ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

Similar documents
CBAM270 XETK ECU Adapter and Power Supply Cable, pre-assembled into PG9 screwing, shield on ECU-Housing, Lemo 1B PHE - JST PHR (10fc-5fc) / Lemo 0B

SAFETY ADVICE (English)

AC Voltage Distributor ES Instruction Manual

INCA V7.2 INCA Instrument Integration Development Kit V1.2 Quick Start Guide

PB4350DAC1 - D/A Module User s Guide

B63/ NS MS. EtherNet/IP LINK

ETAS CONGRA V1.3.0 Installation Guide

PB1651ADC1 A/D Module User s Guide

ETAS SCODE-ANALYZER Getting Started

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

UP-1-1 Channel Dimmer. User manual. dimmer pack

ES922.1 Version 1.1.0

UP-1-1 Channel Dimmer dimmer pack. user manual

Serial PROFIBUS Interface

LABCAR-FWP V Release Notes LABCAR-FWP V Release Notes. Page 1 of 5

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

Installation manual plugs and connectors with screw connection (16/32 A)

LABCAR-FWP V Release Notes LABCAR-FWP V Release Notes. Page 1 of 6

TPC25 active crossover. user manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

DS-2 RF DMX dimmer. user manual

Technical Manual Room temperature controller

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Harley Benton Power-Attenuator power attenuator. user manual

LED Pixel Rail Drive 640 controller. user manual

DMX Splitter 4 MKIII 19" DMX splitter. user manual

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

HSP-SP V Release Notes HSP-SP V Release Notes. Page 1 of 7

TA18 active subwoofer. user manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Foot switch. Installation, operation and maintenance manual

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Operating Instructions

MDM 011-Z1 Regen Resistor

IPCB42501 / IPCB42551

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

DPX-620III 6-Ch. dimmer pack. user manual

ES585.1 K-Line Interface Compact. User's Guide

SolConeX extra-low voltage flange socket

Type Quickstart

TVAC25100 TVAC25110 User manual

D1210H dimmer pack. user manual

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

BI20 OPERATING MANUAL LOCATING DEVICE TRT-BA-BI20-TC-002-EN

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Pixel Panel 144 RGB effect panel. user manual

VR 71. Installation instructions. Installation instructions. For the competent person GB, IE. Publisher/manufacturer Vaillant GmbH

Expansion module EM-BAC-MOD-01. Installation manual

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

D-SEED effects pedal. user manual

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

CPCI-PS24 24V-Power Supply

NX1 Pocket Toner Users Guide

Type ME43. Quickstart

C9900-P223 and C9900-P224

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

User Manual. Printer P-52RUE

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Network Camera. Quick Guide DC-B1203X. Powered by

Achat 112 MA Achat 112 MA WH full-range speaker. user manual

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

TA12 full-rangespeaker. user manual

DDS 405 digital dimmer and switcher. user manual

ES630.1/ ES635.1 Lambda Module (1-CH) ES631.1/ ES636.1 Lambda Module (2-CH) User s Guide

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

HP4 headphone amplifier. user manual

a:touch Lite Universal control panel for Allen thermal transfer printers of the XL5000 series OPERATING INSTRUCTIONS

DDC-6, DDC-12 LCD DMX controller. user manual

LED Pixel Rail 40 RGB LED strip. user manual

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

INSTRUCTIONS FOR USE. RECHARGEABLE System for Hearing Aids

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Technical Documentation

HSP-SP V Release Notes HSP-SP V Release Notes. Page 1 of 6

PowerPlant Tuner tuner pedal with power distribution. user manual

38 MHz Passive Voltage Probe R&S RT-ZP1X

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

RTA-OS V850E2/GHS Release Note - Version ( )

CMC III Universal Sensor

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

VoiceLink User Guide. Life sounds brilliant.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

Technical Manual Sensor / Switch actuator 1/1gang; 2/1gang; 2/2gang

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

Flow Sensor SONOFLOW CO.55

CMSA-100 Manual. Cinema Media Server Automation

MA100 full-range speaker. user manual

NX8 Pocket Toner Users Guide

Card Enrollment Station. User Manual UD05870B

Installing and Configuring Rialto Analytic Appliances

ES6xx Add-On & Hardware Configuration Tool V1.4.0

LED Profile 150W 3200K. User manual. LED spotlight

HSP Update Tool V

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Transcription:

ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license. Using and copying is only allowed in concurrence with the specifications stipulated in the contract. Under no circumstances may any part of this document be copied, reproduced, transmitted, stored in a retrieval system or translated into another language without the express written permission of ETAS GmbH. Copyright 2017 ETAS GmbH, Stuttgart The names and designations used in this document are trademarks or brands belonging to the respective owners. Document ETAM3 R01_EN 04.2017 2

Contents Contents 1 About this Manual... 5 1.1 Identification of Safety Notices... 5 1.2 Presentation of Information... 5 1.3 Scope of Supply... 6 2 Basic Safety Notices... 7 2.1 General Safety Information... 7 2.2 Requirements for Users and Duties for Operators... 7 2.3 Intended Use... 7 2.4 Identifications on the Product... 9 2.5 Taking the Product Back and Recycling... 10 2.6 CE marking... 11 2.7 RoHS Conformity... 11 2.7.1 European Union... 11 2.7.2 China... 11 3 Introduction... 12 3.1 View... 12 4 Technical Data... 13 4.1 ECU Connector... 13 4.2 Electrical Characteristics for /TRST Signal... 13 4.3 Measurement Drawings... 14 4.4 Temperature Range... 14 5 Ordering Information... 15 6 ETAS Contact Addresses... 16 ETAM3 User s Guide 3

Figures Figures Figure 1: Adhesive Label (Example: Label for XETK-S14.0)...9 Figure 2: WEEE-Symbol... 10 Figure 3: View... 12 Figure 4: Pin Count... 13 Figure 5: Top View... 14 Figure 6: Side View... 14 ETAM3 User s Guide 4

About this Manual 1 About this Manual This chapter contains information about the following topics: Identification of Safety Notices on page 5 Presentation of Information on page 5 Scope of Supply on page 6 1.1 Identification of Safety Notices The safety notices contained in this manual are identified with the danger symbol shown below: The safety notices shown below are used for this purpose. They provide notes to extremely important information. Please read this information carefully. DANGER! indicates an immediate danger with a high risk of death or serious injury, if not avoided. WARNING! indicates a possible danger with moderate risk of death or (serious) injury, if not avoided. Caution! identifies a hazard with low risk that could result in minor or medium physical injuries or property damages if not avoided. 1.2 Presentation of Information All activities to be performed by the user are presented in a "Use Case" format. That is, the goal to be accomplished is briefly defined in the heading, and the respective steps required for reaching this goal are then presented in a list. The presentation looks as follows: Goal definition: any advance information... Step 1 Any explanation for step 1... Step 2 Any explanation for step 2... Step 3 ETAM3 User s Guide 5

About this Manual Any explanation for step 3... Any concluding comments... Typographical Conventions The following typographical conventions are used: Bold Labels of the device Italic Particularly important text passages Important notes for the user are presented as follows: Note Important notes for the user. 1.3 Scope of Supply Prior to the initial commissioning of the module, please check whether the product was delivered with all required components and cables (see chapter "Ordering Information"). Additional cables and adapters can be obtained separately from ETAS. A list of accessories and their order designation is available in this manual and at the ETAS Home Page. ETAM3 User s Guide 6

