SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

Similar documents
4-20 ma Analog Input Module HE800ADC020 / HE800ADC120 HE-ADC020* / HE-ADC120* 12-Bit Resolution * HE-denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE-ADC920* 12-Bit Resolution * HE- denotes plastic case.

4-20mA Analog Output Module HE800DAC002 / HE800DAC102 HE-DAC002* / HE-DAC102* 14-Bit Resolution * HE- denotes plastic case.

Thermocouple / Millivolt Input Module HE800THM000 / HE800THM100 HE-THM000 / HE-THM100* * HE- denotes plastic case.

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE820ADC920* 12-Bit Resolution * HE820 denotes plastic case.

RTD Input Module HE800RTD000 / HE800RTD100 HE-RTD000 / HE-RTD100* * HE- denotes plastic case.

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

AC Input /AC Output. Module

MAN October 2010 PAGE 1 HE-579ACM300 SmartBlock Power and Energy Monitor HE-579ACM300

P3-SCM. General Specifications

MAN MAY 2003 PAGE 1 OCX VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out ±10V, ±20mA Analog In/Out HE500OCX404 / HE500RCX404

General Specifications. P2-SCM Serial Communications

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

RS485 MODBUS Module 8I8O

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

QX751 CANOpen HEQX751C203/HEQX751C205 HE-BP41/HE-BP43 Back Pack Module

H704-42(H)(E), H704-42/1(H)(E)

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

RS 485 Mini Modbus 1AO

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

T1K MODBUS Base Controller Specifications

RS485 MODBUS Module 8AO

Ocean Controls KTA-224 Modbus IO Module

KTA-250 Anemometer Alarm Card

RS485 MODBUS Module 8I8RO

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Serial Communication Converters & Adapters Instruction Manual

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

RS485 MODBUS Module 6RO

XL7 OCS Datasheet for HE-XW1E0, HE-XW1E2, HE-XW1E3, HE-XW1E4, HE-XW1E5 HEXT391C100, HEXT391C112, HEXT391C113, HEXT391C114, HEXT391C115

Specifications / Installation. QX Series Models:

GE Fanuc IC695CMM004. Rx3i PacSystem

PACSystems* RX3i IC695CMM002 and IC695CMM004

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

PACSystems* RX3i IC695CMM002 and IC695CMM004

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

Warranty. Warning. Copyright. Contact Us

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

Specifications / Installation. Specifications Digital DC Inputs XL103 XL104 Digital DC Outputs XL103 XL104

XL4 OCS DATASHEET MODEL DC In, 12 DC Out, 2 12-bit Analog In. Serial Ports. USB mini-b USB A. CAN Port Isolated 1 kv.

SmartRail I/O Ethernet Base HE599ETX300

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Table 1 Specifications Software Required for Configuration

Carbon Monoxide Sensor - ModBus

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

ASTAT XB/XBm Remote Operator

RS485 MODBUS Module 16I-M

Chapter 1. Introduction. Additional Documentation

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Installing the Panel. Installing the Panel

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

CAN Fiber Optic Modem

Bulletin 2707 DTAM Plus Operator Interface Product Data

NetBiter I/O Extender User Manual

BARIX X8. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications. Version: 2.01.

ABB LVP&S Training AC500 to EMAX Modbus RTU ABB Automation Technologies

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

Installation Requirements for Conformance to Standards

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

User Manual for XL-J1939

HRM-0800 Instruction Manual

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

GW-7228 J1939/Modbus RTU Slave Gateway

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

SK CU4-CAO Part number:

GE Fanuc Automation Programmable Control Products. PACSystems RX3i. Serial Communications Modules. User s Manual, GFK-2460A.

