smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

Similar documents
PRODUCT CATALOGUE 2017

Instrumentation for Industrial Applications

Nokeval. No Manual. Models 575F, 1000F, 1100F, Scalable counter for pulse sensors

Nokeval. Where accuracy counts... Product Summary 2005 for Wireless Transmitters

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

USER MANUAL V1.1. Setpoint unit 2022Setp

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Pen Drive USB Datalogger!

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS

Laurel Electronics Customer Price List

Trident and Trident X2 Digital Process and Temperature Panel Meter

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

C100 Portable Multifunction

LAUREL ELECTRONICS, INC.

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

DMT345 and DMT346 Dewpoint Transmitters

8B SLX300 Data Acquisition System

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

JUMO diraview 104/108/116/132

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

ENVIRONMENTAL MONITORING & CONTROL

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

575F-2051, 575F F-2051, 1000F F-2051, 1800F-2251

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

C160 Wall-/Pipe Mounted Universal Process Indicator

Micro Motion Model 7950 and Model 7951 Signal Converters

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

RS-485 I/O Modules: ADAM-4000

LBVR1718. Description. Features channel paperless recorder

Remote I/O Modules EH-RIO2 Series

MCX II. Druck Portable Documenting Calibrator. GE Sensing. Features. Applications

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

SX90 Process Controller

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

UniPak UP448 Bridge Input Isolating Signal Conditioner

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

Nokeval. No Manual. Model for serial inputs

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Comprehensive Modular Genset Controller

Wall-/Pipe Mounted Universal Process Indicator

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

UNIVERSAL CURRENT CONVERTER

enod4 Weighing controller for automated systems

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

NetBiter I/O Extender User Manual

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

iothinx 4500 Series (45MR) Modules

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

UNIVERSAL TEMPERATURE TRANSMITTER

PRECISION DIGITAL CORPORATION Since 1974 Dual-Line Large Display

PD765 TRIDENT. Trident Series Process & Temperature Meters.

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

ENVIRONMENTAL MONITORING & CONTROL

JUMO Quantum PID100/PID200/PID300

A NEW DATA LOGGER Stand alone. Secure. Fast.

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

iologik 4000 Series (M) Modules

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM100(1402)

MODEL 9250 Preliminary data sheet

Nokeval. FD100 series. User Manual

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Transducers for Pt-100/1000, Resistors

Select a Micro800 Controller

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

KS 3012 PMA GENERAL DESCRIPTION

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Samba PLC+HMI SM35-J-RA22

Z-PC Line REMOTE I/O SYSTEM. Cost-effective & easy to manage TCP-IP

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4114MCM101(1445) For 4511 devices from ser. no:

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Transcription:

2

content DISPLAYS... 4 smart meters... 6 panel meters... 7 field displays... 8 display types... 10 loop powered displays... 12 TRANSMITTERS & CONVERTERS... transmitters... 15 converters... 18 serial data converters... 20 WIRELESS DEVICES... 22 MTR transmitters... 23 MTR receivers... 25 LORA transmitters... 26 base stations... 28 REFERENCES... 30 14 3

4

The keyword for our displays is modularity. In addition to the basic models we offer commutable input and output cards which guarantee changeable features. With these options there is a possibility to fabricate the perfect display for every need. Our displays come in various sizes and casing types. Pick the needed features and add suitable cards. When the criteria changes there s no need to purchase another display, change can be made by changing only the optional cards. Same cards suit to case models 2000, 2800, 575F5, FD100 and FD200. Do you wish your panel meter would do more than just display the readings? Our smart meter models PM10 and PM20 offer immense number of variations for combinations and functions, which takes the measuring to a whole new level. Both models can be freely altered by input and output cards, which makes them the most flexible and cost-efficient panel meters we have. 5

SMART METERS PM10 dimensions 96 X 48 X 115 mm digit size 14.5 mm number of digits 6 digits display color Multicolor LED, red/yellow/green number of inputs/outputs 1-8 inputs ma, mv, V, Ohm, Pt100, Pt1000, thermocouples outputs 4-20 ma, 0-10V. The outputs can follow inputs directly or processing, calculation, terms, thoughts, table linearization, totalization, taring or holding can be added between them. settings By front keys or MekuWin (PC), USB connection serial signal RS485, Modbus RTU, Nokeval SCL protection class Front panel IP65 power supply 24 VDC note Freely definable combinations of inputs and outputs. PM20 dimensions 96 X 96 X 115 mm digit size 14.5 mm number of digits 18 digits display color Multicolor LED, red/yellow/green number of inputs/outputs 1-18 inputs ma, mv, V, Ohm, Pt100, Pt1000, thermocouples outputs 4-20 ma, 0-10V. The outputs can follow inputs directly or processing, calculation, terms, thoughts, table linearization, totalization, taring or holding can be added between them. settings By front keys or MekuWin (PC), USB connection serial signal RS485, Modbus RTU, Nokeval SCL protection class Front panel IP65 power supply 24 VDC note Freely definable combinations of inputs and outputs. 6 MEKUWIN CONFIGURATION SOFTWARE FOR PC MekuWin is a flexible configuration software supporting new and old transmitters. MekuWin loads the structure and the contents of the configuration menu from the target device, so the same MekuWin version can be used with past and forecoming products. MekuWin can be downloaded from our website free of charge.

