GE Measurement & Control. Packaged Systems. Bently Nevada * Asset Condition Monitoring

Similar documents
CTO CSLS CHARM Cabinets

CTO Server and Network Cabinets

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

3500/32M 4-Channel Relay Module

3500/23E Transient Data Interface

ASCO 920 Remote Control (RC) Switches

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

INSTALLATION MANUAL SLI 50 INVERTER

PDI Modular Compact Remote Power Panel

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

3500/65 16-Channel Temperature Monitor

3500/23E Transient Data Interface

Case Expansion Transducer Systems

3500/22M Transient Data Interface Module

SECTION SWITCHBOARDS

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

Installing the Cisco AS5400XM Universal Gateway

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

3500/53 Electronic Overspeed Detection System

1701/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring

SECTION APPENDIX B SFC DOCUMENT SUBMITTAL SCHEDULE

5504 Thermocouple Analog Input Module

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

920 Remote Control (RC) Switches

Electrical Demand Specification (Reference SOP: )

S66 Series Electronic Fan Speed Control

CONTROL PANEL WIRING SPECIFICATIONS

ZC Series Zone Monitoring Controllers

Innovative POWER Solutions

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

3500/77M Recip Cylinder Pressure Monitor

Description. System Event List Alarm Event List All module and channel data Current alarm data (quick view) Nine custom display options.

3500/50E Tachometer Module

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Installation Instructions

E-Series Site Preparation Guide

MACHINE MONITORING SYSTEM SPECIFICATION

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Installation Job Aid for VSP 4850GTS

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Specification Voltage Limiting Device

3500/77M Recip Cylinder Pressure Monitor

Junos WebApp Secure 5.0 Hardware Guide

3500/45E Position Monitor

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Liebert XDA Air Flow Enhancer. User Manual

CENTERLINE 2500 Motor Control Centers

MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes

Installation Job Aid for Ethernet Routing Switch 3600 Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installing the Cisco MDS 9020 Fabric Switch

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Solar Combiner Enclosure

Converter SINAMICS G150. Type 6SL37102G

3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring

Cisco CRS 16-Slot Chassis Power Systems

NI PXI-1042 Series Power Supply Shuttle

3500/15 Power Supply. Description

Energy Storage Systems Utilizing the SunDial Plus 30PV+S Inverter

3500/45 Position Monitor

Operating instructions. Standstill monitor A / / 2011

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Model 7705 Control Module

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

60103 Circuit Breaker

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

MDM 011-Z1 Regen Resistor

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Applying branch circuit breakers and supplementary protectors in North America

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Installation Instructions

PowerFlex 400 AC Drive Guide Specification

, , and and above Rackmount Kits Instructions

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Preparing to Install the VG248

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

Applying branch circuit breakers and supplementary protectors in North America

Trendmaster* Galvanic Isolator

Specifications, Installation, and Operating Instructions

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Avanti HP Series Centrifuges Preinstallation

Transcription:

GE Measurement & Control Packaged Systems Bently Nevada * Asset Condition Monitoring

Complete System Enclosure Packages In about the same time it takes to deliver unconfigured monitoring racks and components, GE s Bently Nevada Asset Condition Monitoring team can deliver a complete packaged system using our standard cabinet designs. Packaged systems address the need for a completely site-ready solution that can be commissioned at site faster and with fewer complications. This is accomplished by performing work at the factory that would normally be done in the field. The enclosed instrumentation is delivered to site configured, integrated, documented, pre-wired, labeled, and tested. The site simply connects field wiring and power using the enclosure s easily accessible, clearly labeled terminals. Customers around the world choose our system Simplicity A packaged system cost-effectively simplifies and streamlines the hundreds of details associated with placing a machinery protection and management system into service. Quality Built to the same rigorous standards of quality as all of GE s Bently Nevada products, attention to detail and craftsmanship permeate every facet of our cabinets. Protection Specifically designed to protect personnel from accidental contact with enclosed electrical instruments and to protect those instruments against specified environmental conditions. Convenience Internal layout permits convenient system installation and wiring, while the exterior is attractively designed to complement your particular installation site. Scope We can install, wire, and commission our cabinets and enclosed instrumentation at your site, in addition to providing a full range of project management, training, and other services.

