Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Similar documents
Human Machine Interfaces

GT series becoming more visible and compact GT30C. 5.7 inch dots. STN color LCD 16 colors. CFL backlight Matrix switch RS232C

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

RS485 MODBUS Module 6RO

RS485 MODBUS Module 8AO

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

GT series becoming more visible and compact

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Product RS stock no. Mitsubishi no. Description and features Display FX-40DU-E LCD display and function keys directly connected into FX PLC

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

T1K MODBUS Base Controller Specifications

1.5 axis motion controller

RS485 MODBUS Module 8I8O

NF760 Batch Controller

RS232C/RS485 Data can be easily monitored by LAN

RS485 MODBUS Module 16I-M

RS485 MODBUS Module 8I8RO

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Programmable Relay ZEN V2 Units

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

TABLE OF CONTENTS. Communication Functions

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

FEC-240G. Rev. Date

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

RS 485 Mini Modbus 1AO

FIOD 0808 Manual. The FIOD series products add digital capability to your PLC / SCADA.

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Appendix 3 Using NS-AL002 Converters

FP-e Control Unit New Born! Advanced PLC! Timer, Counter, Hour meter, Temperature Controller and PLC in a Unit

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

MODEL: R1M-GH. PC Recorders R1M Series

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring:

Model Number Structure

MODEL: GR8-EM. Communication Adaptor GR8 Series

MRUC-20 Modul-R CAN Bus Network

RS485 IO Slim Module MOD-ETH

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

2. Actuator B: Ball type P: Pin type F: Flat type

Communication Controller CC-Link/CPL Converter CMC10A

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Paperless Recorder VGR-B100. Series

User Manual A08. User Manual

Product Specification for SAB-S-MODBUS

Phone: Fax: Web:

High Voltage DC Meter

FP-1000PW. Thermal Printer User s Manual. Fujitsu Isotec Limited. KA02066-Y Standard Model Built-in Power Supply Model FP-1000

DIGITAL INDICATING CONTROLLER

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom

NetBiter I/O Extender User Manual

MIC-2 MKII, Multi-instrument DATA SHEET

HIGH-VOLTAGE DC METER

General Specifications

Table of Contents... 1 Operation Mode... 2 Connecting System Menu... 14

PWS500S Installation Guide

KTA-250 Anemometer Alarm Card

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms.

Energy Management Modular Energy meters Type EM2-96

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

IT and Instrumentation for industry. Features. Introduction. Applications

SYSMAC Remote Transistor Module

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MU110-6U. Analog output module 6 channel. User guide

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

i 2 Index Communications Ports, 2 6 Conventions Used, 1 3 exclamation mark, 1 3 notepad, 1 3

FX-485PC-IF RS485 Interface Unit Hardware Manual

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

HMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Product Description. Contents. Fusion Series. New Information December 2003

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

PWS1711/1760 Installation Guide

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

APP 700 Technical Specification

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Expansion Module HZS 541-1S

NF770 Temperature Compensation Liquid Flow Computer

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

TWDLMDA40DUK extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Industrial 2-port RS422/485 Modbus Gateway

ASTAT XB/XBm Remote Operator

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

MDA-8000 DIO User Manual

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

PCI Express 4-Port Industrial Serial I/O Cards

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

Transcription:

Message Runner KP3H Text Small messages on your machine This small and compact display is extremely well-suited for indicating a variety of short messages. Compact DIN 36 x 7 profile The compact DIN 36 x 7 profile allows the unit to be easily installed in control boxes where space did not allow other units to be installed. Green and orange character display The text can be displayed in either green or orange to reflect equipment status at a glance. A blinking display is also available at the user`s discretion for defining messages appearance! Maintenance free Since LEDs are used for the LCD backlight, troublesome lamp replacement is not necessary. A backup battery is not required as the message data is stored in the Message Runner`s flash memory. Easy-to-read message display The 8-character display allows scrolling of up to 3 characters in length. Up to 6 messages can be saved and easily displayed.

Message Runner KP3C and KP3R Text In addition to the KP3H s features the KP3C and KP3R Message Runners enable message switching and data rewriting by serial communication (KP3C: RS33C, KP3R: RS85) When creating messages, the character * is definied as data. Example: The message *****pcs has a five-column data area. Refer to the figure below: 3 5 is the value in the PLCs data register. Three data areas can be included in one message. One message may include 3 characters ( * ) maximum for lateral display (6 characters vertical). Message stand-by function Is selectable for each message, i. e. if a new signal arrives while a message is being displayed, the new message is displayed after the current message finishes. End message signal can be output You can select whether or not to output a signal to an external device for each message. An internal relay for the PLC can be specified and a flag turned on. (This is called the scroll finished flag). To reset the flag, use the PLC programming software. Vertical display The KP3C and KP3R Series can be mounted in lateral or vertical direction. The length of displayable messages is 3 characters for lateral display and 6 characters for vertical display. 08/005

