FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

Similar documents
Network Control Engine Catalog Page

LN Series Remote Input/Output (I/O) Modules

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

FX-DIS Local Controller Display Technical Bulletin

Medium User Interface (MUI) Version 3

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

Application and Data Server (ADS) Lite-A System Catalog Page

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3, MS-NAE5510-2U

FX Input/Output (I/O) Modules XM07 and XM14

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

System 450 Series Expansion Modules with Relay Outputs Installation Instructions

Network Integration Engine Product Bulletin

LN Series Communicating Sensors

FX14 Field Controller

Network Control Engine

FX-PCA Advanced Application Programmable Controller Catalog Page

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

LX Series Remote Input/Output (I/O) Controller

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

Field Equipment Controller (FEC) Series Catalog Page Code No. LIT Issued June 2018

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

NIE39/NIE49 Installation Instructions MS-NIE39xx-2, MS-NIE49xx-2

Input/Output Module (IOM) Series Catalog Page

Network Integration Engine

FXVMA Variable Air Volume (VAV) Box Controller

Nevco Indoor LED Scoreboard Installation Manual

Safety and Radio-Frequency Interference

FX40 Supervisory Controller

QUICK START GUIDE M2000 SERIES rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

TC-8900 Controller Units with PM-8900 Power Modules

Infosystem Remote Touchscreen Installation Instructions

Smart Equipment Controls (SEC)

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Advanced Application Field Equipment Controller (FAC) Catalog Page

Rack Input Module Installation Instructions

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued December 2017

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

Unpacking. Installation

rcc.1081 Installation Instructions

P216 Series Condenser Fan Speed Controller

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

3M RFID Tracking Pad Model 770

HARDWARE GUIDE. Boiler Controller M2000 Series. Specifications and Operational Guide

AS-CVTPROx00-0 Zone Bus/N2 Bus Interface Converter

Installing the ipower 70 Room Camera

AD331A & AD332A PCI-X 1-Port Gigabit Ethernet Card Overview

TM-2100 Series Room Command Module

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

2 Mesa Ethernet Dock User s Manual

Allworx Tx 92/24 Telephone Expander Installation Guide

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

Raven Series Standalone Media Converters

FX80 Supervisory Controller Installation Instructions

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

NSD/M1 Installation Instructions

LCS85 Product Bulletin

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, MS-NAE551S-2, NAE Software Release 9.0 Issued August 2017

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

Quick Start Guide. Sabre 1400 Hand-held Scanner

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

CCS ZEC400 VAV Controllers

ZEC310 Zone Damper and BYP200 Bypass Damper Controllers

Bluetooth 2.0+EDR. Bluetooth 2.0+EDR (Enhanced Data Rate)

Owner s Manual AC & BATTERY POWERED FET

Installation Instructions

IP7 -SS40. IP Paging Amplifier. Reference Manual

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

FX-PCA3611 Advanced Application Programmable Controller Installation Instructions

Network Automation Engine

CSM200 Expansion Tray

BEETLE /Fusion Compact. Installation Guide

Priva Blue ID Communication module RS485 SC44

Series. C Series Quick Start Guide. English. One Printer for your Entire Enterprise.

Application. NAE55 Installation Instructions * S* Installation. Parts included. Materials and special tools needed

TruVision IP Thermal Camera Installation Guide

RCM Room Command Module New Style

Controller Specifications

Control different load types with one device

MODEL: VSP735. Compliance. About this Guide. Parts Checklist. FCC part 15. Industry Canada

HE-6800 Series Humidity Transmitters with Temperature Sensor

EZ-LP Quick Start Guide

3M Wrist Strap and Ground Monitor 773. User s Guide

Support for Non-Ultra2 SCSI Devices

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

NCH-1000 (Multiple Breaker Types) Installation Instructions

FEC26 Field Equipment Controller

YCCS System Manager and Zone Coordinator

Transcription:

FX-DIS1710-0 Part No. 24-10240-17, Rev. B Issued April 2016 Applications The FX-DIS1710 Local Controller Display is a stand-alone display module designed for installation on the front panel of an enclosure. The FX-DIS1710 display can connect to the FX-PCAs, FX-PCVs, or to FX-PCG models that do not have integral displays. The display provides a local user interface for the application running in the controller. Use the FX-PCT tool to configure the display. North American Emissions Compliance United States This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case the users will be required to correct the interference at their own expense. Canada This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. one O-ring Refer to the QuickLIT website for the most up-to-date version of this document. one installation instructions sheet Materials and Special Tools Needed power saw for cutting a hole into the panel to hold the display, if no hole is provided small Phillips-head screwdriver Enclosures Use Table 1 to order enclosures for use with the display. Table 1: Enclosures with DIS1710 Cutout Product Code Number Size (in.) Description PAN-ENC1620WDF4 PAN-ENC1620WDP4 PAN-ENC2024WDF4 PAN-ENC2024WDP4 PAN-ENC2424WDF4 PAN-ENC2424WDP4 PAN-ENC2436WDF4 PAN-ENC2436WDP4 PAN-ENC1620FMD4 PAN-ENC2024FMD4 PAN-ENC2424FMD4 PAN-ENC2436FMD4 16 x 20 x 6.62 20 x 24 x 9.25 24 x 24 x 9.25 24 x 36 x 9.25 16 x 20 20 x 24 24 x 24 24 x 36 Standard Johnson Controls Enclosure with Cutout for display Standard Johnson Controls Panel Door with Cutout for display Installation Observe these guidelines when installing the FX-DIS1710 display: Transport the display in the original container to minimize vibration and shock damage to the unit. Verify that all parts were shipped with the display. Do not drop the display or subject it to physical shock. Parts Included one FX-DIS1710 Local Controller Display one communication cable Mounting Location Considerations The display is mounted onto the front panel door of an enclosure. Mounting Dimensions See Figure 1 for the mounting dimensions of the display. Physical Features See Figure 2 for the physical features of the display. 1

