SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables Tools Optional AR-RB Digital Relay P P P P P P AR-RB AR-RB Digital Relay Installation A. B. Use a screwdriver to screw the mounting plate to the wall. Pull cables ends through the access hole in the mounting plate. Attach AR- (EF-V) or AR- (EV-V) to the mounting plate and install screws (supplied) into the holes at the bottom with the allen key. Apply power. LED (green) will light up with one beep. Notice.Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing..wire selection: Use AWG - Shielded Twist Pair to avoid star wiring,cat cable for TCP/IP connection.power supply: Don t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the reader malfunction. The standard installation: Door relay and lock use the same power supply, and reader use independent power supply. Connector Table () Cable: P P P P P P P Wire Application Wire Color Description Lock Relay Blue White ()DCVAmp Purple White ()DCVAmp Lock Relay White ()DCVAmp Door Contact Orange Negative Trigger Input Exit Switch Purple Negative Trigger Input Alarm Relay Gray / Optional (by jumper) Power Thick Red DC Thick Black DC V Cable: P Wire Application Wire Color Description Beeper Pink Beeper Output V/mA, Low LED Yellow Red LED Output V/mA, Max Brown Green LED Output V/mA, Max Door Output Blue White Transistor Output Max. /ma (Open Collector Active Low) Wiegand Thin Green Wiegand DAT: Input Thin Blue Wiegand DAT: Input WG Door Contact Orange Negative Trigger Input WG Exit Switch Purple Negative Trigger Input Cable: P Wire Application Wire Color Description --- --- --- --- TCP/IP Output Orange White Net - TX+ Orange Net - TX- Green White Net - RX+ Green Net - RX- --- --- Cable: P Wire Application Wire Color Description RS- for Lift Thick Green RS-(B-) Thick Blue RS-(A+)
Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange Yellow Description Cable: P Wire Application Power Security trigger signal Arming Duress Wire Color Red Purple Red White Yellow White Description DC Output Security trigger signal Output Arming Output Duress Output Front Panel & Indicator Power(Green) Alarm(Red) Alarm(Green) OK(Green) Error(Red) In processing(green). System will automatically exit from Programming Mode when inactivating for seconds.. LED status indicates controller s mode and status. OK (green) blinking constantly when operates in Programming Mode or flashing an existed card in card learn mode, it comes beeps warning and LCD panel displays Same Card: user address / card number Error (red) invalid card with beeps warning and LCD panel displays Card Number Err! or in anti-pass-back mode, when violates the access, it comes one beep warning and LCD panel displays Anti-pass Error! Arming (green) arming on status Alarm (red) any abnormal condition occurs. Keypad will be locked up sec. when constantly entering incorrect pin code or master code.. Maximum error in[ut of pin code and master code can be changed via the software Server (default: times) PWR / WED Duty : : 9 : OK PWR ERR : 9 : SE RI ES V SE RI ES V OK ERR PRE ARM PRE ARM WED Duty : Networking : / and interactively flash between the Month and DAY. [e.g.] / Stand-alone : No flashing [e.g.] / ( Reference to picture) Wiring Diagram Connect to Electric Bolt Electric Bolt E Connect to Magnet Lock Exit Switch DC Magnet Lock PB DC DC P P PB DC Copyright by SOYAL Technology Co., Ltd.. All rights reserved.
SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Connect to Electric Strike Connect to Door Contact Electric Strike PB DC P DC DC Door Contact ALM DC P CTL Alarm Relay Outpot Module Door Contact Strengthen security with AR-RB Connect to Reader Electric Bolt P DDR DC P CTL PB DC AR-RB Electric Bolt Reader E CTL BZ RLED GLED WG WG Exit Switch DC P BZ RLED GLED Door Output WG WG WG-DS WG-PB P Door Contact DC If any fire emergency, the people can escape by press a switch to open all doors Electric Strike DC Magnet Lock DC Electric Bolt E DC P PB Transistor IN PB P P PB Transistor IN Fire Emergency
Biometrics Device Access controller Fingerprint & Finger Vein V Programming A. Keyboard Lock/ Unlock Lock/ Unlock Press and, and at the same time to lock keyboard. Press again to unlock. B. Entering and Exiting Programming Mode Entering Input or PPPPPP [e.g.] The Default Value=. If already changed the Master Code=, input Access programming mode P.S.If entering no instruction within sec., it will automatically leave the programming mode. Exiting Press the repeatedly Quit or Quit and Arming (Please refer to alarm / arming setting) Changing the Master Code Access programming mode Tools Master Code Input the -digit new master code Succeeded C. Initial setup Language Setting Access programming mode Tools Language EN Succeeded Initial system... Node ID of Reader Setting Access programming mode Parameters[] Node ID Input New Node ID : ~ (default value:) Main Door Number : ~ WG Door Number : ~ Show UID (=No,=WG,=ABA,=HEX) Enable DHCP(:No,:En,=Exit) Succeeded D. Adding and Deleting Tag User capacity: (~) Tag Information CARD CODE SITE CODE CARD CODE SITE CODE Adding Tag by Tag ID Access programming mode Add/Delete Add -> Card ID Input -digit user address Input Site Code Input Card Code Adding Tag by RF Learn Function Access programming mode Add/Delete Add -> RF-Learn Input -digit user address Input Tag Units(pcs) Close Tag into RF Area If a batch of tags are Sequential, input Tag Units(pcs) in the quantity of the tags and present the tag with the lowest number to the controller. Suspend User Address Access programming mode Add/Delete Suspend -> Addr Input Start address Input End address Suspend Tag by Tag ID Access programming mode Add/Delete Suspend -> ID # Input Site Code Input Card Code Recover User Address Access programming mode Add/Delete Delete -> Addr Input Start address Input End address Recover Tag by Tag ID Access programming mode Add/Delete Delete -> ID # Input Site Code Input Card Code Deleteing User Address Access programming mode Add/Delete Delete -> Addr Input Start address Input End address Deleteing Tag by Tag ID Access programming mode Add/Delete Delete -> ID # Input Site Code Input Card Code Setting up the access mode Access programming mode User Setting Access Mode Input User Address : Invalid; : Card ; : Card or PIN; : Card & PIN E. PIN Code Access programming mode User Setting Password Input -digit user address Input -digit PIN (~9999) Succeeded Or via Client set it on Users screen
SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V F. Adding / Deleting Fingerprint or Finger-Vein Adding Access programming mode User Setting Enroll FP Key in -digit user address or different fingers on the sensor lens Succeeded P.S. The AR-EF need to collect twice for each fingerprint, and the AR-EV need to collect three times. Deleting Access programming mode User Setting Delete FP Key in -digit user address Succeeded P.S. If you want to delete all users FP, key in 99999 # G. Access Mode Access programming mode User Setting Access Mode Finger Identify Result Access Mode Hardware Client Hardware Client Key in -digit user address (~999) : Must :Invalid; :Card; : Card or PIN; : Card and PIN :Invalid Finger Identify: : Must ; : Ignore : Ignore Invalid User Succeeded H. Arming Password Access programming mode Parameters[] Arming PWD Input -digit PIN (~9999; Default: ) Succeeded Or via Server and set it on AR-9E screen I. Arming Delay Time Access programming mode Parameters[] ArmingDelayTm Enter armed sta. Delay time(sec),range:~; Armed pulse out-put time. (ms),range:~ Succeeded J. Duress Code Access programming mode Parameters[] Duress Code sets (select one) Input -digit PIN (~9999) Succeeded Or via Server to set it on AR-9E-V screen Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a warning signal. K. Terminal Port Access programming mode Tools Terminal Port :Lift ; :Host ; :LED ; :PRN (default value:) Baud Selection (default value:9) Succeeded L. Setting up the alarm / arming Conditions:. Arming enabled.alarm system connected Application:. Door open too long: Door is open longer than door relay time plus door close time.. Force open (Opened without a valid user card): Access by force or illegal procedure.. Door position abnormal: When power is off and then on, reader on arming before power off. Enable/Disable the arming status: Standby Mode Card only Card or PIN Card and PIN Open the door Present the tag to reader Input digits arming PWD Access Programming mode Enable: Access programming mode [Use FP] can substitute for [Induct valid card]. :Card :Card or PIN :Card and PIN No open the door Input digits arming PWD Present the tag to reader : Must : Ignore : Must : Ignore : Must : Ignore Input user address Input digits individual PWD Input digits arming PWD Quit & Arming Disable: Access programming mode Quit Finger+Card. Card Only. Finger Only. Finger+Card. Finger+PIN. Card+Finger+PIN. Card+Finger+Card. PIN+Finger+PIN. PIN+Finger+Card. Card Only. PIN Only. Finger Only Finger+Card+PIN. Card+PIN. Finger+PIN Present the tag to reader Input digits individual PWD Input digits arming PWD
