Installation Guide. Avigilon ACM Embedded Controller

Similar documents
VertX EVO V1000 Installation Guide Barranca Parkway Irvine, CA USA. July 2011 Document Number: Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX EVO V2000. Installation Guide Barranca Parkway Irvine, CA USA. April 2012 Document Number: Rev A.2

Quick Installation Guide

VertX. V100, V200, V300, V1000, and V2000 Installation Guide Barranca Parkway Irvine, CA USA

Edge Device with Brivo ACS Plug-in for WebServices and OnSite SE. Quick Start Guide

Installing and Configuring Rialto Analytic Appliances

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Quick Start Installation Guide

TruPortal Dual Door Interface Module Quick Reference

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

Installation Instructions

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

istar Pro Installation Guide

GV-AS200 Controller. Hardware Installation Guide

Connecting a Cisco Output Module

Connecting a Cisco Input Module

6222 Two Door Module Technical Operations Manual

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Suprex RS-485 SPX-7500 Wired Reader-Extender

Installation Instructions for UL Rev A

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Zodiac WX QUICK START GUIDE

Installation & Operation Guide

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Home automation hub installation and setup guide

Installation and Configuration Guide

Quick Start Installation Guide

MR51e Reader Interface

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

emerge Essential Access Control System

Quick Start Installation Guide

Perle SMI Media Converter Installation Guide

Quick Start Installation Guide

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

SINGLE READER EXPANSION MODULE

USB 2.0 CAT5E/6/7 EXTENDER

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Next Gen Sarix Enhanced IXE Series Box Cameras

ACTpro Single Door IP Controller. Operating & Installation Instructions

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

EasyIO FW 08VUser Reference

MR52 READER INTERFACE

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

ACTpro 1500 Single Door IP Controller

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Two Door Controller GEN-045

Connecting a Cisco Reader Module

Manual Version: V1.00. Video Decoder Quick Guide

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

Gigabit Ethernet Switch. Quick Installation Guide MS400834M

InnoMedia ipbx-400. Quick Install Guide.

BRIVO ACS300 INSTALLATION MANUAL 11/22/2017

User Guide. Avigilon Camera Configuration Tool

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

4100/4120-Series and 4010ES Relay Modules Installation Instructions

hdpv.org Ampt Communications Unit Installation Manual D

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

RMB Peripheral Units Installation Guide

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

1.0 Wiring and Layout Diagrams

YSOFT SAFEQ TERMINAL PROFESSIONAL 3.8 USER S GUIDE 1

Intelli-M eidc Quick Start Guide. infinias

Brivo ACS300 (A/E/S) Installation Manual. Rev 1

CLIQ.mini Installation and Setup Guide

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

C5S120 Installation and Connection Guide

Infosystem Remote Touchscreen Installation Instructions

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

The MSM335 is a Wi-Fi Alliance authorized Wi-Fi CERTIFIED product. The Wi-Fi CERTIFIED Logo is a certification mark of the Wi-Fi Alliance.

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

INSTALLATION INSTRUCTIONS

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Documentation on all Paxton products can be found on our web site -

Hardware Installation

EAGLE-200. Intelligent Control Gateway. User Manual

Ethernet Interface Module

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

IEI emerge MicroNode Install and Setup Guide. Contents

USB 3.1 CAT6A/7 EXTENDER

Touchstone WECB460 Wi-Fi MoCA Bridge

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Cardax FT Controller 3000

PR402 v2.0 Installer Manual Rev.C

Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001

DDW36A Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

BACnet Router Start-up Guide

IPassan Installation guide

Omega 4K / UHD Three-Input Switcher for HDMI and USB-C with HDBaseT and HDMI Outputs

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

Transcription:

Installation Guide Avigilon ACM Embedded Controller

2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM are trademarks of Avigilon Corporation. HID, VertX, V100, V200 and V300 are registered trademarks of HID Global Corporation. Other product names mentioned herein may be the trademarks of their respective owners. The absence of the symbols and in proximity to each trademark in this product or its packaging is not a disclaimer of ownership of the related trademark.20160527 This document has been compiled and published covering the latest product descriptions and specifications. The contents of this document and the specifications of the products discussed herein are subject to change without notice. Neither Avigilon Corporation nor any of its affiliated companies guarantees the completeness or accuracy of the information contained in this document and is not responsible for your use of, or reliance on, the information. Avigilon Corporation shall not be responsible for any damages (including consequential damages) caused by reliance on the information presented herein. Avigilon Corporation http://www.avigilon.com PDF-ACMEC-INSTALL Revision: 3 - EN 20160527 2

Regulatory All National and local Electrical codes apply. This equipment is intended to be powered from a limited power source output of a previously certified power supply. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Class A Digital Devices FCC Compliance Statement: This equipment has been tested and found to comply with the limits for a Class. A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canada Class A CE Mark Europe (EU) C-Tick Australia and New Zealand VCCI Japan NCC Taiwan SRRC China IDA Singapore KCC Korea UL Recognized Component (UL294 and UL1076) RoHS compliant 3

Table of Contents Introduction 1 Package Contents 1 Specifications 1 Product Specification 1 Max. Cable Length 1 Installation 3 Preparing for the Installation 3 Mounting the Controller 3 Wiring the Controller 4 Accessing ACM Embedded ControllerApplication for the First Time 7 By Virtual Port 8 By Host Name 8 Changing the IP Address or Hostname 8 Configuring ACM Embedded Controller 9 Troubleshooting 10 Replacing the Controller Battery 10 Restoring the Factory Default Network Settings 10 Configuring Firewall Access 12 Power LED Behavior 12 After bootup 12 During bootup 12 Comm LED Behavior 13 Configuration Checklist 14 Installation Worksheet 15 4

Introduction The Avigilon ACM Embedded Controller is a controller embedded with the Avigilon ACM Embedded Controller application to provide a flexible and scalable platform for an economic and high performance access control system. The controller uses a standard TCP/IP network to connect downstream controllers and door hardware together. While the ACM Embedded Controller application allows you to effectively control access at each entry point. Package Contents ACM Embedded Controller 4 x Mounting screws 8 x 2.2K Ohm EOL resistors NOTE: One or more HID VertX V100 interface panels are required when installing a ACM Embedded Controller controller. Specifications Product Specification Feature Power Supply Maximum current at 12-24 VDC per unit Average operating current at 12 VDC Operating temperature range Humidity SD card slot USB port Specification 12-24 VDC 1 Amp 210 ma 0-49 C (32-120 F) 5-85% non-condensing Reserved for future use Reserved for future use Max. Cable Length Cable Type Length Recommended Cable RS-485 * Input Circuits Output Circuits * Wiegand 1 220 m (4 000 feet) to host 150 m (500 feet) 150 m (500 feet) 150 m (500 feet) to reader Ethernet 100 m (328 feet) Cat5, Cat5E, and Cat6 Power Supply 12-24 VDC IN Using Belden 3105A, 22AWG twisted pair, shielded 100 Ohm cable, or equivalent. 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG), or equivalent. 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG), or equivalent. ALPHA 1299C, 22AWG, 9-conductor, stranded, overall shield. Fewer conductors needed if all control lines are not used. Refer to the power supply installation guide Introduction 1

* Minimum wire gauge depends on cable length and current requirements. 2 Max. Cable Length