Figure 1: FX-DIS1710 Mounting Dimensions, mm/in. Figure 2: FX-DIS1710 Physical Features Mounting Display to Enclosure Door Follow these steps to mount the display onto the front of the enclosure door (Figure 5): 1. Loosen the two thumbscrews on the back plate, but do not remove them. 2. Detach the back plate from the display by using a small Phillips-head screwdriver to remove the two back plate screws. Tilt the back plate forward to remove it from the retaining tabs. 3. Insert the O-ring into the gland (slotted groove) in the back of the display (Figure 4). 4. Insert the display into the front access hole on the panel door. Hold in place. 5. Carefully insert the back plate to the other side of the access hole (inside of the panel door) and secure it to the cutout by hand-tightening the two thumbscrews. You may need to tilt the back plate to slide it onto the two bottom retaining tabs. Preparing the Panel The display is mounted onto the front panel door of the enclosure. The panel door must have a maximum thickness of 6-7/20 mm (1/4 in.). Also, if the panel you intend to use lacks a presized cutout, make the cutout 71 mm x 216 mm (2-2/3 in. x 8-1/2 in.). See Figure 3 for the recommended cutout location. Figure 3: FX-DIS1710 Panel Cutout Dimensions, mm/in. 2

Figure 4: Attaching the Display into Panel Cutout Wiring The display receives power over the Sensor-Actuator (SA) Bus from the FX-PC Series controller. Note: Do not connect the display to an FX-PCG that has an integral display. Also, do not connect more than one display on the same SA Bus. Connecting Cable to Controller Connect the communication cable (included in box) between the SA Bus connector on the back of the display and the SA Bus jack on the front of the controller (Figure 6). The coiled cable is 91 cm (3 ft) in length and can be stretched to a maximum length of 152 cm (5 ft). Figure 6: Connecting the SA Bus Cable 6. Using the screwdriver, tighten the two back plate screws to secure the back plate in place. Tighten the thumbscrews against the panel to provide a snug fit. Important: Do not overtighten the thumbscrews. Overtightening the screws may exert too much pressure on the back plate. Figure 5: FX-DIS1710 Back Plate If the SA Bus jack on the controller is in use, you can wire the display s communication cable to the SA Bus terminal block. Splice one end of the communication cable and connect it to the SA Bus terminal block using the wiring designations in Figure 7. 3

Figure 7: Wiring Cable to SA Bus Terminal Block Setup and Adjustments Power On the Controller 1. Supply power to the controller. 2. Close the panel door of the enclosure. 3. Verify that the display is on and initiating the startup sequence. Commissioning The FX-DIS1710 Local Controller Display does not require commissioning. Cable connection between the FX-DIS1710 Local Controller Display and a commissioned FX controller allows for immediate display function. Ensure that the communication cable is connected between the display and the controller. For more information on commissioning, refer to the Controller Tool Help (LIT-12011147). Troubleshooting Refer to the FX-DIS1710 Local Controller Display Technical Bulletin (LIT-12011666) for information on how to use and troubleshoot the FX-DIS1710 display. Technical Specifications Table 2: FX-DIS1710 Local Controller Display Product Code Number Power Requirement Power Consumption Ambient Operating Temperature Ambient Operating Conditions Ambient Storage Temperature Ambient Storage Conditions Terminations Processor Memory Operating System Network and Serial Interfaces FX-DIS1710 Local Controller Display for FX-PC Series Controllers Nominal 15 volts provided by controller over SA Bus. 2 VA maximum 0 50 C (32 122 F) 10 90% RH, 30 C (86 F) maximum dew point -40 70 C (-40 158 F) 5 95% RH, 30 C (86 F) maximum dew point RJ-12 6-pin jack at Service Port (covered by removable cap-plug) SA Bus connection on back of unit Renesas H8S-2398 16-bit microprocessor 256 KB Flash Memory 8 KB Random Access Memory (RAM) RTOS-H8S Communication to controller over SA Bus 4

Table 2: FX-DIS1710 Local Controller Display Graphic Display Resolution Dimensions (Height x Width x Depth) Housing 240 x 64 pixels with white LED backlighting (adjustable) 85.9 x 238 x 25.8 mm (3.4 x 9.37 x 1.0 in.) Plastic housing material: ABS + polycarbonate Protection: IP20 (IEC60529) Mounting (Height x Width) Shipping Weight Compliance Mount to the outside of the enclosure 70.5 x 216.5 mm (2.78 x 8.525 in.) 0.14 kg (0.3 lb) United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment; FCC Compliant to CFR47, Part 15, Subpart B, Class A Canada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada Compliant, ICES-003 Europe: CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive. Australia and New Zealand: RCM Mark, Australia/NZ Emissions Compliant The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. European Single Point of Contact: WESTENDHOF 3 45143 ESSEN GERMANY NA/SA Single Point of Contact: 507 E MICHIGAN ST MILWAUKEE WI 53202 USA APAC Single Point of Contact: C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls is a registered trademark of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2016 Johnson Controls, Inc. Published in U.S.A. www.johnsoncontrols.com 5