Message Runner KP3C and KP3R Text Features available for KP3C Message Runners only Five data formats selectable: 6 bits with sign 6 bits without sign 3 bits with sign 3 bits without sign ASCII (0h to 7Eh) Four communication protocols selectable Panasonic Electric Works FP Series Multi-purpose serial (Message Runner dedicated protocol) Computer link for Mitsubishi MELSEC-FX Series Host link for Omron SYMAC-C Series (exclusive) Features available for KP3R Message Runners only Either lit or blinking messages data format: ASCII 0 (hex) to 7E (hex), except of 3F (hex) on Multi-purpose protocol Two communication protocols selectable Blinking Multi-purpose serial (Message Runner dedicated protocol) MODBUS (RTU) Communication distance of up to 00m. Max. 3 units can be connected. 3

Message Runner Dimensions and Wiring Dimensions and part names 65 5 8 7 7 68 in mm 3 +0.7 in mm 36 5 33.0 +0.6.5 Applicable thickness:.0 to.5 mm Rubber cover Installation bracket AKP380 Panel cover Panel cutout dimensions Terminal wiring KP3H *Be sure to turn off the power of the Message Runner unit and computer before connecting or disconnecting the connector and transmission cable. Rear External switch SW5 SW3 SW Load + 0+ NC 6 0 R 3 8 C + SW7 C : Common R : Reset The AKP3835 (m) and AKP3837 (3m) connector with lead wires is available (optional). - : Power supply inputs 3 6 8 : Call up terminals External switch SW8 SW6 SW SW NC : not connected When using a non-contact (transistor) input, connect as follows: 0+ 0 : Output, max. 0.A, 30VDC As a guideline, the collector voltage of the transistor should be 50V or higher, and the leakage current should be less than ma. Functions for dip switch Terminal wiring KP3C Power supply and COM.port terminal block Ground Sending data (output) Receiving data (input) Ground for signal Power supply ( to V DC) SD RD SG COM.port (RS3C) Other device OFF 3 5 6 Number Functions OFF Baud rate 9, 00 bps 9, 600 bps 7 bits Data length 8 bits No 3 Parity Yes Even Parity type Odd Data transmitting Operation 5 Mode selection Modular Terminal block 6 Connector selection Data transmission mode: Mode for sending created message and settings from the PC to the Message Runner. Operation mode: Mode for transferring data with a PLC, etc., to change messages and data. Connector selection: Select the connector for use with the data transmission mode. Cross cable is used to connect another device to the COM.port. Functions for dip switch Terminal wiring KP3R Power supply and COM.port terminal block. 08/005

Message Runner Specifications Product types Order-No: Body (with face characters) Message Runner KP3H (-VDC) AKP3003 Body (without face characters) Message Runner KP3H (-VDC) AKP3007 Body (with face characters) Message Runner KP3C (-VDC) AKP33 Body (without face characters) Message Runner KP3C (-VDC) AKP37 Body (with face characters) Message Runner KP3R (-VDC) AKP333 Body (without face characters) Message Runner KP3R (-VDC) AKP337 Programming unit m message transfer cable + message creation software AKP3803M Transfer cable m message transfer cable AKP38 Message creation software CD available for KP3H, KP3C and KP3R AKP3863M Rubber packing Use when water resistance is required for the panel AKP380 Panel cover (black, with face characters) AKP380 A panel cover (ash grey) for the body is provided as standard Panel cover (black, without face characters) AKP3805 Connector with lead wires for KP3H Length: m (one line) AKP3835 Length: 3m (one line) AKP3837 General Rated power supply -VDC Operating voltage range 0.8 to 6.VDC Power consumption Approx..W (KP3H and KP3C) and.5w (KP3R) Ambient temperature 0 C to 0 C Ambient humidity 0 to 85% RH (non-condensing) Storage temperature -0 C to 60 C Storage humidity 0 to 85% RH (non-condensing) Resolution Backlighting Character display Message length Character types Character control Negative-type dot matrix LCD 6 x 6 dots Green / Orange LED (can be set for each message) 8 characters x line 3 characters (max.) Internal PC character set depending on the internal character type, some characters cannot be displayed (circled characters, Roman numerals and so on) Scrolling display possible (slow, medium or fast), blinking display (0.s / 0.s OFF) Memory Message storage Internal memory 6 messages F-ROM (battery backup not required) Communication specifications (KP3C and KP3H) Note: The shielded cables are recommended where electrical noises might occur. Item KP3C Specification KP3H Specification Communication standard Confirming to RS3C Confirming to RS85 Communication method Half duplex transmission Transmission distance Max. 5m Max. 00m Transmission speed 9,00 bps / 9,600 bps (selectable using DIP switch) Character bit 8 bits / 7 bits (selectable using DIP switch) Stop bit bit fixed Parity Odd/Even/None (selectable using DIP switch) Protocol MEWTOCOL, Multi-purpose protocol (exclusive for Message Runner), Mitsubishi MELSEC-FX Series, Omron SYMAC-C Series Multi-purpose protocol (exclusive for Message Runner), MODBUS (RTU) 5