Installation Before you install the ACM Embedded Controller, read through this entire document. Refer to the checklist at the end of this document and gather the required information before proceeding with these instructions. CAUTION The controllers and interface panels are sensitive to Electrostatic Discharges (ESD). Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precautions at all times. Preparing for the Installation 3 Mounting the Controller 3 Wiring the Controller 4 Accessing ACM Embedded ControllerApplication for the First Time 7 Changing the IP Address or Hostname 8 Configuring ACM Embedded Controller 9 Preparing for the Installation 1. On the ACM Embedded Controller, verify the battery jumper is installed in the ON position, P10 connector. 2. Verify the RS-485 termination jumper is in the Out position when there are no panels attached to the port. If there are downstream interface panels attached, place the termination jumper in the In position. The is shipped with jumpers in the Out positions. The P6 termination jumper controls RS-485 Port 1 P5 controls RS-485 Port 2 P13 controls RS-485 Port 3 P8 controls RS-495 Port 4 Mounting the Controller NOTE: Always mount the controllers and interface panels in a secure area. 1. Insert the provided mounting screws into the mounting holes at each corner of the controller. 2. Tighten the screws to secure the controller to the mounting location. 3. If you are installing more than one controller, position the device so that there is enough space for the wiring, airflow and cable runs. Do not remove the plastic base. NOTE: Use spacers if you are stacking ACM Embedded Controller devices without the cover or the LEDs on the device may break. Installation 3

Wiring the Controller NOTE: ACM Embedded Controller is a non-poe device. Do not connect J1 (Ethernet port) to a PoE capable port. This applies to both direct PoE Power Sourcing Equipment (Endspan PSE) and PoE injector (Midspan PSE) equipment. Not all PSE's correctly detect non-poe-capable devices. Tip: Keep the warning label at the bottom of the unit for future reference. CAUTION Connectors on the ACM Embedded Controller devices are positioned to be mirror images and are not interchangeable once the installation is complete. You cannot unplug a connector from one side and plug it into the corresponding connector on the other side. 1. Connect the controller to the network using a standard Ethernet cable. Connect one end of the Ethernet cable to the J1 (RJ-45) connector on the controller and the other end to one of the following: If you have a local area network, connect the other end to the network connection point (network port, hub, switch, or router). If you do not have a local network, connect the other end to a computer with a web browser installed. NOTE: Two LED lights exist on the RJ-45 connector. The green LED denotes Ethernet Activity and the yellow LED denotes speed. When the yellow LED is on, it indicates 100 Mbits per second. Another LED inboard is a Duplex LED, indicating duplex communications are available. 2. Connect power by providing appropriate DC input to the P7 connector. The appropriate DC input goes to the positive Power pin and ground to the negative Power pin. The P7 connector is wired as follows from left to right: Inputs P7 Input 5 Input 6 Input 7 Power Tamper + Tamper - AC Fail + AC Fail - Batt Fail + Batt fail - (-) Ground (+) 12-24 VDC 3. The controller supports these alarm inputs: tamper, AC fail, and battery fail. The alarm inputs are wired to the P7 connector as follows: Connect the Bat Fail and AC Fail inputs to the battery low/failure contact and the AC failure contacts on the power supply. Connect the Tamper input to a tamper switch on the enclosure. 4 Wiring the Controller

4. Connect the downstream HID VertX interface panels (either V100, V200, or V300) to the controller through a RS-485 bus. The controller has two RS-485 connectors and uses the 10-pin connector on P3 and P4. Each RS-485 bus can support a maximum of eight interface panels - any combination of HID VertX interface panels (either V100, V200, or V300) using one or two ports. Having two ports on each bus provides the option of splitting each RS-485 bus into two physical connections, and allow for a total of four physical connections for the two busses. The RS-485 busses can only be connected in a daisy chain topology and not a star topology. The RS-485 termination jumper should be in the Out position if there are no panels attached to the port. If there are downstream panels attached, the termination jumper should be in the In position. RS-485 Port # P3 RS-485 Port # P4 A A B B Port 1 Shield Port 3 Shield Not in use Not in use Not in use Not in use A A B B Port 2 Shield Port 4 Shield Not in use Not in use Not in use Not in use The RS-485 Ports 1 & 2 (P3) are a common bus and therefore cannot have panels with duplicate Interface Addresses assigned. The same is true of the RS-485, Ports 3 & 4 (P4). For example, two panels, both with Interface Address 0 (factory default), cannot be connected to Ports 1 and/or 2 (P3). On the HID VertX interface panels (either V100, V200, or V300), only wire the RS-485 on the P9 terminal block to the In position. This is especially important when the RS-485 communication is in a daisy chain configuration. If the RS-485 is wired In and Out, or the P9 terminal block is unplugged on the interface panel, RS-485 communications will be lost to subsequent downstream interface panels. 5. Make door connections to the V100 interface panels. Connect one door to each side of the V100 interface panel. Do not cross connections to the opposing side of the V100 interface panel or the door will not function correctly. 6. Make the output connections. All Output connections are used for general purpose controls. The following table shows where the various outputs are located. Pin numbers shown use the convention NO/C/NC. For example, Output 1, V200: P3 Pin 1 is NO (Normally Open), Pin 2 is C (Common), and Pin 3 is NC (Normally Closed). NOTE: Relays are dry contact rated for 2 Amps @ 30VDC. Wiring the Controller 5

