Digital electropneumatic Positioner for the integrated mounting on process control valves

Similar documents
Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control Head for the integrated mounting on process valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Pneumatic Control Unit for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Digital electropneumatic positioner

Digital electropneumatic positioner

Control Head for the integrated mounting on process valves

Digital electropneumatic positioner

Digital electropneumatic Positioner for the integrated mounting on process

Digital electropneumatic Positioner SideControl

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Digital electropneumatic Process Controller

Digital electropneumatic positioner SideControl

Control head for decentralized automation of ELEMENT process valves

Pneumatic Control/Feedback

Control head for hygienic process valves

SideControl Positioner

Installation kits for hygienic process valves

LFC Liquid Flow Controller

По вопросам продаж и поддержки обращайтесь:

Fieldbus Gateway Type ME43

Electromotive process valve - 2 way angle-seat shut-off valve

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

Electromotive process valve - 2 way shut-off globe valve

GEMÜ 1235 Electrical position indicator

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

System Control Unit (SCU)

Digital Positioner 8049

Operating pressure (bar) kv factor (m 3 /h) *3)

Flow. Flow. N/en

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Electromotive process valve - 2 way angle-seat control valve

Mass Flow Meter (MFM)

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Temperature Switches

Series 3730 Type Electropneumatic Positioner

Type 8692, Positioner and process controller Positioner und Prozessregler Positionneur et régulateur de process. Quickstart

Series 95000, 2/2 Direct solenoid actuated poppet valve

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

T EN TROVIS Electropneumatic Positioner

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Magnetically Inductive Flowmeter

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

26360, NAMUR. Technical data

Type 8694 Positioner Top Control Basic

Electronic pressure switch with display Model PSD-4

Electrical Position Indicator

AS-Interface I/O Module

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Product data sheet accessories control and regulation Accessories AIRWIN

HERION SERIES Indirect solenoid actuated spool valves

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

21023, 21025, 2/2 Direct solenoid actuated poppet valves

SPCH/ Big bottle blowing block

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Type 8792, Electropneumatic positioner and process controller. Operating Instructions

SRD Z Intelligent Positioner stainless steel (316L)

Series 3730 Electropneumatic Positioner Type

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Double piston cylinder, Series TWC Ø6-32 mm double-acting with magnetic piston cushioning: elastic

Montageanleitung / Operating Instructions Type

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner

Type 8692, Operating Instructions. Bedienungsanleitung Manuel d utilisation. Electropneumatic positioner and process controller

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

GEMÜ 4232 Travel sensor for linear actuators

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Pressure sensors SDE3, with display

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Absolute encoders - modular bus covers

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

80265 series, 3/2 Indirect solenoid actuated poppet valve

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Technical features. 12/ f. N/en

Type 8792, Quickstart. English Deutsch Français

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT

Transcription:

Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive range of additional software functions Internal control air channel Profi bus DPV1 or DeviceNet (option) Type 2301 Globe control valve Type 2300 Angle-seat control valve The compact Positioner Type 8692 is optimised for integrated mounting on the pneumatic actuators in the process valve series Type 23XX/2103 and is specially designed for the requirements of a hygienic process environment. The control air channel is integrated in the actuator without external tubings. The easy handling and the selection of additional software functions are done either on a big graphic display with backlight and keypad or over a PC interface. The Positioner registers the valve position without deterioration through a contact-free, analog position sensor. The control of singleor double-acting actuators is done without internal air consumption. Communication interfaces such as Profibus DPV1 or DeviceNet and analogue as well as binary feedback can also be chosen. Type 2103 Control diaphragm valve Customised adaption Technical data Material Body Cover Sealing PPS, stainless steel PC EPDM Power supply 24 VDC +/- 10% Ripple 10%, no technical direct current! Setpoint setting 0/4 to 20mA and 0 to 5/10 V Output resistance 0/4 to 20 ma: 180 Ω 0 to 5/10 V: 19 k Ω Control medium Dust concentration Particle density Pressure condensation point Oil concentration neutral gases, air DIN ISO 8573-1 Class 5 (<40μm particle size) Class 5 (<10mg/m 3 ) Cass 3 (<-20 C) Class 5 (<25mg/m 3 ) Ambient temperature 0 to +55 C Pilot air ports Push-in connector Ø 6/4 mm, threaded ports G1/8 Supply pressure Low air fl ow rate 0 to 7 bar 1) High air fl ow rate 3 to 7 bar Air input filter Exchangeable (mesh aperture~0.1mm) Actuator system Low air fl ow rate: Ø Actuator 70 / 90 mm High air fl ow rate: Ø Actuator 130 mm Position detection module Contact-free, wear-free Stroke range valve spindle 3 to 28 mm (3 to 45 mm on request) Installation as required, preferably with actuator in upright position Protection class IP 65/67 according to EN 60529 (NEMA4x in preparation) Power consumption < 5 W Electrical connection Multipole connection Cable gland M12, 8-pins or 4-pins 2xM16x1,5 (cable-ø10mm) on terminal screws (1,5 mm 2 ) Profi bus DPV1, DeviceNet Bus communication Protection class 3 according to VDE 0580 Type of protection II 3 G na II B T4 II 3 D td A22 T135 Conformity EMV2004/108/EG Approval CSA (in preparation) 1) The supply pressure has to be 0,5-1 bar above the minimum required pilot pressure for the valve actuator. www.burkert.com p. 1/6

