Datasheet - AZM 200SK-T-1P2PW

Similar documents
Datasheet - AZM300Z-ST-1P2P-A

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet AZM 161 Z ST1 AS RA

Datasheet - RSS 36-D-R-ST

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Datasheet - CSS 11-30S-D-M-ST

Datasheet - SRB 301LC/B-24V

Datasheet SRB301ST 24V (V.2)

Datasheet - SRB 402EM-24V

Datasheet - SLB 200-C04-1R

Datasheet - AZ 16-03ZVRK

Datasheet - BNS ZG

Datasheet - BNS ZG-ST

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16-02ZVRK-ST

Datasheet - AZ 15 ZVK

Datasheet - AZ 16-02ZVK

Datasheet - AZ 15 ZVRK

Datasheet - ZR Z

Datasheet - AZ 16ZVRK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVRK

Datasheet - ZR Z

Datasheet - ZS Z

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

Non-Contact Safety System CES-AZ

Operating instructions Solenoid interlock MZM About this document. Content

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Safe switching and monitoring Non-Contact Safety Sensors

XPSMCMDI Input expansion module with screw term

XPSMCMDO Digital output pairs expansion modules with screw term

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

E-STOP relays, safety gate monitors

PNOZ s1. Safety relays. Operating Manual EN-07

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XPSMCMMX inputs 2 output pairs expansion module with screw term

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Safety switches with separate actuator

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

ZB5FG09 flush mounted selector switch head key pos stay put

Operating instructions Solenoid interlock MZM 100 MZM 100 B. 1. About this document. Content

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

Safety switches with manual mechanical delay and separate actuator

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

Safety switches for hinged doors

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

RM35LM33MW liquid level control relay RM35-L V AC/DC

Online data sheet. i10-m0233 Lock i10 Lock SAFETY LOCKING DEVICES

Safety switches with manual mechanical delay and separate actuator

E-STOP relays, safety gate monitors

TM3SAF. Main. Device short name

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

Safe timer relay/contact expansion modules

XCMD21F0L2 limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m

E-STOP relay, safety gate monitor

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Two-hand control unit

XACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

SR A series coded magnetic safety sensor

Safety switches with separate actuator

Zelio Control-modular measurement and control relays 1

Two-hand control unit

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety Switches CES-AR/CET-AR

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

SR B series coded magnetic safety sensors

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Operating instructions Safety-monitoring module SRB301STV.2 /CCV.2 /PCV.2 SRB301STV.3 /CCV.3 /PCV About this document.

Transcription:

08.04.2015-16:16:26h Datasheet - AZM 200SK-T-1P2PW Solenoid interlock / AZM 200 thermoplastic enclosure Guard locking monitored Electronic contact-free, coded system Max. length of the sensor chain 200 m Self-monitoring series-wiring of 31 sensors 3 LEDs to show operating conditions Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally Intelligent diagnosis Manual release (Minor differences between the printed image and the original product may exist!) Ordering details Product type description AZM 200SK-T-1P2PW Article number 101195442 EAN code 4030661360799 ecl@ss 27-27-26-03 Approval Approval TÜV USA/CAN Classification interlocking function: Standards EN ISO 13849-1, IEC 61508, IEC 60947-5-3 PL bis e Control category bis 4 PFH 4.0 x 10-9/h PFD value 1.0 x 10 4 SIL bis 3 Mission time 20 Years Classification PDF-M

Global Properties Product name AZM 200 Standards EN 60947-5-1, IEC 61508, EN ISO 13849-1, EN ISO 13849-1 Compliance with the Directives (Y/N) Suitable for safety functions (Y/N) Protection rating II Series-wiring up to 31 components Length of the sensor chain max. 200 m Active principle inductive Duty cycle 100 % Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic Housing coating ne Weight 590 g Guard locking monitored (Y/N) Actuator monitored (Y/N) Idle assignable pushbutton and LED (Y/N) Reaction time 60 ms Duration of risk > 120 ms Time to readiness 4000 ms Recommended actuator AZ/AZM 200-B1 Mechanical data Design of electrical connection Screw connection Cable section - Min. Cable section 0,25 mm² - Max. Cable section 1.5 mm² AWG-Number 23-15 Mechanical life 1.000.000 operations notice All indications about the cable section are including the conductor ferrules. restistance to shock 30 g / 11 ms Resistance to vibration 10... 55 Hz, Amplitude 1 mm Emergency unlocking device (Y/N) Manual release (Y/N) Emergency release (Y/N) Latching force 30 N Clamping force Fmax 2000 N Max. Actuating speed 0,2 m/s Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +60 C Storage and transport temperature - Min. Storage and transport temperature 25 C - Max. Storage and transport temperature +85 C Relative humidity 30%... 95% - non-condensing Protection class IP67 to IEC/EN 60529 Air clearances and creepage distances To IEC/EN 60664-1 - Rated impulse withstand voltage Uimp 0,8 kv

