Instruction Manual Power Distribution System SVS16-PN-XX

Similar documents
Instruction Manual Power Distribution System SVS16-EN-XX

Power distribution system SVS16-PB

G5 Weighing Instrument

User Manual Gateway component for EtherNet/IP

Profinet Module. User Manual. Contents

mipick Pick-by-Light System

Operating instructions IO-Link master CabinetLine AL19xx

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Ethernet/IP Module. User Manual. Contents

Date Revision Change(s) 29/07/ First version

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

Solid State Remote Power Controller E /627

Ethernet/SIOX Gateway Applicable to firmware ver 1.0

crio PN Installation Instructions V0.2/ COMSOFT

ETHERNET/IP & PROFINET MODULE

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Communication settings: Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server

Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server.

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

SK CU4-EIP-C Part number:

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

User manual Gateway component Sercos

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status.

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

SK CU4-PNT-C Part number:

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Contents User Manual For PIM

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

BL compact multiprotocol fieldbus station for Industrial Ethernet SSI Interface BLCEN-1M12MT-1SSI

Electronic Overcurrent Protector REF16-S

Anybus.NET Bridge PROFIBUS

BL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I

Operating Instructions Electronic Circuit Protector ESX10-TC-DC 12 V

Fieldbus slave modules w/o I/Os

Operating Manual FPGA-based High-Speed Micro-PLC

Operating Instructions IO-Link Master with Modbus TCP interface DataLine 8 Ports IP 65 / IP 66 / IP 67 AL1342

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P

ECN module MGC-PRO MicroDrive

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Additional instructions Videographic recorder LINAX DR3000. PROFINET Device

Compact Multiprotocol I/O Module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE for your PROFINET application

DALI Professional Controller-4. Control unit Operating instructions

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

DF PROFINET IO CPCI. Installation Instructions V1.3/ KUNBUS

Compact Multiprotocol I/O Module for Ethernet 8 IO-Link Master Channels 4 Universal Digital PNP Channels, 2 A, Channel Diagnostics TBEN-L5-8IOL

Data sheet CPU 015PN (015-CEFPR01)

Operating Instructions IO-Link Master with EtherNet/IP interface DataLine 4 Ports IP 65 / IP 66 / IP 67 AL1320

Copyright: December 2017 Nidec Issue: E

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

C-DIAS EtherNet/IP Slave CIP 022

Compact Multiprotocol I/O Module for Ethernet 16 Digital PNP Outputs TBEN-L4-16DOP

SCHMIDT Sensor interface PROFIBUS Instructions for use

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

Date Revision Change(s) First version Firmware Update 1.5

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

Operating instructions RFID evaluation unit DTE / / 2016

EX2 Ethernet/SIOX Controller p 2. General Description Block Diagram

Ethernet Module MGC-PRO MicroDrive

Manual. Fieldbus Interface DFE33B EtherNet/IP and Modbus/TCP. Edition 10/ / EN

AS-i Safety Relay Output Module with Diagnostic Slave

Compact multiprotocol I/O module for Ethernet 4 Analog Inputs, Configurable as Voltage, Current, RTD or Thermocouple TBEN-S2-4AI

Altivar - Lexium. Option modules DANGER S1A S1A /8 VW3A3601 / VW3A3608 VW3A3616 / VW3A3627 VW3A3619 VW3A3720 VW3A3721 VW3M3308

Operating and mounting instructions

Revision. Decentralized Drive and Application Control MOVIPRO ADC with PROFINET interface * _1017*

ETHERNET/MFC 010 Technical Datasheet

Indu-Sol GmbH Specialist in fieldbus technologies INBLOX. User Manual. Diagnostic and service tools for PROFIBUS

SmartRail I/O Ethernet Base HE599ETX300

UNIGATE UNIGATE CM CM GATEWAY SERIES. CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL ETHERNET. Easy installation. Norm compliant.

