High dynamic range magnetic resonance flow imaging in the abdomen

Similar documents
High dynamic range fusion of magnetic resonance flow imaging data

Compressed Sensing Reconstructions for Dynamic Contrast Enhanced MRI

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Compressed Sensing for Rapid MR Imaging

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

Sparse sampling in MRI: From basic theory to clinical application. R. Marc Lebel, PhD Department of Electrical Engineering Department of Radiology

MR Advance Techniques. Vascular Imaging. Class III

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Enhao Gong, PhD Candidate, Electrical Engineering, Stanford University Dr. John Pauly, Professor in Electrical Engineering, Stanford University Dr.

Information about presenter

Estimating Arterial Wall Shear Stress 1

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Classification of Abdominal Tissues by k-means Clustering for 3D Acoustic and Shear-Wave Modeling

G Practical Magnetic Resonance Imaging II Sackler Institute of Biomedical Sciences New York University School of Medicine. Compressed Sensing

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Blind Local Noise Estimation for Medical Images Reconstructed from Rapid Acquisition

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

Magnetic Resonance Elastography (MRE) of Liver Disease

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

Deep Learning for Fast and Spatially- Constrained Tissue Quantification from Highly-Undersampled Data in Magnetic Resonance Fingerprinting (MRF)

6 credits. BMSC-GA Practical Magnetic Resonance Imaging II

Role of Parallel Imaging in High Field Functional MRI

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

4D MRI phase-contrast image to determinate blood flow patterns in aorta

MODEL-BASED FREE-BREATHING CARDIAC MRI RECONSTRUCTION USING DEEP LEARNED & STORM PRIORS: MODL-STORM

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

Separate Magnitude and Phase Regularization via Compressed Sensing

SPM8 for Basic and Clinical Investigators. Preprocessing

Deep convolutional neural networks for accelerated dynamic magnetic resonance imaging

Collaborative Sparsity and Compressive MRI

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

Nuts & Bolts of Advanced Imaging. Image Reconstruction Parallel Imaging

Generation of Hulls Encompassing Neuronal Pathways Based on Tetrahedralization and 3D Alpha Shapes

Super-resolution Reconstruction of Fetal Brain MRI

An Iterative Approach for Reconstruction of Arbitrary Sparsely Sampled Magnetic Resonance Images

Skåne University Hospital Lund, Lund, Sweden 2 Deparment of Numerical Analysis, Centre for Mathematical Sciences, Lund University, Lund, Sweden

Functional MRI in Clinical Research and Practice Preprocessing

Efficient MR Image Reconstruction for Compressed MR Imaging

4D Magnetic Resonance Analysis. MR 4D Flow. Visualization and Quantification of Aortic Blood Flow

Accelerated 4D flow MRI

Digital Volume Correlation for Materials Characterization

Combination of Parallel Imaging and Compressed Sensing for high acceleration factor at 7T

A Model-Independent, Multi-Image Approach to MR Inhomogeneity Correction

ADAPTIVE GRAPH CUTS WITH TISSUE PRIORS FOR BRAIN MRI SEGMENTATION

NIH Public Access Author Manuscript Proc Soc Photo Opt Instrum Eng. Author manuscript; available in PMC 2014 October 07.

FMRI Pre-Processing and Model- Based Statistics

Learning Algorithms for Medical Image Analysis. Matteo Santoro slipguru

K-Space Trajectories and Spiral Scan

Institute of Cardiovascular Science, UCL Centre for Cardiovascular Imaging, London, United Kingdom, 2

Interpolation of 3D magnetic resonance data

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

A Spatio-temporal Denoising Approach based on Total Variation Regularization for Arterial Spin Labeling

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

CHAPTER 2. Morphometry on rodent brains. A.E.H. Scheenstra J. Dijkstra L. van der Weerd

A Novel Iterative Thresholding Algorithm for Compressed Sensing Reconstruction of Quantitative MRI Parameters from Insufficient Data

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

Improving Reconstructed Image Quality in a Limited-Angle Positron Emission

Locally Weighted Least Squares Regression for Image Denoising, Reconstruction and Up-sampling

NIH Public Access Author Manuscript Med Phys. Author manuscript; available in PMC 2009 March 13.