PANEL METERS PME600, PME610 dimensions 96 X 48 X 70 mm digit size 14.5 mm number of digits 4 digits display color Red LED inputs Thermocouple K: -150...+1200 C RTD: Pt100, -200...+700 C Process inputs: 0...20 ma, 4...20 ma, 0...10 V, -70...+70 mv accuracy 0.05% of span resolution 1 / 32 000, 15 bit settings By front keys alarms Low or high alarm as standard, relays 240 VAC, 3A outputs PME600: 12 VDC 21 ma fixed voltage outage PME610: 4-20 ma, max. 650 Ohm protection class Front panel IP65 power supply Vast supply voltage 24...265 VAC/VDC 2000 SERIES case name 2000 dimensions 96 X 48 X 115 mm digit size 14.5 mm number of digits 6 digits display color Red LED number of inputs/outputs 1 pc, models 2212 and 2251 2 pcs inputs 2000 series inputs (page 10) outputs (optional) 0/4...20 ma, 0...5/10 V settings By front keys alarms (optional) 2...4 relays, 240 VAC, 2A serial data (optional) RS232, RS485, Nokeval SCL protection class Front panel IP65 input voltage for sensor 24 V (10 V) max. 150 ma power supply 85...240 VAC, 12...32 VDC / 24 VAC note Includes 2000-series input card 7

FIELD DISPLAYS 2800 case name 2800 dimensions 180 X 130 X 80 mm digit size 20 mm number of digits 6 digits display color Red LED number of inputs/outputs 1/2 inputs 2000 series inputs (page 10) outputs (optional) 0/4...20 ma, 0...5/10 V settings By front keys alarms (optional) 2...4 relays, 240 VAC, 2A serial data (optional) RS232, RS485, Nokeval SCL protection class 24 VDC, max. 150 ma input voltage for sensor 85...240 VAC, 12...32 VDC / 24 VAC power supply IP65 note Includes 2000-series input card 575F5 case name 575F5 dimensions 310 X 138 X 96 mm digit size 57 mm number of digits 5 digits display color Red LED number of inputs/outputs 1/2 inputs 2000 series inputs (page 10) outputs (optional) 0/4...20 ma, 0...5/10 V settings Keys inside the case alarms (optional) 2...4 relays, 240 VAC, 2A serial data (optional) RS232, RS485, Nokeval SCL protection class 24 VDC, max. 150 ma input voltage for sensor IP65 power supply 85...240 VAC, 12...32 VDC / 24 VAC note Includes 2000-series input card 8

FIELD DISPLAYS FD100 case name FD100 dimensions 4 digits: 477 X 191 X 100 mm 6 digits: 659 X 191 X 100 mm digit size 100 mm number of digits 4/6 digits display color Red LED number of inputs/outputs 1/2 inputs 2000 series inputs (page 10) outputs (optional) 0/4...20 ma, 0...5/10 V settings Keys inside the case alarms (optional) 2...4 relays, 240 VAC, 2A serial data (optional) RS232, RS485, Nokeval SCL protection class IP65 input voltage for sensor 24 VDC, max. 150 ma power supply 85...240 VAC, 12...32 VDC / 24 VAC note Includes 2000-series input card FD200 case name FD200 dimensions 4 digits: 713 X 260 X 120 mm 6 digits: 1013 X 260 X 120 mm digit size 200 mm number of digits 4/6 digits display color Red LED number of inputs/outputs 1/2 inputs 2000 series inputs (page 10) outputs (optional) 0/4...20 ma, 0...5/10 V settings Keys inside the case alarms (optional) 2...4 relays, 240 VAC, 2A serial data (optional) RS232, RS485, Nokeval SCL protection class 24 VDC, max. 150 ma input voltage for sensor IP65 power supply 85...240 VAC, 12...32 VDC / 24 VAC note Includes 2000-series input card 9

