UPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller

Similar documents
UPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller

UPDATING THE SYSTEM MANAGER SD Updating the System Manager with Prism 2

UPDATING THE SERVICE TOOL Updating the Service Tool with Prism 2

USB-Link 2 Technical Guide

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

USB-Link 2 Technical Guide

USB-Link Technical Guide

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

CommLink 5 Technical Guide

CommLink IV Technical Guide

Modular Service Tool SD Quick Start Guide

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

Modular System Manager SD Quick Start Guide

Dual Digital Module Technical Guide

IP Module Technical Guide

GPC-XP Controller Technical Guide

IP Module Technical Guide

IP Module Technical Guide

IP Module Technical Guide

CommLink 5 Technical Guide

IP Module Technical Guide

System Manager TS II Technical Guide. Requires System Manager TS II Code: SS9003 Version 1.0 and up DDC Controller Code: SS9001 Version 1.

System Controls Suggested Specification

FACTORY CONTROLS SYSTEM. VAV/CAV Controller Technical Guide

Graphical Interface Technical Guide

Factory Packaged Controls. MODGAS-X Controller Field Technical Guide

PT-Link II LON-3 Technical Guide

FACTORY CONTROLS SYSTEM. MUA II Controller Technical Guide

WCC III Training Guide

Millennium Simplicity Elite Parameter Points and Quirks

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

PT-Link II N2-4 Technical Guide

GPC Plus Controller. General Information & Application Guide

VAV/Zone Controller Actuator Package Technical Guide

VCM-X E-BUS Component & System Wiring Technical Guide

Product Manual SZ2141

Installation and Operation Instructions

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide

Dot Matrix Indicator Programming

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

M1000 INTELLIGENT ZONE CONTROL SYSTEM

VAVBOX Controller Technical Guide

FLASH GUI. User Manual V1.4 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

PROLON INSTALLATION AND START UP GUIDE

ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

SEZ7656R1045B / SEZ7656H1045B

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE

SE7600E Series Application Guide

Description. descriptors, makes set-up and monitoring very user friendly.

BACnet MS/TP Interface User s Guide

CodeLoader. Users Guide. P/N: Rev: OCT04

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

User Manual. Thermo Scientific Orion

INSIGHT Installation Instructions

QUICK START GUIDE FOR FIRMWARE UPGRADE RS232-TO UART INTERFACE BOARD AND SOFTWARE

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

FCU-4 FAN COIL CONTROLLER

MicroTech II Vertical Self-contained Systems Unit Controller

MicroTech II ServiceTools for Applied Air Handling Unit Controllers

SymSYNC TM User s Guide

Submittal Data Sheet intelligent Touch Manager DCM601A71

FCU-4 FAN COIL CONTROLLER

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

Technical Information

Introduction. What is the RTU Open controller?

SE7600E Series Application Guide

TS110 DISPLAY MANUAL Pro Refrigeration, Inc

STOP! Read these instructions before connecting the PR3 to your Computer

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Product Manual SZ2144

SoftTools Suite 7.0. Flowserve Corporation

Graphical Interface Technical Guide

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

Graphical Interface Technical Guide

Economizer Controller Installation Guide

Internet Key Administration

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips.

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

Industrial Serial Device Server

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP

keyestudio Keyestudio MEGA 2560 R3 Board

ETM-2050/ETM-2051 Service Manual

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

PC PROGRAM INSTRUCTIONS FOR CREST and COPPERFIN MODELS

2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

960H H.264 DVR Setup Guide

Flasher PC Application

D8000 SERIES QUICK START GUIDE

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

Instruction Manual CTC-1

Cascade Configuration Tool

Central Controller Operation & Installation Manual

Transcription:

