S-series Horizontal Carriers

Similar documents
S-series Horizontal Carriers

DeltaV SD Plus Controller

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

S-series DeviceNet Interface Card

S-series Sequence of Events Card

S-series Profibus DP Interface Card

S-series Serial Interface

S-series H1 I/O Card with Integrated Power

DeltaV M-series I/O Subsystem Horizontal Carriers

M-series I/O Subsystem Horizontal Carriers

DeltaV VerticalPlus I/O Subsystem Carriers

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

S-series Electronic Marshalling for Migrations

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

M-series DC to DC Power Supply

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

M-series MQ Controller

S-series Foundation Fieldbus I/O

M-series Profibus DP Series 2 Plus Interface Card

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

M-series MX Controller

S-series Mass Connection Solutions

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

DeltaV Electronic Marshalling for Migrations

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

S-series DeviceNet Interface Card

S-series Sequence of Events Card

M-series DeltaV Controller Interface for PROVOX I/O

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

M-series Intrinsically Safe I/O

DeltaV Bulk Power Supplies

M-series Traditional I/O

S-series Electronic Marshalling

S-series Virtual I/O Module 2

M-series DeltaV Controller Interface for RS3 I/O

DeltaV SIS Conditioning Components

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

DeltaV Bulk Power Supplies

S-Series DeltaV Controller Interface for PROVOX I/O

M-series Virtual I/O Module 2

M-series Virtual I/O Module 2

M-series MQ Controller

DeltaV SIS TMConditioning Components

M-series Foundation Fieldbus I/O

S-series IS Electronic Marshalling

S-series Virtual I/O Module 2

M-series Profibus DP Series 2 Plus Interface Card

DeltaV Ethernet I/O Card

Plant Messenger. Introduction. DeltaV Product Data Sheet. Delivers the information you want when and where you want it

DeltaV Control Network Hardware

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

DeltaV S-series Traditional I/O

Free Standing DeltaV Double Door Cabinet

S-series Electronic Marshalling

S-series Ethernet I/O Card

S-series Electronic Marshalling

DeltaV Wireless I/O Card

DeltaV Virtual IO Module Network Gateway

CTO CSLS CHARM Cabinets

DeltaV M-series Traditional I/O

Free Standing DeltaV Single Door Cabinet

M-series Serial Interface Series 2

Batch Historian. Batch Historian. Introduction. DeltaV Product Data Sheet. Configuration-free, batch-based data collection

DeltaV M-series Traditional I/O

S-series IS Electronic Marshalling

DeltaV M-series Traditional I/O

DeltaV Electronic Marshalling

S-series Serial Interface

DeltaV Controller Firewall

M-series Serial Interface Series 2

Emerson & Westinghouse

DeltaV IS Electronic Marshalling

History View Software Suite

FLEX Ex Spring Clamp Terminal Base

DeltaV Four-Monitor Workstation

DeltaV Safety Instrumented System (SIS) with IS Electronic Marshalling

DeltaV Simulate. DeltaV Simulate. Introduction. DeltaV Product Data Sheet. Allows DeltaV configuration on a single PC or in a multi-node system.

Installation Instructions

Simple but elegant look and ease of installation make it ideal for various industrial applications.

About the FLEX I/O and FLEX Ex I/O Systems

Operator Station Software Suite

DeltaV History Analysis

Backplane. Allen-Bradley. System integration. Backplane

DeltaV Connect Solution for Bailey Systems

CTO Server and Network Cabinets

Backplane. System integration. Backplane

Backplane. System integration. Backplane

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Faster module execution

Installation Instructions

DeltaV Controller Firewall

QuickPanel View & QuickPanel Control

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

Product Data Sheet DeltaV 10.3 with AMS Device Manager Simplified Chinese Jan 2010 Page 1

Digital ac/dc (24V) Input Module

1756 ControlLogix Chassis Specifications

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Transcription:

January 2013 Page 1 The DeltaV modular I/O subsystem is easy to install and maintain Modular design allows flexible installation Allows you to expand online Integrated power distribution Snap in assembly Introduction The DeltaV S-series hardware takes the proven DeltaV hardware to a new level of robustness and ease of use. Assembly is faster and power distribution is easier, with fewer connections using the integrated field power distribution and increased capacity of I/O bus power. The modular design allows you to purchase only what you need with the ability to expand online later simply by adding The power/controller and I/O carriers are modular. Purchase only what you need but be assured that as your system grows you can add plug-and-play carriers Easy! www.deltav.com