DISPLAY TYPES card options for 2000 series optional cards are available for case types 2000, 2800, 575F5, FD100 & FD200 MODEL SENSOR TYPE INPUTS INPUT CARD (SLOT A) ACCURACY RESOLUTION 2012 PROCESS INPUTS ma/v 0/4...20 ma, 0..5/10 V, potentiometer, 100 Ω...10 kω, special input 0...100 VDC by request. 2012-IN 0.05% of span 1/64 000, 16 bit 2212 2 CHANNEL PANEL METER 2 input channels, 0/4...20 ma, 0..5/10 V, potentiometer 2012-IN x 2 0.05% + 1 dig. 1/64 000, 16 bit 2021 TEMPERATURE SENSORS ±0...25/2500 mv, ±0...5/10 V, 0/4...20 ma, Pt100, Pt1000, Ni100, thermocouples K, J, L, T, E, B, N, R, S, C, D, G, Chr-C, resistance 100 Ω...5 kω. 2021-MU 0.02...0.05% of span 1/64 000, 16 bit 2041 STRAIN GAUGE SENSORS Strain gauge 4 X 350 Ω, 4 or 6 wires, input 25...50 mv. 2041-SG 0.05...0.1% of span 1/64 000, 16 bit 2051 FREQUENCY INPUT Namur, NPN/PNP, contact, pick-up. Frequency range 0.0001...5000 Hz. 2051-PU 0.01% of reading 24 VDC, max. 150 ma 2251 RATIO / DIFFERENCE DISPLAY 2 channel display for 2 pulse sensors. Namur, NPN/PNP, contact, pick-up. Frequency range 0.0001...5000 Hz 2061 COUNTER FOR PULSE INPUT Namur, NPN/PNP, contact, pick-up. Frequency range 0...5 khz. Up/ down function by external contact. 2064 INCREMENTAL SENSORS Direction selection by A and B lines from sensors. Frequency range 0...25 khz. 2051-PU x 2 0.01% of reading 2061-CO 2064 2021-MU 2066 TIMER Start, stop and pause by external contact. Time displayed by using dots, e.g. 23.59.59. 2066-CO 30 ppm 2071 SERIAL SIGNAL RS232/485 RS232, RS485, ASCII, Nokeval SCL protocol, Modbus RTU (slave). 2071-IN 2072 10 CHANNEL MASTER DISPLAY 10 display channels for devices with serial RS485 output. Acts as Nokeval SCL master. 2072-IN Please note when placing order, the required power supply(12...32 VDC or 80...260 VAC) must be specified. Order code is formed display type - optional cards - power supply, e.g. 2012-OUT-REL2-230 VAC. Two optional cards can be installed simultaneously, excluding models 2212 & 2251. 10

SENSOR SUPPLY OUTPUT CARD* (SLOT B & C) SPECIAL FUNCTIONS NOTE 24 VDC, max. 150 ma 2000-OUT, 2000-RS, 2000- REL2, 2000-REL3, 2 X REL-2, 2000-I/0 Tare or hold by external contact, special inputs >10V (e.g. input 0-48V) Two 4...20 ma / 0...10 V outputs available. Hold by external contact, 2 input channels First digit displays channel. Inputs are not isolated. 24 VDC, max. 150 ma 2000-OUT, 2000-RS, 2000- REL2, 2000-REL3, 2 X REL-2, 2000-I/0 Min. and max. memory, square root (ma/v input) Optional cards: output, serial and alarm cards can be installed into slot b or C. 2000-OUT, 2000-RS, 2000- REL2, 2000-REL3, 2000-I/0 Hold by external contact 6 wire sensors connection adds measuring accuracy. 24 V (10 V), max. 150 ma 2000-OUT, 2000-RS, 2000- REL2, 2000-REL3, 2000-I/0 Pulse divider 1...64 000 Measuring range starts exceptionally low. 24 VDC, max. 150 ma 2000-OUT, 2000-RS, 2000- REL2, 2000-I/0 2 input channels Typical application: ratio display (%) for two flow meters. 24 VDC, max. 150 ma 2000-RS, 2000-REL2, 2000-I/0 Tare by external contact, 1 week memory May be used as a batch controller (with alarms). 24 VDC, max. 150 ma 2000-RS, 2000-REL2, 2000- REL3 Tare by external contact. Pulse output divider selectable 1...64 000 Movement direction is selected by sensors lines A and B. Tare & start/stop by external contact Time range 99.59.59 (hh.mm.ss). Front keys can be read by serial signal. 2000-OUT The display can read one or multichannel transmitters. *) OUTPUT CARD TYPES 2000-OUT: 0/4...20 ma, 0...5/10V, galvanic isolation 2000-I/0: I/O -card, 4 alarm cards, semiconductor 2000-RS: serial input RS232, RS485 2000-REL2: 1 relay card, 2 relays 2000-REL3: 1 relay card, 3 relays 2 X REL-2: 2 relay card, 4 relays 11

