NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release MPR User Guide

Similar documents
5620 SAM SERVICE AWARE MANAGER 14.0 R3. MPR User Guide

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release MPR User Guide

Alcatel-Lucent 5620 SERVICE AWARE MANAGER MPR USER GUIDE R7 December HE AAAG TQZZA Edition 01

Alcatel-Lucent 5620 SERVICE AWARE MANAGER. Release 13.0 R2 May HE AAAB TQZZA Edition 01 MPR USER GUIDE

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) 9500 MPTSUB6 Driver Version Guide

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) 9500 MPTBWA Version Guide

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release Optical Integration Module User Guide

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release Statistics Management Guide

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release Optical Integration Module User Guide

Software Status Detail. [6] Click the Yes button to begin the download process.

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release Integration Guide

9500 MPR. Indoor: MSS-8/MSS-4 + Outdoor: ODU300 / MPT-HC / MPT- HC V2 / MPT-MC. User Manual. Rel. 3.1

ALCATEL-LUCENT 9500 MICROWAVE PACKET RADIO RELEASE 3 ANSI

Alcatel-Lucent MICROWAVE PACKET RADIO for ANSI and ETSI RELEASE MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01

Giga Orion DATASHEET. DS-1025-E 1 of 5

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release Integration Guide

Alcatel-Lucent 5620 SERVICE AWARE MANAGER. Release 12.0 R1 March HE AAAA TQZZA Edition 01 MPR USER GUIDE

Understanding the Carrier Packet Transport System

Apex Orion DATASHEET. DS-1026-E 1 of 5

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release Troubleshooting Guide

5620 SAM SERVICE AWARE MANAGER 14.0 R9. Applications Guide. 3HE AAAG-TQZZA Issue 1 November 2017

Future Orient High Capacity Nodal Equipment

FibeAir IP-10 Series. Product Guide

NETSMART Network Management Solutions

Title page. Alcatel-Lucent 5620 SERVICE AWARE MANAGER

Alcatel-Lucent 9500 Microwave Packet Radio (ETSI Markets)

Giga Lynx DATASHEET. DS-1029-F 1 of 5

Alcatel-Lucent 5620 SERVICE AWARE MANAGER. Release 13.0 R2 May HE AAAB TQZZA Edition 01 NUAGE VIRTUALIZATION USER GUIDE

NSP Network Services Platform Release Deployment Overview. 3HE AAAA-TQZZA Issue 1 March 2018

General information on the radio performance monitoring process

Mobile Network Evolution

Management Software. SmartView TM EMS (Element Management System) Management Software. Management Software. Polled Network Elements

Connect the PC and Log into the GUI

Management Software. SmartView TM EMS (Element Management System) Management Software. Management Software SmartView TM EMS. Polled Network Elements

Management Software. SmartView TM EMS (Element Management System) 1-1. Management Software. Polled Network Elements

SmartView EMS. Central EMS. SmartConfig. Fault, Configuration, Accounting, Performance & Security Management (FCAPS)

Configuring High Availability (HA)

Optical Network 2011 Training Programs. Catalog of Course Descriptions

Smart IDU. Digital Microwave Radio SM Sygnus SHC. User s Manual

NEXT GENERATION BACKHAUL NETWORKS

Alcatel-Lucent 5620 SERVICE AWARE MANAGER SYSTEM ADMINISTRATOR GUIDE. Release 13.0 R6 November HE AAAF TQZZA Issue 1

Wireless Metro Ethernet Networks

Lenovo ThinkAgile XClarity Integrator for Nutanix Installation and User's Guide

RADWIN 2000 Release LA Release Note

Configuration/ Alarm EPS

IP Broadband Network Management 2016 Training Programs. Catalog of Course Descriptions

Relea Re s lea e 7 s. e

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

Link Installation: The RADWIN Manager

SkyWay-MAX Operator s Guide

ProSafe Plus Switch Utility

ProSAFE 8-Port 10-Gigabit Web Managed Switch Model XS708Ev2 User Manual

Apex Lynx DATASHEET. DS-1030-E 1 of 5

CTC Information and Shortcuts

Optical Networks Training Programs. Catalog of Course Descriptions

HP Network Node Manager 9: Getting Started. Manage your network effectively with NNMi. Marius Vilemaitis. J enterprise PUBLISHING MUMBAI BIRMINGHAM

SKYWAY-XM SERIES PTP Microwave Radio System User Interface Guide

NMS300 Network Management System Application

OPTI-6100 Series Optical Access Multi-Service Provisioning Platform (MSPP)

ULTRA HIGH CAPACITY IPLINK MODEL SALINAS IPLINK-2400

FieldView. Management Suite

PTP 810 SOLUTIONS LICENSED MICROWAVE WITH NATIVE ETHERNET AND NATIVE TDM SUPPORT IN ONE PLATFORM. PTP 810 SPECIFICATION SHEET from Release 01-00

IP Broadband Network Management 2018 Training Programs. Catalog of Course Descriptions

Gmux Modular TDMoIP Gateway FEATURES

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

Mission-critical multimedia. FibeAir IP-20 Assured Platform

Navigating Cisco Prime Campus Manager Tasks in LMS 4.1

CTC Information and Shortcuts

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Connect the PC and Log into the GUI

How to stack multiple NCT192 IP DSLAMs in untagged mode and VLAN tagged mode

Turn Up a Node. Before You Begin CHAPTER

H3C imc. Branch Intelligent Management System. User Manual. Hangzhou H3C Technologies Co., Ltd.

CTC Information and Shortcuts

DRS/FI. Digital Radio System/Full Indoor (Hybrid) Frequency Range from 4 to 11GHz HIGH CAPACITY MW SYSTEMS. System Features

- 128 x Gigabit Ethernet connections - 32 x 4G Fibre Channel connections - 8 x 8G Fibre Channel connections - down to 2 Mbps

ProSAFE 8-Port and 16-Port 10-Gigabit Ethernet Web Managed Switch Models XS708Ev2 and XS716E User Manual

building better backhaul Dragonwave Product Guide

SDX :30:09 UTC Citrix Systems, Inc. All rights reserved. Terms of Use Trademarks Privacy Statement

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) Release System Architecture Guide

Cisco Unified Serviceability

Using the Prime Performance Manager Web Interface

Understanding Feature and Network Services in Cisco Unified Serviceability

Traverse/TransNav Upgrade Guide

Add and Organize Devices

Loop-IP6763 TDMoEthernet Aggregator

NS-090. Carrier Ethernet Based on MPLS-TP SERIES NS: NEW TECHNOLOGIES. PTCL Specifications NS-090 PAKISTAN TELECOMMUNICATION COMPANY LIMITED

Cisco Transport Controller Operation

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch Web UI Reference Guide

esight V300R001C10 SLA Technical White Paper Issue 01 Date HUAWEI TECHNOLOGIES CO., LTD.

