HARNESS INFORMATION TECHNICAL DOCUMENTATION

Similar documents
Serial Data DIN Fiber Link System

Two 16 Bit Registers, One for Integer Display One for Floating Point.

GENSYS 2.0 GENSYS 2.0 CORE GENSYS 2.0 LT

paralleling SOLUTIONS

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL

ICF-1150 Series Quick Installation Guide

ETOR-4. Ethernet/Serial Gateway USER MANUAL

GENSYS 2.0. All-in-one genset control and paralleling unit with integrated PLC. Part Number: A53 Z J-En. Last Update: 13/06/2011

YOUR EXPERT IN GENERATOR SOLUTIONS. NEW GENSYS/MASTER 2.0 Range V5.03 Firmware. NEW CRE Config V2.80 SOFTWARE

PF MODBUS REGISTER MAP. v1.4 Revised Nov 29, 2016

DTM Distributed Transmitter Monitor

INDUSTRIAL ETHERNET MODULE TBOX Manual

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

itrax Remote Display

DEEP SEA ELECTRONICS PLC DSE8005 SCADA Suite PC Software Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

RXTH DUAL ROOM SENSOR / SWITCH

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

GENSYS 2.0 RANGE. All-in-one generating set control and paralleling unit. Technical documentation

MED102A. Industrial Serial to Single-mode Fiber Converter

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Graphical logic editor for GENSYS 2.0 and MASTER 2.0 family. Technical Documentation. Part Number: A70 Z D-En

Version 1.0c May 6, 2010 ATK3

RDM172 Remote Display Module QUICK GUIDE

RXTP ROOM TEMPERATURE

ICF-1150 Series Quick Installation Guide

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

Features and Benefits. Certifications

GENSYS CORE. Technical Documentation. Core unit for all-in-one. Genset control and paralleling unit. with integrated plc. Chapter : Overview

IntesisBox Modbus Server - Honeywell XLS 80

IntesisBox Modbus Server M-Bus

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

TCF-142 Quick Installation Guide

Voltage regulator TAPCON 260

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

ASTAT XB/XBm Remote Operator

Genset control and protection with safety system

Carbon Monoxide Sensor - ModBus

Manual# Installation Manual. 400E Series. DCU 410E Engine Control Unit RP 410E Remote Panel

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

Replacement of GCP-10 Series with easygen-1500 Application Note

RS485 MODBUS Module 6RO

MIC-2 Multi-instrument DATA SHEET

Extension module for BACnet over Ethernet / IP and graphic Web functions

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

MIC-2 MKII, Multi-instrument DATA SHEET

4 Connection and interface

-C5RS-LC RS232 EXTENDER

IntesisBox Modbus Server KNX

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Wiring Instructions for Replacement of 2301A Load Sharing and Speed Controls with 2301D Load Sharing and Speed Controls

RS-FS-N01 Wind speed transmitter user's Guide (485type)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

State-of-the-Art Technology

Features and Benefits. Certifications

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

CHAPTER 1 INTRODUCTION

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM Revised 4/30/ Electrical Systems

quick start guide Carel EVD Evolution MODBUS Device E2 Setup for

POWERWISE INDAC SETUP MANUAL

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

Wiring Guide EP.HIO. Version 1.03 Last Updated:

4 Channel Contact Closure DIN Fiber Link System

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

MODBUS-IN. Modbus Card. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

JVA Z Series Keypad Bus Wiring Installation Manual

Motor Controller Cooling System (MCCS) Maintenance Manual

AirCare General Purpose ModBus Interface ACM1001. OptiDrive Modbus Module Product Specification. For assistance call

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

DNP3 Protocol (Serial)

8 Channel Contact Closure DIN Fiber Link System

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

ECLYPSE Communication Modules

easygen-3000 Series (Packages P2) Genset Control

I-7570 Serial To HART Converter

TG Technical specifications

L5351 DeviceNet Communications Interface

IIOT Cloud Solution Intelligent Starter Kit by App(i OS/ Android) EX9017M+EX9486CW-MTCP+APP(i OS/ Android)+EX Cloud

Power & Communication Cables

Installation Manual rev

L5353 Profibus-DP Communications Interface

Dip Switch settings for 2-wire and 4-wire configuration. Schneider Electric - Division - Name Date

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Extension module for graphic Web functions for one automation station

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

Transcription:

HARNESS INFORMATION TECHNICAL DOCUMENTATION Part Number: A53 W0 9 0002-B-EN Last Update: 05/2018 CRE Technology believes that all information provided herein is correct and reliable and reserves the right to update at any time. CRE Technology does not assume any responsibility for its use. E & O E.

