KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Similar documents
300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

OPERATOR S MANUAL RKW 300W SERIES POWER SUPPLY SINGLE OUTPUT, UNIVERSAL INPUT SINGLE PHASE, 0.99 POWER FACTOR

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

Voltage Current Front-mounting bracket

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

Industrial Power Supplies

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

OPERATOR S MANUAL HSF 1200W/1500W POWER SUPPLY SINGLE OUTPUT POWER SUPPLIES SINGLE PHASE, POWER FACTOR CORRECTED UNIVERSAL AC INPUT, OPTIONAL METER

CSPS-6K (Shelf Type) POWER you need POWER SHELF

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

OPERATOR S MANUAL HSF A, AM 600 WATTS POWER SUPPLY SINGLE OUTPUT POWER SUPPLIES SINGLE PHASE, POWER FACTOR CORRECTED UNIVERSAL AC INPUT

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

PRM MODEL TABLE. (1) Measured at 115V a-c source.

Output Voltage* (nom.)(adjustable)

SPECIFICATIONS: PSAK650

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

ORDERING INFORMATION SEE PAGE 6

Industrial Power Supplies

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

HEC-100RTN-48QSCA Rev A1.0

Output Voltage* (nom.)(adjustable)

Constant Voltage Mode

H-series (Rectifier Module)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Programmable Power Supply with DALI

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

SPECIFICATION. Model: PS3038. Redundant Power Supply With Active PFC 700W + 700W

Matrix Power Company MG xxx-va+24v series Specification Document

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Environmental. Electrical Specifications at 25 O C E Output Constant Current

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Universal Power Supplies

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Series AMEPR30D-AZ up to 2A AC-DC LED driver

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

60 Watt Medical (MWLT)

PMT. Safety Standards. Model Number:

EMH Series. 250 W & 350 W Forced-cooled. Industry Standard 3 x 5 x 1.43 Format. IT & Medical (BF) Approvals. 80 V VAC Operation

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

Max Output Power Voltage. Convection Forced Convection Forced Nom Peak (2) Model Number (1)

Switch Mode Power Supply S8VT 120/240/480/960 W Models

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

PMT. Safety Standards. Model Number:

NEW! ZERO-UP. Control Flexibility for Worldwide Applications 200W/400W/800W. Built-in RS232 & RS485 Interface with GPIB optional.

MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

Industrial Power Supplies

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Safety Standards. Model Number: Unit Weight:

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

PFE-S SERIES Single Output AC-DC Power Module UL / EN60950 Low Voltage Directive CSA C22.2 No Features Model naming method

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

C1U-W Tx Series

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

RT12-240V/2.4kW Rectifier Specification

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Communications & Networking

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Installation Instructions H Series

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

C1U-W Tx Series AC/DC Front End Power Supply

DDR-120 series. 120W DIN Rail Type DC-DC Converter

C B. Models. Operating up to 5000m altitude 5 year product warranty

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DDR-120 series. 120W DIN Rail Type DC-DC Converter

General. Environmental. EMC & Safety

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Transcription:

146-1915 More than switch mode boxes with wide-range a-c/d-c input power factor correction and current-share capacity... KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE RKW 300W 92 x 80 x 175mm RKW 600W 92 x 120 x 200mm Introducing Kepco s Series RKW Modular Power Supplies. Voltage that you can control. RKW 1500W 92 x 190 x 300mm

