AIR Compressor. Efficient Cooling System. PCG Series 01/02

Similar documents
IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Performance and Efficiency

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)

Ver.1.1. subject to be changed without prior notice

Compressor Controller MAM 890

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

Digital Overhead Stirrer

Oil Free Scroll. Air Compressors

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

U-Match Series DC Inverter Service Manual PRODUCT

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

ES 4000 STANDARD. 1 General information Document Overview General description Introduction... 4

Slim duct (AMTTTFNLDEH ) Indoor units

CFM-9225V XX - CXX

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

SmartAir Master. The intelligent compressed air management system Developed by Compair to save your customers money

Model QRS CPVS

NIR Moisture Analyzer KB-30

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Conductive Level Controller

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

The Rogers QNW HP Series is a state-of-the-art, high pressure compressor for service applications requiring high pressure.

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller

07. har-link Interface Connectors

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Provided services catalogue

Voltage Current Front-mounting bracket

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Shenzhen VTdrive Technology Co.,Ltd.

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Stainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

Manual Vibration Meter PCE-VT PCE Instruments

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Motor Controllers. On-Road AC Motor Controller. Model 1239E.

Temperature controller Ducted systems

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

Easy interface A large monitor, comprehensible interface allow getting any information required, or setting up the control system.

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

QLC(Y) SERIES EMERGENCY FIRE FIGHTING WATER SUPPLY EQUIPMENT

Siemens Industrial s

W Economic: Can be installed quickly and efficiently. W Compact and versatile: Top technology for limited

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Gardner Denver / Tamrotor Enduro 12 Rotary Screw Compressor, with Adaptable Compressor Speed, designed to produce more gas flow per bhp.

External level devices for conductive point level switch

MAJOR VA Power Inverter

Reliability and extended operation

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

POWERLINK Motor Test (Eddy Current Dynamometer)

MINIMAT-EC-Servo Screwdriver handheld

Asynchronous motors. 5/48 Permissible combinations of mechanical designs for 1PL6 motors,

Gardner Denver / Tamrotor Enduro 25 Rotary Screw Compressor, with Adaptable Compressor Speed, designed to produce more gas flow per bhp.

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

CFL: Air volume: Up to 8,200m³/h Vacuum: Up to 5,000Pa Filter area: m²

Unique Compressed Air Management System. GD Connect 12. The perfect fit

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

DATA SHEET. L1210/65/68 Tray loaders incorporating VAM1202/12 mechanism for 2x Speed. Philips Optical Storage. Philips Components

Installation, Operation and Maintenance Manual

2 Telecommunications Data Center Facility Requirements

Supplementary operating instructions for your air curtain system Controller TMC 500

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Removal and Installation8

Laserline LDM The compact class for diode laser

Provisional Product Information. ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Intelligent vibration monitoring.

Matsushita. VF-C Compact. Inverter NEW: - Ultra-compact - Latest technology - Cost effective. Configurator software Motion Control Ver.1.

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

07. har-link INTERFACE CONNECTORS

List of forms CLAP/WGP by subject /68/UE

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

IDS 500 mobile Intelligent mobile chart recorder

8 Submersible Motors Standard

PFC Mini TM Power Factor Corrected AC-DC Switchers

Thin clients JC500X - 1 Reference guide

DATA SHEET Compact Genset Controller, CGC 200

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Tel: AC Power for Business-Critical Continuity TM

Manual Simatek Control Unit GFC 32

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Model KT 53 Cooling incubators with thermoelectric cooling

kyalfa V- VDD/VDD6 General Contents

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Rotary Measuring Technology

PRODUCT FEATURES AND ADVANTAGES

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

Transcription:

AIR Compressor V-belt Connection Level energy efficiency motor Efficient motor specialized for compressors with long service life Rational configuration of compressors within the same range satisfies the needs of air displacement. Advanced gas-oil separation system with less oil, which is easy to maintain. 4KW-KW, belt transmission KW-0KW, direct coupling transmission PCG Series Coupling / Gear variable transmission High-end configuration of intake control system World-renowned compressor Gas-oil separator is in conformity with /DIR standard. Efficient Cooling System Radiator: sufficient cooling area, high-end manufacturing quality Cooling fan: in conformity with EU Eff standard, high efficiency, low noise and longer service life Intelligent operation: owing to adjustment of oil temperature by the, lubrication oil always keeps in the optimal working condition 0/0