LOOP POWERED DISPLAYS OPERATING POWER FROM INPUT OR OUTPUT LOOP 201, 202 dimensions 96 X 48 X 70 mm digit size 14.5 mm number of digits 4 digits display color Red LED inputs 4...20 ma (loop powered) accuracy 0.05% of span resolution 1/32 000, 15 bit settings By front keys special functions Square root alarms 202: 2 relays, 240 VAC, 150 ma, low or high alarm protection class Front panel IP65 voltage drop 201 max. < 5 V, 202: <7.5 V 301, 302 dimensions 100 X 100 X 57 mm digit size 14.5 mm number of digits 4 digits display color Red LED inputs 4...20 ma (loop powered) accuracy 0.05% of span resolution 1/32 000, 15 bit settings By front keys special functions Square root alarms 302: 2 relays, 240 VAC, 150 ma, low or high alarm protection class IP65 voltage drop 301 max. < 5 V, 302: <7.5 V 202 12

LOOP POWERED DISPLAYS 305 dimensions 80 X 82 X 57 mm digit size 14.5 mm number of digits 4 digits display color Red LED inputs 4...20 ma (loop powered) accuracy 0.05% of span resolution 1/32 000, 15 bit settings By front keys special functions Square root protection class IP65 voltage drop Max. < 5 V 311 dimensions 100 X 100 X 57 mm digit size 14.5 mm number of digits 4 digits display color Red LED inputs Thermocouples: T, K, N, J, J/DIN, E, S, R, B, G, C, D, Pt100, 4...20 ma / 0...10V, 0...100V output 4...20 ma (2-wire) accuracy 0.05% of span resolution 1/64 000, 16 bit galvanic isolation Input isolation >1000V settings By front keys special functions 6 points XY linearization protection class IP65 power supply range 10...32 VDC note 2-wire display may be used w/o current output by connecting 13...24 VDC to output terminal. 311 WITH GALVANIC ISOLATED OUTPUT 4...20 MA Pt100, mv thermocouples 0/4-20 ma 0-15/10V 2-wire output 4-20 ma or power supply 24 VDC 2-wire display takes 8 ma 24 VDC power supply if analog output is not used. 13

14

6420 article 90227 inputs Frequency range 0.00025 Hz...20 khz, NPN/PNP, pickup, push-pull, Namur outputs 0/4...20 ma, 0...5/10 V, pulse divider alarm NPN/PNP programming MekuWin (PC), DCS772 power supply 19...28 VDC accuracy 0.05% of span output load (ma) 650 Ω (24 VDC) output changing time 300 ms operating temperature 0...60 C connectors 2.5 mm2 dimensions 22.5 X 75 X 98 mm note Ramp type output also available. Sensor supply 15 VDC, max. 50 ma. 620S inputs Pt100, 3-wire. Temperature range 100...+650 C, min. range 10 C. Standard ranges -50...+50 C, 0...+50 C, 0...+100 C, 0...+150 C, 0...+200 C. outputs 2-wire 4...20 ma programming Factory settings power supply 10...32 VDC accuracy 0.05% of span output changing time 200 ms operating temperature 0...60 C connectors 2.5 mm2 dimensions 22.5 X 75 X 98 mm note Factory settings for measuring ranges. HTB230 article 61690 inputs Pt100, 2-, 3- or 4-wire, -200...+700 C, range min. 10 C. Ni100, Cu10, 0...2 kω. outputs 2-wire 4...20 ma programming HTBPROG, MekuWin (PC) power supply 6.5...30 VDC accuracy 0.05% of span output load (ma) 870 Ω (24 VDC) operating temperature -40...+85 C connectors 1.5 mm2 dimensions Ø 44 X 22 mm DIN RAIL BRACKET FOR HTB230 MEKUWIN CONFIGURATION SOFTWARE FOR PC TRANSMITTERS RTC685 article 96174 number of channels 1 inputs Thermocouples B, C, D, E, G, J, K, L, N, R, S, Pt100, Ni100, mv ±55 and ±100 mv, 0...40 000 Ω, pyrometer, potentiometer number of outputs 1 outputs 0-20 ma, 4...20 ma, 0-5 V, 0-10 V, Modbus RTU slave -protocol, Nokeval SCL-protocol programming MekuWin (PC) isolation voltage >1,5 kv power supply 24 VDC ±15% accuracy Pt100: 0.05% of rdg +0.25 C TC: 0.05% of rdg +1 C mv: 0.1% of rdg +0.01 mv input resistance 50...80 Ω with ma, >1 MΩ with voltage sampling speed Analog output 125 ms, serial output 20 ms operating temperature -10...+60 C terminals 2.5 mm2 dimensions 22.5 X 100 X 120 mm note A low-cost version of RMC685. 50 samples per second with RS485 serial bus. Mathematical functions. RMC685 article 93863 number of channels 1 inputs Thermocouples B, C, D, E, G, J, K, L, N, R, S, Pt100, Ni100, mv ±55 ja ±100 mv, 0...40 000 Ω, pyrometer, potentiometer number of outputs 1 outputs 0-20 ma, 4...20 ma, 0-5 V, 0-10 V, Modbus RTU slave-protocol, Nokeval SCL-protocol programming Front panel or MekuWin (PC) isolation voltage >1,5 kv power supply 24 VDC ±15% accuracy Pt100: 0.05% of rdg +0.25 C TC: 0.05% of rdg +1 C mv: 0.1% of rdg +0.01 mv input resistance 50...80 Ω with ma, >1 MΩ with voltage sampling speed Analog output 125 ms, serial output 20 ms operating temperature -10...+60 C terminals 2.5 mm2 dimensions 22.5 X 100 X 120 mm note Two rows alphanumerical display for settings. 50 samples per second with RS485 serial bus. Mathematical functions. MekuWin is a flexible configuration software supporting new and old transmitters. MekuWin loads the structure and the contents of the configuration menu from the target device, so the same MekuWin version can be used with past and forecoming products. MekuWin can be downloaded from our website free of charge, 15