Output number 1 2 3 4 V100 V200 V300 P3 Pins 1/2/3 Strike (lock) Relay 1 Relay 1 P3 Pins 4/5/6 Aux Relay 1 P6 Pins 6/5/4 Strike (lock) Relay 2 P6 Pins 3/2/1 Aux Relay 2 P3 Pins 2/3/4 P1 Pins 1/2/3 P6 Pins 3/2/1 P1 Pins 4/5/6 P1 Pins 7/8/9 P2 Pins 1/2/3 5 P2 Pins 4/5/6 6 P2 Pins 7/8/9 7 P4 Pins 9/8/7 8 P4 Pins 6/5/4 9 P4 Pins 3/2/1 10 P5 Pins 9/8/7 11 P5 Pins 6/5/4 12 P5 Pins 3/2/1 Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break voltage when de-energized due to magnetic field collapse. It is recommended you use of a snubber circuit across the controlling relay terminals to protect the controlling relay contacts. 7. Make the input connections. Input connections are analog inputs used for a combination of specific functions such as Request-to-Exit (REX), Door monitor, etc. They can also be used as general purpose monitoring. Connect one side of the switch or contact to the + (plus) lead and the other to the (minus) lead. The following table shows where the inputs are located. Pin numbers shown on the cover use the convention +/. The default REX input configuration is normally open (NO) unsupervised (no EOL resistors). Input number Aux Input 1 P14 + / - Aux Input 2 P11 + / - Input 5 P7 Tamper + / - Input 6 P7 AC Fail + / - Input 7 P7 Batt Fail + / - ACM Embedded Controller However, the default door switch (DS) configuration is Normally Closed (NC), unsupervised (no EOL resistors). 6 Wiring the Controller

The following inputs do not support supervision: Tamper (Input 5 on the V100/V200; Input 3 on the V300) AC Fail (Input 6 on the V100/V200; Input 4 on the V300) Batt Fail (Input 7 on the V100/V200; Input 5 on the V300) All other input points are defaulted for NO switches and are unsupervised (no EOL resistors). Any input can be configured as NO or NC. Inputs except Battery Fail, AC Fail and Tamper can be unsupervised or supervised. They can be configured for supervisory resistors of 2.2K Ohm. The setup of supervised inputs should be completed in the ACM Embedded Controller application. For more information, see the Access Control Manager Embedded Controller User Guide. Input number V100 V200 V300 1 P2 Pins 1/2 Door Monitor P1 Pins 1/2 P6 Pins 2/1 2 P2 Pins 3/4 REX input P1 Pins 3/4 P3 Pins 1/2 3 P5 Pins 4/3 Door Monitor P1 Pins 5/6 P7 Pins 8/7 Tamper 4 P5 Pins 2/1 Rex Input P1 Pins 7/8 P7 Pins 6/5 AC Fail 5 P7 Pins 8/7 Tamper P1 Pins 9/10 P7 Pins 4/3 Batt Fail 6 P7 Pins 6/5 AC Fail P2 Pins 1/2 7 P7 Pins 4/3 Batt Fail P2 Pins 3/4 8 P2 Pins 5/6 9 P4 Pins 10/9 10 P4 Pins 8/7 11 P4 Pins 6/5 12 P4 Pins 4/3 13 P4 Pins 2/1 14 P5 Pins 6/5 15 P5 Pins 4/3 16 P5 Pins 2/1 17 P7 Pins 8/7 Tamper 18 P7 Pins 6/5 AC Fail 19 P7 Pins 4/3 Batt Fail Accessing ACM Embedded ControllerApplication for the First Time After the controller has been installed, you need to access the ACM Embedded Controller application to complete the system configuration. You can access the application by using the controller hostname or virtual port. Accessing ACM Embedded ControllerApplication for the First Time 7

