Dual-Angle Imaging Camera for Determination of Dielectric Thin Film Thickness Product Requirements Document Professor. Jennifer Kruschwitz

Similar documents
Tuberculosis Detection by Purified Protein Injection Product Requirements Document Team TB

Development of Digital Visualization Tool: Visual Image Simulation (VIS) DigitEyez / Brandon Zimmerman

NANOSPEC 4150 STANDARD OPERATING PROCEDURES

Up.Periscope Product Requirements Document

R I T Title: Nanometrics Nanospec AFT #1 Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 03/28/2011

Mu lt i s p e c t r a l

Quality inspection systems for pharmaceutical packing process

SAGE SCIENCE INC. BluePippin Installation Guidelines Rev. A Originated March 9, 2015 Revised: Page 1 of 7. Prepared by: Alex Vira SUMMARY

X-Rite MA98 Portable Multi-Angle Spectrophotometers

Visible-frequency dielectric metasurfaces for multi-wavelength achromatic and highly-dispersive holograms

Project Goals: Particle size distribution with shape information (roundness, aspect ratio) with highest precision and accuracy.

2 Bit Micro,LLC 2BM-20050(-TS)

10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan


Technical Specification. for. 10 Gbps SFP+ Checker

SAGE SCIENCE INC. PippinHT Installation Guidelines Rev. B Originated November 21, 2014 Revised December 2, 2014.

Vineon. Technology. Features:

SC20MPC: 2 Mega Pixels Serial JPEG Camera User Manual. Introduction

Product Specifications

Manual. Infrared cameras. Contour M

Mike Pendley Instrumentation and RF Engineer

Sample study by 3D optical profiler Contour Elite K for KTH university.

PTZ Conference Room USB Camera

PRODUCT SPECIFICATION

LED..O..M Series Diffused On-Axis Lights

Viano. Chitula Chipimo CSE. Christopher Cunniff CSE. Anna Wildman EE. Kelly Kennedy EE. Advisor: Professor Anderson

SWIR Vision Systems Acuros TM CQD TM SWIR Cameras. November 2018 SWIR VISION SYSTEM

premier & acculase modulatable/machine vision lyte mv/dragonfly/ standard cw operation imatronic/laserlyte/laserlyte-flex/guideline/

USB C PD 50W Portable Power Dock Adapter for Notebooks with Built-In HDMI Output

DATA SHEET RECEIVED CDAE CUSTOMER DESIGNER CHECKER APPROVER

Model S471 Portable Optometer

EPSON Perfection 640U. Scanner Parts. Scanner Specifications. Basic Specifications. 600 dpi (main scan) 2400 dpi. resolution*

R I T. Title: Rudolf Ellipsometer Auto-EL IV. Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date:12/07/17 1 SCOPE

CMOS USORIA. Features

Current DC (ma) Storage Temp. ( C) Red 1.85 Vdc D. Voltage Vac/dc

SVD-4120A SSNR Low Light, WDR, Day & Night Vandal-Proof Color Dome Camera

Specifications: LED Ring Lights. Product Number

LLM. Digital Input Channels. Mount DIN. Warranty RAIL. Manage multiple lights operating in continuous, Multi-Drive, or OverDrive modes

OPTIC-2 OPTICAL CAMERA DETECTOR

SC03MPC: 0.3 Mega Pixels Serial JPEG Camera Infrared User Manual. Introduction

Fraunhofer Demo Day. Integrated Micro Camera Devices Dr. Michael Töpper, Dr. Andreas Ostmann Martin Wilke, Prof. Dr. Lang

InfoVision Optoelectronics ( Kunshan ) Co.,LTD. Document Name Document No.

Product Specifications

TFT NHD EF CTXI# Diagonal. Model. Fax: Ph:

UHP-M Ultra-High Power UV-Visible LED Light Source Fluorescence Microscopy Ver. 04

G-Series. Epson. Robots. G-Series. Epson. Robots. The Epson G-series SCARA : Greater performance higher productivity

UHD 185 FAQs. Optical System

TRUESCAN. Introduction

BYK-mac. Total color impression of effect finishes. Ergonomic design and easy operation. Reliable readings at any time

User manual TaBleT l7 3G

# F TFT NHD EF CTXI# Diagonal. Model. Fax: Ph:

NHD EF-CTXI#

Phantom v7.3. Phantom v7.3. Datasheet. Mechanical Drawing. Sensor Spectral Response 1 / 10

Specification Sheet FPI lab

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

The Imaging Source USB 3.0 Series Cameras DMK 23U274 / DFK 23U274

Super high resolution cooled astronomical camera QHY27/28/29M. User s Manual Rev. 1.0

Introduction to Computer Vision. Introduction CMPSCI 591A/691A CMPSCI 570/670. Image Formation

Title: Heidelberg DWL66+ Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 05/03/2017

The SC03MPA camera is capable of outputting JPEG format images and PAL/NTSC video (Video is available only per request).