TRANSMITTERS 6720 article 13295 inputs Thermocouples: E, J, K, L, T, N, R, S, C, D, B, G Resistance sensors: Pt100, Pt500, Pt1000, Ni100, Res. 0...1000 Ω. ma & mv/v inputs: -100...+100 mv, 0...5 V, 0...10 V, 0...20 ma, 4...20 ma, -20...+20 ma, -10 V...+10 V Infrared sensors: K -type IR-sensor, emissivity settings by MekuWin outputs 2-wire 4...20 ma programming MekuWin (PC) power supply 2-wire 4...20 ma, 10...32 VDC accuracy Pt100: 0.05% of span, TC: 0.1% of span, mv: 0.05% of span current consumption Max. 22 ma input resistance 5 Ω for ma input, 1 MΩ for voltage input operating temperature -10...+60 C terminals 1.5 mm2 dimensions 22.5 X 60 X 75 mm 6740 article 13482 inputs Thermocouples: E, J, K, L, T, N, R, S, C, D, B, G Resistance sensors: Pt100, Pt500, Pt1000, Ni100, Res. 0...1000 Ω. ma & mv/v inputs: -100...+100 mv, 0...5 V, 0...10 V, 0...20 ma, 4...20 ma, -20...+20 ma, -10 V...+10 V Infrared sensors: K -type IR-sensor, emissivity settings by MekuWin outputs 0...20 ma, 4...20 ma, 0...5, 10V programming MekuWin (PC) power supply 24 VDC ±15% accuracy Pt100: 0.05% of span, TC: 0.1% of span, mv: 0.05% of span current consumption 40 ma for ma input input resistance 5 Ω for ma input, 1 MΩ for voltage input operating temperature -10...+60 C terminals 1.5 mm2 dimensions 22.5 X 60 X 75 mm note Suitable for use as galvanic isolators for process signals ma/v 16 7100 article 13422 inputs Thermocouples: E, J, K, L, T, N, R, S, C, D, B, G Resistance sensors: Pt100, Pt500, Pt1000, Ni100, Res. 0...1000 Ω. ma & mv/v inputs: -100...+100 mv, 0...5 V, 0...10 V, 0...20 ma, 4...20 ma, -20...+20 ma, -10 V...+10 V Infrared sensors: K -type IR-sensor, emissivity settings by MekuWin outputs RS485, Nokeval SCL slave programming MekuWin (PC) power supply 24 VDC ±15% accuracy Pt100: 0.05% of span, TC: 0.1% of span, mv: 0.05% of span current consumption 40 ma for ma input input resistance 5 Ω for ma input, 1 MΩ for voltage input operating temperature -10...+60 C terminals 1.5 mm2 dimensions 22.5 X 60 X 75 mm note Suitable for data acquisition software DCS772 DCS772 converter for USB port can be used for configuration of devices that have a socket in the front panel. POL-3PIN adapter cable is sold separately, MekuWin software is available at our website free of charge.