Flexibility We provide a full range of cabinet designs to best meet our customers needs. We offer a standard off-the-shelf cabinet as well as engineered solutions to address non-standard customer requirements. We can accommodate third-party instrumentation and components in our cabinets. We also can provide customers with cabinets specifically designed and manufactured for installation in hazardous environments. Single-Source Supplier All manufacturing operations and services are coordinated by us, providing greater convenience, simplified communications, a single point of responsibility, less travel to multiple vendors, and time savings. When Factory Acceptance Testing (optional) is specified, we test not just the cabinet, but the installed instrumentation as well. This reduces the installation and testing time required on-site. Extensive Applications Experience We have more than 45 years experience in projects for rotating machinery monitoring systems in diverse applications around the world. Computer-Aided Design/Drafting Clear, highquality drawings offer consistency throughout the documentation package. Electrical Design Power distribution systems are designed to meet the monitoring equipment needs while preventing false trips, missed trips, or fault conditions. Quality Assurance All cabinets are subjected to a battery of standard inspections and tests at our manufacturing centers, assuring system quality and compatibility upon arrival in the field. Field Service We pride ourselves in our service excellence. Product Service and/or Design and Installation Services are available for installing new cabinets in the field, providing turnkey convenience. Training Your needs for system orientation and training can be provided at the factory on your specific hardware, rather than on typical equipment. The result is enhanced familiarity and greater confidence by those who will actually be using the system once commissioned in the field.

Overview: World-class instruments deserve world-class enclosures A variety of display options are available and fully configured upon request. Power and signal wiring are segregated for enhanced protection and reduced susceptibility to measurement interference. Electromagnetic compatibility (CE marking) for customers requiring additional protection of the electrical components and where required in European applications. All cabinets have built-in cooling to prolong instrument life. Monitoring systems are configured at the factory to match customer-specific application details (performed upon request). Certification to CSA and US standards are available for cabinets installed in North American sites. Factory Acceptance Testing (FAT) available for complete system including instrument racks, communications processors, computers, software, and related equipment. The accessibility of all components is ideal for field installation and maintainability. Clearly labeled wire tags. FRONT shown with door closed.

Complete design services are available to fit difficult requirements at a competitive price. Order support provides schedule, single point of contact, expediting, and other services to meet your project plans/schedules. Foreign language support is available upon request. ISO 9001 Certified (North America and Europe locations. Outline dimensions/internal layout/power/field termination/data communication drawings are supplied for easy field installation and maintenance. INSIDE showing panel wiring and convenience outlet. BACK shown with door open.

Standard 1 Equipment and Options NEMA 12 Enclosures Indoor Freestanding 2 The standard features of the IP54/NEMA 12 enclosures are as follows: Includes 100 mm base/plinth (used for bottom cable entry or to meet height requirements for display). Color: RAL7022 (umber gray). Solid front and rear access door with 3-point latches and key locks to prevent unauthorized entry. Outlet filter and inlet fan installed in rear door. Fluorescent lamp with motion detector. Power Termination Blocks 4 Weidmüller WDU 6 (beige) or equivalent. Signal Terminal Blocks 4 Weidmüller WDU 2.5 (beige) or equivalent. Recorder Termination Blocks 4 Weidmüller WDU 2.5 (beige) or equivaalent. Relay Termination Blocks Weidmüller WDU 2.5 (beige) or equivalent. PVC insulated wire for all wiring. Cable guide rings and/or PVC wireway for routing cable. Four removable eye-bolt lifting lugs. Print pocket for documentation storage. Two copper bus bars (earth and signal common). Provision for primary and secondary line power. Options for 120 VAC/60 Hz, 240 VAC/50 Hz, or 125 VDC operation. DIN-mount double-pole circuit breakers supplied for each 3500 power supply and electrical device. Field-cable entry through removable gland plates in bottom of enclosure 6. Ring-tongue type wire lugs are used for connection to bus bars. Screw clamp style terminals are used for all other wiring with ferrules. Duplex power outlet 5. Internal wires are labeled per GE standard conventions. Notes: 1. Custom cabinets and modifications to standard cabinet designs are available upon request. 2. Wallmount style cabinet dimensions vary with installed equipment and applications. 3. Height does not include optional 100 mm base. 4. Knife disconnect terminals provided upon request. 5. Outlet style based on end user location. 6. Bulkhead-mount racks mounted on rear mounting panel.

For every 10 C rise in temperature, component life can decrease by 50%. All our cabinets are designed with appropriate heating and or cooling to meet the environmentalneeds of the installed systems. System Configuration All Bently Nevada monitoring systems included in a Packaged System are configured 1 with project-specific data 2. Typical information required to configure monitoring systems includes the following: Channel Types Full-Scale Ranges Alert and Danger Setpoints Transducer Orientations Circuit breakers open both the neutral and power lines. This eliminates the possibility of shock in the case of high voltage on the neutral line (NEC only requires power line to be broken). Convenience Features Internal enclosure lighting with motion detection. Convenience outlet to power portable equipment during commissioning or during other maintenance periods. Cable entry gland plates and cable clamping options. Equipment Protection Features Standard Ventilation air circulation fans and filters are provided to ensure that adequate and clean cooling is provided for the installed instrumentation. Over-temperature monitoring utilizing internal thermostat with contacts for remote alarming. Relay Logic Configuration Modbus Register Mapping 3 Notes: 1. Configuration software is used to perform system configuration and verify system functionality. 2. If provided by customer. A GE project engineer is assigned to each Packaged Systems order to develop a complete list of required data. 3. This pertains to the interfaces between the monitoring systems and control/automation systems, such as distributed controls systems, turbine controllers, or programmable controllers. Other protocols are supported as well.