Telecom Point to Point Radio

Configure Controller and AP Settings

Barracuda Link Balancer

640P. High-Capacity Wireless PDH/Ethernet Solutions. 64 E1/T1 wireless transmission. Enabling cellular operators to build their future networks today

PTP 810i ALL-INDOOR SOLUTIONS

SM Cirius LM 175/200+ Mbps Ethernet + 16 T1/E1

KYOCERA Net Admin User Guide

Version No. Build Date No./ Release Date

Oracle Communications Tekelec HLR Router. HP Hardware Disaster Recovery Guide

CTR8500/8300 Installation, Operation and Maintenance (CE/Layer 2) TRN-WW-CTR85X83XL2-01. Hamilton, Scotland, UK Lagos, Nigeria

Transcription:

NSP Network Services Platform Network Functions Manager - Packet (NFM-P) MPR User Guide 3HE-11997-AAAA-TQZZA

Legal notice Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners. The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein. 2017 Nokia. 2 3HE-11997-AAAA-TQZZA

Contents About this document...7 1 Safety information...9 1.1 Structure of safety statements...9 2 What s new?...11 2.1 Overview...11 2.2 What s new in NFM-P for 9500 MPR...11 3 9500 MPR Overview...13 3.1 9500 MPR device support...13 3.2 9500 MPR card support...15 3.3 Supported 9500 MPR device objects and auxiliary equipment...15 3.4 9500 MPR statistics support...19 3.5 To configure radio interface performance management statistics at the port level...22 3.6 To configure bulk changes for radio interface performance management statistics...23 3.7 9500 MPR NEtO support...24 3.8 WebCT...26 3.9 To open WebCT from NFM-P...26 3.10 Workflow to manage 9500 MPR devices...27 4 9500 MPR device commissioning and management...31 4.1 General description...31 4.2 9500 MPR management...31 4.3 Workflow to commission and manage 9500 MPR devices...37 4.4 To prepare a 9500 MPR for NFM-P management...37 4.5 To configure polling for an 9500 MPR...39 4.6 To collect 9500 MPR statistics from NFM-P auxiliary server...40 4.7 To enable NFM-P management of 9500 MPR devices...41 5 9500 MPR software upgrade...43 5.1 Software upgrade workflow...43 5.2 To perform an on-demand 9500 MPR software upgrade...44 5.3 To manage the 9500 MPR running software...45 3HE-11997-AAAA-TQZZA 3

6 9500 MPR migration to revised service model...47 6.1 Migration workflow...47 6.2 To perform pre-upgrade tasks...47 6.3 To perform post-upgrade tasks...48 7 9500 MPR SCM device management...51 7.1 Secure certification mode...51 7.2 Workflow to manage 9500 MPR SCM devices...53 7.3 To configure an SNMPv3 user account on an 9500 MPR SCM device...54 7.4 To configure 9500 MPR SCM NE mediation...55 7.5 To configure a discovery rule...56 7.6 To retrieve logs stored by 9500 MPR SCM devices...57 8 9500 MPR object configuration...59 8.1 Overview...59 8.2 Workflow to configure and manage 9500 MPR device objects...59 8.3 To configure the system settings on a 9500 MPR...60 8.4 To resolve 9500 MPR MIB inconsistencies...61 8.5 To update the software activation status for 9500 MPRe nodes...62 8.6 To configure a scope of command role for NEtO access...63 8.7 To cross-launch the NEtO from NFM-P GUI...64 8.8 To configure QoS for inband TMN interfaces on the 9500 MPR...65 9 9500 MPR shelf object configuration...67 9.1 Overview...67 9.2 Workflow to manage shelf objects on 9500 MPR devices...68 9.3 To configure a 9500 MPR basic or advanced fan tray...69 9.4 To migrate the 9500 MPRe connected to a 7705 SAR from standalone mode to single NE mode...70 10 9500 MPR port object configuration...73 10.1 Overview...73 10.2 Workflow to manage port objects on 9500 MPR devices...74 10.3 To configure 9500 MPR Ethernet ports...75 10.4 To collect and view analog Radio statistics on 9500 MPR 1x Radio modem ports...76 10.5 To collect performance management statistics on 9500 MPR 1x Radio modem ports...77 10.6 To configure 9500 MPR port segregation on an EAS module...78 10.7 To configure a power source for 9500 MPR card slots...79 10.8 To configure a loopback test on 9500 MPR ports...80 4 3HE-11997-AAAA-TQZZA

10.9 To configure 802.3ah EFM OAM remote loopbacks on 9500 MPR ports...81 10.10 To configure Tx mute on radio ports...82 11 9500 MPR LAG object configuration...85 11.1 Overview...85 11.2 Workflow to configure and manage 9500 MPR LAG objects...86 11.3 To create an Ethernet LAG on a 9500 MPR...86 11.4 To delete a 9500 MPR Ethernet LAG...88 12 9500 MPR synchronization management...91 12.1 Introduction...91 12.2 IEEE 1588v2 PTP clocks...91 12.3 To configure synchronization on 9500 MPR Ethernet ports...94 12.4 To configure synchronization on a CorEvo card or MSS-1 shelf using SYNC-IO SFPs...94 12.5 To configure an IEEEv2 1588 TC on a 9500 MPR shelf...95 12.6 To configure IEEEv2 1588 BC and OC PTP clocks...95 12.7 To configure the PTP clock as a synchronization source...97 12.8 To configure the ToD...99 13 9500 MPR inventory management...101 13.1 Radio port inventory 9500 MPRe and 9500 MSS-1c...101 13.2 To list and sort inventory information...101 13.3 To save an inventory list...102 13.4 To configure radio port inventory for 9500 MPRe and 9500 MSS-1c devices...103 13.5 Radio port inventory 9500 MPR (ANSI and ETSI) devices...104 13.6 Procedure to configure radio port inventory for 9500 MPR ANSI and ETSI devices...104 13.7 Radio LAG member inventory 9500 MPR ANSI and ETSI devices...105 13.8 To configure radio LAG member inventory for 9500 MPR ANSI and ETSI devices...105 14 9500 MPR QoS policies...107 14.1 Overview...107 14.2 Workflow to configure 9500 MPR QoS policies...107 14.3 To configure a 9500 Radio Interface Queue Map policy...108 14.4 To configure a 9500 NE QoS policy...109 15 9500 MPR service tunnels...111 15.1 Overview...111 15.2 Configuring service tunnels on a 9500 MPR...116 3HE-11997-AAAA-TQZZA 5

15.3 To create an Ethernet radio ring on a 9500 MPR...117 16 9500 MPR service management...121 16.1 Microwave backhaul service configuration...121 16.2 To configure microwave backhaul services...124 16.3 To complete ring by automatically adding the ring adjacencies...127 16.4 To copy a microwave backhaul service...130 16.5 To view the microwave backhaul service objects...132 16.6 Microwave backhaul service discovery...134 16.7 To discover a microwave backhaul service...135 16.8 To move 9500 MPR backhaul sites...136 16.9 To separate microwave backhaul service topologies...138 16.10 Microwave backhaul service associations...139 16.11 Microwave backhaul service considerations/limitations...145 17 9500 MPR composite service...147 17.1 Composite service...147 17.2 To configure a composite service...148 A NEtO, WebCT and NFM-P management comparison...151 A.1 Overview...151 A.2 Support for 9500 MPR management features across element managers...151 6 3HE-11997-AAAA-TQZZA