Basic Safety Notices 2 Basic Safety Notices This chapter contains information about the following topics: General Safety Information on page 7 Requirements for Users and Duties for Operators on page 7 Intended Use on page 7 Identifications on the Product on page 9" Taking the Product Back and Recycling on page 10 CE marking on page 11 RoHS Conformity on page 11 2.1 General Safety Information Please observe the Product Safety Notices ("ETAS Safety Notice") and the following safety notices to avoid health issues or damage to the device. Note Carefully read the documentation (Product Safety Advice and this User's Guide) that belongs to the product prior to the startup. ETAS GmbH does not assume any liability for damages resulting from improper handling, unintended use or non-observance of the safety precautions. 2.2 Requirements for Users and Duties for Operators The product may be assembled, operated and maintained only if you have the necessary qualification and experience for this product. Incorrect operation or operation by users without sufficient qualification may lead to injuries or death or property damages. General Safety at Work The existing regulations for safety at work and accident prevention must be followed. All applicable regulations and statutes regarding operation must be strictly followed when using this product. 2.3 Intended Use An ETK is an electronic component that is installed in a vehicle control unit (ECU) to read data from the ECU or write data to the ECU. Application Area of the Product This product was developed and approved for automotive applications. For use in other application areas, please contact your ETAS contact partner. Requirements for Operation The following requirements are necessary for safe operation of the product: Use the product only according to the specifications in the corresponding User's Guide. With any deviating operation, the product safety is longer ensured. Observe the regulations applicable at the operating location concerning electrical safety as well as the laws and regulations concerning work safety! Do not apply any voltages to the connections of the product that do not correspond to the specifications of the respective connection. Connect only current circuits with safety extra-low voltage in accordance with EN 61140 (degree of protection III) to the connections of the product. ETAM3 User s Guide 7

Basic Safety Notices The power supply for the product must be safely disconnected from the supply voltage. For example, use a car battery or a suitable lab power supply. Use only lab power supplies with double protection to the supply system. Ensure that the connections of the power supply are easily accessible. The module does not have an operating voltage switch. Switch on the product by connecting the power supply cable with the power supply or by switching on the power supply. Switch off the product by disconnecting it from the power supply or by switching off the power supply. DANGER! Connect the power cord only with a vehicle battery or with a lab power supply! A connection to power outlets is prohibited. Route the power cord in such a way that it is protected against abrasion, damages, deformation and kinking. Do not place any objects on the power cord. Never apply force to insert a plug into a socket. Ensure that there is no contamination in and on the connection, that the plug fits the socket, and that you correctly aligned the plugs with the connection. Do not use the product in a wet or damp environment. Do not use the product in potentially explosive atmospheres. Keep the surfaces of the product clean and dry. Potential Equalization Caution! Danger from inadvertent current flow! Depending on the design, the shield of the Ethernet cables can be connected with the housing of the module. Install the products only on components with the same electrical potential or isolate the products from the components. Requirements for the technical State of the Product The product is designed in accordance with state-of-the-art technology and recognized safety rules. The product may be operated only in a technically flawless condition and according to the intended purpose and with regard to safety and dangers as stated in the respective product documentation. If the product is not used according to its intended purpose, the protection of the product may be impaired. Maintenance and Cleaning The product is maintenance-free. Use a lightly moistened, soft, lint-free cloth for cleaning the product. Ensure that no moisture can enter. Never spray cleaning agents directly onto the product. Do not user any sprays, solvents or abrasive cleaners which could damage the product. Transport and Installation ETAM3 User s Guide 8

Basic Safety Notices Caution! The Product can be damaged or destroyed! Some components of the ETK board may be damaged or destroyed by electrostatic discharges. Please keep the ETK in its storage package until it is installed. The board should only be taken from its package, configured, and installed at a work place that is protected against static discharge. Caution! During installation and removal, ECU and ETK must be in a de-eenergized state! Caution! Risk of short circuiting the internal signals of the Product! When you mount the Product, you must ensure that the screws and washers used will not penetrate the Product printed circuit board. Caution! Differences in case ground potentials can cause high currents to flow through the shields of the cables that connect various system modules. Ensure that the module mounting surfaces are at the same electrical potential or insulate the modules from their mounting surfaces. Cabling Use exclusively ETAS cables at the connections of the product! Adhere to the maximum permissible cable lengths! Observe the assignment of the cables to the connectors! Detailed information about cabling is located in the ETK User's Guides. 2.4 Identifications on the Product Figure 1: Adhesive Label (Example: Label for XETK-S14.0) The following symbols are used for identifications of the product: Symbol Description The User's Guide must be read prior to the startup of the product! ETAM3 User s Guide 9