HE-XE102, HE-XE103/ HE-XE104, HE-XE105

Moxa TCC-100 Series User s Guide

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Getting Started with your D3000M Series Module

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

Product Specification for SAB-S-MODBUS

MRUC-20 Modul-R CAN Bus Network

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

XL4 OCS Datasheet for HE-XC1E0, HE-XC1E2, HE-XC1E3, HE-XC1E4, HE-XC1E5 HEXT251C100, HEXT251C112, HEXT251C113, HEXT251C114, HEXT251C115

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

DI-904MB/DI-905MB/DI-906MB

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

NF760 Batch Controller

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

SRT2-ROC08, SRT2-ROC16

Trident and Trident X2 Digital Process and Temperature Panel Meter

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Transcription:

MAN0842-02 DIM610 PAGE 1 of 6 SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic 1 SPECIFICATIONS Number of Channels Input Ranges DIM610 12 PLC Update Rate 12/24 VDC Terminal Type DIM610 Determined by Communications w/ocs Screw Type, Removable OFF Point 0-3VDC Storage Temp. -40 to 85 Celsius ON Point 10-30VDC Operating Temp. Relative Humidity Input Impedence 4.7Kohm Dimensions WxHxD External Power Supply Voltage Required Power (Steady State) Required Power (Inrush) Isolation -10 to 60 Celsius 5 to 95% Non-condensing 17.5mm x 100mm x 120mm 0.69 x 3.94 x 4.72 10-30Vdc Weight 150g (6 oz.) 35mA @ 24Vdc, typical Negligible 2000Vac for 60 seconds (Input/Power & Input/Comms) Communications Default Comms. Parameters Supported Modbus Commands Modbus/RTU (binary) RS-485 half duplex 38400 baud, N, 8, 1, no h/s Default Modbus ID 1 1,2,3,4,5,6,8,15,16 CE & UL Compliance See Compliance Table at http://www.heapg.com/support/compliance.htm Dimensions in inches are 0.69 W x 3.95 H x 4.72 D Note: Number of I/O terminal connections vary from model to model

PAGE 2 of 6 DIM610 MAN0842-02 2 WIRING I/O - + 12/24VDC 1 2 3 4 5 6 7 8 9 IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 COM I/O RS-485 DC IN Pin # DIM610 1 INPUT 0 2 INPUT 1 3 INPUT 2 4 INPUT 3 5 INPUT 4 6 INPUT 5 7 INPUT 6 8 INPUT 7 9 INPUT COMMON 1 - + 12/24VDC 11 12 13 14 15 IN 8 IN 9 IN 10 IN 11 COM 11 INPUT 8 12 INPUT 9 13 INPUT 10 14 INPUT 11 15 INPUT COMMON 2 INPUTS 0-7 & 8-11 are isolated from each other WIRING RS-485 WIRING DC IN D- D+ GND A B C V- V+ I J 10-30Vdc INIT D Notes: Both ends of the RS-485 network should be terminated with a 100ohm, 1/4W, 1% resistor. Many OCS controllers feature dip switches or jumpers which enable appropriate termination if the OCS is located on a network end.. Init Default Setup: 1. Install jumper between INIT and GND terminals of the RS-485 port. 2. Apply power to Smartmod unit. 3. Read parameter words to see current parameters. 4. Write changes if necessary. D- A D+ B GND C INIT D