TRANSMITTERS RMD681/RMD680 6821 6841 article 92506/91602 number of channels 8/16 inputs Thermocouples B, C, D, E, G, J, K, L, N, R, S, T, Pt100, Pt1000, Cu10/Cuxxx, KTY 83, 0...400 Ω / 4 kω / 40 kω, ±55, ±100mV number of outputs 1 analog + 1 serial outputs 0/4...20 ma, RS485, Modbus RTU protocol, Nokeval SCL slave protocol programming By front keys or MekuWin (PC) isolation voltage >1 kv power supply 24 VDC ±15% accuracy Pt100: 0.05% of rdg +0.25 C TC: 0.05% of rdg +1 C mv: 0.1% of rdg +0.01 mv input resistance 50 Ω with ma, >1 MΩ with voltage sampling speed 100 ms / channel operating temperature -10...+60 C terminals 1.5 mm2 dimensions 150 X 100 X 60 mm note One of 16 channels can be selected by 4 digital inuts to ma/v output. Serial output is available simultaneously. article 91988 number of channels 2 inputs Thermocouples B, C, D, E, G, J, K, L, N, R, S, T, Pt100, Pt1000, Cu10/Cuxxx, KTY 83, 0...400 Ω / 4 kω / 40 kω, ±55, ±100mV number of outputs 2 outputs 0/4...20 ma, RS485, Modbus RTU protocol, Nokeval SCL slave protocol programming By front keys or MekuWin (PC) isolation voltage >2 kv power supply 24 VDC ±15%, 85...260 VAC accuracy Pt100: 0.05% of rdg +0.25 C TC: 0.05% of rdg +1 C mv: 0.1% of rdg +0.01 mv input resistance 50 Ω with ma, >1 MΩ with voltage sampling speed 100 ms operating temperature -10...+60 C terminals 2.5 mm2 dimensions 45 X 100 X 110 mm note Write own mathematical and logical functions on channels. article 91123 230 VAC; 91260 24VDC number of channels 1 inputs Strain gauge sensors, 4- or 6-wire connection. Measuring range -40...+100 mv. Sensor voltage 10 VDC, max. 150 ma (68 Ω). Includes several weighing sensor calibration methods. May be used together with summing unit 20SA-4. number of outputs 1 outputs 0/4...20 ma, RS485, Modbus RTU protocol, Nokeval SCL protocol programming By front keys or MekuWin (PC) isolation voltage >1 kv power supply 24 VDC ±15%, 85...260 VAC accuracy <0.05% of span sampling speed 250 ms operating temperature -10...+60 C terminals 2.5 mm2 dimensions 45 X 100 X 110 mm note Several ways for sensor calibration: entering mv values, teaching or giving know weighing values. 17

18

CONVERTERS 641 inputs 0/4...20mA, 20...4 ma, 0...5/10 V, 10...0 V ±10 V, 2-wire 4...20 ma, potentiometer, 100Ω...1 mω output 0...20 ma, 4...20 ma, 20...4 ma (reverse), 0...5 V, 0...10 V, 10/5...0 V (reverse) ±10 V, 2-wire 4...20 ma programming DIP switches or factory settings galvanic isolation >1 kv, 3-way isolation power supply 22...30 VDC current consumption 40 ma with V, 60 ma with ma, 80 ma with sensor supply accuracy <0.05% of span input resistance 50 Ω with ma, 1 MΩ with V output load (ma) 600 Ω with ma damping 1, 250, 500, 700 ms operating temperature 0...60 C connectors 2.5 mm2 dimensions 22.5 X 82 X 99 mm note All ranges can be selected by DIP switches, after which calibration is needed. 641-DIP programme for DIP selections available at our website. 6580 inputs 0...20 ma, 4...20 ma, 0...10 V output 2-wire 4...20 ma. Operating energy is taken from output current loop. programming Factory setting galvanic isolation >1 kv power supply 2-wire (10...32 VDC) accuracy <0.05% of span input resistance 50 Ω with ma, 1 MΩ with V output load (ma) 2-wire output damping 100 ms operating temperature 0...60 C connectors 2.5 mm2 dimensions 9.5 X 81 X 58 mm note Loading depens on the power supply voltage, e.g. (24V-10V) 20mA=700 Ω. 6740 article 13482 inputs Temperature sensors, 0...20 ma, -20...+20 ma, 4...20 ma, 0...5 V, 0...10 V, -10...+10 V, 0...10 mv, -100...+100 mv, pot. 0...1 kω output 0...20 ma, 4...20 ma, 0...5 V, 0...10 V programming MekuWin (PC) galvanic isolation >2kV, 3-way isolation power supply 22...30 VDC current consumption 40 ma with V, 60 ma with ma accuracy <0.05% of span input resistance 5 Ω with ma, 1 MΩ with V output load (ma) 600 Ω, with ma damping 200 ms operating temperature -10...+60 C connectors 1.5 mm2 dimensions 22,5 X 60 X 75 mm note All ranges are factory calibrated. 6570B inputs 4...20 ma. Operating energy is taken from input current loop. output 0...20 ma, 4...20 ma, 0...10 V programming Factory settings galvanic isolation >2 kv power supply From input loop current consumption Voltage drop 7 V + output current voltage drop accuracy <0.05% of span input resistance 350 Ω output load (ma) Max. 300 Ω damping 100 ms operating temperature 0...60 C connectors 2.5 mm2 dimensions 22,5 X 60 X 75 mm 19

