using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

Similar documents
lighting control. Each controller switches up to 48 high voltage, 20-amp lighting circuits, using

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II

ACX Series. Access Controller for Ethernet

Andover ContinuumTM Infinet II

BACnet. b3810 Series Local Controllers

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

TAC I/NETTM 1284, 1280, Security Control Unit

Andover ContinuumTM. b3850 Series Terminal Controllers

BACnet. b3867 Terminal Controllers

Andover Continuum. Power Supplies with or without UPS

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Andover Continuum. Family of Security Products

Andover ContinuumTM. Family of Security Products

Quick Start Installation Guide

istar Ultra Access Controller For up to 32 Readers 1 Features Supports up to 32 Readers Network Ready 1 / 5

I/O Modules. user interface modules in a single controller location to meet your building s control and

Configuring Areas and Doors

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

6222 Two Door Module Technical Operations Manual

PRO3200 Professional Modular Access Control Hardware

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.

ACX 700 Installation Guide. Technical Manuals Online! -

PRO2200 Professional Modular Access Control Hardware

Web-based Access Control System. Employee access. EMBEDDED Web Browser

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

istar Pro Installation Guide

Installation Instructions for UL Rev A

Quick Start Installation Guide

NetAXS-123: One door, compact (plastic) enclosure. NetAXS-123: One door, standard (metal) enclosure with tamper switch and terminal block

SmartLock Controller INSTALLATION MANUAL

TDSi MICROgarde type door controllers offer a fully featured door controller with up to 25,000 card memory.

Web-based Access Control System. Lower Cost of Ownership

UC-2000 Installation Manual Unicorn Computers Technology Limited

SNAP, CLICK, DONE. Getting Started Guide

DS BAS 08/99 UNC 532

NetAXS-123: One door, compact (plastic) enclosure. NetAXS-123: One door, standard (metal) enclosure with power supply and battery

CardaxFT Reader I/O Interface

Two Door Controller GEN-045

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

ACTsmart2 Product Range Operating and Installation Instructions

SmartLock Pro INSTALLATION MANUAL

Suprex RS-485 SPX-7500 Wired Reader-Extender

VICON ACCESS CONTROL CONTROLLERS

NetAXS. Hosted Video Services. Cloud Hosted Access Control. Retail Professional Services Convenience

CA-A480-A Elevator Controller. Reference & Installation Manual

Click Save to return to the main Setup screen.

PXL-250 Tiger Controller

ACCESS CONTROL SYSTEM

DESIGN GUIDE FOR INFINITY SYSTEMS

SINGLE READER EXPANSION MODULE

T h e re is an upgrade route to larger configurations. O v e rv i e w

System Galaxy Hardware Manual

4 balanced inputs 1 relay output

ACTPRO ACCESS CONTROL. Specification Guide

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

Quick Start Installation Guide

DG-800 Stand-Alone Proximity Reader Instruction Manual

CM9760-KBD and CM9760-KBR Series Keyboards FULL FUNCTION, VARIABLE-SPEED, PTZ CONTROL

Expandable Power Systems

Gallagher GBUS Devices

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

TC Modular Series for BACnet Networks

Control Panel Solutions

KT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC.

Controller 3000, dependent on reader technology and site configuration. All I/O functionality is provided on the Controller 3000.

IQ21x Series Controllers

Quick Start Installation Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

NetAXS. Cloud-Hosted Services. Cloud Hosted Access Control. Retail Property Management Franchises

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

Access Terminal IF-800

Analog Voltage Combination Module

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

inc.