Biometrics Device Access controller Fingerprint & Finger Vein V M. Anti-pass-back While connect with AR-U, AR-H/U(WG mode) and AR-U for anti-pass-back function, the access mode needs to be "Card" only. Device enable Access programming mode Parameters[] Anti-pass-back master controller select [: Yes] WG select [: Yes] Card user enable Access programming mode Add/ Delete 9 Antipass Group Input -digit starting user address Input -digit ending user address must select [: Yes] N. Lift control [e.g.] Connect with AR-ROB to control which floors the user will be able to access. (BAUD9) Setting Lift control Access programming mode Tools Terminal Port :Lift Baud Selection : 9 Access programming mode Tools Terminal Port :Lift (need to use L) Set Floor/ Stop 9 9 Single floor Access programming mode User Setting Single Floor Input -digit user address Input single floor number: ~ Multi floors Access programming mode User Setting Multi Floor Input -digit user address Select range: or or or Input digits multi floors number [:disable, : enable] [e.g.] Set NO., can use it with the F and F: Access programming mode User Setting Multi Floor O. Alarm Clock (for Factory) Access programming mode Tools 9 Daily Alarm Set (~) Set Start Tm ( Hours) ; Set Effect Sec. (Seconds as the bell time, Range:~) Set Weekday (:disable, : enable) Succeeded Hardware installation 9 9 9 9 Horn Music Box Board Mike device Mike device DC DC Relay Board CTL Mike's sound wire Mike's sound wire M M Music Box Output to M and M P ALM P. OpenZone Access programming mode Parameters[] OnOff OpenZone Main Auto Open Zone (:disable,:enable) Open Door Imm. During Open Zone (:No,:Yes) WG Port Auto Open Zone (:disable,:enable) Open Door Imm. During Open Zone (:No,:Yes) Succeeded Q. Open TimeZone Access programming mode Tools Open TimeZone Set (~) Time ( Hours) ; Main Port (:disable, : enable) ; WG Port (:disable, : enable) Weekday (:disable, : enable) succeeded
SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Firmware Upgrade Get the upgrade software from SOYAL or our distributor and run UdpUpdater software Execute the software The software is within SOYAL CD or Login the SOYAL web to downloads Update the firmware [Please login the SOYAL web to download the new ISP Firmware.]. Input the Target Address and Port. [Load F/W] open the documents that have the new ISP Firmware. Click the new ISP Firmware and [Open] it. Click [Update F/W] to start the firmware update. Till the screen shown [Firmware Update is Complete] Restoring Factory Settings Reset all device parameters and user card data Reset all device parameters and user card data: Access programming mode Parameters 9 Factory Reset : System Param ; : User Setting ; : System & User Reset IP Setting: When the device's power is on, press the RESET button the main board untill the ERR (Red) LED of screen lights up. (Reference to picture) After operation as above, you will hear the long reminder sound,and wait until the sound disappear then reset the power of the controller,the device will restore factory setting. After done the "Factory Reset", the External Communication Port must be reset. Or the biometric sensor won't be functional. Tools Ext. Comm Port (:FP- ; :Lift ; :Vein ; :FP-9 ; :Reserved ) RESET Manu Tree. Add/ Delete. Add > Card ID. Add > RF Learn. Suspend > Address. Suspend > ID #. Delete > Address. Delete > ID #. Recover > Address. Recover > ID # 9. Antipass Group. User Setting. Password. Access Mode. Extend Options. Single Floor. Multi Floor. Enroll Finger. Delete Finger. Parameters[]. Node ID. OnOff OpenZone. Door Relay Tm. Door Close Tm. Alarm Relay Tm. Alarm Delay Tm. Arming Delay Tm. Arming PWD. Parameters[]. Auto Relock. Egress(R.T.E). Miscellaneous. Force Open. Close & Stop. Anti-pass-back. Duress Code. Password Mode 9. Factory Reset. Tools. Language. Master Code. Master Range. Terminal Port. Ext.Comm Port. Open Time Zone. Informations. Clock Setting 9. Daily Alarm. Quit. Quit & Arming
Biometrics Device Access controller Fingerprint & Finger Vein V IP Setting Open your Web Browser and input factory default IP address: http://9... If the IP address of AR- (EF/EV-V) has changed We must enter the new IP address. Page menu Monitor the on-line computer IP Setting Change the Log-in information Current State Online Status is able to monitor and show which computer is linking on Ethernet Module Show which computer is linking on Ethernet Module. Current IP address of the AR- (EF/EV-V) Log-in User Password When you choose the "Networking Setting" or "User Password" at first. Log-in window will pop out and please input At the Factory Default User name: admin Password: No as default value,so please just press OK to log-in admin Networking Setting You will find initial IP Address 9... and check MAC Address is the same as sticker on Ethernet Module device. Please revise IP address you want, and then click Update button. After updating the IP, please re-connect the Web Browser by new IP address. User Password Change the log-in password to lock the IP setting of Ethernet Module. The password composes of characters at most, it can be either A~Z or ~9.