Drawings and Documentation A comprehensive drawing package is provided with each enclosure, ensuring that Packaged Systems are fully documented for those responsible for site installation and design, and for those responsible for system maintenance over its entire life cycle. The Standard drawing package includes: Mechanical Layout Rack Front/Rear View (showing individual monitor modules) Internal Wiring Diagrams (including power schematics) Nameplate Schedule Product Operation/Maintenance Manuals for all installed instruments Optional drawings (at additional cost) include: Loop Drawings Documentation is provided in Adobe PDF format.

Lighting and Surge Protection Lightning-caused electrical surge poses significant problems to electronic equipment. Often, a lightning strike has significant financial implications beyond simply damaging the monitoring equipment; it can lead to a false or missed machine trip, impacting your plant s processes. Proper cabinet and system wiring design is essential in protecting your instrumentation from lightning and surges while providing physical protection for the enclosed equipment. Attention must be given to component layout, proper grounding, wiring and component spacing, signal isolation, barriers and surge suppressors, wire routing, and many other details. The best way to ensure the myriad details are properly addressed is to let us supply your complete system enclosure packages. Our design engineers and assemblers have years of experience working with all aspects of cabinets, including comprehensive documentation and labeling for ease-of-installation and maintenance.

Standard Factory Testing Optional Factory Acceptance Testing Standard manufacturing tests, verifications, and quality checks are performed at the factory on every cabinet and installed instrument that we ship, including: All hardware including monitors, monitor options, power supplies, tagging, and other details are inspected and verified against the cabinet Bill of Materials. A point-to-point continuity check of all wiring is performed with the instrumentation unpowered. AC voltage wiring is tested at 1500 VAC for one minute (high-pot) wire-to-wire and wire-to-chassis. Equipment installed in the cabinet is mechanically inspected and power is applied for component functional checks. Optional Factory Acceptance Testing (FAT) refers to extensive system testing performed prior to shipping, in addition to standard factory testing. The FAT is performed on assembled, functioning monitoring systems. Factory Acceptance Testing advantages: Stress Reduction after the hardware order is placed, we will help you gather/define the necessary configuration data work that sometimes gets put off until deadlines loom. Then, we configure the systems to your specifications. Site Readiness there is less to do once the equipment arrives on-site and startup approaches because every FAT includes: Configuration Audit Complete channel-by-channel loop check using stateof-the-art equipment for simulating transducer inputs Timeliness problems are identified sooner and resolved faster. Normally, the customer or their designated inspector is present to witness all FAT-related testing and verification While customer presence is not strictly required (our protocol remains the same regardless), we have found that ßthe FAT is more successful when customers participate directly, allowing face-to-face communication with our engineers. To simplify logistics and reduce delays, the FAT is normally conducted at the same location where manufacturing takes place. Manufacturing/FAT facilities are available in the following global regions: North America: Minden, NV, USA 1,3 South America: Campinas, Brazil Europe: Budapest, Hungary 1,3 Africa/India/Middle East: Manama, Bahrain 2,3 Asia: Singapore 2,3 Notes: 1. ISO 9001 certified facility. 2. ISO certification pending. 3. All locations adhere to comprehensive GE Environmental Health and Safety (EHS) policies and are regularly audited for compliance by company staff.

Packaged System Manufacturing Locations Budapest, Hungary Minden, NV, USA Manama, Bahrain Singapore Campinas, Brazil

Contact GE s Bently Nevada Asset Condition Monitoring team at energy.bnsales@ge.com today for complete product specifications and ordering information. GE Measurement & Control 1631 Bently Parkway South Minden, NV USA 89423 +1 775 782-3611 http://www.ge-mcs.com/bently-nevada * Denotes trademarks of Bently Nevada LLC, a wholly owned subsidiary of the General Electric Company. Adobe is a trademark of Adobe Systems Incorporated AutoCAD is trademark of Autodesk, Inc. Modbus is a trademark of Schneider Automation Inc. Rittal is a trademark of Rittal GmbH & Co. KG Weidmüller is a trademark of Weidmüller Interface GmbH & Co. KG Specifications subject to change without notice. 2014 General Electric Company. All Rights Reserved. GEA17562A (07/14)