Multi-Point Gas Detection and Control System

TEL: (203) FAX: (203) WEB:

IPassan Installation guide

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER)

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

EA500. Installation Instructions Transponder

controller data sheet JACE 8000 PRODUCT DEFINITION

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Premium Online Series

EP-ELVCTL Elevator Control (NION-16C48M)

Intrusion Control Panels Quick Guide. May 2015

DIGITUS BIOMETRICS PRODUCT GUIDE 2013

Digitus Biometrics Product Guide

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

ENGINEERING SPECIFICATIONS SENSAPHONE 2000

NS1 Connection Unit Guide

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Transcription:

Infinity ACX 700 Access Control Unit The Infinity ACX 700 is a programmable, stand-alone access controller that is a basic building block of the Infinity Security Management System. Each ACX 700 controls access to 2 doors (up to 4 doors using optional EMX 190 expansion modules), and makes access decisions based on its own distributed data base. Each door may be controlled by a card reader, keypad, or a combination of both for high security. Up to 62 ACX 700s may be networked to one Infinity CX series network controller, and up to 1024 ACX 700s may be networked together on one site. In addition, the ACX 700 may be networked with other Infinity controllers including the IDX 800 Intrusion Detection Controller, LCX 890 Lighting Controller, and the DCX 250 Touch Screen Display for a fully integrated system. The ACX 700 is available with a locked enclosure (shown), or in an open class version suitable for panel mounting. Input power is switch-selectable between 24, 115, or 230 VAC, or can be provided from a 12 VDC UPS power source. F E A T U R E S Stand-Alone Two-Door Access/ Security Controller UL 294, UL 1076 Agency Listings Peer-to-Peer Communications Provide Transparent Data Transfer Distributed Database Stores Card Records at the Local Access Controller for Reliability 12 VDC Connection For Full UPS Operation COMMUNICATIONS Communication to the Infinity ACX 700 is handled via the Infinet bus, a twisted pair, half duplex RS-485 interface. Communication is accomplished with a token passing protocol which provides full transparent data transfer between all Infinity controllers on the network. ACX 700 nodes have priority status on the bus to ensure the fastest possible alarm throughput. INPUTS The ACX 700 contains inputs for two Wiegand or ABA protocol card readers, two 3 x 4 matrix keypads, two supervised door status inputs, two supervised request-to-exit inputs, and four supervised general purpose alarm inputs. A built-in tamper switch provides alarm notification when either the cabinet door is opened or when the unit is removed from the wall. The ACX 700 can be expanded to four readers with the addition of two EMX 190 expansion modules. The EMX 190 also adds one supervised door switch input and one supervised request-to-exit input. Two Built-In Tamper Switches with Alarm Notification Switch-Selectable Wiegand or ABA Reader Protocols Wiegand, Proximity, and Magnetic Stripe Reader Support Keypad and Supervised Alarm Inputs Offer Optimum Flexibility in Door Control EMX 190 Expansion Module Capability Provides Up to 2 Additional Card Readers and Doors

Infinity ACX 700 Access Control Unit OUTPUTS The ACX 700 has two 5 amp, Form C relay outputs for door control. A third Form C relay is available for fail-safe alarming or custom programming. Each EMX 190 provides one additional door output. Outputs on the ACX 700 include software feedback of the switch position. PROGRAMMING A fully prompted access control database editor makes data entry easy for card records, readers, areas, schedules, and access clearance codes. Resident intelligence at the ACX 700 level allows for database storage for up to 1,700 card holders. Additional database storage capacity is provided at the CX network controller level, and at the SX 8000 workstations. Up to 57,000 card holders may be created for each local access control site. Site codes, card formats, and other degrade mode parameters are stored in non-volatile EEPROM in each ACX 700. Each door can be configured to operate based on card only, card plus personal ID number (PIN), or keypad only. The door s operating mode can even be changed based on time-of-day or other events for optimum flexibility. Each keypad can also permit entry of a duress alarm code that can initiate an alarm sequence at any of the controllers or at the SX 8000 workstation. Time-based anti-passback and entry/egress anti-passback are available to prevent tailgating. Entry/egress antipassback is system-wide and can be performed by readers located on different controllers across the network. Using Andover s powerful Plain English programming, the ACX 700 can also be used for custom access control sequences such as two-man rule, optical turnstile control, and man trap configurations.