Updating the VCB-X / VCC-X Controller Updating the VCB-X / VCC-X Controller Using Prism 2 Version 4.5.0 and higher The VCB-X and VCC-X Controllers are equipped with the ability to update their software with the use of a computer. You will need the following before you begin: VCB-X or VCC-X Controller in need of an update (powered up) CommLink 5 or USB-Link 2 Computer running Microsoft Windows TM operating system Prism 2 software from www.orioncontrols.com or wattmaster.com/techsupport Latest version of the Controller software (e-mailed from our tech support staff or downloaded from http:// techsupport.wattmaster.com) USB_Silicon_Labs_Setup.zip driver from http:// techsupport.wattmaster.com or from CD-ROM Modular Service Tool DIN communication cable, USB cable, and adapter Follow these simple steps to update your Controller: 1. Apply power to the Controller. Make sure the Controller is in the Unoccupied Mode with the Fan off. 2. Turn on your computer and download the latest Prism 2 software from www.orioncontrols.com or www. wattmaster.com/techsupport. 3. Either download and unzip the VCC-X or VCB-X hex file software from http://techsupport.wattmaster.com, or if you received an e-mail from Tech Support with the file, unzip and save the file to your computer. Record the path and name of the file for later use. Also, print the software sheet provided for future reference. NOTE: You must unzip the file in order for Prism to recognize the hex file. 4. Download and unzip the USB Drivers Files from http:// techsupport.wattmaster.com so that Prism can communicate to the Main Controller. See page 3 for instructions. 5. Plug the DIN communication cable into the Main Controller s communication port and then into the CommLink 5 or USB-Link 2 and then connect the USB-Link 2 or CommLink 5 to the computer s USB port. Make sure the USB-Link 2 and Main Controller are set to High Speed and Stand-Alone. To connect the Main Controller to the CommLink 5, you will need to use the adapter that was supplied with your Service Tool. See Figures 1 & 2, pages 6-7. 6. Open Prism 2 and Login with the User Name admin and password admin. If successful, Administrator Access will appear at the lower right of the Prism program. 7. Click on the <Job-Site> icon. The Job-Sites Window will appear. In the Type of CommLink Dialog Box, select CommLink 5 or USB Link II. 8. In the Job-Sites Window, from the Serial Port drop down list, select the USB to UART Bridge Controller COM port. If you don t know the COM port number or if the number is 10 or higher, follow the directions on pages 4 & 5. 9, From Prism 2 s Communications tab, select Flash Selected Controller. And from the list select Main Controllers. Updating Controllers 1

Updating the VCB-X / VCC-X Controller 10. The Flash Main Controller Window will appear. 11. Step #1: In the Loop and Unit fields, enter 1 for the Loop and enter the address of the Main Controller for the Unit. 12. Step #2: In the HEX File field, type in the path and name of the HEX file you downloaded and/or copied to your hard drive or click the <Select File> button to search for the file. 13 Step #3: Click on the <Program HEX> button. 14. Step #4: If successful, you should see the HEX File Progress bar showing the progress percentage. 15. Step #5: When the Progress Bar reaches 100%, the Main Controller LEDs will start blinking again and be at normal operation. 16. You can verify the correct version of software in the Main Controller LCD display. 17. For optional verification steps, click the <Advanced> button on the Flash Controller toolbar. The following window will display: NOTE: You should notify WattMaster Tech Support prior to using the Optional Verifi cation Steps Window. 2 Updating Controllers

Updating the VCB-X / VCC-X Controller USB Serial Converter and Serial Port Driver Installation 7. Double-click the WattMaster USB Drivers folder and then double-click the USBInstaller.exe program. Then double-click on the file USB Driver Setup.exe. 1. Insert the USB Driver CD-ROM into your CD-ROM drive or download the USB Driver software file from www.techsupport.wattmaster.com. If using the CD- ROM, go to Step 7. If downloading the file, double-click on the link USB Drivers Files. 2. Click <Open> when asked to save or open the file. 8. The following window will pop up: 3. Extract and run (double-click) USB Driver Setup.exe. 4. Once you unzip the file, the WattMaster USB Driver Installation Window will appear. Click <Install>. This will unzip the driver installation files to C:\Temp\ Wattmaster USB Drivers. 9. Click <Begin Install> and the installation program will walk you through the rest of the steps. The program might prompt you to remove old USB drivers from your computer. Click <Yes> if so. Once installation is complete, you will need to reboot your computer to have the new settings take effect. 10. With successful USB driver installation, you can now connect your USB device. 5. Click your <Start> button and then click, <Computer>. 6. Double-click Local Disk (C:). Then double-click the Temp folder. Updating Controllers 3

