Indoor unit movement function
1. Changes from the previous operation Overview It was not able to travel the indoor unit after the plumbing design in the version in front, but enabled the movement of the indoor unit after the plumbing design in this version. We have changed the cooling only switching method of the indoor unit. Changes 1)Change of the indoor unit move button. (See the 2-1. Method of operation(movement of the indoor unit) For operation. ) [Conventional] [Change] [Conventional] [Change] 2) Add a pop-up screen of the indoor unit movement. (See the 2-1. Method of operation(movement of the indoor unit) For operation. ) 3)Changing the method of switching to cooling only. (See the "2-2. Method of operation(switching to the cooling only indoor unit.)" For operation. ) [Conventional] Press the cooling only switching button to select RB-unit. [Change] Press the cooling only switching button to select the indoor unit. 1
2-1. Method of operation(movement of the indoor unit) 1Press the indoor unit move button. The changed function Also be made to design the pipes can be moved in the indoor unit. All series subject to the VRF. Pop-up menu appears on the screen. New function 2Select the move to the indoor unit, and press the top and bottom of the move button. 2
Method of operation(movement of the indoor unit) 3Press the Check button. If you do not press the check button, OK button is not enabled. If an error by pressing the check button has occurred, and displays an error message on the screen. (See the "2-3. Method of operation(how to cope in the event of an error.)" For operation. ) 4Press the OK button. To confirm the settings and return to the piping screen. When you press the OK button in a state in which the error has occurred, the setting is released to return to the piping screen. When moving the indoor unit in the RB-Multi. If the following events by moving the indoor unit occurs, a pop-up menu appears on the screen. - Overall connection capacity (MAX value) is OK but, if the connection capacity of the port (MAX value) of NG. (See the "2-4. Method of operation(pop-up screen of the RB-Multi.)" For operation. ) Press the Cancel button. Setting will be canceled and it will return to the piping screen. 3
2-2. Method of operation(switching to the cooling only indoor unit.) 1Select the indoor unit, and press the switch button. The changed function The indoor unit with multiple selections can not be switched to the cooling only indoor unit. Please the indoor unit to select one by one. Indoor unit switches to cooling only. 5
2-3. Method of operation(how to cope in the event of an error.) Error display screen 1It moves the indoor unit of where the error occurred. Nature of the error, please message reference. Display of where the error occurred. 2Press the Check button. Error will be canceled. Display of error messages. 3 Press the OK button. To confirm the settings and return to the piping screen. Press the Cancel button. Setting will be canceled and it will return to the piping screen. 5
Method of operation(how to cope in the event of an error.) Error display screen 1Press the OK button in the error state. The indoor unit is the moved state. Error location of the design is released to return to the piping screen. (Release such as headers and RB-Multi.) Display of where the error occurred. Display of error messages. 2Make again piping design a piping screen. Design, such as a header or RB-Multi. Indoor unit is moved, the state in which the header (setting example) is released. 5
Method of operation(how to cope in the event of an error.) Error display screen 1Press the Cancel button in the error state. Setting will be canceled and it will return to the piping screen. Display of where the error occurred. Display of error messages. The indoor unit before moving state. 5
2-4. Method of operation(pop-up screen of the RB-Multi.) 1Press the OK button in the error state. Show pop-up screen for the indoor unit recombination of RB-Multi. Display of where the error occurred. Display of error messages. 2Choose the indoor unit from the port that is beyond the connection limit. 3It moves the indoor unit to another port. 4Press the OK button. To confirm the move, to return to the piping screen.(see next page) Drag and drop 4
Method of operation(pop-up screen of the RB-Multi.) If you press the OK button after recombinant State were recombinant in the indoor unit. 4
Method of operation(pop-up screen of the RB-Multi.) 1Press the OK button in the error state. Show pop-up screen for the indoor unit recombination of RB-Multi. Display of where the error occurred. Display of error messages. 2Press the Release button. Release the RB-Multi to return to the piping screen. (See next page) 4
Method of operation(pop-up screen of the RB-Multi.) If you press the release button. State where the RB-Multi is released 4
End