CS201 Computer Vision Lect 4 - Image Formation

LLM. Digital Input Channels. Mount DIN. Warranty RAIL. Manage multiple lights operating in continuous, Multi-Drive, or OverDrive modes

PL-D755 CMOS SONY IMX250 GLOBAL SHUTTER KEY FEATURES TYPICAL APPLICATIONS 5.01 MP

Fixed mount CCD bar code reader NFT Specification Ver. 1.0

FC Series Traffic Camera. Architect & Engineering Specifications

Lens Films and Refl ective Polarization Films

Large Animal Videoendoscopes VET /2017-E

Precision digital measuring device PHYSICS 51

Boson Lens Calibration

Peak Detector. Minimum Detectable Z Step. Dr. Josep Forest Technical Director. Copyright AQSENSE, S.L.

Operating Procedure for Horiba Raman Microscope

Rigid Body Motion and Image Formation. Jana Kosecka, CS 482

Optical Topography Measurement of Patterned Wafers

NHT-310. Broadband EM Field Meter: DC 40 GHz. HAVSCo LTD. Key Features:

User s Manual. ASE-1019 ASE Light Source

User Manual. Borescope. Model THE STANDARD IN PRECISION MEASUREMENT

NANOMETRIC LAB PRINTER. Plug & Play Solution for ultra-precise printing of conductive lines in nano-scale

DENTAL WEAR SURFACE USING 3D PROFILOMETRY

RayVio XE Series UV LEDs

Minutes. Action items Person responsible Deadline Develop LabView code to our liking. N/A Keep adjusting Matlab. Ben

LightBend TM Dual 2x2 Bypass Multimode Fiberoptic Switch

scs1 highlights Phone: Fax: Web:

FC Lens series for Cree XLamp 7090 XR and XR-E LEDs

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

Panasonic AK-HC /3" 2.2M 1080i Native 3-CCD HD Studio Camera. Version anglaise seulement. Information uniquement en anglais

CMOS SONY IMX250 GLOBAL SHUTTER mm. Biometrics Medical Imaging PCB & Flat Panel Display Insection

Item Symbol Absolute Maximum Rating Unit Remarks

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

LaserLyte-Flex Red & Green Alignment System

NHD ZF CTXL#

Cyclops Explorer Product Overview and Instructions

# T TFT NHD EF CTXI# Diagonal. Model. Fax: Ph:

A Global Laser Brand. Versatile Module

Manta G Megapixel GigE Vision compliant camera. Benefits and features: Options:

PRODUCT SPECIFICATION FOR LCD MODULE APPROVED SIGNATURE. Approved Product Specification only Approved Product Specification and Samples

Comprehensive Scope 2. Instruction Manual T-19011C - Monocular T-19021C - Dual Viewing T-19031C - Binocular T-19041C - Trinocular

Technical Data Sheet 5mm POWER LED

10.4 Interference in Thin Films

Manta G Megapixel GigE Vision camera with Sony ICX655 CCD sensor. Benefits and features: Options:

SPECTRAL IMAGING VIEWER SOFTWARE MANUAL

Transcription:

Dual-Angle Imaging Camera for Determination of Dielectric Thin Film Thickness Product Requirements Document Professor. Jennifer Kruschwitz Customer has reviewed and approved the final product review document. Yang Deng Diana Magana Zheng Tan Document Number 00005 Revisions Level Date E 12-11-2017 This is a computer-generated document. The electronic master is the official revision. Paper copies are for reference only. Paper copies may be authenticated for specifically stated purposes in the authentication block. Authentication Block

Rev A Dual-Angle Imaging Camera for Determination of Dielectric Thin Film Thickness Description Initial PRD Date 10-23-2017 Authorization DM, YD B Updated 11-11-2017 DM, YD specifications from first three customer meetings C Updated: 11-25-2017 YD Responsibility and changes after first test D Updated according to 12-07-2017 DM, YD project progress E Updated: Responsibilities, fitness for use, 12-11-2017 DM, YD i

