Data & signal protection ESP D & TN Series

Similar documents
NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN

Hazardous Area Protection

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

Lightning Current Equipotential Bonding SPDs

BLITZDUCTOR XTU Universal lightning current / surge arrester

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

Surge Protective Device

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Surge Protection for Surveillance Systems

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

SPM Series Plug-in Surge Protection

Overvoltage Protection Devices

SPM Series. Plug-in Surge Protection

PT 3-PB-ST. Extract from the online catalog. Order No.:

MDP and FDB lightning barriers Safety for data and control systems in plants and industrial and potentially explosive

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

MACX MCR-EX-SD LP(-SP)

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

PHOENIX CONTACT - 02/2008

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester

Overvoltage Protection Devices

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Overvoltage Protection Devices

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

BS th Edition wiring regulations Furse overview

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

Installation / Control Technique

HEMP & IEMI PROTECTION FILTERS FOR MAINS POWER LINES

Terminal Boxes Series 8118

Operating Instructions

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PHOENIX CONTACT - 05/2007

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PHOENIX CONTACT - 12/2007

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

EMOSAFE EN-100 Network Isolators for PCB assembly

PI-EX-ME-2NAM/COC-120VAC

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Overvoltage Protection Devices

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PI-EX-ME-2NAM/COC-24VDC

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

DSP 600 SERIES Distribution Surge Protector

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Surge Protection Products for the small office/home office and professional grade

Technical Data. General specifications. Rated operating distance s n 3 mm

5 Fieldbus Technology

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

PHOENIX CONTACT - 01/2008

Technical Specification

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

CLIPLINE complete. The modular terminal block system for all applications

Overvoltage Protection Devices

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

ESP D1 Series. Enhanced Mains Power Protectors

KINAX WT720 absolute, programmable angular postion transmitter

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

KeyTek ECAT. Expert Computer-Aided Testing for pulsed EMI immunity. Technical Specifications

System Components Surge Arrester HAW 261 and HAW 262

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

SITOP in the SIMATIC Design

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Technical data: Pin Spacing

LPI SG + SST Spark Gap Surge Filter

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

SUBCON-PLUS-PROFIB...

Surge & Filter Protection Addressing your industrial power quality needs.

ISOMETER isoev425 with coupling device AGH420

Devices raised mounting

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Crompton Instruments Ebony Current Transformers

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

R507 I.S. Interface Module User Manual

QUINT-PS AC/24DC/10

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

High Performance Network Isolator

Surge Protection Devices (SPD)

Transcription:

ESP D & TN Series Combined Category D, C, B tested protector (to BS EN 66) suitable for most twisted pair signalling applications. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. ESP TN suitable for Broadband, POTS, dial-up, T/E, lease line and *DSL telephone applications. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Low in-line resistance minimises unnecessary reductions in signal strength Strong, flame retardant, ABS housing Supplied ready for flat mounting on base or side Built-in DIN rail foot for simple clip-on mounting to top hat DIN rails Colour coded terminals give a quick and easy installation check - grey for the dirty (line) end and green for the clean end Screen terminal enables easy connection of cable screen to earth Substantial earth stud to enable effective earthing Integral earthing plate for enhanced connection to earth via a CME kit ESP 06D and ESP 50D have PADS reference 086/00055 (ESP 06D) and 086/00055 (ESP 50D) ESP TN is suitable for telecommunication applications in accordance with Telcordia and ANSI Standards (see Application Note AN005) Application Use on twisted pair lines, e.g. those found in process control equipment, modems and computer communications interfaces. Installation Connect in series with the data communication or signal line either near where it enters or leaves the building or close to the equipment being protected (e.g. within its control panel). Either way, it must be very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories Combined Mounting/ing kits: CME Mount & earth up to protectors CME 8 Mount & earth up to 8 protectors CME 6 Mount & earth up to 6 protectors CME Mount & earth up to protectors Weatherproof enclosures: WBX /G For use with up to protectors WBX, WBX /G For use with up to protectors WBX, WBX /GS For use with a CME and up to protectors WBX 8, WBX 8/GS For use with a CME 8 and up to 8 protectors WBX 6//G For use with one or two CME 6and up to protectors Install in series (in-line) DIRTY From line To equipment NOTE: Derivatives of these protectors are available ready-boxed to IP66, for use in damp or dirty environments. Slim Line (ESP SL), ATEX (ESP SLX) and PCB mount (ESP PCB) versions are also available. If your system requires a protector with a very low resistance or higher current, see the ESP E & H Series. Also use the ESP E Series for systems needing a higher bandwidth. Protectors for -wire (ESP SL/W) and RTD (ESP RTD, ESP SL RTD) are available, as are the space saving protectors (ESP Q, ESP SL Series). The ESP KT and TN Series are additional protectors specifically for telephone lines. The ESP KS Series are protectors for data and signal lines on an LSA-PLUS module. / Total Solution to ing & Lightning Protection LITGB 05

