rev mobile device to remotly control your home 2010 Cybrotech Ltd

Similar documents
MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

A1000 GSM ALARM DEVICE

ProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

SMS Commander Manual

UP100-GSM. GSM based intercom and access control. Installation and user manual

GSM communicator GD-06 Allegro Complete manual

UP200-GSM Intercom and access control unit operating on mobile GSM network

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output

GSM-AUTO GSM Controller User manual

MANUAL 3G GATE OPENER

JVA SMS Gateway User Manual

SMS Transceiver V3 User manual

STD Simple Telemetry Application. Owner s Manual

QK-G026 GSM Remote Controller

Comsec Protection Systems

CONTA-ELECTRONICS GSM-PRO

GSM SECURITY AND CONTROL SYSTEM ESIM021

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

ELC2212X user manual

ecoline GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2.0 and higher Document version:

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:

Interactive GSM-control GSM-RELAY PROBYTE OY

Communicative heating controller, Ethernet

GSM REMOTE CONTROL MANUAL Item NO.: LM182 GSM REMOTE CONTROL UNIT

A TECHNICAL INFO A. External GSM AT420 DATE :

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

CONTROL ANYTHING WITH YOUR CELLPHONE. Use your cellphone to remotely monitor and control the following applications with the CELLSWITCH 100

PLEASE READ BEFORE INSTALL. ECGO-GKP Cellular Telephone Entry

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

User Manual Revision 1.02

MSS-UP200-GSM Single Dwelling GSM Intercom Unit. Operation Manual. [Ver /5/2015]

Airtalk I/O Extender

Operating and installation instructions

SOFTWARE VERSION 3.3. CD P/N Rev. C

QK-G031 Temperature GSM Remote Controller

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

GSM HOME SECURITY SYSTEM

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

Poseidon 4002 MANUAL

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH

Peristaltic Cased Tube Pump

HUAWEI FT2260 Home Phone Connect Quick Start

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Installation and user s guide GSM8H - 3G. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

RADIO PAGING - REMOTE CONTROL SYSTEM

CCTR-820 Mini Water-proof GPS Tracker Using Guide

MiR Bluetooth Box. Technical Documentation

DinBox M36 Hardware Description Guide

Cellcop Communicator CP72u-M

8848 GSM FWT (GATEWAY) USER S MANUAL

Tu Sitio de Automatización!

GPRS Pager 3 INSTALATION AND USER MANUAL

GSM AUTO DIALER WITH IR BEAM DETECTOR

1 BUTTON GSM INTERCOM WITH KEYPAD (3G)

Installation advice / help

Intercom User Manual v1.1

PHOENIX CONTACT

M2 OLED Temperature Monitor Instructions PN 1841

SC-688 GSM FWT USER S MANUAL

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,

MANUAL DOOR INTERCOM 3G AUDIO KEYPAD INTERCOM (ACCESS CONTROL SYSTEM) For 200 Apartments. For your protection, read these instructions completely

USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

USER MANUAL Mobeye CM-Guard CM2000

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data

GD-02-DIN Universal GSM communicator and controller

Installation Manual & User Instructions. MultiCom 500

IntesisBox SMS - Mitsubishi Electric air conditioners

GSM TEMPERATURE ALARM DIALLER

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

WAFER GSM-RELAY REMOTE CONTROL UNIT GSM-RELAY MANUAL SHANGHAI WAFER MICROELECTRONICS CO.,LTD.

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

QTech SMS Lite Quick Start Guide

GSM RELAY type GSM R1 ZAS

page A.0240 Full_Product_catalogue_ BM.indb 110

InTimeGo-630 GPS Watch Tracker User Manual

SEL-003. Manual. Wireless GSM alarm with ultra low consumption. No power supply needed!

APP 700 Technical Specification

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

The Packs Infotel. GSM Converter V2. Installation Manual V7

QTech 3G Cellular Modem CM910. Quick Start Guide

InTimeGo-623 Pets GPS Tracker User Manual

1 BUTTON GSM INTERCOM (3G)

ComTroll 120 GLM GSM modem for sending SMS alarms from LineTroll fault Indicators

DOCUMENT NAME DATE VERSION

Voyager Mobile Entry Plus. (VME Plus) Installer Manual

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module

2 INPUTS, 2 OUTPUTS GSM-RELAY. 850/900/1800/1900 MHz. GSMS-SW22T Manual

WT-1010C2 GSM ALARM SYSTEM

A Hardware watchdog and shutdown button

Transcription:

GSM-SA User Manual rev. 1.02 mobile device to remotly control your home 2010 Cybrotech Ltd

Index Index...1 Description...2 Commands...3 Read inputs by message...3 Activate relay by message...3 Activate relay by incoming call...4 Outgoing alarm message...4 Outgoing alarm call...6 Phone authorization...6 Settings and status...7 Applications...8 Call garage to open door for you...8 Activate heating before arriving to cottage...8 Secure your property against burglary...9 Water level monitoring and alarm...9 Specifications...10 Wiring...10 Mounting...10 Master reset...10 1

Description GSM-SA stand-alone modem provides the following functions: activate relay by a call (free of charge, call is denied) activate relay by a message call predefined number when condition is met send alarm message to predefined number when condition is met read analog/binary inputs by a message authorize users and read status by a message Hardware: - internal GSM antenna - connector for external antenna (SMA type), automatic switch - 4 analog/digital inputs, 2 relay outputs Before inserting SIM card, make sure PIN is deactivated. To do so, enter SIM card into your phone, open Settings, Security, PIN code request, and set to off. Turn phone off, remove SIM and put to GSM-1 module. The similar procedure may be used to renew prepaid account. To insert SIM card, use small screwdriver to lift cover, insert card, then gently push cover back until you hear click. When using on remote locations, where GSM signal is weak, it is recommended to use external antenna. If multi-band antenna is not enough, better results may be obtained with directional yagi, lifted few meters on a pole. Look for 12dB gain or more, and take care to find the best orientation. 2

Commands Send command using SMS message (standard text, not multimedia or e-mail). Module will soon send a reply. Multiple commands are separated by space. Read inputs by message ix0, ix1, ix2, ix3 - binary inputs, 0-open, 1-closed iw0, iw1, iw2, iw3 - analog inputs, for 0..10V readout is 0..1023 send: ix0=? ix1=? iw2=? iw3=? reply: ix0=0 ix1=1 iw2=430 iw3=600 Example: Binary and analog inputs share same terminal. Iw0 is open (ix0=0), iw1 is closed (ix1=1). Iw2 voltage is 4.2V, so readout is 4.2V 10V 1023 = 430. Iw3 is open, pull-up drives it to approximately 6V 10V 1023 600. Commands are not case-sensitive, both small and capital letters may be used. Activate relay by message qx0, qx1 - relay outputs, 0-off, 1-on send: qx0=1 reply: qx0=1 ok message received qx0 Relay 0 is now on. qx0b, qx1b - controls external bistable relay, 0-off, 1-on, depending on feedback contact connected to ix0/ix1 send: qx0b=1 reply: qx0b=1 ok message received message received qx0 0.5 seconds bistable Relay 0 is connected to bistable coil, input ix0 to bistable auxilary (feedback) contact. Bistable relay toggles when coil is energized. Suitable bistable relay is Schrack LQ612230. If bistable is off (ix0=0), qx0b=1 will make a pulse on qx0 to turn it on. If bistable is already on (ix0=1), nothing will happen. Likewise, if bistable is on, qx0b=0 will pulse qx0 to turn it off, and output nothing if it is already off. Reply message returns the actual state of ix0 input, therefore actual state of bistable. Pulse length is 500ms, not related to "pulse" setting. 3

qx0p, qx1p - pulse output for a specified time send: qx0p reply: qx0p ok message received qx0 2 seconds Relay is unconditionally activated for 2 seconds. If already set, it will go off after specified time. pulse - pulse length (default is 2) [seconds] send: pulse=10 reply: pulse=10 ok Configure pulse length to 10 seconds. Activate relay by incoming call voicecall - select action to perform when voice call is received (default is no action): 1 qx0=1 2 qx1=1 4 qx0=0 8 qx1=0 16 qx0b=1 32 qx1b=1 64 qx0b=0 128 qx1b=0 256 qx0 pulse 512 qx1 pulse 1024 send status 2048 call back send: voicecall=256 reply: voicecall=256 ok When call is received, relay qx0 will go on for a predefined time (defined by pulse command): call received qx0 2 seconds To perform actions simultaneously, add up numbers (e.g. with voicecall=3, call will activate both qx0 and qx1). Outgoing alarm message Each input may trigger one alarm message. Message is sent when contact is closed, open, or both ways. Similary, analog input may send a message when value exceeds high limit, lo limit, or both. Message is sent to first authorized phone number. Each input act independently of others. Input may trigger both message and outgoing alarm call. To use alarms, you must authorize your phone. If no phone is authorized, module is not able to send a message. 4