About this document Purpose Safety information Document support How to comment NSP NFM-P MPR User Guide describes how to discover, configure, and manage 9500 MPR devices including the 9500 MPRe, 9500 MSS-1c, and 9500 MSS-O variants using NFM-P. The guide is intended for network planners, administrators, and operators and is to be used in conjunction with other guides in NFM-P documentation suite where management of 9500 MPR devices does not differ from other network elements. Nokia recommends that you review the entire NSP NFM-P MPR User Guide before you attempt to use NFM-P to manage 9500 MPR devices. For your safety, this document contains safety statements. Safety statements are given at points where risks of damage to personnel, equipment, and operation may exist. Failure to follow the directions in a safety statement may result in serious consequences. Customer documentation and product support URLs: Customer Documentation Welcome Page Technical support Documentation feedback 3HE-11997-AAAA-TQZZA 7

8 3HE-11997-AAAA-TQZZA

Safety information 1 Safety information 1.1 Structure of safety statements 1.1.1 Overview This topic describes the components of safety statements that appear in this document. 1.1.2 General structure Safety statements include the following structural elements: CAUTION Lifting hazard SAMPLE Lifting this equipment by yourself can result in injury due to the size and weight of the equipment. Always use three people or a lifting device to transport and position this equipment. [ABC123] Item Structure element Purpose 1 Safety alert symbol Indicates the potential for personal injury (optional) 2 Safety symbol Indicates hazard type (optional) 3 Signal word Indicates the severity of the hazard 4 Hazard type Describes the source of the risk of damage or injury 5 Safety message Consequences if protective measures fail 6 Avoidance message Protective measures to take to avoid the hazard 7 Identifier The reference ID of the safety statement (optional) 3HE-11997-AAAA-TQZZA 9

Structure of safety statements NFM-P 1.1.3 Signal words The signal words identify the hazard severity levels as follows: Signal word DANGER WARNING CAUTION NOTICE Meaning Indicates an extremely hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Indicates a hazardous situation not related to personal injury. 10 3HE-11997-AAAA-TQZZA

What s new? 2 What s new? 2.1 Overview 2.1.1 Purpose This chapter highlights new features for NFM-P Release 17.0 and provides references to the specific feature content. Feature lists and high-level feature descriptions are also available in the NSP NFM-P Release Description. 2.1.2 Contents 2.1 Overview 11 2.2 What s new in NFM-P for 9500 MPR 11 2.2 What s new in NFM-P for 9500 MPR 2.2.1 What s new in NFM-P for 9500 MPR No new features are added in NFM-P for 9500 MPR. 3HE-11997-AAAA-TQZZA 11

What s new in NFM-P for 9500 MPR NFM-P 12 3HE-11997-AAAA-TQZZA

9500 MPR Overview 3 9500 MPR Overview 3.1 9500 MPR device support 3.1.1 9500 MPR Radio family The Nokia 9500 MPR is a microwave digital Radio family that supports PDH and Ethernet to migrate from TDM to IP. The 9500 MPR provides a generic, modular IP platform for multiple network applications such as 2G, 3G, HSDPA, and WiMAX to accommodate broadband services to Metro Ethernet areas. This solution improves packet aggregation, increases bandwidth and optimizes Ethernet connectivity. The 9500 MPR Radio family supports low, medium, and high capacity applications using ANSI and ETSI data rates, frequencies, channel plans, and tributary interfaces and has both indoor and outdoor applications. NFM-P also supports the native management of following variants of the 9500 MPR: 9500 MPRe The 9500 MPRe (also referred to as the 9500 MPR-SA) is the standalone, outdoor application of the MPT-MC and MPT-HCv2 ODU without a shelf unit. The 9500 MPRe provides fixed or mobile Ethernet site backhauling and supports converged MPLS metro networks. As a native NE, the 9500 MPRe appears on NFM-P maps and equipment managers. All standard SNMP-based features, including discovery and alarms, are supported with the same naming as the rest of the 9500 MPR family. Some features require a cross-launch of the NEtO external element manager. See 3.7 9500 MPR NEtO support (p. 24) for more information. NFM-P supports the native management of the following 9500 MPRe releases: 5.0, 5.1, 5.2, 6.0, 6.1, 7.0, or later. Note: From NFM-P perspective, the 9500 MPRe/MPR-SA (stand alone), and 9500 MSS-1c variants belong to same product family; both variants display on the &NFMPshort; GUI as the 9500 MPRe. However, for 9500 MPR software upgrades, the Label column allows you to distinguish between the 9500 MPRe/MPR-SA and 9500 MSS-1c variant types. 9500 MSS-1c The 9500 Microwave Service Switch-1c (MSS-1c) is an ultra-compact indoor unit (1/2 rack size) offering 10 E1 and 4 user interfaces. The 9500 MSS-1c provides user port interface, cross-connection, and switching management. The cross-connection matrix implements all the cross-connections between the User ports (4 Ethernet ports and E1/T1 streams) and the Radio port. The matrix is a standard Ethernet switch, based on VLAN, assigned by the MCT. NFM-P supports the native management of the following 9500 MSS-1c releases: 5.0, 5.1, 5.2, 6.0, 6.1, and 7.0. The NE backup and restore functionality for this node type 3HE-11997-AAAA-TQZZA 13

9500 MPR device support NFM-P is only supported for the following versions: 5.2, 6.0, 6.1, 7.0. A new backup and restore policy has been added to support this device type. You can access the policy from the Administration NE Maintenance Backup/Restore menu. Click on the Backup/Restore Policy tab, select the MPR-SA Default Policy and click Properties. Note this policy type requires the FTP/SFTP parameters to be configured. The following functionality is supported for the 9500 MSS-1c using NFM-P: automatic server registration with NE discovery ports listed in the Navigation equipment tree port alarm management automatic radio link discovery automatic node S/W download managed via a policy (same as the 9500 MPR/9500 MPRe) automatic node MIB backup and restore managed via a policy (same as the 9500 MPR/9500 MPRe) microwave backhaul service termination on the radio port 9500 MSS-O The 9500 Microwave Services Switch-Outdoor (MSS-O) is a compact, full outdoor microwave networking device, for boosting link capacity and reliability for small cell backhaul networks. The device provides both optical and electrical Ethernet interfaces and can be installed indoors or outdoors. You can configure the following on a 9500 MSS-O using NFM-P: three 10/100/1000Base-TX Ethernet interfaces, two with PFoE, and one optical Gigabit Ethernet SFP interface. See 10.3 To configure 9500 MPR Ethernet ports (p. 75) for more information about configuring Ethernet ports. Ethernet L2 LAGs. See 11.3 To create an Ethernet LAG on a 9500 MPR (p. 86) for more information about configuring Ethernet LAGs. synchronization on Ethernet ports. See 12.3 To configure synchronization on 9500 MPR Ethernet ports (p. 94) for more information about synchronization on Ethernet ports. port segregation. See 10.6 To configure 9500 MPR port segregation on an EAS module (p. 78) for more information about port segregation. microwave backhaul services. See Chapter 16, 9500 MPR service management for more information about how to configure microwave backhaul services. Note: Only the P2M VLAN path type is supported. Ethernet ring. See 15.1.3 Ethernet (G.8032) ring support (p. 111) for more information about configuring Ethernet rings. The LAG size for a 9500 MSS-O is restricted to the following: up to two LAG ports per NE, either Ethernet L2 LAG or Radio L1 LAG up to two electrical Ethernet ports per Ethernet L2 LAG. Ports can have PFoE enabled. ports 1, 2, and 3 on the 9500 MSS-O are available for Ethernet L2 LAG membership 14 3HE-11997-AAAA-TQZZA