ZERO-UP PROGRAMMABILITY IN A POWER MODULE DIN-RAIL MOUNTABLE 1500W, 600W and 300W RKW Models RKW PROGRAMMABLE MODEL TABLE MODEL OUTPUT ADJUSTMENT OVP OUTPUT CURRENT SHORT CIRCUIT SWITCHING NOISE EFFICIENCY (%) RANGE SETTING (1) CURRENT(2) LIMIT CURRENT RIPPLE TYPICAL 300 WATT MODELS Volts Volts -10 to +50 C (3) mv p-p mv p-p (4) 100V a-c 200V a-c RKW 3.3-70K 3.3 1.8-3.6 3.96-4.62 70 73.5-91 90 80 120 68 72 RKW 5-60K 5 3.5-6.0 6.0-7.0 60 63.0-78.0 82 80 120 74 78 RKW 12-27K 12 7.2-14.4 14.4-16.8 27 28.4-35.1 35 120 150 76 80 RKW 15-22K 15 10.5-18.0 18.0-21.0 22 23.1-28.6 29 120 150 77 81 RKW 24-14K 24 16.8-28.8 28.8-33.6 14 14.7-18.2 20 150 200 80 84 RKW 28-12K 28 19.6-33.6 33.6-38.4 12 12.6-15.6 17 150 200 80 84 RKW 48-7K 48 33.6-52.8 50.5-58.0 7 7.4-9.1 11 200 300 81 85 600 WATT MODELS RKW 3.3-150K 3.3 1.8-3.6 3.96-4.62 150 156-186 180 80 120 74 78 RKW 5-120K 5 3.5-6.0 6.0-7.0 120 126-156 160 80 120 76 81 RKW 12-53K 12 7.2-14.4 14.4-16.8 53 55.6-68.9 65 150 200 80 84 RKW 15-43K 15 10.5-18.0 18.0-21.0 43 45.1-55.9 55 150 200 81 85 RKW 24-27K 24 16.8-28.8 28.8-33.6 27 28.3-35.1 35 200 300 82 86 RKW 28-23K 28 19.6-33.6 33.6-38.4 23 24.1-29.8 29 200 300 82 86 RKW 48-13K 48 33.6-52.8 52.8-60.0 13 13.7-16.9 19 300 400 84 87 1500 WATT MODELS RKW 3.3-375K 3.3 1.8-3.6 3.96-4.62 375 390-430 430 100 200 73 77 RKW 5-300K 5 3.5-6.0 6.0-7.0 300 315-350 350 100 200 77 82 RKW 12-125K 12 7.2-14.4 14.4-16.8 125 130-140 152 150 200 80 84 RKW 15-100K 15 10.5-18.0 18.0-21.0 100 105-115 135 150 200 82 86 RKW 24-65K 24 16.8-28.8 28.8-33.6 65 68-72 80 200 300 82 86 RKW 28-55K 28 19.6-33.6 33.6-38.4 55 57.7-63.2 70 200 300 82 86 RKW 48-32K 48 33.6-52.8 52.8-60.0 32 33.6-36.8 45 300 400 84 88 (1) An overvoltage shuts down the output. Recover by resetting the RC terminals. The overvoltage setting tracks the REF voltage. (2) See Figure 1 for ratings vs. temperature. (3) The current limit is rectangular. If overcurrent persists for more than 30 seconds, the output shuts down. Reset by resetting the RC terminals. (4) Bandwidth 100MHz. Ripple and noise will be approximately 1.5 times these values in the operating temperature range -10~0 C. The ripple and noise values tabulated are valid when the output is derated as shown in Figure 1 from 50~65 C. Data subject to change without notice. 2002 KEPCO, INC. Litho in USA