Updating the VCC-X / VCB-X Controller Finding What COM Port Number the CommLink or USB-Link is Using 5. Click on the plus sign next to Ports to see all of the common ports. 1. Left-click on <Start>, located on the bottom left of the Windows Tool Bar. 2. Select <Control Panel>. 3. Double-click the System Icon. 4. Click the <Hardware> tab and then click the <Device Manager> button. 6. Locate the USB Serial Port (COM#). The COM# in parentheses is the port it is located on. Write this COM port number down. You will need to know this when setting up the Prism software. 7. If the COM port number is 10 or greater, go to Changing the USB COM Port Number on page 5. 4 Updating Controllers

Updating the VCC-X / VCB-X Controller Changing the USB COM Port Number When the CommLink or USB-Link is first plugged in, it will be assigned a COM port number to be used for communicating with the Prism software. If the port number is 10 or greater, it needs to be changed to a value less than 10 to be recognized by Prism. 4. To assign a port number less than 10, click on <Advanced>. The Advanced Settings Window will appear. 1. Click <Start>, click <Control Panel>, click <System>, click the <Hardware> tab, and then click <Device Manager> to get to the Device Manager Window. 2. Click on the plus sign next to Ports to see all of the COM ports. 5. In the COM Port Number drop box, select which COM port you wish to use. Make sure you select a COM port number that is not currently in use (you can see the ports in use in the Device Manager Window). Select a port that is less than 10. NOTE: Windows will assign a port number to every device that has ever been installed on your computer. So if there are no available ports below 10, choose a port number less than 10 for a device listed that you know you are not currently using. 3. Right-click on USB Serial Port (COM#) and select <Properties>. In the Properties Window, select the <Port Settings> tab. 6. Once you select the correct COM port number, click <OK> and close any windows opened in the process of changing the port number. Make note of this number because you will need it for your Prism setup. Updating Controllers 5

STAND ALONE NETWORK UPDATING CONTROLLERS USING PRISM 2 Main Controller With USB-Link 2 Connection Mini-DIN Cable Supplied With USB-Link 2 ALARM VCC-X Controller M UP MENU ENTER DOWN RS-485 COMM LOOP. WIRE R TO R, T TO T SHLD TO SHLD www.aaon.com www.orioncontrols.com VCCX CONTROLLER Orion No.: OE338-26B-VCCX BINARY INPUTS BI1= PROOF OF AIRFLOW BI2 = DIRTY FILTER BI3 = HOOD ON/OFF BI4 = REMOTE OCCUPIED BI5 = REMOTE COOLING BI6 = REMOTE HEATING BI7 = REMOTE DEHUMIDIFICATION BI8 = EMERGENCY SHUTDOWN AAON No.: V42430 RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC MAIN FAN RELAY 2 RELAY 3 RELAY 4 ANALOG INPUTS RELAY 5 AI1 = SPACE TEMPERATURE RELAY 6 AI2 = SPACE SLIDE OFFSET AI3 = SUPPLY AIR TEMPERATURE RELAY 7 AI4 = RETURN AIR TEMPERATURE AI5 = BUILDING PRESSURE RELAY 8 AI6 = SUPPLY AIR TEMP RESET AI7 = OUTDOOR AIR TEMPERATURE RELAY AI8 = PHONE JACK DUCT STATIC COMMON PRESSURE BACNET =T BACNET SHIELD =SH 24 VAC POWER BACNET + =R ONLY WARNING! MAIN SUPPLY FAN VFD = AO1 POLARITY ECONOMIZER ACTUATOR = AO2 MUST BE OBSERVED OR MODULATING HEATING = AO3 THE EXHAUST FAN VFD = AO4 CONTROLLER WILL BE DAMAGED WattMaster Overlay #SW000064 Rev.: 1A GND +24 VAC DUCT E-BUS E-BUS STATIC X2 X2 Connect Mini-DIN Cable End To Mini-DIN Port On USB-Link. USB-Link 2 Computer With Prism 2 Software Installed Communication Speed Switch Must Be Set To High Speed Configuration Switch Must Be Set To Stand Alone Connect Type B Cable End To USB Port On USB-Link 2. USB Cable Supplied With USB-Link 2 Connect Type A Cable End To USB Port On Desktop Or Laptop Computer. NOTE: USB Drivers Supplied With The USB-Link 2 Must Be Installed On Your Computer Before USB-Link 2 Can Be Used. Figure 1: Main Controller With USB-Link 2 Connection (VCC-X Shown) 6 Updating Controllers