9500 MPR card support 3.2 9500 MPR card support 3.2.1 Supported cards You can configure the following 9500 MPR device-specific cards: 1 Radio modem 1 STM (Channelized) 2 DS3 2 STM 2+2 Ethernet (EAS) 4+4 Ethernet (EAS) 32 DS1 32 E1 AUX alarm Core-B Core-ENH CorEvo EASv2 See Chapter 9, 9500 MPR shelf object configuration for detailed information of the supported cards and auxiliary equipment on 9500 MPR devices. Note: NFM-P, version 13.0 R3 and higher, allows you to discover all the EASv2 configurations supported on the 9500 MPR device. 3.3 Supported 9500 MPR device objects and auxiliary equipment 3.3.1 General information NFM-P supports the following 9500 MPR device shelves, objects, and auxiliary equipment: MSS shelves IDU and ODU basic and advanced fan trays LAG objects 3.3.2 Supported MSS shelf types The following MSS shelf types can be managed by NFM-P: MSS-1 shelf 3HE-11997-AAAA-TQZZA 15

Supported 9500 MPR device objects and auxiliary equipment NFM-P The MSS-1 is a 1-rack-unit, 1-slot shelf. The first four ports of this shelf are Ethernet ports. Ports 5 and 6 are SFP ports. The shelf also supports 16 DS1 or 16 E1 ports. Note: The equipment tree in NFM-P GUI displays the MSS-1 shelf as a card slot with Ethernet ports numbered from 1/1 to 1/6 and TDM ports from 1/7 to 1/22. Note: Radio LAGs (L1 and L2) are not supported. MSS-4 and MSS-8 shelves Slots 1 and 2 are reserved for core-enhanced cards. Each shelf requires a core-enhanced card in slot 1 and can have an optional spare card installed in slot 2 to protect the main card. The MSS-4 shelf supports cards in slots 3 and 4. A card in slot 3 can be protected by an identical card in slot 4. The MSS-8 shelf supports cards in slots 3 to 8. Protected cards must be installed in slots 3, 5, or 7 and are protected by optional identical cards in slots 4, 6, and 8, respectively. 3.3.3 IDUs and ODUs support The ODU is a microprocessor-controlled transceiver that interfaces the MSS with the microwave antenna. Each Radio modem card connects to one ODU. A 1+0 Radio modem protection scheme requires one Radio modem card and one ODU for each Radio direction. Two Radio modem cards and two associated ODUs must be provisioned in each Radio direction for the 1+1 protection scheme using NEtO. NFM-P can manage the following IDU and ODU variants: ODU300 The ODU300 transmitter consist of a cable interface, local oscillator, up converter/mixer, power amplifier, and a diplexer. The receiver consist of a diplexer, low-noise amplifier, local oscillator, down converter/mixer, automatic gain control, and cable interface. The ODU300 is frequency dependent. MPT-HCv2 The MPT-HCv2 ODU transports Ethernet traffic over an RF Radio channel between the MSS and the antenna according to the configured QoS and to the scheduler algorithms. The input interface is a standard Giga Ethernet interface (electrical or optical). The MPT-HCv2 is XPIC-ready by the installation of a dedicated module. The MPT-HC V2 is frequency dependent. MPT-MC The MPT-MC is similar to MPT-HCv2 from an architecture standpoint. The differences are: MPT-MC is medium capacity MPT-MC is natively Ethernet powered through a proprietary PFoE MPT-MC has an optical cable length limit of 100 m MPT-XP 16 3HE-11997-AAAA-TQZZA

Supported 9500 MPR device objects and auxiliary equipment The MPT-XP is a very high power version of the MPT-HCv2 and provides +7-8 db of additional transmit power as compared to equivalent MPT-HCv2. The MPT-XP is frequency dependent. MPT-HL The MPT-HL transceiver card is a microprocessor controlled RF transceiver that interfaces with the Core-E card or MSS-1 shelf MPT-HL port with an antenna. The MPT-HL transceiver microprocessor manages transmit and receive frequencies, transmit power, alarms, and performance monitoring. The MPT-HL transceiver resides in the MPT-HL shelf. The following configurations are supported: one or two Non-Standby (1+0) radios Hot Standby (1+1) and Hot Standby space frequency diversity MPT-HLC The MPT-HLC transceiver card is a microprocessor controlled RF transceiver that interfaces with the Core-E card, EASv2 card, or MSS-1 shelf MPT-HLC port with an antenna. The MPT-HLC transceiver microprocessor manages transmit and receive frequencies, transmit power, alarms, and performance monitoring. The MPT-HLC transceiver resides in the MPT-HL shelf. The following configurations are supported: one or two Non-Standby (1+0) radios Hot Standby (1+1) and Hot Standby space frequency diversity single-shelf repeater MPT-HLS The MPT-HLS is a fully indoor Radio system, for long haul and cabinet requirements, and transports Ethernet traffic over an RF Radio channel. The MPT-HLS transceiver is connected to an MSS-1, MSS-4, or MSS-8. The MPT-HLS can be connected to the core-enhanced card or to an EASv2 card. The MPT-HLS is a four-rack (2200, 2000, 1700, 1300 mm) unit with two RT subracks. The subracks can be hosted with up to 10 transceivers. The TRU (always protected) is located on the top of the ETSI rack. A fan subrack is configured for each RT subrack. Two types of fan modules are available for configuration, Fan 4 and Fan 8. See the 9500 MPR (Hardware) User Manual for more information about configuring the MPT-HLS Radio. NFM-P supports viewing the adaptive modulation values for the usage time 512 QAM and 1024 QAM in MPT-HLS. MPT-HQAM The MPT-HQAM outdoor unit is a microprocessor controlled RF transceiver that interfaces with the MSS-1/4/8/1c shelf; MPTACC, Core-E, P8ETH, and EASv2 card, or MPRe (standalone) with the antenna. Fixed and adaptive modulation schemes are supported. Channel frequency is software selectable within tuning range of the 3HE-11997-AAAA-TQZZA 17