smsalarm - select inputs which will trigger an alarm: 1 ix0 close 2 ix1 close 4 ix2 close 8 ix3 close 16 ix0 open 32 ix1 open 64 ix2 open 128 ix3 open 256 iw0 hi limit 512 iw1 hi limit 1024 iw2 hi limit 2048 iw3 hi limit 4096 iw0 lo limit 8192 iw1 lo limit 16384 iw2 lo limit 32768 iw3 lo limit For a combined action, add values together, e.g. 17 will send a message whenever ix0 is changed. iw0lo, iw1lo, iw2lo, iw3lo - alarm low limit, 0..1023 (default is 0) iw0hi, iw1hi, iw2hi, iw3hi - alarm high limit, 0..1023 (default is 1023) Alarm is activated when value is strictly higher or strictly lower (not equal) than limit value. sms0, sms1, sms2, sms3 - alarm content (default is "Alarm 0", "Alarm 1"...) hyst - hysteresis, common for all inputs, for both high and low alarms (default is 100) rearm - after condition is off, time to wait before new activation is possible (default is 600) [seconds] Alarm is deactivated when value returns below limit and hysteresis: Example 1: Configure two alarms, one for pump overload, second for low level warning. Connect pump overload contact (normally open) to ix0. Connect water level measurement (0..10V) to iw1. Configuration word is 1 (ix0 close) + 8192 (iw1 lo limit) = 8193. Alarm limit is 35cm, full scale is 150cm, so value is 35 150 1023 = 239. send: smsalarm=8193 iw1lo=239 sms0="alarm: pump overload" sms1=" Alarm: water low" reply: smsalarm=8193 ok iw1lo=239 ok sms0="alarm: pump overload" ok sms1=" Alarm: water low" ok ix0 send SMS0 alarm: Alarm: pump overload 5

Example 2: To send separate hi and lo messages, wire two inputs together: Configuration word is 256 (iw0 hi limit) + 8192 (iw1 lo limit) = 8448. send: smsalarm=8448 iw0hi=850 iw1lo=5 sms0="alarm: water high" sms1="alarm: water low" reply: smsalarm=8448 ok iw0hi=850 ok iw1lo=5 ok sms0="alarm: water high" ok sms1="alarm: water low" ok alarm: Alarm: water high Outgoing alarm call voicealarm - select inputs which will make a call 1 ix0 close 2 ix1 close 4 ix2 close 8 ix3 close 16 ix0 open 32 ix1 open 64 ix2 open 128 ix3 open 256 iw0 hi limit 512 iw1 hi limit 1024 iw2 hi limit 2048 iw3 hi limit 4096 iw0 lo limit 8192 iw1 lo limit 16384 iw2 lo limit 32768 iw3 lo limit For a combined action, add values together. Limits and hysteresis are common with message alarm. send: voicealarm=15 rearm=300 reply: voicealarm=15 ok rearm=300 ok Any digital input (1+2+4+8) makes a call. Alarm is armed again after rearm period. ix0 make a call First call goes to first authorized phone number. To confirm a call, press "hang up" button. If not confirmed, module will ring for about 30 seconds, then wait, then ring again. Call is repeated 3 times. Still not confirmed, next call will advance to second authorized number, then third, until alarm is confirmed. To use alarm call, you must authorize your phone. If no phone is authorized, module is not able to make a call. Phone authorization Authorization defines phones allowed to send commands. By default, access is allowed for everybody. Once authorized, commands from other phones will be ignored. Authorized phone is recipient for alarm messages. allow - add number to list of authorized numbers send: allow +385912345678 reply: allow +385912345678 ok 6

deny - delete number from list of authorized numbers send: deny +385912345678 reply: deny +385912345678 ok allowcall - authorize next incoming call (call must come within 5 minutes) send: allowcall reply: allowcall +385912345678 ok error: allowcall timeout check - verify if number is authorized send: check +385912345678 reply: check +385912345678 ok error: check +385912345678 unknown phones - show all configured phones send: phones reply: phones=3: +385912345678 +385912222222 +385913333333 If longer then 160 characters (SMS size limit), rest won't be displayed. As with other commands, one SMS may contain multiple requests, e.g. two "allow" and "phones" command. Settings and status confirm - enable or disable confirmation messages (0-don't confirm, 1-confirm, default is 1) send: confirm=1 reply: confirm=1 ok ping - connection check send: ping reply: ping ok status - read status of inputs and outputs, signal strength (0..31), and roaming status (0-domestic, 1-roaming) send: status reply: qx0=0 qx1=0 ix0=0 ix1=1 ix2=0 ix3=0 iw0=600 iw1=0 iw2=430 iw3=600 signal=27 roaming=0 config - check configuration settings send: config reply: confirm=1 pulse=2 voicecall=0 smsalarm=8193 voicealarm=15 iw0lo=0 iw0hi=1023 iw1lo=0 iw1hi=1023 iw2lo=0 iw2hi=1023 iw3lo=0 iw3hi=1023 hist=100 rearm=600 reset - reset all parameters to factory defaults, allow access to everybody send: reset reply: reset ok 7