AIR Compressor The compressor is equipped with monitoring system, of which the LCD monitor helps you monitor the operation of compressor in real time and has multiple functions such as data display and monitoring. Protection function when starting up Automatic alarm for overload, over and high temperature, shutdown protection Mechanical over protection Centrifugal Fan Driving Wheel Belt Pulley Shield Electric Motor Spring Air Filter Gas-oil Separator Core Safety Valve Clean outlet Drainage valve Electrical Safety World-renowned brand of components Passing UL Certification Self-test every time before start of the compressor Multi-layer self-protection functions Data recovery function after failure 03/04

Air Intake Valve Compressor Radiator Gas-oil Separator AIR Compressor Holes for Forklift Emergency Stop Button Control Panel Electrical Cabinet Power Input Drainage The chassis with anti-twist and liquid-impermeable design could bring 00% safety protection for the ground. Completely closed cavity in the chassis ensures drainage at one time in case of occurrence of internal leakage. Flexible pipes have good heat radiation performance with no leakage,low vibration and low noise. Large air-conditioned delivery system can make outlet air temperature only -0 C higher than that in the inlet,environmental-friendly. Multiple-layer anti-vibration design can reduce the noise pollution arising from vibration and friction. Double vibration absorbing bracket and chassis ensure lowest vibration in operation. The flexible chassis with self-supporting bracket ensures no structural friction noise in transportation. The integrated design of air duct and sound absorbing material can reduce the noise effectively. Energy Conservation and Environmental Protection Professional and accurate calculation of electromotor and compressor configuration data ensures highest operational efficiency with less consumption. The smooth surface is fire-resistant, dustproof, oil-proof and environmental-friendly. The unique internal dustproof design and the dustproof bars with specially-fabricated casing ensure perfect dustproof effect. 0/06

AIR Compressor Switch box conforming to DIN and VDE standards Luminous LCD for continuous simple text and important operating parameters display. Display of all operation data for help in form of figures. Display of operating condition of variable frequency compressor in percentage. Control Panel Easy Maintenance User-friendly design, reserve space for easy and convenient repair and maintenance. Automatically reminding maintenance time and fault inquiry of control system. Information maintenance through AIR CONTROL. Economic control panel can be seen from angle. Display of all important running statuses. The best operation mode is optional. Visibility of operating parameters-including hardware and software needed(optional). Automatic shutdown of compressor before activation of safety valve in fault condition. 0/0

AIR Compressor channels for change-over of compressor switch channels for display of compressor reduction time control channels for failure warning of 4 auxiliary outputs equipment Management of auxiliary input devices Air station including auxiliary equipment can be managed through Air Control 3. Each compressor can conduct cycle operation within the scope. All compressors operations are consistent with that of each other. The joint control of compressor could greatly improve efficiency with low cost. System load Activation of remote operation Final Text display of operation warning / fault Compressor temperature fault Motor fault Service interval fault.when service expires,the service hotline will appear. Date/real-time clock Compression temperature Sensor error Total running hours Full load hours No-load hours Standby hours Display of operating condition of variable frequency compressor in percentage Progress curve of and time Progress curve of final temperature and time 09/0

