Olympus BX43_46 Installation Instruction (OEM Adjust) 4

Similar documents
Olympus BX43 and BX46 Installation Instruction for Microscope End Users (easy install version) 4

Included Items Not Shown:

Microscope with original illuminator. Microscope with Nanodyne replacement illuminator.

Original Zeiss Axiovert Illuminator. Nanodyne Replacement Illuminator for Zeiss Axiovert

Nanodyne Replacement Illuminator for Zeiss Axiovert Microscope Installation Instructions

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

E1135C PDU and Pod Upgrade Procedure

Richter Optica. Instructions for Model: HSX1 High School Microscope

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Solid State Control Calibration Procedure MKG Solid State Griddles - All Options

Plasma Panel Replacement Guide DU-42PX12X

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

CAMERA ASSEMBLY. Removal/Replacement of the Camera Box Assembly APR-CA. Install Camera Assembly. Remove Camera Assembly

Installing a Power over Ethernet injector

HDMI Upgrade for the Showcase DVD

SERIES 5 TABLES/BENCH

imac Intel 21.5" EMC 2389 Stand Replacement

Written By: Brittany K

Power Cable. Low-Voltage Cable

Yamaha DX7 LCD Installation Guide

SP-100. Service Manual Aug. 02

Canon Powershot A70 Button Flex Assembly Replacement

Memory Expansion for DriveLogix Controller

Upgrading the programmer supply unit of the BeeProg+/BeeProg2 programmer

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Written By: Walter Galan

Electronic Balance Ionizer STABLO-AP Service Manual

Replacing the Power Supply

Upgrading a 2U CHP to an i7 Quad Core SBC

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Written By: Walter Galan

Removing the Battery. 2.Disassembly. Disassembly. Figure 1 Battery Removal. Removing the Battery 2-5

Megatouch FORCE Monitor Chassis Board Replacement

RSL PSM-2 Power Supply Module Project: Modifying a FlatCap2

Toshiba Satellite A105-S4011 Touchpad

Toshiba Satellite A210 Fan Replacement

Mac Mini Mid 2010 SSD Installation

V910 Kit. Hardware Installation Guide. P/N Revision: A

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

GPIB-232CT-A IBCL EPROM Installation Guide

Motorola Moto Z2 Play Audio Jack Replacement

ASUS D550MA-DS01 Motherboard

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

Figure 4-29 Removing the CPU compartment cover

Toshiba Satellite A210 Motherboard

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Written By: Sam Lionheart

View Wall Interface. Dynamic Glass INSTALLATION GUIDE. Description. System Requirements. Installation Overview

Huawei P9 Display Assembly with Frame Replacement

Encore XT Manual Gun Upgrade Kit

OMM200 and OMM200T. Metallurgical Microscope

L-80 SERIES HOME & COMMERCIAL HIGH-TECH ENTERTAINMENT CENTER DIAGNOSTIC ADDENDUM

Single cable kit for the FCB1010

Xbox 360 Motherboard Replacement

MAGIXBOX TM. Quick Start Guide

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013

Written By: Patrick. Disassembly to clean dust from the fan and heat sink. HP Pavilion G6 disassembly for cleaning

Reflowing Xbox 360 Motherboard

Dell Inspiron E1705 Motherboard Replacement

Upgrading LVDS Cables Instruction Sheet

Written By: Sydney Dye

Skullcandy Air Raid USB Board Replacement

C202SA: Disassembly Guide

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Validator Update Instructions for Rowe BC1200 $1 - $20

Retina MacBook 2016 Display Assembly

Canon EOS 70D Camera Motherboard

WARNING ELECTRICAL SHOCK HAZARD

Mi50 Inverted Microscope User s Manual. Fein.

OnePlus 5 Screen and Digitizer Assembly Replacement

ASUS D550MA-DS01 Screen Replacement

Series 3700 Screw Terminal Assemblies Installation Instructions

How to assemble and disassemble Anafi

Canon EOS Rebel T2i Top Cover Replacement

Xbox One Wireless Controller Bottom Motherboard Replacement

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Retina MacBook 2015 Lower Case Assembly Removal

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Arecont Vision MegaDome Installation Manual

MacBook Core 2 Duo Display Replacement

Mounting DIGITAL DISPLAY

IPhone 7 Plus Chargeport REPAIR GUIDE. Version Edition

Motorola Moto G4 Plus Motherboard Replacement

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

Retina MacBook 2015 Display Assembly

imac Intel 21.5" EMC 2428 SSD Dual Drive

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427

Nikon D5000 Viewfinder Replacement

SPARE PARTS & HOW TO HANDLE. μ-icc 2.45 compact. - Instructions - S/N: A01-PG10-SPE Version No.: 0 V