Main Controller With CommLink 5 Connection Mini-DIN Cable Supplied With USB-Link 2 VCC-X Controller ALARM M UP MENU ENTER DOWN RS-485 COMM LOOP. WIRE R TO R, T TO T SHLD TO SHLD www.aaon.com www.orioncontrols.com VCCX CONTROLLER Orion No.: OE338-26B-VCCX BINARY INPUTS BI1= PROOF OF AIRFLOW BI2 = DIRTY FILTER BI3 = HOOD ON/OFF BI4 = REMOTE OCCUPIED BI5 = REMOTE COOLING BI6 = REMOTE HEATING BI7 = REMOTE DEHUMIDIFICATION BI8 = EMERGENCY SHUTDOWN AAON No.: V42430 RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC MAIN FAN RELAY 2 RELAY 3 RELAY 4 ANALOG INPUTS RELAY 5 AI1 = SPACE TEMPERATURE RELAY 6 AI2 = SPACE SLIDE OFFSET AI3 = SUPPLY AIR TEMPERATURE RELAY 7 AI4 = RETURN AIR TEMPERATURE AI5 = BUILDING PRESSURE RELAY 8 AI6 = SUPPLY AIR TEMP RESET AI7 = OUTDOOR AIR TEMPERATURE RELAY AI8 = PHONE JACK DUCT STATIC COMMON PRESSURE BACNET =T BACNET SHIELD =SH 24 VAC POWER BACNET + =R ONLY WARNING! MAIN SUPPLY FAN VFD = AO1 POLARITY ECONOMIZER ACTUATOR = AO2 MUST BE OBSERVED OR MODULATING HEATING = AO3 THE EXHAUST FAN VFD = AO4 CONTROLLER WILL BE DAMAGED WattMaster Overlay #SW000064 Rev.: 1A GND +24 VAC DUCT E-BUS E-BUS STATIC X2 X2 Back of CommLink 5 Set Baud Rate Switch To High Connect Mini-DIN Cable End To PL101904 Adapter. PL101904 Adapter Connect to To RS485 Communication Bus On CommLink 5. Computer With Prism 2 Software Installed MULTIPLE SINGLE HIGH LOW R (+) SHLD T(-) GND 24V SERIAL # LOOP BAUD Set Loop Switch To Single Connect Type B Cable End To USB Port On CommLink 5. USB Cable Supplied With CommLink 5. Connect Type A Cable End To USB Port On Desktop Or Laptop Computer. NOTE: USB Drivers Supplied With The CommLink 5 Must Be Installed On Your Computer Before CommLink 5 Can Be Used. Figure 2: Main Controller With CommLink 5 Connection (VCC-X Shown) Updating Controllers 7

Form: OR-VCCXBOOT-TGD-01D Printed in the USA March 2017 All rights reserved. Copyright 2017 WattMaster Controls Inc. 8500 NW River Park Drive Parkville, MO 64152 Phone: 866-918-1100 www.orioncontrols.com Fax (816) 505-1101