The Programmable-Series RKW are industrialgrade single-output power supplies in the 300, 600 and 1500-watt sizes. They provide d-c outputs from 3.3 volts to 48 volts from a-c mains 85-265V a-c with power factor correction (PFC). They are fully enclosed, fan-cooled power supplies. All models feature overvoltage and overcurrent protection and remote error sensing and feature a remote on-off control, remote voltage trimming and master-slave paralleling with a current balance function. The RKW conform to EN 60950 following the provisions of the Low Voltage Directive 73/23/EEC and 93/68/EEC for the CE mark. Conducted EMI is suppressed to FCC Class B, VCCI Class B, EN 55011-B and EN 55022-B. The 300 and 600 watt models meet the radiated noise limits of FCC Class B and EN 55022 Class B. The RKW 1500 watt models meet the Class A limits for both conducted and radiated EMI, but can be upgraded to Class B with a noise filter, PN 245-0031. Consult factory for details. PROGRAMMABLE POWER 300-1500 WATTS The new Kepco RKW Programmable power supplies are more than high-efficiency switch-mode boxes. Beyond their wide-range a-c (or d-c) input, beyond their power factor correction (PFC) to reduce harmonic corruption of the a-c mains, beyond the current-share capacity that allows multi-unit paralleling, the RKW are fully programmable by either external voltage (0-5V) or by resistance. The output will track the programming signal with remarkable fidelity as the traces below show. Of course, the RKW have large output capacitors so the time constant will depend upon load and at very light loads or no load, the discharge response will be slow. Note particularly the linearity of the RKW power supply's response to square and triangular programming inputs. A 0-5V signal programs the output from 0 to maximum output. A 0-5.5V programming signal will control the RKW to 10% over the rated nominal output. RKW PROGRAMMABLE GENERAL SPECIFICATIONS SPECIFICATION RATING/DESCRIPTION CONDITION Temperature Operating -10 to +50 C See rating curves, Start up -20 to -10 C figure 1 Storage -30 to +75 C Humidity Operating 10 to 95% RH Wet bulb Storage 10 to 95% RH temperature <35 C No condensation Vibration 5-10Hz 10mm amplitude Sweep time 10 min. 10-200Hz 2g 1 hr each axis, not operating Shock Acceleration 30g 1/2 sine pulse 3 shocks each axis, duration 11 ±5 msec not operating Withstand Input-Output a-c 3.0KV 1 min. Cutout current (1) Voltage Input-Ground a-c 2.0KV 1 min. Cutout current (1) Output-Ground a-c 500V 1 min. Cutout current (1) Insulation Input-Output >100MΩ 500V d-c (2) Resistance Input-Ground >100MΩ 500V d-c (2) Output-Ground >100MΩ 500V d-c (2) Safety Standards UL1950 Certified by UL CSA C22.2 No. 950-95 EN 60950 Certified by TÜV (1) Cutout current: 300 and 600W models = 100mA; 1500W models = 300mA. (2) Normal temperature (15-35 C) and humidity (10% -85% RH). RKW FUNCTIONS DESCRIPTION 300W 600W 1500W Overvoltage yes yes yes Overcurrent yes yes yes Thermal Protection yes yes yes PFC yes yes yes Remote On-Off yes yes yes External Voltage Adjust yes yes yes Remote Sense yes yes yes Parallel Operation yes yes yes Master-Slave Operation yes yes yes Series Operation yes yes yes Balance yes yes yes Operation Indicator yes yes yes Power Fail Alarm yes yes yes Fan yes yes yes (two) Output voltage from 0V goes to 52.8V (CH2) Rising Time = 8.50 ms Output voltage from 52.8V goes to 0V (CH2) Falling Time = 9.92 ms RKW Programmable are CE marked per the Low Voltage Directive (LVD), EN 60950.