ESP D & TN Series ESP D & TN Series - Technical specification Electrical Specification ESP 06D ESP 5D ESP 0D ESP 50D ESP 0D ESP TN Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 9 V 7. V 58 V V 96 V Current rating (signal) 00 ma In-line resistance (per line ±0%) 9. Ω 9. Ω 9. Ω 9. Ω 9. Ω. Ω Bandwidth (- db 50 Ω system) 800 khz.5 MHz MHz 6 MHz 9 MHz 0 MHz Transient Specification ESP 06D ESP 5D ESP 0D ESP 50D ESP 0D ESP TN Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-.0 V 5.0 V.0 V 78.0 V 55 V 95 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-.5 V.5 V.5 V 76.0 V 50 V 90 V B test kv 0/700 μs to BS EN/EN/IEC 66-0.0 V.0 V.5 V 7.0 V 5 V 98 V 5 kv, 0/700 μs () 0.5 V.8 V. V 7.9 V 50 V 00 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP 06D ESP 5D ESP 0D ESP 50D ESP 0D ESP TN Temperature range -0 to +80 C Connection type Screw terminal Conductor size (stranded).5 mm connection M6 stud Case material ABS UL9 V-0 Weight: Unit 0.08 kg Packaged (per 0) 0.85 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 5 μa (ESP 5D, ESP 0D, ESP 50D, ESP 0D) and <00 μa (ESP 06D) () Maximum working voltage (DC or AC peak) measured at < ma leakage (ESP 5D, ESP 0D, ESP 50D, ESP 0D), < 0 ma (ESP 06D) and < 0 μa (ESP TN) () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5,Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 8 mm 05 mm M clearance 0 mm 5 mm 9 mm 09 mm M clearance Total Solution to ing & Lightning Protection LITGB 05 /5

ESP E Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair signalling applications which require either a lower in-line resistance, an increased current or a higher bandwidth than the ESP D Series. Also suitable for DC power applications less than.5 Amps. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Very low ( Ω) in-line resistance allows resistance critical applications (e.g. alarm loops) to be protected High (.5 A) maximum running current High bandwidth enables higher frequency (high traffic or bit rate) data communications Screen terminal enables easy connection of cable screen to earth Strong, flame retardant, ABS housing Built-in DIN rail foot for simple clip-on mounting to top hat DIN rails Colour coded terminals give a quick and easy installation check - grey for the dirty (line) end and green for clean Substantial earth stud to enable effective earthing Supplied ready for flat mounting on base or side Integral earthing plate for enhanced connection to earth via CME kit ESP 06E and ESP 5E have Network Rail Approval PA05/007. NRS PADS reference 086/0000 (ESP 06E) and 086/00000 (ESP 5E) Application Use these units to protect resistance sensitive, higher frequency or running current systems, e.g. high speed digital communications equipment or systems with long signal lines. Installation Connect in series with the data communication or signal line either near where it enters or leaves the building or close to the equipment being protected (e.g. within its control panel). Either way, it must be very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories Combined Mounting/ing kits: CME Mount & earth up to protectors CME 8 Mount & earth up to 8 protectors CME 6 Mount & earth up to 6 protectors CME Mount & earth up to protectors Weatherproof enclosures: WBX /G For use with up to protectors WBX, WBX /G For use with up to protectors WBX, WBX /GS For use with a CME and up to protectors WBX 8, WBX 8/GS For use with a CME 8 and up to 8 protectors WBX 6//G For use with one or two CME 6and up to protectors Install in series (in-line) DIRTY From line To equipment NOTE: Slim Line (ESP SL), ATEX (ESP SLX) and PCB mount (ESP PCB) are available. For many twisted pair data and signal applications, the lower cost ESP D Series may be suitable. For applications requiring higher current (.5 A to A) or ultra-low in-line resistance, the ESP H Series protectors may be more suitable. For data and signal lines on LSA-PLUS modules, use the ESP KS Series. /6 Total Solution to ing & Lightning Protection LITGB 05