Supported 9500 MPR device objects and auxiliary equipment NFM-P MPT-HQAM transceiver. The MPT-HQAM transceiver is frequency dependent. An MPT-HQAM connected to a Core-E, P8ETH, and EASv2 card requires a power source. The MPT-HQAM has integrated XPIC and RPS functions. NFM-P supports two operating modes in the MPT-HQAM: Standard mode The MPT-HQAM is used with its own capabilities and profiles. The air compatibility with another MPT-HQAM in Standard mode is supported. MPT-HC Compatibility mode MPT-HQAM is used with the MPT-HC capabilities and profiles. The air compatibility with another MPT-HQAM in MPT-HC Compatibility mode or with an MPT-HC is supported. The operating modes are configured on the NEtO and NFM-P supports viewing the MPTHC Compatibility parameter, with the values set to True or False, on the Radio General tab of the Physical Port (Edit) form. NFM-P supports viewing 1+1 protection configuration for: two MPT-HQAMs, both configured in Standard mode two MPT-HQAMs, both configured in MPT-HC Compatibility mode two MPT-HQAMs, one configured in Standard mode and one in MPT-HCv2 Compatibility mode one MPT-HCv2 (with the main role as protection) and one MPT HQAM configured in Standard or MPT-HC Compatibility mode one MPT-HQAM configured in MPT-HC Compatibility mode (with the main role as protection) and one MPT-HCv2 NFM-P supports the discovery of Radio L1 LAG by adding: MPT-HQAM in MPT-HC Compatibility mode to an L1 LAG of MPT-HCv2 MPT-HQAM in Standard mode to an LAG L1 of MPT-HCv2 MPT-HQAM in Standard or MPT-HC Compatibility mode to an L1 LAG of MPT-MC MPT-HQAM in Standard/MPT-HC Compatibility mode or MPT-MC to an L1 LAG of MPT-HQAM in MPT-HC Compatibility or Standard mode NFM-P supports the discovery of Radio L2 LAG by adding: MPT-HQAM in MPT-HC Compatibility mode to an L2 LAG of MPT-HCv2 MPT-HQAM in Standard mode to an L2 LAG of MPT-HCv2 MPT-HQAM in Standard/MPT-HC Compatibility mode to an L2 LAG of MPT-HQAM in MPT-HC Compatibility/Standard mode See the 9500 MPR ETSI (Hardware) User Manual for more information about configuring a Radio LAG. An MPT type conversion procedure allows the you to update an MPT-HCv2 to an MPT-HQAM on the node. For the complete procedure, see the 9500 MPR-A (Hardware) Maintenance and Trouble Clearing Guide. The node restarts after the conversion and NFM-P displays the updated MPT-HQAM on the equipment tree and the Port Usage parameter value in the General tab of the Physical Port (Edit) form. 18 3HE-11997-AAAA-TQZZA

9500 MPR statistics support 3.3.4 Fan tray support The 9500 MPR supports two fan tray types: basic and advanced. For the advanced fan tray, you can configure four ports for housekeeping alarms. See 9.3 To configure a 9500 MPR basic or advanced fan tray (p. 69) for more information about configuring a 9500 MPR fan tray. 3.3.5 LAG objects support NFM-P supports the following LAG objects on 9500 MPR (ANSI and ETSI) devices: L1/L2 Radio LAGs - You must use the NEtO external element manager to complete the initial LAG configuration prior to discovery by NFM-P. L2 Ethernet LAGs - You can configure and discover L2 Ethernet LAGs using NFM-P or NEtO. See Chapter 11, 9500 MPR LAG object configuration for more information about 9500 MPR LAG objects. 3.3.6 XPIC support The Cross-Polarization Interference Cancellation (XPIC) function doubles the capacity of a single frequency by using both horizontal and vertical electromagnetic polarizations on a path. This increases capacity while also saving spectrum and antenna costs. XPIC is required on two Radio interfaces in order to provide additional cross-polarization discrimination and to avoid co-channel interference. Only the MPT-HCv2/MPT-XP supports the XPIC function. See 10.7 To configure a power source for 9500 MPR card slots (p. 79) to configure power source type over Ethernet on a 2+2 Ethernet (EAS) card. See the 9500 MPR (Hardware) User documentation for more information about how to use the NEtO software to configure XPIC. 3.4 9500 MPR statistics support 3.4.1 Introduction NFM-P supports the collection of network performance, accounting, and flow-based statistics for 9500 MPR devices. NFM-P also provides statistics for monitoring NFM-P processes and functions. These statistics are typically used to monitor or troubleshoot a network, or to perform SLA or billing functions. Statistics collection can be configured with policies that are distributed to specified network objects. See NSP NFM-P Statistics Management Guide for information about the following for 9500 MPR devices: configuring statistics collection viewing statistics data in tabular or graphical form 3HE-11997-AAAA-TQZZA 19

9500 MPR statistics support NFM-P creating graphical representations of statistics data using the Statistics Plotter the supported performance and accounting statistic counters for 9500 MPR devices 3.4.2 Optimized historical statistics collection NFM-P collects historical statistics at 15 minutes and 24 hours intervals. The first set of statistics collected after a 9500 MPR device is managed contains all the historical statistics collected during that time interval. The subsequent historical statistics collected only contains the new statistics and the previously collected data is not duplicated. When the 9500 MPR device connectivity is lost, NFM-P collects all of the uncollected records upon restoration of connectivity. When the 9500 MPR device is unmanaged or suspended no new records are generated. The first set of statistics is collected after the 9500 MPR device is managed again. 3.4.3 9500 MPR specific statistic usage information The following provides notable statistic usage information that applies to 9500 MPR devices: The Total Transmitted Octets after Compression and Total Transmitted Octets after Compression Periodic statistic counters for Ethernet Aggregate Tx statistics have been added in NFM-P Release 13.0 R3, applicable for 9500 MPR, Release 5.2 and later. You can access these counters by selecting Properties on a 9500 MPR physical port, and selecting the Statistics tab. However, these counters also appear for earlier releases of the 9500 MPR and GNEs. Because the fields cannot be hidden, NFM-P sets the counter value to 0. NFM-P supports elaborated counters as an extension to the following classes: AggrMaintTxStats (for radio, Ethernet user ports, and L1 radio LAG) AggrPerQueueMaintStats (for radio ports) AggrMaintRxStats (for Ethernet user ports) The elaborated counters are applicable only to scheduled statistics and not on-demand statistics. NFM-P does not support real-time plotting of the elaborated counters. The elaborated counters are supported for 9500 MPR-E/A, 9500 MPRe, and MSS-1c devices from Release 5.2 and later. See the 9500 MPR performance statistics counters chapter in the NSP NFM-P Statistics Management Guide for detailed information about the individual statistics counters. The granularity period column displays the statistic collection period based on a set time interval, for example, 15 corresponds to 15 minutes and 24 corresponds to 24 hours. The radio interface performance management statistics are listed separately for collection intervals of 15 minutes and 24 hours at the port level. The following table lists the radio interface performance management statistics that are collected at the port level or using the Bulk Operations tool. 20 3HE-11997-AAAA-TQZZA