NOTE Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or servicing this equipment. Apply all plant and safety instructions and precautions. Failure to follow instructions can cause personal injury and/or property damage. Motors, turbines and any other type of generator must be equipped with protections (overspeed, high temperature, low pressure depending on the power plant). Any changes of the normal use of the equipment can cause human and material damage. For further information, please contact your CRE Technology distributor or the After-Sales Service Team. All CRE Technology products are delivered with one year warranty, and if necessary we will be happy to come on site for product commissioning or troubleshooting. The company also provide specific trainings on our products and software. Technical Support: +33 492 38 86 86 (office hours: 8.30AM-12AM / 2PM-6PM GMT+1) Mail: support@cretechnology.com Skype: support-cretechnology.com i INFORMATION You can download the up-to-date version of this documentation and different other documentations relating to GENSYS 2.0 on our web site: http://www.cretechnology.com/

Harness information Technical documentation TECHNICAL DOCUMENTATION HISTORY DATE VERSION COMMENTS Nov. 2012 A Initial version Oct. 2016 B Addition of GENSYS COMPACT and optic fiber information May. 2018 C New product design (GENSYS COMPACT & GENSYS COMPACT CORE) NOTE i Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or servicing this equipment. Apply all plant and safety instructions and precautions. Failure to follow instructions can cause personal injury and/or property damage. Contact your CRE Technology distributor for course training.

RANGE OF WIRING HARNESS REFERENCES OVERVIEW A53W1 ETHERNET CROSS CABLE CAT 5 A40W2 CAN, RS485 A40W3 CAN, RS485 A40W4 CAN, RS485 A40W5 CAN A40W8 CAN, RS485 A53M0 OPTIC FIBER CONVERTOR Multimode ST/ST A53M1 OPTIC FIBER ST/ST Multimode 100 meters Temp : -25 +75 C PVC : avoid contact with fuel

Harness information Technical documentation WIRES 2 WHITE-BLUE STRIPE = CAN L 7 BLUE-WHITE STRIPE = CAN H 3 WHITE-GREEN STRIPE = CAN GND 4 GREEN-WHITE STRIPE= RS485 GND 5 WHITE-ORANGE STRIPE= RS485 Rx 6 ORANGE-WHITE STRIPE= RS485 Tx WIRING HARNESS FOR GENSYS 2.0 GENSYS 2.0 PC (Ethernet) GENSYS 2.0 GENSYS 2.0 (CAN Bus) A53W1 (Ethernet) CROSS CABLE CAT 5 Enable 120Ω termination resistor Phone : + 33 (0)4.92.38.86.82 - www.cretechnology.com - info@cretechnology.com

GENSYS 2.0 GENSYS 2.0 GENSYS 2.0... (CAN Bus) 120 Ω resistor integrated = No need to activate the GENSYS 2.0 termination How many cables do you need? REFERENCES REQUIRED QUANTITY COMMENTS A40W3 Total number of GENSYS 2.0 & MASTER 2.0 units - 2 A40W4 Total number of GENSYS 2.0 & MASTER 2.0 units - 3 A40W2 2 One to each end of the CAN Bus GENSYS 2.0 GENSYS 2.0 MASTER 2.0 (CAN Bus) 120Ω resistor integrated = No need to activate the GENSYS 2.0/MASTER 2.0 termination

Harness information Technical documentation GENSYS 2.0 REMOTE I/O (CAN Open) 120Ω resistor integrated = No need to activate the GENSYS 2.0 termination GENSYS 2.0 CORE RDM 2.0 Ethernet (COM4) A53W1 (Ethernet) CROSS CABLE CAT 5

WIRING HARNESS FOR GENSYS COMPACT OR FOR AMF COMPACT GENSYS COMPACT / AMF COMPACT PC (ETHERNET) A53W1 (Ethernet) CROSS CABLE CAT 5 GENSYS COMPACT GENSYS COMPACT (CAN Bus) A40W4 * 120Ω internal end line resistor activated by shunt between CAN H and RES * 120Ω internal end line resistor activated by shunt between CAN H and RES

Harness information Technical documentation GENSYS COMPACT GENSYS COMPACT GENSYS COMPACT... (CAN Bus) A40W4 A40W4 * 120Ω internal end line resistor activated by shunt between CAN H and RES * 120Ω internal end line resistor activated by shunt between CAN H and RES GENSYS COMPACT / AMF COMPACT REMOTE I/O (CAN Open) Shield- Drain GENYS COMPACT CAN 2

CONNECTION WITH OPTIC FIBER OPTIC FIBER MANAGEMENT OPTIC FIBER CONVERTOR Multimode ST/ST: P/N: A53M0 OPTIC FIBER Multimode ST/ST 100 meters: P/N: A53M1 Other lengths: on request. OPTIC FIBER - Single CAN Network OPTIC FIBER OPTIC FIBER - Multiple CAN Network (different baud rates) CAN Bus Depend on baud rate OPTIC FIBER CAN Bus Depend on baud rate Up to 60 km

Harness information Technical documentation CONNECTION WITH BSD 2.0 GENSYS (2.0 or COMPACT) BSD 2.0 WAN (Internet) or GSM/GPRS (carte SIM) MODBUS RTU or MODBUS TCP A40W4 (RS485) for GENSYS 2.0 only

EXPERT IN GENERATOR solutions www.cretechnology.com www.cretechnology.com PARALLELING SOLUTIONS_EN_A2017