January 2013 Page 2 Benefits Modular design allows flexible installation. A T- type DIN rail is all you need to mount the power/controller carrier into place. Snap the I/O interface carriers to the rail and slide to connect it to the carrier on the left. Add as many carriers as needed, or use extender cables to move to a new rail. The DeltaV system s modular design approach allows you to add I/O carriers as you need them. Allows you to expand online. Additional 8-wide carriers may be added online as desired. Bus extenders provide dual cabling for robustness, allowing up to 8 I/O carriers for a total of 64 simplex cards or 32 redundant cards. Integrated power distribution. Controller and I/O interface power distribution is integrated into the carriers to reduce and simplify power and grounding. I/O Carriers have an integrated shield ground bar to isolate and drain field noise away from system power. They also provide an integrated redundant 24 VDC bussed field power distribution to reduce installation wiring and provide fused, isolated power to each I/O interface, using Power Buss Plugs. Alternatively, the I/O carriers can be ordered with Power Terminal Plugs to bring dedicated power to each card, which can be either 24 VDC or 120/230 VAC. Power Buss Plugs and Power Terminal Plugs can be mixed on one I/O Carrier. A single Power Terminal Plug will come with any 120 VAC DI or 120/230 VAC DO card! Snap In Assembly. All components snap into place without the use of special tools. The design supports and easy on design to speed up installation and reduce maintenance turnaround. Carriers snap onto T-DIN Rails. All interfaces and system power supplies snap into place, eliminating retention screws. Product Description The S-series IO subsystem has been redesigned with a focus on fast assembly and simplified power connections. The system uses only 24 VDC bulk power supplies. All power is connected to system carriers. Bus connectors have been upgraded to support additional 12 VDC power to the IO cards, allowing additional power carriers to be inserted anywhere along the bus. Carriers mount to standard t-type DIN rail with latches that require no tools for quick installation. The latches can be released using a blade screw driver. Simply snap the carrier to the rail and slide adjacent carriers together to engage the bus connector. The I/O carrier supports 8 IO modules. Each card can be connected to an internal 24 VDC bus using the Power Buss Plugs, or it can be individually powered by using the Power Terminal Plugs. The internal 24 VDC bus is divided into primary and secondary power, with primary power distributed to odd numbered slots and redundant power distributed to even numbered slots using the Power Buss Plugs. The DeltaV horizontal-mount carriers provide plug-and-play ease for your I/O subsystems

January 2013 Page 3 Hardware Specifications. 24 VDC power Input 8 amps Specifications for S-series Power/Controller carriers Power/controller carrier 2 Power supplies or 1 power supply with 1 Controller Specifications for S-series Horizontal I/O carriers Backplane Current Power Terminal Plug Power Buss Plug (fused) Primary/Secondary 24 VDC Bussed power distribution IO carrier capacity 15 Amps 12 Amps 5 Amps 12 Amps per bus (Max 3 A per card) 8 IO modules Environmental Specifications. Operating Temperature Storage Temperature Relative humidity Airborne contaminants -40 to 70 C (-40 to 158 F) -40 to 85 C (-40 to 185 F) 5 to 95%, non-condensing ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating Protection rating IP 20 Shock Vibration 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