ACX 700 Dimensional Drawing

Infinity ACX 700 Access Control Unit S P E C I F I C A T I O N S ELECTRICAL Power: Power Consumption: Overload Protection: Real-Time Clock: 24 / 115 / 230 VAC, 50/60 Hz, field selectable 20 VA Fused with 3 amp 3 AG fuse. MOV protected. Battery backed clock, synchronized through Infinet by CX or CMX Network Controller. MECHANICAL Operating Environment: Size: Weight: 32 to 120 F (0-49 C), 10 to 95% RH (non-condensing) 15"H x 11"W x 3 1/2" D (381.0H x 279.4W x 88.9D)mm (no enclosure) 19"H x 15"W x 4 3/4" D (382.6H x 281.0W x 120.6D)mm (with enclosure) 7.0 lbs. (3.1 kg) (no enclosure) 21 lbs. (9.5 kg) (with enclosure) Enclosure Type: Standard enclosure - UL open class sheet metal, IP 10 Optional NEMA 1-style enclosure, flammability rating of UL 94-5 V, IP 20 BATTERY Battery Backup: Replaceable, non-rechargeable lithium battery provides 7 years accumulated power failure backup of RAM memory and real-time clock. Input terminals provided for 12 VDC battery and charger (customer-furnished) for full UPS operation. COMMUNICATIONS Communications Interface : Communications Speed: Bus Length: Bus Media: Through Infinet field bus to Infinity CX or CMX Network Controllers or Lap-Top Service Tool. 1200 to 19.2k baud 4,000 ft. (1,220m) standard for Infinet, InfiLink amplification module allows extension to longer distances and is required after every group of 32 units on the network. Infinet: twisted, shielded pair, approved low capacitance cable Comm. Error Checking: International Standard CRC 16

S P E C I F I C A T I O N S (Cont'd) INPUTS/OUTPUTS Inputs Card Readers: Card Reader Type: Maximum No. of Bits/Card: Card Reader Power: Distance Card Rdr. to ACX 700: 2 (expandable to 4 with addition of 2 EMX 190 card reader expansion modules). Wiegand or ABA, switch-selectable per reader. Supports Wiegand, Proximity, and Magnetic Stripe readers. 64 (Wiegand), 256 (ABA) 5 VDC, 35 ma per reader 500 ft. maximum using 18 gauge wire Keypad Inputs: 2 Keypad Type: 3 X 4 matrix keypad Door Status Inputs: 2 Request-to-Exit Inputs: 2 General Alarm Inputs: 4 Input Type for All the Above: Input Protection: Tamper Switch: Single or double resistor supervision 24 VAC/DC continuous shorting 2 (Cabinet door and cabinet rear). Terminals also provided for external switch. Outputs Door Outputs: Auxiliary Output: Output Rating: Output Protection: Overrides: Expansion Bus: EMX 190 Inputs: EMX 190 Output: 2 Form C relays 1 Form C relay 30 VAC/DC, 5 amp 1500 V transients. Each output is equipped with a three-position switch for manual control of the relay. Switch position is viewable and logged through software. Up to 2 EMX 190 Card Reader Expansion Modules may be added to each ACX 700, providing up to 2 additional card readers and doors. Other Infinity expansion modules may also be added. See the Infinity Expansion Module Configuration Guide for more information. 1 Card reader (Wiegand or ABA), 1 door status, 1 Request-to-exit input 1 Form C door strike relay, with override switch.

S P E C I F I C A T I O N S (Cont'd) CONNECTIONS Power: Inputs: Outputs: Communications Bus: Three-position barrier strip Removable two-piece terminal strip Screw terminals Removable two-piece terminal strip GENERAL Memory: 512K EPROM, 1K bits EEPROM, 256K RAM Max. Personnel Rcrds/700: 1,700 Max. Personnel Rcrds/Site: 57,000 AGENCY LISTINGS UL/CUL 916, 1076, UL 294 for Access Control, FCC, CE OPTIONS NEMA 1-Style Enclosure for Wall Mounting Andover Controls Corporation World Headquarters 300 Brickstone Square Andover, Massachusetts 01810 USA Tel: 508 470 0555 Fax: 508 470 0946 Andover Controls (Europe) Ltd. Smisby Road Ashby-de-la-Zouch Leicestershire LE6 5UG Tel: 01530 417733 Fax: 01530 414225 Copyright 1996, Andover Controls Corporation. Data subject to change without notice. Consult Andover Product Installation Guides for exact installation instructions and specifications. #DS-ACX700-3.96