Applications Call garage to open door for you Knowledge: easy Usefulness: high (you certainly don't need yet another remote controller) Cool factor: high (watch your neighbours turn green) What do you need: garage with motorized door, GSM-SA, SIM card How to connect: connect wires from QX0 and C0 to button which operate door. Polarity doesn't matter. Don't forget to connect 12V power supply. Module configuration: send: voicecall=256 allow +385912345678 enter your mobile phone here Mobile configuration: put GSM-SA on your speed dial. How to use: press speed dial and lay phone down. Door will open in a few seconds. Module will deny your call, so action is free of charge. However, prepaid account will require periodic updates, usually from 6 to 12 months. To update, put SIM card into your phone. Security is high - once configured, nobody will be able to access your module or change configuration. Other ideas: use the same setup to enter your house. Activate heating before arriving to cottage Knowledge: easy Usefulness: high (even higher if temperature falls below zero) Cool factor: high (it's quite uncool to spend weekend in a freezing house) What do you need: heating system with thermostat, GSM-SA, SIM card How to connect: connect wires from QX0 and C0 in series with your thermostate. Polarity doesn't matter. Don't forget 12V power supply. Module configuration: send: allow +385912345678 enter your mobile phone here 8

How to use: send SMS to activate or deactivate heating. send: qx0=1 to activate heating send: qx0=0 to deactivate heating Other ideas: you may equally well connect GSM-SA to control the power supply of heating system. Secure your property against burglary Knowledge: moderate Usefulness: high (hopefully you'll never know how much) Cool factor: low (good alarm system keeps low profile) What do you need: few meters of very thin wire, GSM-SA, SIM card How to connect: run wire accross the area you want to secure, connect to IW0 and C1. Module configuration: send: voicealarm=16 smsalarm=16 sms0="burglar alarm!" allow +385912345678 enter your mobile phone here How to use: make wiring and leave system on. Check status from time to time: send: status Other ideas: Run another wire around your property. Use other inputs to connect PIR sensors. Water level monitoring and alarm Knowledge: expert Usefulness: high (especially for hardly accessible locations) Cool factor: low (but sharply increase with a number of remote stations) What do you need: level sensor with 0..10V output, GSM-SA, SIM card How to connect: connect sensor to analog input. Module configuration: send: smsalarm=4096 iw0lo=245 sms0="tank 1 level too low!" allow +385912345678 enter your mobile phone here How to use: make wiring and leave system on. Check status regulary: send: status Other ideas: If more measurements or control is needed (temperature, flow, touch screen, scada, database), use programmable CyBro-2/GSM-1 system instead. For more details, check http://www.cybrotech.co.uk. 9

Specifications GSM module Antenna Connector External antenna three-band 900/1800/1900MHz internal or external SMA with automatic switch 50ohm nominal Input type digital / analog 0..10V Internal pull-up 6V, 1mA Digital readout 0-open, 1-closed A/D converter 10-bit Analog readout 0..1023 Accuracy 5% FSR at 25 C Output type Load Power supply Power consumption Operating conditions Dimensions relay contact, normally open max. 3A/250V AC or 3A/30V DC, resistive 12V DC (10-16V) 150mA receiving, 200mA transmitting 0..50 C, 0..85% rh non-condensing 36x99x70mm Wiring digital inputs, 12V output output using 230V contactor output using 230V bistable relay Mounting When operating on internal antenna, it is recommended to mount GSM-SA away from other electronic devices. Placing as high as possible will provide a better signal, resulting in more stable communication. Master reset If module is not accessible for any reason, this procedure will reset to default configuration: - remove SIM card - close ix0 and ix1, leave ix2 and ix3 open - power on and wait about 15s, until power led shortly goes off - power off, insert SIM card and continue normal operation Parameters are now set to default values, allow list is empty (access allowed for everybody). 10