device manufacturers but also recommends the use of insulating and grounding techniques. 22 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Sets SynFrame Basic System 187.310 SynFrame Basic System in Vario Case 687.313 Vario Case for SynFrame Basic System 1 (Fixation Components for OR Table), with Lid, without Contents 687.319 Vario Case for SynFrame Basic System 1 (Fixation Components for Ring), with Lid, without Contents Content of 687.313 387.346 SynFrame Holding Base, insulated, 2 for OR Table, dark blue 387.343 SynFrame Guiding Tube, 2 for Angled Rod No. 387.344, for Basic System 387.344 SynFrame Angled Rod, 2 for Basic System 387.353 SynFrame Tube-to-Tube Clamp, 2 for Basic System Content of 687.319 387.345 SynFrame Connecting Rod, 2 for Holding Rings Nos. 387.336 and 387.337, for Basic System 387.336 SynFrame Retaining Ring B 300 mm, 1 two-part, complete, for Basic System 387.347 SynFrame Clamp for Holding Ring 8 No. 387.336, dark blue 387.358 SynFrame Guide Rod 6 with adjustable clamp, for Soft Tissue and Muscle Retractors 314.270 Screwdriver, hexagonal, large, 1 B 3.5 mm, with Groove, length 245 mm 388.140 Socket Wrench 6.0 mm, 1 with straight handle SynFrame RL and SynFrame Surgical Technique DePuy Synthes 22

Sets Optional for 187.310 387.337 SynFrame Half-Ring, for Holding Ring 1 No. 387.336, for Basic System 387.338 SynFrame Extension, 2 for Nos. 387.336 and 387.337 387.361 SynFrame Guide Rod 6 with adjustable clamp, with Snap-in Locking, for Soft Tissue and Muscle Retractors 387.362 SynFrame Light-transmitting Rod 1 387.365 Holder for Optics B 10.0 and 4.0 mm, 1 polyaxial, for SynFrame Basic System Included in 387.362 387.398 Adapter type Storz, for No. 387.362 1 387.399 Adapter type Wolf, for No. 387.362 1 22 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

SynFrame RL 01.609.102 Set SynFrame RL, lumbar Vario Case 68.609.102 Vario Case For SynFrame, radiolucent, lumbar, without Contents 1 Bone Levers 03.609.816 SynFrame Bone Lever, semi-transparent, 2 width 8 mm, length 160 mm 03.609.819 SynFrame Bone Lever, semi-transparent, 2 width 8 mm, length 190 mm 03.609.916 SynFrame Bone Lever, semi-transparent, 2 width 18 mm, length 160 mm 03.609.919 SynFrame Bone Lever, semi-transparent, 2 width 18 mm, length 190 mm 387.356 Holder for SynFrame Bone Lever 6 Retractors 03.609.006 SynFrame Soft Tissue Retractor, 4 radiolucent, blunt, width 25 mm, length 60 mm, Aluminium 03.609.008 SynFrame Soft Tissue Retractor, 4 radiolucent, blunt, width 25 mm, length 80 mm, Aluminium 03.609.010 SynFrame Soft Tissue Retractor, 4 radiolucent, blunt, width 25 mm, length 100 mm, Aluminium 03.609.012 SynFrame Soft Tissue Retractor, 4 radiolucent, blunt, width 25 mm, length 120 mm, Aluminium 03.609.014 SynFrame Soft Tissue Retractor, 4 radiolucent, blunt, width 25 mm, length 140 mm, Aluminium 03.609.016 SynFrame Soft Tissue Retractor, 4 radiolucent, blunt, width 25 mm, length 160 mm, Aluminium SynFrame RL and SynFrame Surgical Technique DePuy Synthes 22

Sets 01.609.101 Set SynFrame RL, cervical Vario Case 68.609.101 Vario Case for SynFrame, radiolucent, 1 cervical, with Lid, without Contents 387.333 SynFrame Extension, with Joint 1 387.334 SynFrame Extension, with Joint, 1 with Snap-in Locking 387.335 SynFrame Holding Ring B 240 mm, 1 two-part, complete Bone Levers 03.609.810 SynFrame Bone Lever, semi-transparent, 2 width 8 mm, length 100 mm 03.609.813 SynFrame Bone Lever, semi-transparent, 2 width 8 mm, length 130 mm 03.609.910 SynFrame Bone Lever, semi-transparent, 2 width 18 mm, length 100 mm 03.609.913 SynFrame Bone Lever, semi-transparent, 2 width 18 mm, length 130 mm 387.356 Holder for SynFrame Bone Lever 6 22 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Retractors Blunt/slim 03.609.204 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 15 mm, length 40 mm, Aluminium 03.609.206 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 15 mm, length 60 mm, Aluminium 03.609.208 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 15 mm, length 80 mm, Aluminium 03.609.210 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 15 mm, length 100 mm, Aluminium 03.609.212 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 15 mm, length 120 mm, Aluminium Blunt/normal 03.609.004 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 40 mm, Aluminium 03.609.006 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 60 mm, Aluminium 03.609.008 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 80 mm, Aluminium 03.609.010 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 100 mm, Aluminium 03.609.012 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 120 mm, Aluminium SynFrame RL and SynFrame Surgical Technique DePuy Synthes 22