START UP START UP FIG. 1 OUTPUT POWER VS. AMBIENT TEMPERATURE 300, 600, 1500W Models 100% 88% 80% 70% 60% 40% 20% 10% 100% 92.5% 80% 70% 100% 300W Models 600W Models -20 C -10 C 0 40 C 50 C 1500W Models 3.3V Model 3.3V Model -20 C -10 C 0 40 C 50 C 60 C 56 C 65 C 60 C 65 C RKW PROGRAMMABLE COMMON INPUT CHARACTERISTICS SPECIFICATIONS RATING/DESCRIPTION CONDITION Input Voltage Range Input Frequency Range EMI Conducted Noise (1) Radiated Noise (1) Immunity To Electrostatic Discharge (ESD) Radiated Susceptibility Electrical Fast Transient Surge Withstand Conducted Susceptibility Power Freq Mag Field Voltage Dips, Short Interruptions and Voltage Variations Input Harmonics 85-265V a-c 110-370V d-c (2) 47-66Hz FCC Class B, VCCI-Class B EN 55011-B, EN 55022-B FCC Class B, VCCI-Class B EN 55011-B, EN 55022-B EN 61000-4-2 Level 4 EN 61000-4-3 Level 3 EN 61000-4-4 Level 3 EN 61000-4-5 Level 4 EN 61000-4-6 Level 3 EN 61000-4-8 Level 4 EN 61000-4-11 EN 61000-3-2 0-100% load, -10 to +50 C 0-100% load, -10 to +50 C 300-600W models. 1500W models require noise filter: PN 245-0031 No damage (1) The 300 and 600W RKW meet radiated and conducted FCC Class B and EN 55022 Class B limits. The RKW 1500W models meet radiated and conducted FCC Class A and EN 55022 Class A. The radiated and conducted emissions of the 1500W models are reduced to the Class B level by the use of a noise filter, PN 245-0031. Consult factory. (2) Safety agency approval applies only to a-c input operation. START UP 80% 60% -20 C -10 C 0 40 C 50 C 60 C 65 C RKW Programmable modules can be individually installed or may be combined into a custom power assembly for multi-output requirements. Please see www.kepcopower.com for details on Kepco s Power Assembly Program. RKW PROGRAMMABLE MODEL-SPECIFIC INPUT CHARACTERISTICS SPECIFICATION CONDITION 300W 600W 1500W Input 100-120V a-c 4.4 8.4 22 200-240V a-c 2.2 4.2 11 (5V-48V models) Input 100-120V a-c 3.6 7.2 18 200-240V a-c 1.8 3.6 9 (3.3V models) Surge 120V a-c 20 30 20, typ (1) 240V a-c 40 60 40 Fuse Value 10 15 30 Switching Frequency 200KHz 140KHz 140KHz (2) Leakage 120V a-c 0.24 0.45 0.5 typ (ma) 240V a-c 0.31 0.6 1.1 Leakage 120V a-c 0.3 0.75 0.8 max (ma) 240V a-c 0.38 0.75 1.6 Power 120V a-c 0.99 0.99 0.99 Factor 240V a-c 0.99 0.95 0.95 (1) First surge only, not including the current flow into the EMI filter. (2) Model RKW 3-375K: 100KHz.

RKW PROGRAMMABLE COMMON OUTPUT CHARACTERISTICS SPECIFICATI0NS RATING/DESCRIPTION CONDITION Source Effect typ 0.1% (1) 85-132 or max 0.2% (1) 170-265V a-c Load Effect typ See model specific output ratings 0-100% load Temperature typ 0.5% -10 C to +65 C Effect max 1.0% Combined typ ±0.9% (2) Source, load and Effect max ±1.8% (2) temperature Time Effect typ 0.2% 0.5-8 hours (drift) max 0.5% Transient Excursion ±4% maximum 50-100% load Recovery transient time Characteristic Recovery 1millisecond max >50µsec Start Up 100V a-c See model specific Time output ratings Hold Up 100V a-c See model specific Time output ratings Remote 3.3V models 0.15V Voltage Error 5V models 0.25V compensation Sensing 12-48V models 0.4V per line (1) 3.3V models: 600 and 1500W: 0.15% typ, 0.3% max; 300W: 5mV typ, 10mV max. (2) 3.3V models: 600 and 1500W: ±1.1% typ, ±2.2% max. FEATURES Output indicator, green LED. Remote on-off logic control. Remote error sensing. Parallel operation for redundancy or to increase current. share circuitry to equalize current. Remote voltage trimming by resistance. Remote voltage trimming by voltage. Master-slave operation. Power fail logic signal. Thermal protection. Overvoltage protection. Overcurrent protection. Power factor corrected, wide-range a-c input. DIN-Rail mountable. For information, consult factory. RKW PROGRAMMABLE MODEL-SPECIFIC OUTPUT CHARACTERISTICS SPECIFICATION CONDITION 300W 600W 1500W Load Effect typ 0.2% 0.3% 0.3% max 0.4% (2) 0.6% (1) 0.6% (1) Start Up Time 100V a-c 280 280 280 typ msec 240V a-c 150 100 180 Start Up Time 100V a-c 350 350 500 max msec 240V a-c 210 150 400 Hold Up Time 100V a-c 30 30 35 typ msec 240V a-c 40 40 40 Hold Up Time 100V a-c 20 20 20 min msec 240V a-c 20 20 20 (1) 3.3V models: 0.45% typ, 0.9% max. (2) 3.3V models: 10mV typ, 20mV max. For more information, visit the Kepco website: www.kepcopower.com/ rkw.htm RKW PROGRAMMABLE MECHANICAL SPECIFICATIONS SPECIFICATION 300W 600W 1500W Dimensions Height 3.62" 3.62" 3.62" English Width 3.15" 4.72" 7.48" Length 6.89" 7.87" 11.81" Dimensions Height 92mm 92mm 92mm Metric Width 80mm 120mm 190mm Length 175mm 200mm 300mm Weight English 3.96 lb. 6.6 lb. 13.2 lb. Metric 1.8Kg 3.0Kg 6.0Kg Cooling 1 fan 2 fans Mounting 3 surface