9500 MPR statistics support Radio interface PM statistic type Adaptive Modulation Current Data Frame Hop Current Data Frame Link Current Data RSL Hop Current Data TSL Hop Current Data Usage notes Statistic is only present when AM is enabled using Adaptive Modulation Mode. Always available for the Radio interface. Available for the Radio interface when RPS is enabled. See Note 1 and 2. Always available for the Radio interface. Always available for the Radio interface. RSL Link Current Data See Note 1 and 2. When RPS is present, Hop stats are enabled/disabled on the protecting port along with the active port. RSL Diversity Link Current Data RSL Diversity Hop Current Data Available for NE version 5.1 and later when the space diversity (combiner) is enabled on the Radio interface along with RPS. Available for NE version 5.1 and later when the space diversity (combiner) is enabled on the Radio interface. Note 1: When RPS is present, you can enable/disable statistics on the protecting port along with the active port. Note 2: When RPS is present, do not edit the Radio PM statistic parameters from NFM-P GUI for the spare protecting port. You can enable or disable performance management statistics at port level or using the Bulk Operations tool. Port level: You can enable or disable individual radio interface performance management statistics that are collected at intervals of 15 minutes or 24 hours. See 3.5 To configure radio interface performance management statistics at the port level (p. 22) for more information. Bulk Operations tool: You can perform bulk changes to enable or disable the applicable radio interface performance management statistics for statistics collection intervals of 15 minutes and 24 hours. The changes are applicable to the entire list of allowable statistics for statistics collection intervals 15 minutes and/or, 24 hours. See 3.6 To configure bulk changes for radio interface performance management statistics 3HE-11997-AAAA-TQZZA 21

To configure radio interface performance management statistics at the port level NFM-P (p. 23) for more information; also see the Bulk operations chapter in the NSP NFM-P User Guide for more information. Perform the following to plot the statistics for both ends of a Radio link traversing between two 9500 MPRs, between a 9500 MPR and a 7750 SR, or a 9500 MPR and a 7705 SAR: Select a supported Radio link on the Administration Physical Topology map, right-click on the link and choose Plotter New Plot. The Statistics Plotter window opens to display both link endpoints in the Monitored Object column. Select the appropriate Statistics Group, Statistics Counter, or Data Format and click the Record/Play buttons to plot the data. You can also plot Radio link statistics at the object level by selecting a supported device port in the navigation tree Equipment view, and choose Properties. The Physical Port Port (Edit) form opens. Click Plotter New Plot. The Statistics Plotter window opens to display the selected endpoint in the Monitored Object column. If the port is part of a Radio link, click on the Plot Other Endpoint(s) button to populate/view the other link endpoint. Select the appropriate Statistics Group, Statistics Counter, or Data Format parameters and click the Record/Play buttons to plot the data.see the NSP NFM-P Statistics Management Guide for more information about the statistics plotter. 3.5 To configure radio interface performance management statistics at the port level 3.5.1 Before you begin 3.5.2 Steps Configure the radio parameters using the MCT for the freshly brought up 9500 MPRe and 9500 MSS-1c devices, before configuring the radio PM enable and disable parameters on NFM-P. 1 2 On the equipment navigation tree, right-click on a 9500 MPR port where a Radio interface is configured, for example, an MPT-MC or MPT-HC card, and choose Properties. The Physical Port (Edit) form opens. Click on the Radio tab and configure the appropriate PM statistics parameter(s) on the Radio PM panel. END OF STEPS 22 3HE-11997-AAAA-TQZZA

To configure bulk changes for radio interface performance management statistics 3.6 To configure bulk changes for radio interface performance management statistics 3.6.1 Steps 1 2 3 Choose Tools Bulk Operations from NFM-P main menu. The Bulk Operations form opens. Click Create. The Create Bulk Change (New) step form opens. Configure the General parameters and click Next. The Specify the filter step appears. Note: For the Object Type parameter, select Radio Equipment - (radioequipment) Radio Port - (radioequipmentradioportspecifics). 4 Configure an appropriate filter and click Next. The Specify the attributes step appears. Note: Do not use the following attributes: Radio: Radio Port (Radio Equipment) Radio PM : Radio Port (Radio Equipment) Radio PM. The configured filter lists only the enabled radio PM statistics and not the disabled radio PM statistics. Radio: Radio Port (Radio Equipment) Radio PM : Radio Port (Radio Equipment) Radio Bulk Radio PM Enable/Disable 15 Min Radio: Radio Port (Radio Equipment) Radio PM : Radio Port (Radio Equipment) Radio Bulk Radio PM Enable/Disable 24 Hrs 5 Expand Attributes Radio Radio PM Bulk Radio PM Enable/Disable (24 Hrs or 15 Min). The Radio PM parameter panel appears. 3HE-11997-AAAA-TQZZA 23

9500 MPR NEtO support NFM-P 6 Choose either "Enable" or "Disable" for the Bulk RadioPM Enable/Disable (24 Hrs or 15 Min) parameter, click Next, click Finish, then close the wizard. The Bulk Operations form reappears. 7 8 9 Click Search to locate the Bulk Operation task, choose an entry, and click Properties. The Bulk Change (Edit) form opens. Click on the Batch Control tab and click Generate Batches. The batches are generated. Either click Execute All or choose the required entries and click Execute Selected to enable or disable PM statistics collection intervals of 24 hours and/or 15 minutes. Close the form. END OF STEPS 3.7 9500 MPR NEtO support 3.7.1 Element manager (NEtO) support You can install and cross-launch the 9500 MPR external element manager, the NEtO from NFM-P GUI; see 8.7 To cross-launch the NEtO from NFM-P GUI (p. 64) for information. For the 9500 MPRe, the NEtO cross-launch occurs only if the registration table entry has not reached the limit of 15 entries. The NEtO multi-version auto-download or cross-launch to each IPv6 node works when the nodes are reachable (IPv6 route must exist) from NFM-P Windows Client, from which the auto-download or cross-launch is being attempted. The cross-launch task of NEtO is listed in NFM-P user activity log. To view the task, choose Administration Security User Activity from NFM-P main menu. The log indicates whether the cross-launch was successful. The auto-download of NEtO occurs when NEtO is launched for the first time and this is not specifically listed in the log. 3.7.2 NEtO distribution through NFM-P NFM-P manages the distribution of the NEtO application and all related profiles. Any discovered 9500 MPR has all cross-launch paths automatically configured in policies so 24 3HE-11997-AAAA-TQZZA