Technical Data of PCK Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCK/A. 0.00. 44.3 6 30 PCK/0A. 6.6.0 3. 0 30 PCK/A.33. 9.6 6 3 PCK/0A.00.. 0 3 PCK0/A 3.33.3. 6 6 G" PCK0/0A.9 6. 0 6 G" PCK/A..6 3. 0. 6 6 G" 40 PCK/0A PCK30/A PCK30/0A PCK40/A. 30 43.33.33.6 6.6.6 3. 3. 4.6 9 6.4.4 64.3 0 0 6 6 6 0 0 0 G" G" G" G /4" 40 0 3 0 PCK- PCK0-30 000 00 inch 39 4 00 0 inch 3 00 00 inch 40 4 PCK40/0A 30 6.33 4. 4. 0 0 G /4" 9 PCK40-0 00 9 040 4 300 PCK0/A PCK0/0A PCK60/A PCK60/0A PCK/A 3 3 9.33.6.00 0.33 6.6.9 4.9. 6. 9.4..0 6.9 3. 334.6 0 0 6 6 6 4 4 4 4 G /4" G /4" 0 40 00 300 PCK60- PCK00 PCD-00 PCD0-0 0 00 4 4 0 430 430 40 60 6 6 6 9 9 60 0 63 63 64 69 PCK/0A 44.33.6 30. 0 0 PCD0-40 40 6 9 000 9 PCK00/A PCK00/A 93.33 0.00.6 0. 4.9 33.9 0 6 0 0 60 00 PCG00-0 PCG0-0 0 00 0 40 60 6 60 0 64 69 Technical Data of PCD Series () PCG0-40 40 6 9 000 9 kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCD/A.00 9.3 330.6 6 4 00 PCD00/A 0.00.3 440.4 6 0 0 PCD0/A 60.00.6 6.6 6 0 6 PCD0/0A 93.33.6.4 0 0 6 PCD0/A 0 30.00.6.0 6 G /" PCD0/0A 0.33. 0 G /" 0 PCD0/A 3 33.33 3.0.4 6 G /" 30 PCD0/0A 3 36.6.4 64.3 0 G /" 300 PCD340/A 0 6.6 43.0 3. 6 DN0 00 Technical Data of PCG Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCG00/0A.00. 39.0 0 0 60 PCG0/A 60 43.33 9.0 03. 6 6 G /" 300 PCG0/0A 60 4.00 6. 9 0 6 G /" PCG0/A PCG0/0A PCG340/0A 00 00 0 6.6 00.00.6 34.6 30.0 40.6 3. 0.4 0.0 0 0 6 6 6 DN0 DN0 DN0 4430 40 300. Voltages of 30V/V/400V and 60HZ are available. /

Technical Data of PCK Series () PCK/A-A PCK/0A-A PCK/A-A PCK/0A-A PCK0/A-A kw.. Capacity (FAD) l/s m³min cfm 0.00 6.6.33.00 3.33..0...3 44.3 3. 9.6.. Maximum working bar psig 6 0 6 0 6 Noise level db(a) 6 HZ/Phase/ Voltage Dimension G" Weight 30 30 3 3 PCK- PCK0-30 PCK40-0 000 00 00 inch 39 4 9 00 0 040 inch 3 4 00 00 300 inch 40 4 PCK0/0A-A.9 6. 0 6 G" PCK60-4 430 6 9 63 PCK/A-A PCK/0A-A PCK30/A-A PCK30/0A-A PCK40/A-A.. 30.6 43.33.33.6 6.6 3..6 3. 3. 4.6 0. 9 6.4.4 64.3 0 0 6 6 6 6 6 0 0 0 G" G" G" G" G /4" 40 40 0 3 0 PCK00 PCD-00 PCD0-0 PCD0-40 0 00 40 4 0 6 430 40 60 9 6 6 9 60 0 000 63 64 69 9 PCK40/0A-A 30 6.33 4. 4. 0 0 G /4" 9 PCG00-0 0 40 6 60 64 PCK0/A-A 3 9.33.9. 6 4 G /4" 0 PCG0-0 00 0 60 0 69 PCK0/0A-A PCK60/A-A 3.6.00 4.9..0 6.9 0 6 4 4 G /4" 40 PCG0-40 40 6 9 000 9 PCK60/0A-A 0.33 6. 3. 0 4 00 PCK/A-A 6.6 9.4 334.6 6 300 PCK/0A-A 44.33.6 30. 0 0 PCK00/A-A 93.33.6 4.9 6 0 60 PCK00/A-A 0.00 0. 33.9 0 0 00 Technical Data of PCD Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCD/A-A.00 9.3 330.6 6 4 00 PCD00/A-A 0.00.3 440.4 6 0 0 PCD0/A-A 60.00.6 6.6 6 0 6 PCD0/0A-A 93.33.6.4 0 0 6 PCD0/A-A 0 30.00.6.0 6 G /" PCD0/0A-A 0.33. 0 G /" 0 PCD0/A-A 3 33.33 3.0.4 6 G /" 30 PCD0/0A-A 3 36.6.4 64.3 0 G /" 300 PCD340/A-A 0 6.6 43.0 3. 6 DN0 00 Technical Data of PCG Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCG00/0A-A.00. 39.0 0 0 60 PCG0/A-A 60 43.33 9.0 03. 6 6 G /" 300 PCG0/0A-A 60 4.00 6. 9 0 6 G /" PCG0/A-A PCG0/0A-A PCG340/0A-A 00 00 0 6.6 00.00.6 34.6 30.0 40.6 3. 0.4 0.0 0 0 6 6 6 DN0 DN0 DN0 4430 40 300. Voltages of 30V/V/400V and 60HZ are available. 3/4