OUTLINE DIMENSIONAL DRAWINGS Fractional dimensions in light face type are in inches, dimensions in bold face type are in millimeters. RKW 300W Models.82 (20.8).67 (17).67 (17) 2.44 (62).48 (12) 2.47.27 (62.7) (6.8) 1.81 (46).48 (12).35 (9).72 (18.23).51 (12.99) 3.62 (92).43 (11) 2.76 ±0.02 (70 ±0.5).43 (11) 1.38 (35) 6.9 (175) 4.7 ±0.02 (120 ±0.5) 8-M4 Mounting Taps.79 (20).75 (19) MAX.55 (14) MAX FRONT VIEW SIDE VIEW TOP VIEW REAR VIEW 3.15 (80) 1.71 (43.5) 1.90 (48.5) 1.57 (40) 1.57 (40) RKW 600W Models RKW 1500W Models.18 (4.5).47 (12) 2.82 (71.7) 18 (.71) 190 (7.48) 87 (3.43) 10 (.40) 43.4 (1.71) 48.8 (1.92) 27 (1.06) 2.17 (55).49 (12.5).75 (19) 1.29 (33) FRONT VIEW 61.8 (2.43) 18.1 (.71) 36 (1.42) FRONT VIEW 76.5 (3.01) 78 (3.07) 92 (3.62) 2.40 ±0.28 (61 ±2).79 (20) 8-M4 Mounting Taps 6.3 ±0.02 (160 ±0.5).79 (20).63 (16) 3.62 (92) 77 ±0.5 (3.03 ±0.02) 8-M4 Mounting Taps 7.5 (.30) 77 ±0.5 (3.03 ±0.02) 7.87 (200) SIDE VIEW 40 (1.57) 300 (11.81) SIDE VIEW 5 (0.2) MAX.85 ±0.28 (21.5 ±2).12 (3) 4-M4 Mounting Taps.4 (10) 40 25 (1.57) (.98) 238 ±0.7 (9.37 ±0.028) 37 (1.46) 10 (.40) 3.27 ±0.28 (83 ±2) 3.94 ±0.02 (100 ±0.5) 4.7 (120) 25 (.98) 115 (4.53) 4-M4 Mounting Taps 170 ±0.5 (6.69 ±0.02) 1.77 (45) 3.94 ±0.02 (100 ±0.5) TOP VIEW 2.44 (62) 2.28 (58) 2.17 (55) 16.6 (.65) 23 (.91) MAX TOP VIEW 10 (.40) 1.71 (43.5) 1.91 (48.5) REAR VIEW REAR VIEW