MacBook Pro 17" Unibody AirPort Board Replacement

M40 Microscope User s Manual

Portable Gas Monitor (PGM-IR) Infrared Sensor Replacement Instruction

A Backlighted LCD for your K1

Olympus Stylus 1030 SW Camera Lens Replacement

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Transcription:

Olympus X_6 Installation Instruction (OEM djust) If you are not an experienced repair tech please consider the alternate (easy install) version dditional Items Included ut Not Shown: PN 07 Olympus X Illuminator ssy PN 077 Hex Key mm PN 060 Hex Key mm M VH tape PN 05 Pot-Plate-Cable ssembly PN 0 SHCS M x 0.7 x 0mm PN 07 Power Supply - XP Power 5V Fixed lade US Input/US Output PN 07 Cable ssy.5mm ID x.5mm OD R plug to US 6 foot The illuminator may be powered by plugging the cable into the power supply provided, or into a suitable US port on a computer or other device. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Power supplies are subject to substitution without notice due to availability issues and changes in regulations. Pot Knob (save original from microscope) Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF

Step : Place the microscope upside down, unplug the existing X illuminator cable, and unscrew the existing illuminator unit from microscope port as shown, using the mm hex key provided. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF

Step : Disassemble back cover. Note that after installation of the Nanodyne illuminator, there should be no power connections left in place to the DC power inlet (red circle). ** Safety and misc. ** The original illuminator circuitry (red arrow) is completely replaced by the Nanodyne equipment which is powered by a universal input wall plug power supply with low voltage DC output. Regardless whether the original circuitry is left in place or removed, be sure there is no possibility of electrical hazard in case an unfamiliar user connects power to the old DC input. The original circuitry may be left in place, or removed as it is no longer used. We recommend removing the power cable from the DC input connector. It should be cut short so there is no possibility it could be connected to the original circuitry, or insulated with heat shrink tubing or electrical tape. Han-Seung Yang //09 Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF

Step : Pull out original pot cable from the existing cable ties (red circles). Unscrew using mm hex key and pull out the base unit as shown above. Step : Unscrew and pull out the base cover as shown in left. Han-Seung Yang //09 Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF

Step 5: Lift up the iris diaphragm cover (it is taped as shown), unscrew and pull out the iris diaphragm unit, and remove another piece of taped cover from the base unit as shown in left. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) 5 OF

Step 6: Open the front panel, disconnect pot cable as shown, and remove the knob from the pot. Unscrew original PC panel as shown below. Save the screws. of them will be needed to attach the Nanodyne pot plate. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) 6 OF

Step 7: Remove the original PC panel and pot cable as shown above. Place Nanodyne Pot Plate Cable ssembly using of original screws, then reinstall original Pot Knob (saved from existing system) as shown below. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) 7 OF

Step 8: Cut small pieces of M VH tapes, attach to the back sides of the LIM and SET buttons, then put them back in the original places. They are now just used to cover the holes. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) 8 OF

Step 9: Reinstall front panel and secure the cables as shown above with the existing tie wraps, to keep the cables out of the moving parts of the microscope, and the optical path from the illuminator. Insert black rubber guide (red circle) to the right place and attach the original taped cover from the base unit as shown in left. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) 9 OF

Step 0: Reinstall the iris diaphragm unit using original hex screws as shown above and attach the original taped iris diaphragm cover as shown in left. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) 0 OF

Step : Insert and secure the base unit using original hex screws as shown above. Place the bottom cover and make sure all the original circuitry cables are disconnected (red circles) as shown in left. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF

Step : Reinstall the back cover, insert PN 0 hex screw (red circle) to the screw hole of the Nanodyne adapter as shown above, and insert Nanodyne illuminator unit to the microscope port. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF

Step : Tighten the hex screw to secure Nanodyne illuminator in place, connect the pot cable, and secure the cables as shown in left (using M VH tape if needed). Plug C adapter to the Nanodyne illuminator and now it is ready to use. *Note: The detailed Pot Cable insertion procedure to the TPI Main ssy will be shown in next page. Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Tape to secure wires. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF

efore Insertion Partial Insertion Connect the socket at the end of the Pot Cable ssembly to the mating socket of the illuminator, as shown in the pictures on this page. fter partially inserting the socket to the mating socket of the illuminator with your finger, use other mechanical tools such as driver or tweezer to firmly insert the socket all the way by pushing back edge of the socket as indicated with the red arrow in the image (top right). The socket cannot be fully engaged by pushing on the wire attached as the wires would just collapse. If you want to pull the socket out, pull the wire straight out by firmly gripping the black heat shrink tubing. Full Insertion Copyright 07 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Han-Seung Yang //09 PN 08 Olympus X_6 Illuminator System Installation (OEM djust) OF