POWERLINK L Series Air Compressors VSD (variable speed driving) air compressors: alter the motor s rotate speed by changing frequency, the airflow can therefore be regulated. POWERLINK L Series Air Compressors With years permanent magnet technology, the motor and compressor air end utilize built-in gearless direct structure, which makes the machine more compact and ensures 00% transmission efficiency; Acquire 6 patents; Energy-efficient Features Working conditions: permanent magnet motor ensures very high efficiency even if the speed is low and air consumption is small. Save energy consumption when unloading the system (variable frequency and energy-saving). Save the wasted energy consumption when controlling bandwidth (variable frequency and energy-saving). Save energy consumption when starting the machine (variable frequency and energy-saving). Technical Advantages Motor Efficiency (%) Efficiency Comparation 99 9 9 93 9 9 3 9 0 00 000 00 000 00 3000 300 4000 Motor Speed (rpm) Small in size: the size of the motor is about one third of that of normal frequency modulation motors, and the small size makes the machine easy to assembly and disassembly. Stable performance: permanent magnet High-Efficiency PM Motor New Screw Rotor High-end software design Simple structure greatly facilitates repair and maintenance Perfect combination between frequency converting control and permanent magnetic screw driving synchronous motors adopt superior Nd-Fe-B magnets which would not lose magnetic force even under 0 and have more than years service life; Stator coil utilizes corona resistant enameled wires that are specialized for inverters use only; the wires are characterized by excellent insulation performance and long service life. Distinction between POWERLINK TRL Series VSD Screw Compressors and Power Frequency Screw Compressors More stable air Shock-free when start-up Variable airflow control Cover Shaft Stator core Rotor core Magnet Coil Better voltage adaptability for AC supply Lower noise level /6

Technical Data of L Series () Technical Data of L Series () Rated bar psig Rated airflow rate m³min cfm kw Airend model (integrated permanent magnet motor and compressor) Max. RPM Oil seperator standard HZ/Phase /Voltage Rated bar psig Rated airflow rate m³min cfm kw Airend model (integrated permanent magnet motor and compressor) Max. RPM Oil seperator standard HZ/Phase /Voltage PCF/A 0..6. TRLPM-. PCF/A-A 0..6. TRLPM-. PCF/A 6 3. 4.3. TRLPM-. PCF/A-A 6 3. 4.3. TRLPM-. PCF30/0A 0 3..0 TRLPM- PCF30/0A-A 0 3..0 TRLPM- PCF30/3A 3. 3.4.4 TRLPM- PCF30/3A-A 3. 3.4.4 TRLPM- PCF0/A 0. 6. 4.9 3 TRL0PM-3 PCF0/A-A 0. 6. 4.9 3 TRL0PM-3 PCF0/A PCF60/0A PCF60/3A PCFD/A 0 3 6. 0. 6. 6. 6.4 3. 4.9.6.6 3. TRL0PM-3 TRL0PM- TRL0PM- TRLPM-. Gearless direct PCF0/A-A PCF60/0A-A PCF60/3A-A PCFD/A-A 0 3 6. 0. 6. 6. 6.4 3. 4.9.6.6 3. TRL0PM-3 TRL0PM- TRL0PM- TRLPM-. Gearless direct PCFD/A 6 3. 4.3. TRLPM-. PCFD/A-A 6 3. 4.3. TRLPM-. PCFD30/0A 0 3..0 TRLPM- PCFD30/0A-A 0 3..0 TRLPM- PCFD30/3A 3. 3.4.4 TRLPM- PCFD30/3A-A 3. 3.4.4 TRLPM- PCFD0/A 0. 6. 4.9 3 TRL0PM-3 PCFD0/A-A 0. 6. 4.9 3 TRL0PM-3 PCFD0/A 6 6. 3. 3 TRL0PM-3 PCFD0/A-A 6 6. 3. 3 TRL0PM-3 PCFD60/0A 0 6. 4.9 TRL0PM- PCFD60/0A-A 0 6. 4.9 TRL0PM- PCFD60/3A 3. 6.4.6 TRL0PM- PCFD60/3A-A 3. 6.4.6 TRL0PM-. The air displacement is caculated based on compressor suction condition (30 ).. The temperature of air outlet dew point is 30 and 0.69MPa. 3. The discharge is caculated in front of the one-way valve. 4. Motor service factor is SF=... The above permanent magnet motors meet energy efficiency level, vessel standard. 6. Meet JB/6430-00, design and installation meet ISO 3 (also 09) standards, airflow rate test is in conformity with /T4, test meets safety requirements of ISO (also /33): JB 4-99 (also B 9.-9).. Voltages of 30V/V/400V and 60HZ are available.. The air displacement is caculated based on compressor suction condition (30 ).. The temperature of air outlet dew point is 30 and 0.69MPa. 3. The discharge is caculated in front of the one-way valve. 4. Motor service factor is SF=... The above permanent magnet motors meet energy efficiency level, vessel standard. 6. Meet JB/6430-00, design and installation meet ISO 3 (also 09) standards, airflow rate test is in conformity with /T4, test meets safety requirements of ISO (also /33): JB 4-99 (also B 9.-9).. Voltages of 30V/V/400V and 60HZ are available. /