EGW1-IA3-MB User s Manual

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Kit for Simple I/O Communication via Ethernet Modbus/TCP/ EtherNet/IP / PROFINET in IP67 TI-BL67-EN-S-8

Date Revision Change(s) First version

Type code. TBEN-S2-4IOL Ident no Supply. Total current max. 4A per voltage group

Compact multiprotocol I/O module for Ethernet 16 digital PNP outputs TBEN-L1-16DOP

Rack Installation Instruction

FACTORY AUTOMATION. MANUAL ICE1-8DI8DO-G60L-V1D ICE1-8DI8DO-G60L-C1-V1D ICE1-16DI-G60L-V1D Fieldbus Modules with Multiprotocol Technology

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392

Valve island VM10 with PROFINET Interface 8, 10, 12 or 16 stations. Operation & Service Manual

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

Compact Multiprotocol I/O Module for Ethernet 16 Digital PNP Inputs TBEN-L5-16DIP

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

TECHNICAL DOCUMENTATION

Transcription:

Instruction Manual Power Distribution System SVS16-PN-XX

2

Contents 1 General...4 1.1 General mounting guidelines...4. 2 Bus-capable power distribution system SVS16-PN-XX...5 2.1. Overview...5 2.2. Schematic diagram (SVS16-PN-16 shown)...5 2.3. Termination...6 2.3.1. Supply voltage load module...6 2.3.2. Supply voltage bus module...6 2.3.3. Load outputs...6 2.3.4. F-slots...7 2.4. Operating modes...7 2.5. Behaviour in the absence of a bus connection...7 2.6. Addressing...8 2.6.1. General information and operating modes...8 2.6.2. Fieldbus-specific unit search / address assignment...9 2.6.3. Standard functions for address assignment...9 2.7. Setting of the EtherNet ports...9 2.8. Configuration of SVS16-PN...10 2.9. LED indication for bus communication (PROFINET)...11 2.10. Signalling of the various operating modes...12 2.11. Operating modes of the power distribution system...12 2.11.1. Operating mode: SYSTEMINIT...12 2.11.2. Operating mode: FREEZE...12 2.11.3. Operating mode: UNFREEZE...12 2.11.4. Operating mode: UNIT_ADRESSING...12 3 Firmware of the Anybus version... 13. 3

1 General The power distribution system SVS16-PN-XX offers selective overcurrent protection, power distribution of load circuits as well as connecting and resetting of outputs. The system is fitted with a fully-fledged PROFINET interface to ensure a consistent communication of status and failure conditions as well as switching / resetting of individual circuits on the DC 24 V level. The system has been designed for rail mounting and has 8 (SVS16-PN-08) or 16 (SVS16-PN-16) slots. The slots can optionally accommodate electronic circuit protectors type ESX10-(S)125 (with reset input and status output), ESX10-(S)115 (with control input and status output) or with the SSRPC E-1048-S7xx (with control input and status output). 1.1. General mounting guidelines The power distribution system must only be installed by qualified personnel. Only after expert installation must the device be supplied with power. It is only intended for use with safety extra-low voltage (= 24 V DC). Connection to a higher or not reliably disconnected voltage can cause hazardous conditions or damages. The max. total current of the power distribution system must not be exceeded In each load branch the cable cross section and the current rating of the protective component must be adjusted to the current rating of the connected load. The technical data of the used circuit protectors have to be observed. The Machinery Directive 2006/42/EC and EN 60204-1, Safety of Machines requests special precautions to be taken in the system or machine (e.g. using a safety PLC) to prevent inadvertent start-up of the system or parts of the system. In the event of a failure (short circuit/overload) the load circuit will be disconnected by the circuit breaker/protector. After tripping of the circuit protector, before reset, the cause of tripping (short circuit or overload) has to be remedied. The national standards (e.g. for Germany DIN VDE 0100) and selection of appropriate ingoing and outgoing cables have to be observed. Caution: Electrostatically sensitive devices (ESD). Devices must exclusively be opened by the manufacturer. Disposal guidelines Packaging can be recycles and should generally be brought to re-use. 4

2 Bus-capable power distribution system SVS16-PN-XX Connection of the SVS16-PN-XX to the EtherNet/IP network is via PROFINET module and the corresponding RJ45 connectors. Every module used in the SVS16 has a 1 bit output/1 bit input. Consequently either 1 byte input/1 byte output for 8 modules or 2 byte input/2 byte output for 16 modules. 2.1. Overview 2.2. Schematic diagram (SVS16-PN-16 shown) load pcb bus pcb PROFINET-DP Slave SVS16-PN-16 + 5 V bus pcb Connection PROFINET RJ45 F1 Line GND SC F2 F15 F16 Line GND SC Line GND SC Line GND SC communication PWR RUN/NS ERR/MS CM CE Load IN+/ PE SO Load IN+/ PE SO Load IN+/ PE SO Load IN+/ PE SO bus pcb communication bus pcb communication bus pcb communication bus pcb communication X1 X2 + + X15 X16 + + + bus pcb - bus pcb configuration switch X21 - - - - 1+ 2+ 1-2- PE DC 24 V / max. 40 A PE PE PE PE X31 DC24V 1+ 2+ 1-2- 5