ESP E Series ESP E Series - Technical specification Electrical Specification ESP 06E ESP 5E ESP 0E ESP 50E ESP 0E Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 6.7 V 6.7 V 56.7 V V Current rating (signal).5 A In-line resistance (per line ±0%).0 Ω Bandwidth (- db 50 Ω system) 5 MHz Transient Specification ESP 06E ESP 5E ESP 0E ESP 50E ESP 0E Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-6.0 V 9.0 V 60.0 V 86.0 V 80 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-6. V 8.0 V 9.0 V 7.5 V 70 V B test kv 0/700 μs to BS EN/EN/IEC 66-6.0 V 5.5 V.5 V 65.0 V 60 V 5 kv, 0/700 μs () 7.0 V 6. V. V 65.8 V 65 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP 06E ESP 5E ESP 0E ESP 50E ESP 0E Temperature range -0 to +80 C Connection type Screw terminal Conductor size (stranded).5 mm connection M6 stud Case material ABS UL9 V-0 Weight: Unit 0.08 kg Packaged (per 0) 0.85 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa (ESP 5E, ESP 0E, ESP 50E, ESP 0E) and < 00 μa (ESP 06E) () Maximum working voltage (DC or AC peak) measured at < 5 ma leakage (ESP 5E, ESP 0E, ESP 50E, ESP 0E) and < 0 ma (ESP 06E) () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5,Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 8 mm 05 mm M clearance 0 mm 5 mm 9 mm 09 mm M clearance Total Solution to ing & Lightning Protection LITGB 05 /7

ESP H Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair signalling applications which require either a lower in-line resistance or an increased current than the ESP D or E Series. Also suitable for DC power applications less than Amps. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Ultra-low (< 0.05 Ω) in-line resistance allows resistance critical applications (e.g. alarm loops) to be protected Very high ( A) maximum running current Strong, flame retardant ABS housing Supplied ready for flat mounting on base or side Built-in DIN rail foot for simple clip-on mounting to top hat DIN rails Colour coded terminals give a quick and easy installation check - grey for the dirty (line) end and green for clean Screen terminal enables easy connection of cable screen to earth Substantial earth stud to enable effective earthing Integral earth plate enables enhanced connection to earth via CME kit Application Use these applications to protect resistance sensitive or higher running current systems, e.g. systems with long signal lines, or DC power applications. Installation Connect in series with the data communication or signal line either near where it enters or leaves the building or close to the equipment being protected (e.g. within its control panel). Either way, it must be very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories Combined Mounting/ing kits: CME Mount & earth up to protectors CME 8 Mount & earth up to 8 protectors CME 6 Mount & earth up to 6 protectors CME Mount & earth up to protectors Weatherproof enclosures: WBX /G For use with up to protectors WBX, WBX /G For use with up to protectors WBX, WBX /GS For use with a CME and up to protectors WBX 8, WBX 8/GS For use with a CME 8 and up to 8 protectors WBX 6//G For use with one or two CME 6 and up to protectors Install in series (in-line) DIRTY From line To equipment NOTE: For some data and signal applications with lower current, higher in-line resistance or higher bandwidth requirements, the ESP D or E Series protectors or the Slim Line ESP SL Series may be more suitable. If the protector is to be mounted directly onto a PCB, use the ESP PCB/**D or ESP PCB/**E protectors. /8 Total Solution to ing & Lightning Protection LITGB 05

ESP H Series ESP H Series - Technical specification Electrical Specification ESP 06H ESP 5H ESP 0H ESP 50H ESP 0H Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 6.7 V 6.7 V 56.7 V V Current rating (signal) A In-line resistance (per line ±0%) 0.05 Ω Bandwidth (- db 50 Ω system) 60 KHz 0 KHz 0 KHz 0 KHz 0 KHz Transient Specification ESP 06H ESP 5H ESP 0H ESP 50H ESP 0H Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-.0 V 7.5 V 6.0 V 67.0 V 50 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-.0 V 6.5 V 5.0 V 66.5 V 5 V B test kv 0/700 μs to BS EN/EN/IEC 66-0.5 V 5.5 V.5 V 65.0 V 0 V 5 kv, 0/700 μs () 0.8 V 6. V. V 65.8 V 5 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP 06E ESP 5E ESP 0E ESP 50E ESP 0E Temperature range -0 to +80 C Connection type Screw terminal Conductor size (stranded).5 mm connection M6 stud Case material ABS UL9 V-0 Weight: Unit 0.08 kg Packaged (per 0) 0.85 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa (ESP 5H, ESP 0H, ESP 50H, ESP 0H) and < 00 μa (ESP 06H) () Maximum working voltage (DC or AC peak) measured at < 5 ma leakage (ESP 5H, ESP 0H, ESP 50H, ESP 0H) and < 0 ma (ESP 06H) () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5,Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 8 mm 05 mm M clearance 0 mm 5 mm 9 mm 09 mm M clearance Total Solution to ing & Lightning Protection LITGB 05 /9