MAN0842-02 DIM610 PAGE 3 of 6 The INIT Default RS485 Settings Are: Modbus ID = 1 Baud rate = 9600 Parity = None Stop Bits = 1 3 CONFIGURATION DATA SmartMod Configuration settings are mapped into Modbus Register space. This configuration data may be modified with any Modbus/RTU Master device. For convenience, Horner APG has developed a variety of Cscape application files which allow an OCS (Xle, NX, LX, QX) to act as a SmartMod configurator. Initial configuration of SmartMod module should be done on an individual basis, since all modules come from the factory with a default Modbus ID of 1. Once each module on the network has its own unique Modbus ID, further configuration adjustments can be made with the entire network powered. All configuration parameters listed below are stored in EPROM. That means they should not be constantly rewritten. Configuration Parameters Registers 40001 through 40014 Modbus Register Description Min Max Default 40001-40005 Reserved 40006 Communications Parameters See Table 38.4kbaud, N, 8, 1, RTU Mode 40007 Modbus ID 1 255 1 40008 Rx/Tx Delay (2mS steps) 0 255 0mS 40009 Watchdog Timer (0.5s steps) 0 255 10 (5s) 40010 Watchdog Data I/O Watchdog Data See Table Below 40011 Input Data I/O Data See Table Below 40012-40014 Reserved Register 40006 (Communications Parameters) Bit Definition Bits 7-15 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Unused Mode Parity Data Bits Baud Rate Value Meaning Value Meaning 0 = ASCII 0 = 7 Data 0 Mark 0 1200 baud Mode Bits 1 Even 1 2400 baud 1 = RTU Mode 2 Odd 2 4800 baud 1 = 8 Data 3 Space 3 9600 baud Bits 4 19200 baud 5-7 38400 baud Register 40010 (Watchdog Coils Mirror) Bit Definition Bit 11-15 Bit 10 Bit 9 Bit 8 Bit 0-7 Power-up Event Watchdog Event Watchdog Enable Unused 0 = No Event 0 = No Event 0 = Not Enabled Unused 1 = Event Ocurred 1 = Event Ocurred 1 = Enabled Register 40011 (Input Coil Mirror) Bit Definition Bit Bit Bit Bit Bit Bit Bit 9 Bit 8 Bit 4-7 Bit 3 Bit 2 Bit 1 Bit 0 15 14 13 12 11 10 IN 7 IN 6 IN 5 IN 4 IN 3 IN 2 IN 1 IN 0 reserved IN 11 IN 10 IN 9 IN 8

PAGE 4 of 6 DIM610 MAN0842-02 4 INPUT / OUTPUT DATA SmartMod Digital I/O utilizes both Modbus Registers (40001-40014) and Coils (1-28). It is possible to access all data using Registers only, because the Coils can be accessed through Register 40010-40011. The following tables lists all Modbus I/O data available. I/O Register Data (Registers 40014-40022) Modbus Register Description Access Notes 40010 Mirror of Watchdog Coils Read/Write See Chart in Section 3 (Register 40010) 40011 Mirror of Digital Input Coils Read-only See Chart in Section 3 (Register 40011) 40012-40014 Reserved Modbus Coil Description Access 00001 Watchdog Enabled Read/Write 00002 Watchdog Event Read/Write 00003 Power-up Event Read/Write 00017 Digital Input 0 Read-only 00018 Digital Input 1 Read-only 00019 Digital Input 2 Read-only 00020 Digital Input 3 Read-only 00021 Digital Input 4 Read-only 00022 Digital Input 5 Read-only 00023 Digital Input 6 Read-only 00024 Digital Input 7 Read-only 00025 Digital Input 8 Read-only 00026 Digital Input 9 Read-only 00027 Digital Input 10 Read-only 00028 Digital Input 11 Read-only Watchdog Event & Power-up Event Operation If Coil 1 (Watchdog Enabled) is set, Coil 2 (Watchdog Event) will set if the Watchdog Timeout value is exceeded. The Watchdog Timeout value is set in Register 40009. When set, Coil 2 can be reset by the controller when normal communications resumes. The Power-up Event (Coil 3) is set every time the power is applied. It can be cleared by the controller if desired.

MAN0842-02 DIM610 PAGE 5 of 6 5 INSTALLATION / SAFETY Warning: Remove power from the OCS controller, CAN port, and any peripheral equipment connected to this local system before adding or replacing this or any module. a. All applicable codes and standards should be followed in the installation of this product. b. Shielded, twisted-pair wiring should be used for best performance. c. Shields may be terminated at the module terminal strip. d. In severe applications, shields should be tied directly to the ground block within the panel. e. Use the following wire type or equivalent: Belden 8441. For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances, refer to the hardware manual of the controller you are using. (See the Additional References section in this document.) When found on the product, the following symbols specify: Warning: Consult user documentation. Warning: Electrical Shock Hazard. 6 TECHNICAL SUPPORT For assistance and manual up-dates, contact Technical Support at the following locations: Helpdesk: http://www.horner-apg.com/helpdesk North America: (317) 916-4274 www.heapg.com Europe: (+) 353-21-4321-266 www.horner-apg.com

PAGE 6 of 6 DIM610 MAN0842-02 NOTES