Towards an Estimation of Acoustic Impedance from Multiple Ultrasound Images

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

Quantifying Three-Dimensional Deformations of Migrating Fibroblasts

The University of Chicago. Center for EPR Imaging in Vivo Physiology. Image Registration. Boris Epel

Redundancy Encoding for Fast Dynamic MR Imaging using Structured Sparsity

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Application of level set based method for segmentation of blood vessels in angiography images

3D3C & 2D3D Velocity Measurements Using Magnetic Resonance Velocimetry

Evaluation of Local Filter Approaches for Diffusion Tensor based Fiber Tracking

Automated segmentation of blood-flow regions in large thoracic arteries using 3D-cine PC-MRI measurements

General and Efficient Super-Resolution Method for Multi-slice MRI

k-space Interpretation of the Rose Model: Noise Limitation on the Detectable Resolution in MRI

Isogeometric Analysis of Fluid-Structure Interaction

Learning a Spatiotemporal Dictionary for Magnetic Resonance Fingerprinting with Compressed Sensing

MRI reconstruction from partial k-space data by iterative stationary wavelet transform thresholding

Partial k-space Recconstruction

Development of fast imaging techniques in MRI From the principle to the recent development

Dosimetric Analysis Report

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

Total Variation Regularization Method for 3-D Rotational Coronary Angiography

Total Variation Regularization Method for 3D Rotational Coronary Angiography

IMAGE DE-NOISING IN WAVELET DOMAIN

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

Super-Resolution Reconstruction of Diffusion-Weighted Images from Distortion Compensated Orthogonal Anisotropic Acquisitions.

3D Radial Undersampling 7/19/2012. Artifact Removal SNR Restoration-- HYPR. Background: Time Resolved MR Angiography 4D DSA AND 4D FLUOROSCOPY:

Introduction. Wavelets, Curvelets [4], Surfacelets [5].

Correction of Partial Volume Effects in Arterial Spin Labeling MRI

A Study of Medical Image Analysis System

Magnetic Resonance Angiography

Phase Difference Reconstruction. Outline

Introduction to Neuroimaging Janaina Mourao-Miranda

Basic fmri Design and Analysis. Preprocessing

Multi-Dimensional Flow-Preserving Compressed Sensing (MuFloCoS) for Time-Resolved Velocity-Encoded Phase Contrast MRI

Partial k-space Reconstruction

Visualization and Quantification of Helical Flow in the Aorta using 4D Flow MRI

Transcription:

High dynamic range magnetic resonance flow imaging in the abdomen Christopher M. Sandino EE 367 Project Proposal 1 Motivation Time-resolved, volumetric phase-contrast magnetic resonance imaging (also known as 4D flow MRI) is a powerful clinical tool used by radiologists to simultaneously assess cardiovascular anatomy, flow, and function [1]. With raw data acquired in one 8-10 minute scan, both anatomical and flow images can be reconstructed by encoding tissue velocity information into the phase of the raw MRI signal. The velocimetric dynamic range of 4D flow MRI is inherently limited, however. Since signal is measured in quadrature (via real and imaginary channels), the principal value of the complex MRI signal can only take on values in the range ( π, +π]. Thus, there is a maximum encodable velocity also known as venc. This is a prescribable parameter which determines the range of velocities ( venc, +venc] which are directly measurable from a single scan. To avoid velocity aliasing (also known as phase wrapping), the venc is set higher than the highest velocity that the MRI technician expects to measure. However, scanning with higher venc s comes at the cost of velocity-to-noise ratio (VNR). This becomes detrimental in abdominal flow imaging due to the presence of a high dynamic range of flow velocities in the abdomen. The venc must be set high to capture fast flow dynamics, making VNR too low to resolve slow flow dynamics (See Figure 1). In this work, I will propose a scheme where multiple 4D flow datasets are acquired with different venc s, and then fused together using a regularized high dynamic range post-processing technique to precisely and accurately depict both fast and slow flow. This technique would not only help streamline visualization of this high-dimensional data, but also increase precision and accuracy of biomarkers which are derived from flow data such as peak velocity, flow, wall shear stress, and turbulent kinetic energy. 2 Related Work The velocimetric dynamic range of 4D flow MRI has previously been extended in three ways: a) high VNR velocity encoding [2] b) phase unwrapping techniques [3,4], and c) multi-venc flow imaging [5,6]. The performance of the first technique is highly dependent on spatial and temporal resolution especially in fatty areas such as the abdomen. For this proposal, I will focus on the second and third techniques. Phase unwrapping is a well-studied image processing technique that has recently been applied to 4D flow in order to undo velocity aliasing in low venc acquisitions (See Figure 2). By estimating four-dimensional (space and time) gradients in the raw phase data, algorithms find and undo 1