January 2013 Page 4 System Compatibility S-series carriers support S-series controllers, power supplies and I/O cards. M-series I/O cards are not supported on S-series controllers. DeltaV SIS logic solvers can be installed under an S- series controller using SIS horizontal and vertical carriers. The DeltaV SIS S-series adapter enables M-series horizontal carriers to be connected to S-series controllers. This enables logic solvers to be installed on the same nodes with S-series controllers and I/O. S-series hardware is designed around 24 VDC bulk power, for both controller and I/O interfaces. 12 VDC bulk are not supported on the 2-wide Power/Controller carriers. Certifications The following certifications are available on S-series horizontal carriers. CE: - EMC- EN 61326-1:2006 - LVD- EN 61010-1:2001 CSA: - CLASS 2252 05 - PROCESS CONTROL EQUIPMENT: CAN/CSA-C22.2 No. O-M91 General Requirements- Canadian Electrical Code, Part II CAN/CSA-C22.2 No. 61010-1-04 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements Complies with NAMUR NE21 per DeltaV Digital Automation System NAMUR NE21 Installation Instructions 12P2822. The following certifications have been submitted for Hazardous Locations and for Marine applications. Please verify with the appropriate certifying agency for a specific list of approved components CENELEC Zone 2 ATEX/IEC EX EN 60079-15:2005 Certifying agency: Nemko Certificate Number: TBD Refer to document TBD "DeltaV Scalable Process System Zone 2 Installation Instructions" FM Approval Class 1 Division 2 Hazardous Locations Certifying agency: FM Approvals Certificate Number: TBD Refer to document TBD "DeltaV Scalable Process System Class 1 Division 2 installation Instructions Marine Certifications: IACS E10:2006 Rev.5 Control, protection & Safety - ABS Certificate of Design Assessment - Bureau Veritas Certificate - DNV Marine Certificate - Lloyds Register GOST Hazardous Area certification Zone 2 (Russian) Other country specific certifications may also be available. Verify with your local Emerson sales office to confirm any certification requirements not listed here..

January 2013 Page 5 Ordering Information Description View Model Number 2-Wide Power/Controller Carrier SE3051C0 2-Wide Power/Controller Carrier with Dual Extender Cables 1.1m (43 in) SE3051C2 2-Wide Power/Controller Carrier with Single Extender Cable 1.1m (43 in) SE3051C3 8-Wide I/O Interface Carrier with 8 Power Buss Plugs and a Carrier Shield Bar 8-Wide I/O Interface Carrier with 8 Power Buss Plugs, a Carrier Shield Bar, and a Single Carrier Extender Cable 1.1m (43 in) SE4050E0C0 SE4050E1C0 8-Wide I/O Interface Carrier with 8 Power Buss Plugs, a Carrier Shield Bar, and Dual Carrier Extender Cables 1.1m (43 in) SE4050E2C0 8-Wide I/O Interface Carrier with 8 Power Terminal Plugs and a Carrier Shield Bar 8-Wide I/O Interface Carrier with 8 Power Terminal Plugs, a Carrier Shield Bar and a Single Carrier Extender Cable 1.1m (43 in) SE4059E0C0 SE4059E1C0 8-Wide I/O Interface Carrier with 8 Power Terminal Plugs, a Carrier Shield Bar and Dual Carrier Extender Cables 1.1m (43 in) SE4059E2C0 DeltaV SIS S-series Adapter SE4058

January 2013 Page 6 Description View Model Number Carrier Blank Cap (for 8-Wide I/O Interface Carrier only) SE6101 Any horizontal DIN rail monted combination of carriers and extenders requires two DIN Rail stops to prevent carriers from disconnecting. Order VE4054DRS, which is a box of 5. Spare part ordering Information Spare Parts Description Power Terminal Plug for 2-Wide and 8-Wide Carriers Power Buss Plug for 8-Wide Carriers Left Extender 1-Wide Right Extender 1-Wide Single Carrier Extender Cable 1.1m (43in) Single Carrier Extender Cable 0.4m (17in) Single Carrier Extender Cable 0.8m (31in) Single Carrier Extender Cable 1.5m (58in) Single Carrier Extender Cable 1.9m (77in) Model Number KJ4005X1-BF1 KJ4005X1-BG1 KJ4005X1-BB1 KJ4005X1-BC1 KJ4003X1-BH1 KJ4003X1-BH2 KJ4003X1-BH3 KJ4003X1-BH4 KJ4003X1-BH5 To locate a sales office near you, visit our website at: www.emersonprocess.com/deltav Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774 For large power, water, and wastewater applications contact Power and Water Solutions at: www.emersonprocess-powerwater.com Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East, Africa: 48.22.630.2443 North America, Latin America: +1 412.963.4000 Emerson Process Management 2013. All rights reserved. For Emerson Process Management trademarks and service marks, go to: http://www.emersonprocess.com/home/news/resources/marks.pdf. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice. www.deltav.com