By Virtual Port By default, every controller can be accessed from this IP address: 169.254.242.121 To perform this procedure, you must use a Windows computer with a web browser and a network port. 1. Disconnect the computer from the network. 2. Connect the computer to the controller using an Ethernet cable. 3. On your computer, open command prompt. 4. Enter ipconfig/renew Wait for DHCP to timeout (approximately 60 seconds). The computer will acquire a 169.254.x.x address. 5. Open a web browser and enter this address: 169.254.242.121 The controller is now accessible through this virtual port. 6. Enter your login for the application. The default username and password is admin. By Host Name To access the ACM Embedded Controller application by this method, your DHCP server must support hostname access and only have one controller in the local area network (LAN). 1. Make sure the controller has a LAN connection. 2. Power the controller and wait 60 seconds for the controller to start up. 3. In a web browser, enter this address: https://acm-ec.<network domain> For example: https://acm-ec.example.lan The controller is now accessible through this URL. 4. Enter your login for the application. The default username and password is admin. Changing the IP Address or Hostname If you have more than one ACM Embedded Controller system in your network, you must set an IP address or unique hostname for each controller so that there are no communication conflicts. If you only have one controller in your system, you can skip this procedure. 1. Login to the ACM Embedded Controller application. 2. In the top-right Setup links area, click System. 3. On the Port screen, click eth0 in the Network Interfaces table. The Port Edit page is displayed. 4. Select one of the following options: DHCP Select this option to change the hostname. Enter a DNS setting if your DHCP server does not provide one. Static Select this option to use a specific IP address. Refer to the Configuration Checklist on page 14 for the required details. 8 By Virtual Port

5. Click to save your changes. Configuring ACM Embedded Controller After the ACM Embedded Controller system has been completely installed, you can customize the system to fit your needs. For more information about the available features, see the Access Control Manager Embedded Controller User Guide. Configuring ACM Embedded Controller 9

Troubleshooting If the following troubleshooting solutions do not resolve your issue, contact Avigilon Technical Support http://avigilon.com/support-and-downloads/. Replacing the Controller Battery NOTE: Do not replace the battery while the ACM Embedded Controller is powered. 1. Remove the cover on the controller. Figure 1: The controller battery. The prongs are highlighted on the lower end of the battery. 2. Lift the battery from the opposite side of the prongs then slide the battery up and away from the prongs. 3. With the + (positive) side facing upwards, insert the new battery under the prongs then press the opposite side into place. 4. Reinstall the cover. Restoring the Factory Default Network Settings If the ACM Embedded Controller displays potential errors in the network configuration, you may need to restore the controller to the factory default settings to resolve the issue. Troubleshooting 10

1. Remove the cover on the controller. Figure 2: The Debug port on the controller. 2. Reboot the controller by pressing the Reset button at the center of the controller. 3. While the power LED is green, place the supplied jumper over pins 3 and 5 of the Debug port. NOTE: The network reset opportunity occurs for 30 seconds while rebooting the controller. After 30 seconds, the power LED flashes green five times, indicating success. When an error occurs, the LED flashes red five times. In both instances, the LED turns off to show that the controller has shut down. 4. Remove the jumper, return it to pins 6 and 8 of the Debug port and reboot the controller. The controller resets in approximately 60 seconds. Once the reset is complete, the LED returns to green. After the 30 second window, the LED returns to normal Red state. The controller is fully functional during this time. CAUTION During the controller rebooting process, all network configuration information is overwritten and returned to the factory default settings. 5. Reinstall the cover. 6. Log in to the ACM Embedded Controller application and configure the controller network settings again. 11 Restoring the Factory Default Network Settings