20

SERIAL BUS CONVERTERS 7470 article 90848 inputs RS232/485 outputs 4 X 0/4...20 ma, 0...10 V baud rate 300...19200 baud galvanic isolation >1kV (RS485) power supply 24 VDC ±15% settings MekuWin (PC) terminals RS232/485 2.5 mm2 installation DIN rail, 35 mm / desktop dimensions 70 X 85 X 60 mm note 4 analog outputs for RS232/485. Modbus RTU, Nokeval SCL protocol or ASCII. Master/slave. Suitable for Vaisala s weather stations. RCS770 article 92620 inputs USB, RS232/485 outputs USB, RS232, RS485 baud rate 1200...115200 baud power supply 9...24 VDC or from USB settings By jumpers terminals RS485 1.5 mm2, RS232 9 pin. D conn. (female), USB/B (female) indicators 3 LEDs installation DIN rail, 35 mm / desktop dimensions 70 X 85 X 60 mm note Conversions: USB-485, USB-422, USB-232, 485-232, 422-232, 485-485 (repeater). USB, 232 and 485 are galvanically isolated. DCS770 article 91872 inputs USB outputs RS485 baud rate 300...115200 baud power supply from USB terminals RS485 1.5 mm2, USB/B (female) indicators 3 LEDs installation Desktop dimensions 31 X 24 X 56 mm note Removable terminals for RS485. DCS772 DCS772 converter for USB port can be used for configuration of devices that have a socket in the front panel. POL-3PIN adapter cable is sold separately, MekuWin software is available at our website free of charge. 21

22

temperature MTR TRANSMITTERS FT10-RT433-IS FT10-RT433-ES FT10-RT433-CS article 94110 inputs Internal Pt100-sensor within the replaceable measuring module operating temperature -30...+60 C accuracy <±0.5 C configuration DCS772 + MekuWin (PC) transmitting interval 5 s...5 min dimensions 60 X 352 X 33 mm protection class IP66 (when connected) note Originally developed for regular calibration demands in coldrooms. Response time 15 min. article 94306 inputs External 4-wire RTD cable sensor connected to the measuring module operating temperature -30...+60 C accuracy <±0.5 C configuration DCS772 + MekuWin (PC) transmitting interval 5 s...5 min dimensions 60 X 374 X 33 mm protection class IP65 (when connected) note Internal terminal block to connect RTD probe or cable sensor. article 94247 inputs External 4-wire RTD cable sensor or M12 probe connected to the measuring module operating temperature -30...+60 C accuracy <±0.5 C configuration DCS772 + MekuWin (PC) transmitting interval 5 s...5 min dimensions 60 X 435 X 33 mm protection class IP65 (when connected) note External M12 connector to connect RTD probe or cable sensor. temperature & humidity FT10-RT433-NSENS-HT-ENS article 98216 inputs Internal Pt100 sensor, external humidity sensor operating temperature -20...+60 C humidity range 0...100% Rh non-condensing accuracy Temperature: 0...+70 C typically ±0.1 C; -20...+80 C typically ±0.2 C Humidity: 15...30 C typically ±0.5% Rh 0...50 C typically ±0.8% Rh -20...+80 C typically ±2.5% Rh configuration DCS772 + MekuWin (PC) transmitting interval 5 s...5 min dimensions 60 X 392 X 33 mm protection class IP40 (when connected) FT10-RT433-RHT article 95411 inputs Internal Pt100 sensor, external humidity sensor operating temperature -30...+60 C humidity range 0...100% Rh non-condensing accuracy Temperature: <±0.5 C Humidity: ±5% of span configuration DCS772 + MekuWin (PC) transmitting interval 5 s...5 min dimensions 60 X 392 X 33 mm protection class IP40 (when connected) note Sintered filter. Other types available as an option. 23

MTR TRANSMITTERS MTR265B article 95858 number of channels 1 inputs Pt100, thermocouples K, J, T, E, L, N. sensor connection External sensor in M12 operating range -30...+70 C accuracy <±0.2 C with Pt100, <±0.75 C or <±1.5 C TC transmitting interval 5 s...5 min programming MekuWin (PC) + DCS772 + POL 3-pin dimensions 172 X Ø 29 mm protection class IP65 note Wall mounting bracket is included. FTR262 article 93212 number of channels 1 inputs Pt100, thermocouples K, J, T, E, L, N, 0...2000 mv, 0...10 V, 0...100 V, 0/4...20 ma sensor connection Screw terminal 1,5 mm2 operating range -30...+60 C accuracy ±0.2 C with Pt100, ±0.75 C or ±1.5 C TC transmitting interval 5 s...5 min programming MekuWin (PC) + DCS772 + POL 3-pin dimensions 80 X 130 X 60 mm protection class IP65 note Sensor type is easy to change by configuration software MekuWin. Battery or external power supply selectable by jumper. FTR264 article 96985 number of channels 4 inputs Thermocouples B, C, D, E, G, J, K, L, N, R, S, T, -30...2000 mv sensor connection Screw terminal 1,5 mm2 operating range -30...+60 C accuracy 0.05% of rdg +0.01 mv 0.05% of rdg +0.6 C + lin. transmitting interval 5 s...5 min programming MekuWin (PC) + DCS772 + POL 3-pin dimensions 102 X 135 X 35 mm protection class IP65 note Also available model FTR264-TCK for variable circumstances, e.g. for measuring concrete structures. MTR262 article 91789 number of channels 1 inputs Pt100, thermocouples K, J, T, E, L, N, 0...2000 mv, 0...10 V, 0...100 V, 0/4...20 ma sensor connection Screw terminal 1,5 mm2 operating range 0...+60 C accuracy ±0.2 C with Pt100 ±0.75 C or ±1.5 C TC transmitting interval 5 s...5 min programming MekuWin (PC) + DCS772 + POL 3-pin dimensions 78 X 45 X 18 mm protection class IP20 note Field enclosure to IP65 as an option. No thermocouple linearization. Measurement result in mv + cold junction temperature. MTR264 article 92191 number of channels 4 inputs Thermocouples K, J, T, E, L, N, 0...2000 mv sensor connection Screw terminal 1,5 mm2 operating range 0...+60 C accuracy ±0.75 C or ±1.5 C transmitting interval 5 s...5 min programming MekuWin (PC) + DCS772 + POL 3-pin dimensions 78 X 45 X 18 mm protection class IP20 note Field enclosure to IP65 as an option. No thermocouple linearization. Measurement result in mv + cold junction temperature. 24