Aftertreatment Equipment Air Dryer Technical Data Air dryer AD0L Air process volume m³min 0.6 Work bar 0bar Voltage Phase/0V/0HZ dimension G½ Net weight Net weight Size 0 430 0 Excellent design ensures high efficiency, low consumption, long lifetime; Real time operation parameters display; AD0M ADL ADM ADL 0.6... 0 3bar 0bar 0 3bar 0bar Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ G½ G G G 0 0 40 0 0 40 0 430 0 0 0 0 0 0 0 00 00 Easy operation and cost-effective. ADM AD3L. 0 3bar 0bar Phase/0V/0HZ Phase/0V/0HZ G G 40 60 40 60 00 00 00 0 Precision filters AD3M AD0L 0 3bar 0bar Phase/0V/0HZ Phase/0V/0HZ G G½ 60 0 60 0 00 0 0 40 000 Four class filter Q, P, S, C, meet various filtration needs; High filtration precision, easy maintenance and change; AD0M AD0L AD0M ADL ADM 6. 6... 0 3bar 0bar 0 3bar 0bar 0 3bar Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ G½ G½ G½ 0 0 0 0 0 0 0 0 0 0 0 40 000 30 0 03 30 0 03 0 60 3 0 60 3 Long service life. AD0L AD0M 0.9 0.9 0bar 0 3bar 3Phase/300V/0HZ 3Phase/300V/0HZ 0 0 0 0 330 60 3 330 60 3 Air receiver Standard vessel for safe use; AD30L AD30M AD60L.. 6 0bar 0 3bar 0bar 3Phase/300V/0HZ 3Phase/300V/0HZ 3Phase/300V/0HZ 330 330 30 330 330 30 330 60 3 330 60 3 30 0 49 Multiple models of volume and ; Quality product with cost-effective. AD60M AD0L AD0M 6 0 3bar 0bar 0 3bar 3Phase/300V/0HZ 3Phase/300V/0HZ 3Phase/300V/0HZ 30 40 40 30 40 40 30 0 49 00 0 463 00 0 463 AD0L 6. 0bar 3Phase/300V/0HZ DN0 60 60 0 0 433 AD30L 3 0bar 3Phase/300V/0HZ DN0 0 0 00 300 6 AD430L 43. 0bar 3Phase/300V/0HZ DN00 0 0 30 60. Also adapt to other voltage or frequency. 9/0