Basic Safety Notices Symbol Description Symbol for WEEE, see chapter 2.5 on page 10 Symbol for CE conformity, see chapter 2.6 on page 11 Symbol for China RoHS, see chapter 2.7.2 on page 11 Symbol for China RoHS, see chapter 2.7.2 on page 11 Symbol for electrostatic sensitive components XETK-S14.0A F 00K 110 722 SN: yyxxxxx XXXX/YY ZZZZ ETAS GmbH, PO Box 300220, 70442 Stuttgart, Germany Product designation (example) Order number of the product (example) Serial number (7-digit), depending on product Serial Number is not available. Product version Year of manufacture Manufacturer's address Note For symbols and product information one or several adhesive labels can be used. 2.5 Taking the Product Back and Recycling The European Union has passed a directive called Waste Electrical and Electronic Equipment, or WEEE for short, to ensure that systems are setup throughout the EU for the collection, treating and recycling of electronic waste. This ensures that the devices are recycled in a resource-saving way representing no danger to health or the environment. Figure 2: WEEE-Symbol ETAM3 User s Guide 10

Basic Safety Notices The WEEE symbol (see Figure 2 on page 10) on the product or its packaging shows that the product must not be disposed of as residual garbage. The user is obliged to collect the old devices separately and return them to the WEEE take-back system for recycling. The WEEE directive concerns all ETAS devices but not external cables or batteries. For more information on the ETAS GmbH Recycling software, contact the ETAS sales and service locations. 2.6 CE marking With the CE mark attached to the product or its packaging, ETAS confirms that the product corresponds to the applicable product-specific European Directives. The CE Declaration of Conformity for the product is available upon request. 2.7 RoHS Conformity 2.7.1 European Union The EU Directive 2011/65/EU limits the use of certain dangerous materials for electrical and electronic devices (RoHS conformity). ETAS confirms that the product corresponds to this directive which is applicable in the European Union. 2.7.2 China ETAS confirms that the product meets the product-specific applicable guidelines of the China RoHS (Management Methods for Controlling Pollution Caused by Electronic Information Products Regulation) applicable in China with the China RoHS marking affixed to the product or its packaging. ETAM3 User s Guide 11

Introduction 3 Introduction ETAM3 adapts ECU a 10 pin SAMTEC TFM-105 connector to an XETK. To increase to signalnoise ratio there is an buffer in the /TRST line supplied by the VDD(Sense) Voltage. L-FAST Mode is not possible with the ETAM3 adapter. 3.1 View Figure 3: View Note minimum bending radius for the flex foil is 3mm. ETAM3 User s Guide 12

Technical Data 4 Technical Data 4.1 ECU Connector In order to be able to use the ETK adapter ETAM3 in the ECU, a 10 pin SAMTEC connector (e.g. TFM-105-02-S-D-P) must be available on the ECU. JTAG or DAP mode depends on the used FETK or XETK. Figure 4: Pin Count Pin Number JTAG Mode DAP Mode 1 GND GND 2 TCK DAP0 3 /TRST /TRST 4 TDO DAP2 5 TMS DAP1 6 TDI - 7 WDGDIS WDGDIS 8 VDD (Sense) VDD (Sense) 9 /RESETOUT /RESETOUT 10 /PORESET /PORESET 4.2 Electrical Characteristics for /TRST Signal Supply /TRST Buffer Signal Condition VIHmin VIHmax VDD(Sense) ECU on 3.0V 5.5V /TRST Output Signal Signal Condition VOHmin VOHmax VOLmax /TRST /TRST VDD(Sense)=3V IOH = 4mA VDD(Sense)=4.5V IOH = 8mA 2.34V VDD(Sense) 0.52V 3.66V VDD(Sense 0.52V ETAM3 User s Guide 13

Technical Data 4.3 Measurement Drawings Measured in mm Figure 5: Top View Figure 6: Side View 4.4 Temperature Range Condition Operating Temperature Temperature -40 C - +110 C ETAM3 User s Guide 14

Ordering Information 5 Ordering Information Short Name Order - Number ETAM3 F 00K 109 673 ETAM3 User s Guide 15

ETAS Contact Addresses 6 ETAS Contact Addresses ETAS HQ ETAS GmbH Borsigstraße 14 Phone: +49 711 3423 0 70469 Stuttgart Fax: +49 711 3423 2106 Germany WWW: www.etas.com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php ETAM3 User s Guide 16