2.3. Termination 2.3.1. Supply voltage load module Rated voltage DC 24 V (18...32 V) Total current max. 40 A DC 24 V (+) 1+ / 2+ (2-way) DC 24 V (-) 1- / 2- (2-way) PE PE connected to DC 24 V (-) Termination X21 for type SVS16-PN-XX-C13: 5-pole spring-loaded terminals, (1+/2+/1-/2-/PE) cable cross section max. 10 mm 2 for type SVS16-PN-XX-C23: 5-pole spring-loaded terminals, (1+/2+/1-/2-/PE) cable cross section max. 16 mm 2 screw terminals M4 2.3.2. Supply voltage bus module Rated voltage DC 24 V (18...32 V) Current consumption max. 250 ma Termination X31 2-pole push-in terminal (1+/2+) cable cross section max. 1.5 mm 2 2-pole push-in terminal (1-/2-) cable cross section max. 1.5 mm 2 2.3.3. Load outputs Rated voltage DC 24 V (18...32 V) Current consumption Termination max. 10 A per terminal block / slot (L+) protected load output (+) (L-) negative return load (-) (PE) PE X1 X8 (X16) for type SVS16-PN-XX-C13: three-level screwless spring-loaded terminals cable cross section max. 1.5 mm 2 for type SVS16-PN-XX-C23: three-level screw-type terminals cable cross section max. 1.5 mm 2 screw terminals M3 2.3.4. F-slots Slots for the types ESX10-(S)115, ESX10-(S)125 and E-1048-S7xx. SVS16-PN-08... F1...F8 = terminals X1...X8 SVS16-PN-16... F1...F16 = terminals X1...X16 6

2.4. Operating modes The operating modes of the unit are set via a DIP switch as follows: 1 2 3 4 ON OFF Switch Description ON condition OFF condition 1 freeze freeze active, a bus error will not affect the condition of the connected load. 2 firm IP IP address configured firmly on 192.168.0.1 3 admin admin mode active, i.e. DHCP, HICP and possibly web are active 4 (reserve) freeze inactive, a bus error will influence the condition of the connected load, all connected loads will be switched off. IP address configured dynamically (or last active one) All network services except the field bus service are off 2.5. Behaviour in the absence of a bus connection The behaviour of the SVS16-PN in the event of a bus failure (failure of master, interruption of bus line etc.) is determined via the DIP switch 1. The host controller saved the ON/OFF condition in the internal EEPROM. The following phases have to be distinguished during start-up: 1. Switch on supply voltage, no field bus communication yet with the superordinate master. Here the behaviour depends on the DIP switch 1 as follows: a. Freeze active : the switches are activated according to the EEPROM contents, i.e. the status will be set corresponding to the latest status before the supply voltage was switched off b. Freeze inactive : all switches are off. 2. Cyclical master communication active. The master controls the condition of the switches. Changes of the ON/ OFF condition by the master will be stored in the EEPROM of the host controller. 3. Cyclical master communication failed:. a. Freeze active : the switches will be activated according to the EEPROM contents, i.e. they keep the latest state received from the master. b. Freeze inactive : all switches are off. 7

2.6. Addressing 2.6.1. General information and operating modes Assignment of the device address is via the integral MAC addresses in the device. There are three ways how to set IP addresses allowing access to the device: 1. Firm IP address. The firm IP address is activated by switching the DIP switch 2 to On. The following network parameters will then be activated: IP-address 192.168.0.1 netmask 255.255.255.0 gateway 0.0.0.0 2. Admin mode: The admin mode is activated via the DIP switch 3. If the admin mode is active, other services to be reached via the network are also active for parameter selection: DHCP, HICP and web. If the address parameters are changed by means of these services, these will be filed in the non-volatile memory and will remain active even after switching the admin mode off. 3. Fieldbus-specific addressing: this function is permanently active and allows address assignment via the fieldbus-specific mechanism (see below for details). The mode firm IP address can be used for resetting the device to a defined address. When activating the mode Firm IP address and the admin mode at the same time, further configuration settings can be carried out under the firm address 192.168.0.1, even if no other mechanism for address assignment are used. Should the IP address parameters be changed in this condition, the mode Firm IP address has to be selected before a restart. If the mode Firm IP address is inactive, the parameters stored in the non-volatile memory will be valid after start. These parameters can be adjusted via the fieldbus-specific services (e.g. CIP objects) or via the other mechanisms for address adjustment (particularly DHCP, HICP and website). Depending on the DIP switch status the following types of address assignment are possible: Mode Switch 2 (firm IP) Switch 3 (firm IP) Description 0 0 0 address assignment only possible via fieldbus-specific mechanisms if no address is assigned via fieldbus, the most recently used address will remain active. 1 0 1 address assignment possible via fieldbus and all standard mechanisms (see Chapter 2.6.3, e.g. HICP, DHCP, web). if no address is assigned via one of the active protocols, the address most recently used will remain active. 2 1 0 address will firmly be assigned to 192.168.0.1 address assignment via fieldbus-specific mechanisms possibly nevertheless (temporarily), but will be reset upon re-start. 3 1 1 as mode 1, but after starting the device the firm IP 192.168.0.1 will be used. As all other protocols for address assignment are active, the address can be changed temporarily. The condition as delivered is mode 1. In condition 1 the latest adjusted condition will remain active. 8