Precision Filters Specification (Class Q) Precision filters specification (Class P) Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element AF0LQ 0.6 0bar G. 9 0 3 AF0LP 0.6 0bar μm ppm G. 9 0 3 AF0MQ 0.6 0 3bar G. 9 0 3 AF0MP 0.6 0 3bar μm ppm G. 9 0 3 AFLQ. 0bar G. 9 0 3 AFLP. 0bar μm ppm G. 9 0 3 AFMQ. 0 3bar G. 9 0 3 AFMP. 0 3bar μm ppm G. 9 0 3 AFLQ. 0bar G 3. 9 0 3 AFLP. 0bar μm ppm G 3. 9 0 3 AFMQ. 0 3bar G 3. 9 0 3 AFMP. 0 3bar μm ppm G 3. 9 0 3 AF3LQ 0bar G 4. 9 0 3 AF3LP 0bar μm ppm G 4. 9 0 3 AF3MQ 0 3bar G 4. 9 0 3 AF3MP 0 3bar μm ppm G 4. 9 0 3 AF0LQ 0bar G½ 3 63 AF0LP 0bar μm ppm G½ 3 63 AF0MQ 0 3bar G½ 3 63 AF0MP 0 3bar μm ppm G½ 3 63 AF0LQ 6. 0bar G½ 3 63 AF0LP 6. 0bar μm ppm G½ 3 63 AF0MQ 6. 0 3bar G½ 3 63 AF0MP 6. 0 3bar μm ppm G½ 3 63 AFLQ. 0bar 3 63 AFLP. 0bar μm ppm 3 63 AFMQ. 0 3bar 3 63 AFMP. 0 3bar μm ppm 3 63 AF0LQ 0.9 0bar 3 63 AF0LP 0.9 0bar μm ppm 3 63 AF0MQ 0.9 0 3bar 3 63 AF0MP 0.9 0 3bar μm ppm 3 63 AF30LQ. 0bar 3 63 AF30LP. 0bar μm ppm 3 63 AF30MQ. 0 3bar 3 63 AF30MP. 0 3bar μm ppm 3 63 AF60LQ 6 0bar φ9 399 AF60LP 6 0bar μm ppm φ9 399 AF60MQ 6 0 3bar φ9 399 AF60MP 6 0 3bar μm ppm φ9 399 AF0LQ 0bar φ9 399 00 AF0LP 0bar μm ppm φ9 399 00 AF0MQ 0 3bar φ9 399 00 AF0MP 0 3bar μm ppm φ9 399 00 AF0LQ 6. 0bar DN0 6 φ9 399 0 AF0LP 6. 0bar μm ppm DN0 6 φ9 399 0 AF30LQ 3 0bar DN0 φ9 9 9 AF30LP 3 0bar μm ppm DN0 φ9 9 9 AF430LQ 43. 0bar DN0 φ9 9 30 AF430LP 43. 0bar μm ppm DN0 φ9 9 30. Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice.. Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice. /