Sets Small teeth/slim 03.609.404 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 15 mm, length 40 mm, Aluminium 03.609.406 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 15 mm, length 60 mm, Aluminium 03.609.408 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 15 mm, length 80 mm, Aluminium 03.609.410 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 15 mm, length 100 mm, Aluminium 03.609.412 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 15 mm, length 120 mm, Aluminium Small teeth/normal 03.609.304 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 25 mm, length 40 mm, Aluminium 03.609.306 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 25 mm, length 60 mm, Aluminium 03.609.308 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 25 mm, length 80 mm, Aluminium 03.609.310 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 25 mm, length 100 mm, Aluminium 03.609.312 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 25 mm, length 120 mm, Aluminium 22 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Big teeth/slim 03.609.604 SynFrame Muscle Retractor, radiolucent, 2 width 15 mm, length 40 mm, Aluminium 03.609.606 SynFrame Muscle Retractor, radiolucent, 2 width 15 mm, length 60 mm, Aluminium 03.609.608 SynFrame Muscle Retractor, radiolucent, 2 width 15 mm, length 80 mm, Aluminium 03.609.610 SynFrame Muscle Retractor, radiolucent, 2 width 15 mm, length 100 mm, Aluminium 03.609.612 SynFrame Muscle Retractor, radiolucent, 2 width 15 mm, length 120 mm, Aluminium Big teeth/normal 03.609.504 SynFrame Muscle Retractor, radiolucent, 2 width 25 mm, length 40 mm, Aluminium 03.609.506 SynFrame Muscle Retractor, radiolucent, 2 width 25 mm, length 60 mm, Aluminium 03.609.508 SynFrame Muscle Retractor, radiolucent, 2 width 25 mm, length 80 mm, Aluminium 03.609.510 SynFrame Muscle Retractor, radiolucent, 2 width 25 mm, length 100 mm, Aluminium 03.609.512 SynFrame Muscle Retractor, radiolucent, 2 width 25 mm, length 120 mm, Aluminium SynFrame RL and SynFrame Surgical Technique DePuy Synthes 22

Sets Optional for SynFrame RL Lumbar retractors Blunt/normal 03.609.105 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 50 mm, Aluminium 03.609.107 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 70 mm, Aluminium 03.609.018 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 180 mm, Aluminium 03.609.020 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 200 mm, Aluminium 33 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Blunt/wide 03.609.024 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 40 mm, Aluminium 03.609.025 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 50 mm, Aluminium 03.609.026 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 60 mm, Aluminium 03.609.027 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 70 mm, Aluminium 03.609.028 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 80 mm, Aluminium 03.609.030 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 100 mm, Aluminium 03.609.032 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 120 mm, Aluminium 03.609.034 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 140 mm, Aluminium 03.609.036 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 160 mm, Aluminium 03.609.038 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 180 mm, Aluminium 03.609.040 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 50 mm, length 200 mm, Aluminium SynFrame RL and SynFrame Surgical Technique DePuy Synthes 33

Sets Cervical retractors Blunt/slim 03.609.205 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 15 mm, length 50 mm, Aluminium 03.609.207 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 15 mm, length 70 mm, Aluminium Blunt/normal 03.609.105 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 50 mm, Aluminium 03.609.107 SynFrame Soft Tissue Retractor, 2 radiolucent, blunt, width 25 mm, length 70 mm, Aluminium Small teeth/slim 03.609.405 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 15 mm, length 50 mm, Aluminium 03.609.407 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 15 mm, length 70 mm, Aluminium Small teeth/normal 03.609.305 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 25 mm, length 50 mm, Aluminium 03.609.307 SynFrame Soft Tissue Retractor, 2 radiolucent, small teeth, width 25 mm, length 70 mm, Aluminium 33 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Big teeth/slim 03.609.605 SynFrame Muscle Retractor, radiolucent, 2 width 15 mm, length 50 mm, Aluminium 03.609.607 SynFrame Muscle Retractor, radiolucent, 2 width 15 mm, length 70 mm, Aluminium Big teeth/normal 03.609.505 SynFrame Muscle Retractor, radiolucent, 2 width 25 mm, length 50 mm, Aluminium 03.609.507 SynFrame Muscle Retractor, radiolucent, 2 width 25 mm, length 70 mm, Aluminium SynFrame RL and SynFrame Surgical Technique DePuy Synthes 33