2.6.2. Fieldbus-specific unit search / address assignment With PROFINET and Ethernet/IP, fieldbus-specific mechanisms are made available for locating devices in the network and for assigning IP addresses. These mechanisms are, independent of the DIP switch positions (switch 2, switch 3), permanently active and work as follows: Fieldbus Device location Address assignment EtherNet/ IP PROFI- NET EtherCAT device location via CIP identity broadcast via DCP protocol any configured device can be located. via the device manager of the TwinCAT software configuration (incl. DHCP on/off) via the CIP object. via DCP protocol, normally automatically when setting up the connection via the device name. via the device manager of the TwinCAT software Modbus-TCP (none) (none) The fieldbus project planning tool (Step 7/TIA Portal for PROFINET, Rockwell RSLinx Software, via Communication RSWho) or the Rockwell Studio 5000 Environment via EtherNet/IP is used for using these fieldbus-specific mechanisms. 2.6.3. Standard functions for address assignment The IP address of the device can be set via the following methods via the network when the admin mode is active (see above): - Via the standard TCP/IP-protocols DHCP/BootP. In this case the module always queries for an IP address during start-up via a network broadcast. Prerequisite: the network holds a DHCP/BootP server. If an address has been received, it will be stored as standard address in the flash and be used later, even if no DHCP/BootP server is available any longer. - Via the HMS-controlled HICP protocol (with the Windows software AnybusIPConfig). Here a broadcast is sent by a PC application so that even modules with faulty network settings can be configured. Pre-condition is the installation of an additional software on the customer PC. If an address has been set above, it will be stored in the flash as standard address and be used with immediate effect. - Via the integral web server (if activated). Note - For safety reasons, unnecessary/unused services should be deactivated. As a standard mechanism for addressing is available in Ethernet/IP, the HICP mode should be deactivated (and equally Telnet/FTP or HTTP if unused). 2.7. Setting of the EtherNet ports Data transmission normally is effected with 10 or 100 Mbit/s in full duplex mode with automatic recognition of MDI/ MDX and 10/100Mbit half/full duplex. 9

2.8. Configuration of SVS16-PN The PROFINET cyclic I/O data are provided in a module with 1-byte I/O (for 8 channel SVS16) or with 2-byte I/O (16 channel SVS16). The GSDML file contains two different devices, depending on the type (SVS16-8 / SVS16-16) ( DAP, with the respective order numbers), each with a fixed configuration slot for I/O. The SVS16-PN-XX provides two each bytes input and output data. This means in detail: Output byte 1 (Control/Reset) slot no. F1 F2 F3 F4 F5 F6 F7 F8 binary value 2^0 2^1 2^2 2^3 2^4 2^5 2^6 2^7 decimal value 1 2 4 8 16 32 64 128 Output byte 2 (Control/Reset) slot no. F9 F10 F11 F12 F13 F14 F15 F16 binary value 2^8 2^9 2^10 2^11 2^12 2^13 2^14 2^15 decimal value 256 512 1024 2048 4096 8192 16384 32768 The word splits itself in two bytes. Each output byte activates 8 slots with the least significant bit (LSB) of the output byte 1 being assigned to the slot F1. The most significant bit (MSB) of the output byte 1 is assigned to slot F8. Analog to the output byte 1 the least significant bit (LSB) of the output byte 2 is assigned to slot F9 and the most significant bit (MSB) to slot F16. Depending on the population of the SVS16 the following has to be determined: a) slot fitted with E-1048-S7xx (with control input and status output) 1 24 V ON switch on E-1048-S7xx 0 24 V OFF switch off E-1048-S7xx b) slot fitted with ESX10-(S)115 (with control input and status output) 1 24 V ON switch on ESX10-(S)115 0 24 V OFF switch off ESX10-(S)115 c) slot fitted with ESX10-(S)125 (with control input and status output) min. 100 ms min. 100 ms For reset an ESX10-(S)125 in OFF condition a pulse of a duration of min. 100 ms. The ESX10-(S)125 cannot explicitly be switched off. 10