Ordering information for -Control valve systems A complete -Control valve system consists of a Type 8692 and a process valve Type 23XX/2103. The following information is necessary for the selection of a complete control valve: Item no. of the Positioner Type 8692 without process valve, see ordering chart on p. 3 Item no. of the selected process valve Type 23XX/2103 (see separate datasheets, e.g. 2300, 2301 or 2103) Note: control valve system When you click on the orange box "More info." below, you will come to our website for the resp. product where you can download the datasheet. Example of variations of control valves 8692 Positioner Required process valve, example 2301 2300 2103 Complete control valve with required body and port connection Valve system Type 8802-GD-I 2301 + 8692 Valve system Type 8802-YG-I 2300 + 8692 Valve system Type 8802-DF-I 2103 + 8692 p. 2/6

Ordering chart Type 8692 (other versions on request) Ordering chart adapter kit Description Actuator size Control function Item no. Adapter set for Type 23xx / 2103 Ø 70 / 90 mm NC / NO / springless (A / B / I) 665 721 Ordering chart accessories Description Item no. Valve function Communication Electrical connection Analogue feedback Analogue feedback+ 2 binary outputs Initiator Binary input Pilot air ports Item no. Actuator size ø 70 / 90 mm single-acting No Cable gland No No No Yes Push-in connector Ø 6/4 mm 176 621 4-20 ma No No Yes Push-in connector Ø 6/4 mm 179 026 No No No Yes Threaded ports G1/8 185 139 No Multipole No No No Yes Push-in connector Ø 6/4 mm 176 622 4-20 ma No No Yes Push-in connector Ø 6/4 mm 185 164 No Yes No Yes Push-in connector Ø 6/4 mm 185 165 No No Yes Yes Push-in connector Ø 6/4 mm 179 025 Profi bus Multipole No No No No Push-in connector Ø 6/4 mm 179 027 DeviceNet Multipole No No No No Push-in connector Ø 6/4 mm 185 163 Actuator size Ø 130 mm Single-acting No Cable gland No No No Yes Push-in connector Ø 6/4 mm 185 166 4-20 ma No No Yes Push-in connector Ø 6/4 mm 185 169 No No No Yes Threaded ports G1/8 185 167 Multipole No No No Yes Push-in connector Ø 6/4 mm 185 168 4-20 ma No No Yes Push-in connector Ø 6/4 mm 185 170 No Yes No Yes Push-in connector Ø 6/4 mm 185 171 No No Yes Yes Push-in connector Ø 6/4 mm 185 172 Profi bus Multipole No No No No Push-in connector Ø 6/4 mm 185 173 DeviceNet Multipole No No No No Push-in connector Ø 6/4 mm 185 174 Actuator size ø 70 / 90 mm Double-acting No Cable gland No No No Yes Push-in connector Ø 6/4 mm 185 175 4-20 ma No No Yes Push-in connector Ø 6/4 mm 185 178 No No No Yes Threaded ports G1/8 185 176 Multipole No No No Yes Push-in connector Ø 6/4 mm 185 177 4-20 ma No No Yes Push-in connector Ø 6/4 mm 185 179 No No Yes Yes Push-in connector Ø 6/4 mm 185 180 Profi bus Multipole No No No No Push-in connector Ø 6/4 mm 185 181 DeviceNet Multipole No No No No Push-in connector Ø 6/4 mm 185 182 Approvals CSA M12 socket, 8-pins, 2 m assembled cable 919 061 M12 socket, 4-pins, 5 m assembled cable 918 038 Silencer G1/8 780 779 Silencer, push-in connector 902 662 p. 3/6

8692 Positioner Materials 2 1 7 1 Cover PC 2 Body casing Stainless steel 3 Basic body PPS 4 Plug M12 Stainless steel 5 Screws Stainless steel 6 Push-in connector Threaded ports G1/8 7 Sealing EPDM POM/stainless steel Stainless steel 4 5 6 3 Dimensions [mm] Version connection Multipole Version connection cable glands p. 4/6

Connection options Connection Multipole Circular connector M12-8-pins (setpoint) Circular connector M12-4-pins (supply) Circular connector M12-8-pins (setpoint) Pin Configuration 8 Setpoint + (0/4-20 ma / 0-5/10 V) 7 Setpoint GND Circular connector M12-8-pins (in / output signal)* Pin Configuration 6 Analogue feedback + 5 Analogue feedback GND 4 Binary output 1 3 Binary output 2 2 Binary output GND 1 Binary input + * with the option analogue feedback or binary output Circular connector M12-4-pins (supply) Pin Configuration 1 Operating voltages + 24 VDC 3 Operating voltage GND Connection cable glands 1 2 3 4 5 6 7 12 13 14 8 9 10 11 Terminal screws Clamp Configuration 11 Setpoint + (0/4-20 ma / 0-5/10 V) 10 Setpoint GND 14 Operating voltages + 24 VDC 13 Operating voltage GND 12 Binary input + 13 Binary input GND 9* Analogue position feedback + 8* Analogue position feedback GND 5* Binary output 1 6* Binary output GND 7* Binary output 2 * with the option analogue feedback or binary output p. 5/6

Signal flow diagram Position control loop Additional software functions of the Type 8692 Automatic start of the control system Automatic or manual characteristic curves selection Setting of the seal and the maximum stroke threshold respectively Parameterization of the Positioner Limitation of the stroke range Limitation of the manipulating speed Setting of the moving direction Configuration of the binary input Signal range splitting on several controllers Configuration of an analogue or double binary outputs Signal fault detection Safety position Code protection Contrast inversion of the display Language selection Diagnostic functions Schematic diagram of the Type 8692 Without fieldbus interface 1) The operating voltage is supplied with a 3-wire unit independent from the setpoint signal. 2) Alternative options With Profibus DP / DeviceNet 1) The operating voltage is supplied with a 3-wire unit independent from the setpoint signal. To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 0901/2_EU-en_00895097 p. 6/6