phase wraps by locating areas with local jumps of 2π. This can be done non-iteratively by analytically solving Poisson s equation [3], or iteratively by weighted least squares [4]. In general, phase unwrapping has been shown to be non-robust in 4D flow data, and its performance is highly dependent on patient anatomy and physiology. Multi-venc 4D flow MRI is another technique that extends dynamic range by acquiring multiple datasets using different venc s and then using high venc datasets to unwrap phase in low venc datasets. Algorithms look at element-wise differences between low and high venc data, and locate phase wraps by thresholding voxels with differences above 2π [5]. However, acquiring multiple 4D flow datasets is costly, so most techniques propose only acquiring two datasets with one high and one low venc [6]. In the end, most of the high venc data is thrown away since low venc data is replaced with high venc data only where wraps occur. While this technique has shown to be highly robust to velocity aliasing, its use of data is inefficient. 3 Project Overview For my project, I will apply the high dynamic range processing technique [7] to reconstruct multi-venc 4D flow datasets using as much of the raw data as possible. Given magnitude images M i R m and velocity images V i R m acquired with venc i for i {1,..., n}, estimate composite HDR velocity image ˆV by the following least absolute shrinkage and selection operator (LASSO) minimization: n minimize W i (V i ˆV ) 2 2 + λ Ψ( ˆV ) 1 i=1 W ij = w VNR (M ij )w wrap (venc i ) This minimization problem can be solved using a simple weighted average for λ = 0, or the alternating direction method of multipliers (ADMM) for λ > 0. The design of the cost function can be decomposed into two problems: Designing the weights: Assuming that the highest venc dataset has no velocity aliasing (as are datasets acquired in the clinic), we can roughly estimate which voxels in the low venc datasets are wrapped and weigh against them. We can also weigh against measurements with low VNR, a parameter that can be estimated from corresponding magnitude data. Incorporating a priori information: An l 1 -regularization term is introduced to incorporate prior information into the reconstruction of composite HDR images. This could be a total variation penalty to enforce flow smoothness, although this may not necessarily be true in the presence of flow jets caused by narrow vessels. It could also be a divergence penalty, which has previously been used to denoise 4D flow data [8]. This idea derives from a classical fluid dynamics result that flow fields have zero divergence (incompressibility). Below I have outlined two experiments I will perform for this project, as well as one optional experiment that I may or may not complete depending on time: 1. HDR phantom simulations: From a previous project, I have Matlab code that can simulate 4D flow data acquired with different venc s (See Figure 3). The HDR method with different priors and values of λ will be applied and evaluated by computing RMSE and PVNR (peak velocity-to-noise ratio) between HDR images and ground truth images. I will also investigate how many different venc images are required to get good results. 2