Configuring Firewall Access If you need to access the Access Control Manager application from outside the local area network, you may need to configure your firewall to allow TCP data transfer on the following port numbers: HTTPS incoming 443 HTTP incoming and updates 80 If you are not familiar with configuring the network firewall, consult with your network or IT administrator. Power LED Behavior Outlined below is the Power LED behavior for the ACM Embedded Controller. After bootup The Power LED behavior (after boot up in a properly wired system) is as follows: NOTE: The inputs are dry inputs they do not have AC voltage or battery voltage applied. The power supply has outputs that trigger when it loses AC voltage and when battery voltage drops below a certain voltage. Light color Green Amber Red No light AC Fail terminal is closed Batt Fail terminal is closed Decscription State of the inputs: The power supply has both AC and reserve Battery voltage. AC Fail terminal is closed Batt Fail terminal is open State of the inputs: The power supply has AC power but does not have reserve battery voltage. There is no immediate need to worry but if there was a power outage the system will go offline. AC Fail terminal is open Batt Fail terminal is closed State of the inputs: The power supply does not have AC Power and is currently running on the reserve battery voltage. This is a very immediate concern. When the batteries run out, the system will go offline. AC Fail terminal is open Batt Fail terminal is open State of the inputs: The system is without power and the LED is off. During bootup The power LED during bootup for ACM Embedded Controller, adheres to the following sequence: Red (for about 40 seconds). Blinking Green (for about 6 seconds; it will blink 4 or 5 times). Configuring Firewall Access 12

Green (for about 30 seconds). Off (for about 15 seconds). Red/Amber/Green depending on the fail terminals. Comm LED Behavior During bootup, the Comm LED activates around 40 seconds into the bootup. The Comm LED behavior (after bootup in a properly wired system) for ACM Embedded Controller (1.6.2.0 or greater) should always be green indicating that the ACM Embedded Controller software is communicating with the on-board Controller firmware. If the Comm LED is red then contact Avigilon Technical Support at support@avigilon.com (or see http://avigilon.com/contact-us/ for other contact details). 13 Comm LED Behavior

Configuration Checklist Contact Name Email Phone Number IT contact Sales / PM Hardware Name Source Part Number Ethernet cable Computer with web browser Hub (optional) AC electrical outlet or surge protector (optional) Configuration Data Connection type Network ( DHCP or Static ) ACM Embedded Controller IP address Netmask Gateway Primary DNS server Secondary DNS server Broadcast address Domain name Virtual port enabled Yes No SSH Enabled Yes No Login password Configuration Checklist 14

Installation Worksheet Complete this worksheet to maintain a record of your system settings. Record if the input is wired: 1. Normally Open or Normally Closed 2. Unsupervised or Supervised (2.2K active or 4.4K active) 3. What type of device is attached Record if output is wired: 1. Normally Open or Normally Closed 2. What type of device is attached ACM Embedded Controller Information Customer Number: Contact: Installed Location: MAC Address: Hostname: IP Address: Tamper: AC Fail: BATT Fail: Input 1: Input 2: Relay 1: Relay 2: HID VertX V100 Series Information Interface Address: (0-31) Interface Type: (V100, V200, V300) Tamper: AC Fail: BATT Fail: V100 Door / Reader Interface Reader 1: Reader 2: Door Switch 1: REX 1: Door Switch 2: REX 2: Strike Relay 1: Aux Relay 1: Strike Relay 2: Aux Relay 2: V200 Input Monitor Interface Input 1: Input 2: Input 3: Input 4: Input 5: Input 6: Input 7: Input 8: Input 9: Input 10: Input 11: Input 12: Input 13: Input 14: Input 15: Input 16: Relay 1: Relay 2: V300 Output Control Interface NOTE: Functionality may be limited depending on the version of the ACM Embedded Controller application. Relay 1: Relay 2: Relay 3: Relay 4: Relay 5: Relay 6: Relay 7: Relay 8: Relay 9: Relay 10: Relay 11: Relay 12: Input 1: Input 2: Installation Worksheet 15