- Overvoltage category III - Degree of pollution 3 Electrical data Number of auxiliary contacts Number of safety contacts Cross circuit/short circuit recognition possible (Y/N) Power to unlock Power to lock 0 piece 2 piece Supply voltage UB - Min. supply voltage 20.4 VDC - Max. supply voltage 26.4 VDC Switch frequency 1 Hz Rated insulation voltage Ui 32 VDC 1.2 A Utilisation category DC-12, DC-13 -load current I0 0,6 A Device insulation 4 A if used in accordance with UL 508 Electrical data - Safety inputs Safety inputs Rated operating voltage Ue X1 and X2-3 V... 5 V (Low) 15 V... 30 V (High) > 2 ma / 24 V Electrical data - Safety outputs Safety outputs Fuse rating Rated operating voltage Residual current Ir Utilisation category Y1 and Y2 short-circuit proof, p-type 0 V... 4 V under Supply voltage UB 0,5 ma 0,25 A DC-12, DC-13 Electrical data - Diagnostic output Serial diagnostics (Y/N) Fuse rating Utilisation category Wiring capacitance for serial diagnostics - diagnostic signals Operating principle of the diagnostic output notice p-type, short-circuit proof 0,05 A DC-12, DC-13 guard door closed and interlocking device locked The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. The diagnostic output is not a safety-relevant output! Electrical data - Solenoid control IN Rated operating voltage Ue - 3 V... 5 V (Low) 15 V... 30 V (High) typically 10 ma / 24 V, dynamically 20 ma

LED switching conditions display LED switching conditions display (Y/N) LED switching conditions display - Supply voltage UB green LED - switching condition yellow LED - Error functional defect red LED ATEX Explosion protection categories for gases Explosion protected category for dusts ne ne Dimensions Dimensions of the sensor - Width of sensor 40 mm - Height of sensor 220 mm - Length of sensor 50 mm notice As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. Included in delivery Included in delivery AZM 200 Triangular key Actuators must be ordered separately. Indication legend see drawing: Wiring example With the represented power-to-unlock principle, the solenoid is energised to enable the opening. With the alternative power-to-lock principle (not represented), the solenoid must be energised to keep the device in closed condition. Ordering code AZM 200(1)-T-(2)(3)(4) (1) without B (2) SK CC ST1 ST2 (3) 1P2P 1P2PW SD2P Guard locking monitored Actuator monitored Screw connection Spring pulley connection connector M23 x 1, (8+1-pole) connector M12 x 1, 8-pole 1 Diagnostic output and 2 Safety outputs, p-type gleich - 1P2P, combined diagnostic signal: guard door closed and interlocking device locked serial diagnostic output and 2 Safety outputs, p-type

(4) without A Power to unlock Power to lock Documents Operating instructions and Declaration of conformity (pl) 363 kb, 11.02.2015 Code: mrl_azm200t_pl Operating instructions and Declaration of conformity (jp) 416 kb, 20.02.2013 Code: mrl_azm200t_jp Operating instructions and Declaration of conformity (es) 345 kb, 13.02.2015 Code: mrl_azm200t_es Operating instructions and Declaration of conformity (en) 339 kb, 28.11.2014 Code: mrl_azm200t_en Operating instructions and Declaration of conformity (pt) 346 kb, 26.06.2012 Code: mrl_azm200t_pt Operating instructions and Declaration of conformity (fr) 346 kb, 13.02.2015 Code: mrl_azm200t_fr Operating instructions and Declaration of conformity (it) 342 kb, 13.02.2015 Code: mrl_azm200t_it Operating instructions and Declaration of conformity (de) 344 kb, 28.11.2014 Code: mrl_azm200t_de Operating instructions and Declaration of conformity (nl) 292 kb, 03.06.2013 Code: mrl_azm200t_nl Operating instructions and Declaration of conformity (da) 312 kb, 22.08.2013 Code: mrl_azm200t_da Operating instructions and Declaration of conformity (sv) 340 kb, 19.03.2012 Code: mrl_azm200t_sv Wiring example (99) 21 kb, 12.01.2009 Code: kazm2l26 Diagnosis tables (en) 136 kb, 12.01.2009 Code: b_tabp02 Diagnosis tables (de) 135 kb, 12.01.2009 Code: b_tabp01 TÜV certification (de, en) 599 kb, 25.03.2015 Code: z_azmp04 Gost certification (ru) 1 MB, 21.06.2007 Code: q_azmp01

Images Dimensional drawing (miscellaneous) Wiring example System components Actuator 101183465 - AZ/AZM 200-B1-LT Actuators with return spring Actuator for sliding guards Tolerates up to max. 5 mm overtravel 101183466 - AZ/AZM 200-B1-LTP0 Actuators with return spring Actuator for sliding guards Tolerates up to max. 5 mm overtravel 101183469 - AZ/AZM 200-B1-RT Actuators with return spring Actuator for sliding guards Tolerates up to max. 5 mm overtravel 101183470 - AZ/AZM 200-B1-RTP0 Actuators with return spring Actuator for sliding guards

Tolerates up to max. 5 mm overtravel 101178681 - AZ/AZM 200-B30-LTAG1 101178668 - AZ/AZM 200-B30-LTAG1P1 101186150 - AZ/AZM 200-B30-LTAG1P20 101192102 - AZ/AZM 200-B30-LTAG1P25 101181137 - AZ/AZM 200-B30-LTAG2 101181141 - AZ/AZM 200-B30-LTAG2P1

101189020 - AZ/AZM 200-B30-LTAG2P20 101192106 - AZ/AZM 200-B30-LTAG2P25 101178680 - AZ/AZM 200-B30-RTAG1 101178738 - AZ/AZM 200-B30-RTAG1P1 101186144 - AZ/AZM 200-B30-RTAG1P20

101192103 - AZ/AZM 200-B30-RTAG1P25 101181139 - AZ/AZM 200-B30-RTAG2 101181143 - AZ/AZM 200-B30-RTAG2P1 101191659 - AZ/AZM 200-B30-RTAG2P20 101192104 - AZ/AZM 200-B30-RTAG2P25 K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 08.04.2015-16:16:27h Kasbase 3.1.2.F.64I