Table of Contents Statement of Advisor 1 Vision 1 Environment 1 Regulatory Issues 2 Fitness for use 2 Proposed System Design 3 Project Outline 4 Timeline 5 ii

Statement of Advisor: The Dual-Angle Imaging Camera is currently being developed as a spectrophotometer to determine dielectric thin film thickness. It has been shown that the dual- angle imaging camera has the potential to be a new method for thin film thickness measurement. The camera is currently developed under supervision of Dr. Jennifer Kruschwitz, a professor in the Institute of Optics, University of Rochester. Vision: The product is a dual-angle camera imaging system for determining dielectric thin film thickness in the RIT Microelectronics Cleanroom Lab. The product should be ready to use at the end of this project. Environment: As a device intended for clean room microelectronic measurements, it needs to operate in the following environment: Temperature 15 to 35 C operation range Relative Humidity 40 to 50% (no condensation) operation range It will operate under outlet power and 4 AA batteries for the LED light source. page 1

Regulatory Issues: The dual-angle camera imaging system currently does not have regulatory issues. Fitness for use: The dual-angle camera imaging system consists of a white 1D diffused backlight LED light source, a color camera, and lenses that are required to project LED image onto color camera with at least 10-degree angle separation between the edge and the center of the image. Spectrum of LED does not matter because it will be divided out using a bare silicon wafer to white balance the image. This will be done on MATLAB by converting image to double format in order to do math with the matrices of information. The dual-angle camera imaging system is designed to capture two images of the specular highlight (color) from light source that is being reflected from a one-layer film with an uniform thickness of 3nm-10nm from two different angles with a uniform thickness of 0-600nm and we will need to figure out the accuracy as we go.. The difference between two angles should at least be 10 degrees. The dual-angle camera imaging system will: Have the camera and white LED source at a fixed angle that optimize the match rate between measured sample thin film thickness and provided sample thin film thickness Have a CCD camera that is compatible with MATLAB and is calibrated with color checker for optimal gamma. Have a lens system that provide images with 10-degree center-to-edge separation Have a stage that is encapsulated or out in the open in a fixed position Be entirely clean according to standard at RIT Microelectronic Cleanroom Lab. Work for films on a silicon wafer. It is desirable that: The total cost of the dual-angle camera imaging system is under $1000. A user-friendly GUI is developed to reduce operation difficulty. If there is time and/or team resources available: A dual-angle camera imaging system will be integrated into a portable plug-inand-play instrument that can be easily carried and operated with necessary instructions given. page 2

Works for films deposited on a silicon nitride wafer and silicon dioxide wafer Specification White Light LED Vendor Adafruit Part No. KWB-R3912W/1W Ilumination Size 12*14mm Max. Reserve Voltage 5V Max. Forward Current 25mA Max. Power Dissipation 90mW Color Camera Vendor Edmund Optics Part No. BFLY-U3-05S2C-CS Manufactuer FLIR Connector USB3.0 Pixel Depth 16 bit Lens System Desgin Requirement Minimum image edge to center angle 10 degree Test lens will be borrowed from the Institute Proposed System Design: page 3

Project Outline: Camera Characterization System Design & Build up System Test (Imaging Only) MATLAB Evaluation Code Improvement System test (Code and Calibration Sample included) GUI Development Intergrated Package for the Device Delivery to RIT What we are responsible for: We are responsible for the design and development of the dual-angle imaging camera including imaging test with developed MATLAB code and calibrated samples. If time permits, we are also responsible for the user-friendly GUI development and device package design. What we are not responsible for: We are not responsible for creating the coating reflectance database and procuring the calibration samples. These parts are performed at RIT and should be delivered to us by the start of spring semester, if not Professor Kruschwitz will ask UR Nano lab to fabricate the samples for us. page 4

Timeline: Fall Semester Camera Characterization System Design Final PRD Name for the device - Winter Break Spring Semester System Build up System Test (Imaging Only) MATLAB Evaluation Code Improvement System test (Code and Calibration Sample included) GUI Development Intergrated Package for the Device Delivery to RIT Group Member Responsibility: Diana: Scribe, device testing, package design Yang: Project coordinator, MATLAB code, system build up Zheng: Customer liaison, lens system design, system build up page 5