Input byte 1 (status) slot no. F1 F2 F3 F4 F5 F6 F7 F8 binary value 2^0 2^1 2^2 2^3 2^4 2^5 2^6 2^7 decimal value 1 2 4 8 16 32 64 128 Input byte 2 (status) slot no. F9 F10 F11 F12 F13 F14 F15 F16 binary value 2^8 2^9 2^10 2^11 2^12 2^13 2^14 2^15 decimal value 256 512 1024 2048 4096 8192 16384 32768 Each input byte allows importing status or failure indications of 8 slots. Assignment of the individual slots is identical with the above described assignment of the output bytes (LSB of output byte 1 is assigned to slot F1, MSB to slot F8 etc.). Independent of the devices types the following determinations are valid: 0 device is ON 1 device is OFF and slot is empty This means that the value 256 will be transferred when no circuit breaker was plugged in. 2.9. LED indication for bus communication (PROFINET) The status of the device and the network will be shown by extern LED s. The LEDs indicate the following information: Network status LED RUN / NS Module status LED ERR / MS Offline off Not Initialized off Online (RUN) green Normal Operation green Online (STOP) one flash in green Diagnostic Event(s) Blink flashing green Expection error red Fatal event red Fatal event red Station Name error IP address error Configuration error one flash in red two short flashes in red three short flashes in red Firmware update one flash in green alternate in red, green 11

2.10. Signalling of the various operating modes The different operating modes of the power distribution system are indicated as follows: Operating mode Signalling of the operating mode LED CM LED CE LED PWR SVS_SYSTEMINIT 1) green red green 1) green red green 1) green red green SVS_ERROR_CRITICAL yellow red green SVS_ERROR_UNCRITICAL yellow blink red green SVS_STANDALONE (FREEZE) yellow OFF green SVS_NORMAL_MODE green OFF green 1) Color change as LED test 2.11. Operating modes of the power distribution system 2.11.1. Operating mode: SYSTEMINIT After applying the supply voltage the module is in the operating mode. During this period no communication is possible. This mode takes a few seconds. Also the switch setting of the hardware switch S1 is determined. Signalling this mode see table signalling of the operating mode. 2.11.2. Operating mode: FREEZE Requirement: DIP switch 1 = ON. The master controls the status of connected devices. Or in process of interruption in the bus connection, the devices are driven in accordance to the EEPROM content. Signalling this mode see table signalling of the operating mode. 2.11.3. Operating mode: UNFREEZE Requirement: DIP switch 1 = OFF. The master controls the status of connected devices. On interruption of the bus, the connected devices are turning off. Signalling this mode see table signalling of the operating mode. 2.11.4. Operating mode: UNIT_ADRESSING Fixed: The IP address is fix configured to address 192.168.0.1. This requires DIP switch 2 = ON and DIP switch 3 = OFF Admin-Mode: This requires DIP switch 2 = ON and DIP switch 3 = ON. If the Amin Mode is active, the IP address parameters are changed by using its services. Then these parameters are stored in the non-volatile memory and remain active even after the Admin Mode is deactivated. Fieldbus Specified Addressing: This function is always active and allows an address mapping via the fieldbus mechanism. 12

3. Firmware of the Anybus version The firmware of the IC module used determines the selection of the GSDML file to be used 13

Bedienungsanleitung/Instruction manual B_SVS16-EN_e_010616 Bestell-Nr. / Ref. number Y31221302 - Index: - Ausgabe / Issue: 01/2016 / Alle Rechte vorbehalten / All rights reserved E-T-A Elektrotechnische Apparate GmbH Industriestraße 2-8. 90518 ALTDORF DEUTSCHLAND Tel. 09187 10-0. Fax 09187 10-397 E-Mail: info@e-t-a.de. www.e-t-a.de