Sets SynFrame (Stainless Steel) 187.316 SynFrame Soft Tissue Retractors in Vario Case, Stainless Steel Vario Case 687.316 Vario Case for SynFrame Soft Tissue 1 Retractors, Stainless Steel, with Lid, without Contents Content of 187.316 387.391 SynFrame Soft Tissue Retractor, 4 width 23 mm, length 60 mm 387.392 SynFrame Soft Tissue Retractor, 4 width 23 mm, length 80 mm 387.393 SynFrame Soft Tissue Retractor, 4 width 23 mm, length 100 mm 387.394 SynFrame Soft Tissue Retractor, 4 width 23 mm, length 120 mm 387.395 SynFrame Soft Tissue Retractor, 4 width 23 mm, length 140 mm 387.396 SynFrame Soft Tissue Retractor, 4 width 23 mm, length 160 mm 33 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

187.322 SynFrame Bone Levers in Vario Case, Stainless Steel Vario Case 687.322 Vario Case for SynFrame Bone Levers, 1 Stainless Steel, with Lid, without Contents Content of 687.322 387.356 Holder for SynFrame Bone Lever 6 399.201 SynFrame Bone Lever, width 8 mm, 3 length 100 mm 399.202 SynFrame Bone Lever, width 8 mm, 3 length 130 mm 399.203 SynFrame Bone Lever, width 8 mm, 3 length 160 mm 399.209 SynFrame Bone Lever, width 18 mm, 3 length 130 mm 399.211 SynFrame Bone Lever, width 18 mm, 3 length 150 mm 399.212 SynFrame Bone Lever, width 18 mm, 3 length 170 mm 399.213 SynFrame Bone Lever, width 18 mm, 3 length 190 mm SynFrame RL and SynFrame Surgical Technique DePuy Synthes 33

Sets 187.325 SynFrame Muscle Retractors in Vario Case, Stainless Steel Vario Case 687.325 Vario Case for SynFrame Muscle 1 Retractors, Stainless Steel, with Lid, without Contents Content of 687.325 387.372 SynFrame Muscle Retractor, 2 width 23 mm, length 20 mm 387.373 SynFrame Muscle Retractor, 2 width 23 mm, length 40 mm 387.374 SynFrame Muscle Retractor, 4 width 23 mm, length 60 mm 387.375 SynFrame Muscle Retractor, 4 width 23 mm, length 80 mm 387.376 SynFrame Muscle Retractor, 4 width 23 mm, length 100 mm 387.377 SynFrame Muscle Retractor, 2 width 23 mm, length 120 mm Optional Rib Retractors for SynFrame (Stainless Steel) 387.451 SynFrame Rib Retractor, 2 width 30 mm, length 40 mm 387.452 SynFrame Rib Retractor, 2 width 40 mm, length 50 mm Optional Muscle Retractors for SynFrame (Stainless Steel) 387.378 SynFrame Muscle Retractor, 2 width 23 mm, length 140 mm 387.379 SynFrame Muscle Retractor, 2 width 23 mm, length 160 mm Optional Soft Tissue Retractor for SynFrame (Stainless Steel) 387.397 SynFrame Soft Tissue Retractor, 4 width 23 mm, length 180 mm 33 DePuy Synthes SynFrame RL and SynFrame Surgical Technique

Bibliography Aebi M, Thalgott JS, Webb JK (1998): AO ASIF Principles in Spine Surgery. Berlin: Springer. Aebi M, Arlet V, Webb JK (2007): AOSpine Manual (2 vols), Stuttgart, New York: Thieme SynFrame RL and SynFrame Surgical Technique DePuy Synthes 33

DSEM/SPN/0616/0530 09/16 Synthes GmbH Eimattstrasse 3 Not all products are currently available in all markets. 4436 Oberdorf Switzerland This publication is not intended for distribution in the USA. Tel: +41 61 965 61 11 Fax: +41 61 965 66 00 All surgical techniques are available as PDF files at www.depuysynthes.com www.depuysynthes.com/ifu 0123 DePuy Synthes Spine, a division of Synthes GmbH. 2016. All rights reserved. 036.000.065