9500 MPR NEtO support that no user configuration is required to use the NEtO. The cross-launch function also supports the option to run TACAS+ in the network, in which case NEtO has a NULL authentication when cross-launched, and the user is prompted for a user name and password. The first time a user cross-launches the NEtO, NFM-P Java Webstart installs the application on NFM-P client system. Any update to the NEtO installation files on NFM-P server results in an update to the NEtO installation on the client system. NFM-P supports the selection of user profiles to access the NEtO. The Admin NEtO launch, Viewer NEtO launch, and Default NEtO launch are listed in the scope of command roles that allows you to access the NEtO for a specific user profile. See the Appendix in the NSP NFM-P System Administrator Guide for the list of scope of command roles. See 8.6 To configure a scope of command role for NEtO access (p. 63) for information about configuring a scope of command role to access the NEtO for the required user profile. During an upgrade, NFM-P leaves property files in place for existing NEs, retaining any user edits made to support the NEs. An operator can change the property files to change the login behavior, as described in 4.7 To enable NFM-P management of 9500 MPR devices (p. 41). The Install Directory property is a property required only by NFM-P releases earlier than 10.0 R5; the current NFM-P release manages the NEtO installation. See the applicable 9500 MPR Release Notice for the supported versions of NEtO. 3.7.3 Service management with NEtO You can use the NEtO to manage services on the 9500 MPR. The use of an external element manager to change key network management information usually managed by NFM-P (such as service IDs, SAP or site information, or VLAN information) could result in data loss or corruption. To avoid this problem, site information is persisted so that management actions (such as moving service access from one DS1 port to another) do not result in data loss. On NFM-P, Release 13.0 R3 or later, configuration of the following can only be performed using NEtO: cards port usage Radio LAGs port and card protection NFM-P takes the following additional actions to accommodate service changes made using the NEtO: A move between ports by the NEtO generates an alarm. The new port attachment is discovered and the deleted port is retained. The user can copy provisioning information to the new port in NFM-P or manually reverse the change, if required. 3HE-11997-AAAA-TQZZA 25

WebCT NFM-P A move between Radio backhaul paths by the NEtO generates an alarm and is accepted. The alarm message retains the old and new path information, allowing the user to change the service back to its original form, if required. A move between Radio and Ethernet backhaul paths by the NEtO generates an alarm and is accepted. The alarm message retains the old and new path information, allowing the user to change the service back to its original form, if required. When using NEtO to change VLAN IDs for a service, the new service is discovered and alarms are generated for both services. An informational alarm is generated for the new service, and a major alarm is generated for the old service. A clean up on the service deletes all new discovery alarms and old SAPs, and accepts the new SAPs. Service changes from the NEtO are not supported for ERPS (Radio or fiber). 3.8 WebCT 3.8.1 Overview WebCT is the web interface for 9500 MPR devices using the CorEvo card. WebCT provides configuration information, alarms, monitoring and administration functions. See the 9500 MPR WebCT User Manual for more information about WebCT. 3.8.2 Open WebCT from NFM-P NFM-P supports the cross-launch of WebCT from the equipment navigation tree and the topology map. 3.9 To open WebCT from NFM-P 3.9.1 Steps Note: The external EMS browser is supported on the latest release of Firefox, IE, Chrome, and Safari. 1 2 Choose Equipment from the navigation tree view selector. The navigation tree displays the Equipment view. Right-click on a 9500 MPR device that has a CoreEvo and choose Launch External EMS Browser. The WebCT main view screen appears in the secure mode (https) or normal mode (http) depending on the 9500 MPR device configuration. END OF STEPS 26 3HE-11997-AAAA-TQZZA

Workflow to manage 9500 MPR devices 3.10 Workflow to manage 9500 MPR devices 3.10.1 9500 MPR workflow sequence The following workflow describes the high-level tasks required to commission and discover 9500 MPR devices, configure and manage the device objects, and configure and manage the policies and services associated with the device. 3.10.2 Process 1 2 3 4 5 6 7 Review the workflow to prepare NFM-P to perform network management of devices in the NSP NFM-P User Guide before starting this workflow. The steps in this workflow are common to all NFM-P-managed devices. Commission 9500 MPR devices for NFM-P management; see Chapter 4, 9500 MPR device commissioning and management. Use NFM-P to discover 9500 MPR devices; see the Discovering devices using the NFM-P chapter in the NSP NFM-P User Guide. View, manage, and configure 9500 MPR device network objects as required; see the Working with network objects using the NFM-P chapter in the NSP NFM-P User Guide. View, manage, and configure 9500 MPR device objects; see Chapter 8, 9500 MPR object configuration. View, manage, and configure 9500 MPR device LAG objects; see Chapter 11, 9500 MPR LAG object configuration. Modify 9500 MPR device shelf objects; see Chapter 9, 9500 MPR shelf object configuration. You can configure cards only using NEtO. See the 9500 MPR (Hardware) User Guide for more information. 3HE-11997-AAAA-TQZZA 27

Workflow to manage 9500 MPR devices NFM-P 8 Modify ports on 9500 MPR devices, as required; see Chapter 10, 9500 MPR port object configuration. You can configure ports only using NEtO. See the 9500 MPR (Hardware) User Guide for more information. 9 10 11 12 As required, perform bulk configuration changes on 9500 MPR devices to change the same configuration on multiple objects at the same time; see the Bulk operations chapter in the NSP NFM-P User Guide for general guidelines. For example, configure a bulk change by choosing 9500 MPR System Settings - (mpr.mprneproperties) in the Object Type drop-down menu to specify the bridge type for all 9500 MPR devices. See the NFM-P-O XML Reference for information about all bulk change XML classes associated with the 9500 MPR objects. Create NFM-P policies that define the conditions for NFM-P management functions on 9500 MPR devices. a. Before creating policies for 9500 MPR devices, review the Policies overview chapter in the NSP NFM-P User Guide for information about NFM-P policy management and the workflow on how to create and distribute policies. b. Create QoS device-specific policies as required for 9500 MPR devices; see Chapter 14, 9500 MPR QoS policies. Before configuring backhaul, or composite services and related functions on 9500 MPR devices; perform the following as required: a. Review the Service management and QoS chapter in the NSP NFM-P User Guide for information about configuring services on 9500 MPR devices using NFM-P. b. Review the Customer configuration and service management chapter in the NSP NFM-P User Guide for information about, and workflow on, how to create and manage customers and the services they subscribe to. As required, create customer profiles. c. Review the 9500 MPR service management and service tunnels chapter for specific information on supported service types; see Chapter 15, 9500 MPR service tunnels. d. Configure service tunnels to carry service traffic on 9500 MPR devices; see Chapter 15, 9500 MPR service tunnels. Configure bachkaul services for subscribers connected to 9500 MPR devices; see Chapter 16, 9500 MPR service management. 28 3HE-11997-AAAA-TQZZA