MTR RECEIVERS FT20-RTC433-RECEIVER / FT20-RTC433-REPEATER article receiver 94701; repeater 95328 number of channels up to 100 channels data processing Receiver: PLC serial data / output RS232, RS485 operating range -30...+60 C settings MekuWin (PC) + DCS772 power supply 8...30 VDC dimensions 60 X 352 X 33 mm protection class IP66 (when connected) note Data processing by PLC with FT20- RTC433-receiver. FT20-RTC433-repeater is used for radio range extension. FTR970B, FTR970B-PRO article FTR970B 93005; FTR970B-PRO 92935 number of channels FTR970B-PRO: up to 90 channels non-volatile memory FTR970B-PRO: 150 000 samples data processing PLC serial data / output RS232, RS485, USB protocol Nokeval SCL slave, Modbus RTU operating range -30...+60 C settings MekuWin (PC) power supply 8...30 VDC dimensions 70 X 130 X 60 mm protection class IP65 note Data processing by PLC. The PROversion operated independently without real time data processing in PC. RTR970B, RTR970B-PRO article RTR970B 92415; RTR970B-PRO 92695 number of channels RTR970-PRO: up to 90 channels non-volatile memory RTR970B-PRO: 150 000 samples data processing PLC serial data / output RS232, RS485, USB protocol Nokeval SCL slave, Modbus RTU operating range -30...+60 C settings MekuWin (PC) power supply 8...30 VDC dimensions 70 X 85 X 60 mm protection class IP20 note Data processing by PLC. The PRO-version operated independently without real time data processing in PC. 25

26

temperature LORA TRANSMITTERS FLEX-SKY-T FLEX-SKY-ES FLEX-SKY-CS article 98218 input Internal Pt100 sensor within the replaceable measuring module. operating range -30...+60 C accuracy <±0.5 C settings DCS772 + MekuWin (PC transmitting interval 5 min dimensions 60 X 352 X 33 mm protection class IP66 (when connected) note Developed for regular calibration demands in cold rooms. Response time 15 min. article 98219 input External 4-wire RTD cable sensor connected to the measuring module. operating range -30...+60 C accuracy <±0.5 C settings DCS772 + MekuWin (PC) transmitting interval 5 min dimensions 60 X 374 X 33 mm protection class IP65 (when connected) article 98220 input External 4-wire RTD cable sensor connected to the measuring module. operating range -30...+60 C accuracy <±0.5 C settings DCS772 + MekuWin (PC transmitting interval 5 min dimensions 60 X 435 X 33 mm protection class IP65 (when connected) temperature & humidity FLEX-SKY-NSENS-HT-ENS article 98223 input Internal Pt100 sensor and external resistive humidity sensor operating range -20...+60 C humidity range 0...100% Rh non-condensing accuracy Temperature: 0...+70 C typically ±0.1K, -20...+80 C typically ±0.2K Humidity: 15...30 C typically ±0.5% Rh 0...50 C typically ±0.8% Rh -20...+80 C typically ±2.5% Rh settings DCS772 + MekuWin (PC) transmitting interval 5 min dimensions 60 X 392 X 33 mm protection class IP40 (when connected) FLEX-SKY-RHT article 98221 input Internal Pt100 sensor and external capacitive humidity sensor operating range -30...+60 C humidity range 0...100% Rh non-condensing accuracy Temperature: -30...+50 C <±0.5 C Humidity: 0...+50 C ±5% settings DCS772 + MekuWin (PC) transmitting interval 5 min dimensions 60 X 392 X 33 mm protection class IP40 (when connected) note Sintered filter, other types available as an option. 27

28

29

30

OUR CUSTOMERS 31

Nokeval Oy Rounionkatu 107 37150 Nokia +358 3 3424 810 sales@nokeval.com www.nokeval.com