2. HDR in-vivo: The HDR method will also be applied to in-vivo multi-venc abdominal data, which has yet to be acquired. Through access to the MRI scanners at Stanford Lucas Center, I will be able to scan a volunteer from my lab. In this experiment, I will not have a ground truth, since fully-sampled 4D flow datasets take hours to acquire, and no volunteer (or patient) will want to sit in the scanner for hours. Therefore, the evaluation will be mostly qualitative. 3. HDR + super-resolution (optional): In order to address the long scan time required to acquire a multi-venc dataset, one could undersample each venc dataset, or a subset of the datasets. Then, the HDR objective function would require the modification: minimize n W i (AV i ˆV ) 2 2 + λ Ψ( ˆV ) 1 i=1 where A is an interpolation or super-resolution matrix, which artificially increases the spatial and/or temporal resolution of the inputs V i. 4 Timeline 1. Week 1 (2/13-2/19): Develop HDR code (weighted average and ADMM implementation) in Matlab 2. Week 2 (2/20-2/26): Phantom simulations, acquire in-vivo data 3. Week 3 (2/27-3/5): Apply HDR to in-vivo data 4. Week 4 (3/6-3/12): Begin making poster, attempt super-resolution problem 5. Week 5 (3/13-3/17): Present poster, write final report 3

5 Figures Figure 1: High venc vs. low venc. Two abdominal 4D flow datasets obtained with venc s of (a) 120 cm/s and (b) 50 cm/s. Color velocity data is scaled from 0 to 50 cm/s and overlaid on top of grayscale magnitude data. As shown here, low-venc data is prone to velocity aliasing in high velocity structures (black arrows), but offer much better low velocity resolution as seen by the renal and hepatic vasculature (white arrows). The idea behind this project is to use HDR techniques to combine two (or more) datasets like these into one composite dataset with good low velocity resolution and without velocity aliasing. 4

Figure 2: Performance of three phase unwrapping algorithms on low-venc abdominal data. 4D raw phase data is projected down onto a 2D coronal slice of the abdominal aorta. Phase wraps in each image are denoted by white arrows. Figure 3: Simulated flow data. 4D flow data (magnitude and phase) of ideal cylindrical vessels can be simulated using a common computational fluid dynamics algorithm known as the Womersley method. This data can be simulated for arbitrary spatial resolution, temporal resolution, venc, and peak velocity. Velocity profiles for both arterial (red) and venous (blue) vessels are shown here. 5

6 References 1. M. Markl, F. Chan, M. Alley, K. Wedding, M. Draney, C. Elkins, D. Parker, R. Wicker, C. Taylor, R. Herfkens, and N. Pelc, Time-resolved three-dimensional phase-contrast MRI, J Magn Reson Imaging, vol. 17, no. 4, pp. 499-506, 2003. 2. K. Johnson and M. Markl, Improved SNR in phase contrast velocimetry with five-point balanced flow encoding, Magn Reson Med, vol. 63, no. 2, pp. 349-355, 2010. 3. M. Loecher, E. Schrauben, K. Johnson, and O. Wieben, Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithm, J Magn Reson Imaging, vol. 43, no. 4, pp. 833-842, 2016. 4. C.M. Sandino, J.Y. Cheng, M.T. Alley, and S. S. Vasanawala, Precision weighted leastsquares phase unwrapping of abdominal 4D flow MRI data, Proceedings of the ISMRM Workshop on Quantitative MR Flow. San Francisco, CA, USA, 20-23 October 2016. 5. A. Lee, G. Pike, and N. Pelc, Three-Point Phase-Contrast Velocity Measurements with Increased Velocity-to-Noise Ratio, Magn Reson Med, vol. 33, no. 1, pp. 122-126, 1995. 6. S. Schnell, J. Garcia, C. Wu, and M. Markl, Dual-velocity encoding phase-contrast MRI: Extending the dynamic range and lowering the velocity-to-noise ratio, Proc. Intl. Soc. Mag. Reson. Med., vol. 23, 2015. 7. P. E. Debevec and J. Malik, Recovering high dynamic range radiance maps from photographs, SIGGRAPH, 1997. 8. F. Ong, M. Uecker, U. Tariq, A. Hsiao, M. Alley, S. Vasanawala, and M. Lustig, Robust 4D flow denoising using divergence-free wavelet transform, Magn Reson Med, vol. 73, no. 2, pp. 828-842, 2015. 6