Workflow to manage 9500 MPR devices 13 Configure composite services to connect the types of services for subscribers connected to 9500 MPR devices; see Chapter 17, 9500 MPR composite service. 14 Monitor and acknowledge incoming 9500 MPR-specific alarms to check the type and characteristics of the alarms, and to resolve the network problems or physical equipment failures identified by the alarms; see the Alarm management overview chapter in the NSP NFM-P User Guide for more information. In addition: Click on the Abnormal Conditions tab of the Network Element (Edit) form to check for the abnormal conditions on the 9500 MPR such as loopback or TxMute conditions to determine the appropriate corrective action. In previous releases of NFM-P, each abnormal condition on the 9500 MPR were reported as an individual alarm on the Faults tab. Abnormal conditions are now reported as a single alarm. Refresh the Abnormal Conditions tab to ensure the latest content is displayed. Clear the abnormal condition alarm after all the individual abnormal conditions are cleared. 15 Perform specific 9500 MPR device maintenance functions as required: on-demand or scheduled NE configuration backup and restore device configurations perform a 9500 MPR device on-demand software upgrade. See Chapter 5, 9500 MPR software upgrade monitor deployment of configuration changes to 9500 MPR devices configure the OLC state on a 9500 MPR device object to specify whether the object is in maintenance or in-service mode to filter alarms in the alarm window perform daily, weekly, monthly, and supplemental routine maintenance to maintain hardware and system integrity and efficiencies of 9500 MPR devices See the NSP NFM-P System Administrator Guide for more information. 16 Collect NFM-P and NE statistics to monitor NFM-P and 9500 MPR devices, network and service performance, compile equipment usage and billing data, and ensure SLA compliance; see the NSP NFM-P Statistics Management Guide. 3HE-11997-AAAA-TQZZA 29

Workflow to manage 9500 MPR devices NFM-P 30 3HE-11997-AAAA-TQZZA

9500 MPR device commissioning and management 4 9500 MPR device commissioning and management 4.1 General description 4.1.1 General description The 9500 MPR requires commissioning and device-specific pre-configuration before NFM-P can discover and manage the device. See the 4.3 Workflow to commission and manage 9500 MPR devices (p. 37) for the sequence of high-level tasks required to commission a 9500 MPR before discovery by NFM-P. The 9500 MPR requires two mediation policies be created manually as part of the discovery rule creation process: one for Read-Write mediation and a Trap mediation policy. Note: While creating the read/write mediation policy, you must select FTP for the File Transfer Type, and specify the FTP User Name 'ftp' and FTP User Password 'ftp'. While creating the trap mediation policy, you must specify 'SNMP-trap' as the SNMP v1/v2c Community String. Note: To determine which version of the 9500 MPR NEs and variants are supported by NFM-P, see the NSP NFM-P and 5620 SAM Network Element Compatibility Guide for information. 4.2 9500 MPR management 4.2.1 Supported management traffic types A 9500 MPR device requires pre-configuration before NFM-P management of the device is possible. NFM-P supports in-band and out-of-band management of devices. When you configure in-band management only, management traffic between NFM-P and a 9500 MPR is transmitted through any port that is configured for network access, but not the management port. Using in-band management, NFM-P sends management traffic to the system IP address of the device, or to an optional L3 management interface. When you configure out-of-band management only, management traffic between NFM-P and a 9500 MPR is transmitted through the management port of the device. Using outof-band management, NFM-P sends management traffic to the management IP address of the device. See the NSP NFM-P User Guide for more information about device bandwidth management. 3HE-11997-AAAA-TQZZA 31

9500 MPR management NFM-P Note: A 9500 MPR device can only be managed by up to five instances of NFM-P. In-band management of 9500 MPR devices To enable 9500 MPR in-band management, NFM-P requires connectivity to the 9500 MPR NE, as shown in Figure 1, Example of 9500 MPR in-band management (p. 31) and described in the associated example configuration steps. Ensure that the trap receiving interface on NFM-P server is configured with the IP address of the in-band NIC that connects to the 9500 MPR network. Figure 1 Example of 9500 MPR in-band management 9500 MPR network NFM-P Server 2.2.2.1 Switch or Router 9500 MPR A Management (TMN) port: 2.2.2.2 Local IP: 10.10.3.5 9500 MPR B Local IP: 10.10.3.9 20511 Perform the following initial configuration on the 9500 MPR: 1. Connect the first 9500 MPR Node 1 to the switch using the TMN port or port 4 of the 9500 MPR A. When NFM-P is connected to the 9500 MPR network via non-9500 MPR devices like the 7705 SAR or 7750 SR, expect that the TMN in-band feature is enabled on Node 1 of the 9500 MPR that is connected to non-9500 MPR devices. For example, NFM- P-----7705SAR_1/1/1-----port1/4_MPR1 -------(Radio)------MPR2... In the preceding example, the 9500 MPR Node 1 and port 1/4 are enabled with VLAN ID and IP addresses and the 7705 SAR is configured with the same VLAN and IP address from the same subnet. 2. Ensure that the Radio links between the 9500 MPRs are working by pinging the local IP addresses. A connection between two 9500 MPR NEs could be over an Ethernet or optical link. If the core Ethernet or core optical port is used between two 9500 MPRs, the ports should be enabled with TMN in-band on the 9500 MPR. 32 3HE-11997-AAAA-TQZZA

9500 MPR management Note: The management port IP, TMN in-band IP, and local IP can be in different subnets. Perform the following network configuration: 1. Verify that you can ping the local IP address of all the NEs from NFM-P server. 2. Verify that you can ping NFM-P server IP address from each of the 9500 MPR NEs. Note: You can manage the 9500 MPR through the local IP address even though the management interface vinfm-p server is not reachable. 3. NFM-P should be able to discover and manage the local IP addresses of the 9500 MPRs after connectivity is established between NFM-P and the 9500 MPR NEs. 4.2.2 LAC management of 9500 MPR devices Introduction NFM-P provides a Local Access Control (LAC) management synchronization mechanism to allow or deny (inhibit) user-access to configure 9500 MPR devices using a Local Craft Terminal (LCT). This prevents multi-write access sessions on 9500 MPR devices. You can also enable or disable if NFM-P receives LAC alarms from the nodes. Enable LAC management You can enable LAC management by configuring the Enable LAC Management parameter on the MPR tab of the Administration System Preference System Preference form. Enabling LAC management automatically denies LCT access to nodes that are newly managed only. There is no impact to existing managed 9500 MPR nodes. After the Enable LAC Management parameter is configured, you can enable or disable LAC alarms by configuring the Enable LAC Alarms parameter on the MPR tab of the Administration System Preference System Preference form. NFM-P generates a LAC requested alarm indicating LCT use is requesting access to the node. If disabled, no new alarms will be generated going forward. The Enable LAC Alarms parameter cannot be configured if the Enable LAC Management parameter is disabled. Note: The Enable LAC management parameter is disabled by default. Therefore, the LAC state of any node which is newly managed by NFM-P going forward will not be altered. This is done to allow LCT access for those users who normally provision the 9500 MPR using NEtO or the 1350 OMS. LAC management status of a 9500 MPR device You can configure the LAC management status of a 9500 MPR device at the node level by selecting the node in the navigation tree Equipment view, and choose Properties. The Network Element form opens. Click on the System Setting tab and verify the LAC state parameter in the LAC configuration panel. You can re-configure the LAC state parameter if required; any changes made at the NE level and will only affect that NE. 3HE-11997-AAAA-TQZZA 33