Precision filters specification (Class S) Precision filters specification (Class C) Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element AF0LS 0.6 0bar 0.0μm 0.0ppm G. 9 0 3 AF0LC 0.6 0bar 0.0μm G. 9 0 3 AF0MS 0.6 0 3bar 0.0μm 0.0ppm G. 9 0 3 AF0MC 0.6 0 3bar 0.0μm G. 9 0 3 AFLS. 0bar 0.0μm 0.0ppm G. 9 0 3 AFLC. 0bar 0.0μm G. 9 0 3 AFMS. 0 3bar 0.0μm 0.0ppm G. 9 0 3 AFMC. 0 3bar 0.0μm G. 9 0 3 AFLS. 0bar 0.0μm 0.0ppm G 3. 9 0 3 AFLC. 0bar 0.0μm G 3. 9 0 3 AFMS. 0 3bar 0.0μm 0.0ppm G 3. 9 0 3 AFMC. 0 3bar 0.0μm G 3. 9 0 3 AF3LS 0bar 0.0μm 0.0ppm G 4. 9 0 3 AF3LC 0bar 0.0μm G 4. 9 0 3 AF3MS 0 3bar 0.0μm 0.0ppm G 4. 9 0 3 AF3MC 0 3bar 0.0μm G 4. 9 0 3 AF0LS 0bar 0.0μm 0.0ppm G½ 3 63 AF0LC 0bar 0.0μm G½ 3 63 AF0MS 0 3bar 0.0μm 0.0ppm G½ 3 63 AF0MC 0 3bar 0.0μm G½ 3 63 AF0LS 6. 0bar 0.0μm 0.0ppm G½ 3 63 AF0LC 6. 0bar 0.0μm G½ 3 63 AF0MS 6. 0 3bar 0.0μm 0.0ppm G½ 3 63 AF0MC 6. 0 3bar 0.0μm G½ 3 63 AFLS. 0bar 0.0μm 0.0ppm 3 63 AFLC. 0bar 0.0μm 3 63 AFMS. 0 3bar 0.0μm 0.0ppm 3 63 AFMC. 0 3bar 0.0μm 3 63 AF0LS 0.9 0bar 0.0μm 0.0ppm 3 63 AF0LC 0.9 0bar 0.0μm 3 63 AF0MS 0.9 0 3bar 0.0μm 0.0ppm 3 63 AF0MC 0.9 0 3bar 0.0μm 3 63 AF30LS. 0bar 0.0μm 0.0ppm 3 63 AF30LC. 0bar 0.0μm 3 63 AF30MS. 0 3bar 0.0μm 0.0ppm 3 63 AF30MC. 0 3bar 0.0μm 3 63 AF60LS 6 0bar 0.0μm 0.0ppm φ9 399 AF60LC 6 0bar 0.0μm φ9 399 AF60MS 6 0 3bar 0.0μm 0.0ppm φ9 399 AF60MC 6 0 3bar 0.0μm φ9 399 AF0LS 0bar 0.0μm 0.0ppm φ9 399 00 AF0LC 0bar 0.0μm φ9 399 00 AF0MS 0 3bar 0.0μm 0.0ppm φ9 399 00 AF0MC 0 3bar 0.0μm φ9 399 00 AF0LS 6. 0bar 0.0μm 0.0ppm DN0 6 φ9 399 0 AF0LC 6. 0bar 0.0μm DN0 6 φ9 399 0 AF30LS 3 0bar 0.0μm 0.0ppm DN0 φ9 9 9 AF30LC 3 0bar 0.0μm DN0 φ9 9 9 AF430LS 43. 0bar 0.0μm 0.0ppm DN0 φ9 9 30 AF430LC 43. 0bar 0.0μm DN0 φ9 9 30. Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice.. Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice. 3/4

Air Receiver Technical Data Specification Work Total height Inner diameter φ bar dimension Net weight AT06L() 0.6m³/.0Mpa 0bar 300 00 0 AT06M() 0.6m³/.3Mpa 0 3bar 300 00 0 AT0L().0m³/.0Mpa 0bar 00 00 6 AT0M().0m³/.3Mpa 0 3bar 00 00 6 AT0L().0m³/.0Mpa 0bar 00 00 DN0 6 AT0M().0m³/.3Mpa 0 3bar 00 00 DN0 6 AT30L() 3.0m³/.0Mpa 0bar 00 300 DN0 9 AT30M() 3.0m³/.3Mpa 0 3bar 00 300 DN0 9 AT40L() 4.0m³/.0Mpa 0bar 00 400 DN00 AT40M() 4.0m³/.3Mpa 0 3bar 00 400 DN00 AT0L().0m³/.0Mpa 0bar 300 00 DN00 6 AT0M().0m³/.3Mpa 0 3bar 300 00 DN00 6 AT06L() C 0.6/.0 0bar 300 00 0 AT06M() C 0.6/.3 0 3bar 300 00 0 AT0L() C.0/.0 0bar 00 00 6 AT0M() C.0/.3 0 3bar 00 00 6 AT0L() C.0/.0 0bar 00 00 DN0 6 AT0M() C.0/.3 0 3bar 00 00 DN0 6 AT30L() C 3.0/.0 0bar 00 300 DN0 9 AT30M() C 3.0/.3 0 3bar 00 300 DN0 9 AT40L() C 4.0/.0 0bar 00 400 DN00 AT40M() C 4.0/.3 0 3bar 00 400 DN00 AT0L() C.0/.0 0bar 300 00 DN00 6 AT0M() C.0/.3 0 3bar 300 00 DN00 6. The specification and detail are subject to change without prior notice. /6