ESP D/BX Series Combined Category D, C, B tested protector (to BS EN 66) based on the ESP D Series and ESP TN but ready-boxed to IP66 for use in damp or dirty environments. Suitable for most twisted pair signalling applications. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. ESP TN suitable for Broadband, POTS, dial-up, T/E, lease line and *DSL telephone applications. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Low in-line resistance minimises unnecessary reductions in signal strength Ready-boxed to IP66 and supplied ready for flat mounting Available with screw terminals or with IDC terminals (by adding /I suffix to part number) Colour coded terminals for quick and easy installation check - grey for the dirty (line) end and green for clean Screen terminal enables easy connection of cable screen to earth Substantial earth stud to enable effective earthing ESP TN/BX and ESP TN/BX are suitable for telecommunication applications in accordance with Telcordia and ANSI Standards (see Application Note AN005) Supplied as standard with screw terminals - for IDC terminals order part code plus /I (e.g. ESP TN/BX/I) ESP TN/BX has Network Rail Approval PA05/0877. NRS PADS reference 087/0786 Application Use these ready-boxed protectors on twisted pair lines in dirty or damp environments. For two wire lines, use /BX versions. For four wire lines, use /BX versions. Installation Connect in series with the data communication, signal or telephone line either near where it enters/leaves the building or close to the equipment being protected. Either way, it must be very close to the system s earth star point. Install in series (in-line) DIRTY LINE A B B A From line LIGHTNING BARRIER ESP 06D/BX EARTH STUD To equipment NOTE: For installation in the equipment panel, protectors which are not boxed may be more suitable. If your system requires a protector with a very low resistance, higher current or higher bandwidth use the ESP E or H Series. Unboxed protectors for -wire RTD systems are available - as are plug-in protectors for telephone lines and compact Slim Line protectors. /0 Total Solution to ing & Lightning Protection LITGB 05

ESP D/BX Series ESP D/BX Series - Technical specification ESP 06D/BX ESP 5D/BX ESP 0D/BX ESP 50D/BX ESP 0D/BX ESP TN/BX Electrical Specification ESP 06D/BX ESP 5D/BX ESP 0D/BX ESP 50D/BX ESP 0D/BX ESP TN/BX Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 9 V 7. V 58 V V 96 V Current rating (signal) 00 ma In-line resistance (per line ±0%) 9. Ω 9. Ω 9. Ω 9. Ω 9. Ω. Ω Bandwidth (- db 50 Ω system) 800 khz.5 MHz MHz 6 MHz 9 MHz 0 MHz ESP 06D/BX ESP 5D/BX ESP 0D/BX ESP 50D/BX ESP 0D/BX ESP TN/BX Transient Specification ESP 06D/BX ESP 5D/BX ESP 0D/BX ESP 50D/BX ESP 0D/BX ESP TN/BX Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-.0 V 5.0 V.0 V 78.0 V 55 V 95 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-.5 V.5 V.5 V 76.0 V 50 V 90 V B test kv 0/700 μs to BS EN/EN/IEC 66-0.0 V.0 V.5 V 7.0 V 5 V 98 V 5 kv, 0/700 μs () 0.5 V.8 V. V 7.9 V 50 V 00 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka ESP 06D/BX ESP 5D/BX ESP 0D/BX ESP 50D/BX ESP 0D/BX ESP TN/BX Mechanical Specification ESP 06D/BX ESP 5D/BX ESP 0D/BX ESP 50D/BX ESP 0D/BX ESP TN/BX Temperature range -0 to +80 C Connection type Screw terminal - for IDC terminal use part number with /I Conductor size (stranded).5 mm connection M6 stud Cable glands Accommodate.-6.7 mm diameter cable (PG7) Degree of protection (IEC 6059) M6 stud Case material PVC Weight: Unit 0. kg Packaged (per 0) 0.5 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa (ESP 5D/BX, ESP 5D/BX, ESP 0D/BX, ESP 0D/BX, ESP 50D/BX, ESP 50D/BX, ESP 0D/BX, ESP 0D/BX) and < 00 μa (ESP 06D/BX & ESP 06D/BX) () Maximum working voltage (DC or AC peak) measured at < ma leakage (ESP 5D/BX, ESP 5D/BX, ESP 0D/BX, ESP 0D/BX, ESP 50D/BX, ESP 50D/BX, ESP 0D/BX, ESP 0D/BX), < 0 ma (ESP 06D/BX, ESP 06D/BX) and < 0 μa (ESP TN/BX, ESP TN/BX) () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5,Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 80 mm 5 mm 0 mm 08 x 50 mm M clearance Depth: 56 mm 5 mm max. Total Solution to ing & Lightning Protection LITGB 05 /

Line Current rating In-line resistance Nottingham, NG EB, UK 0V 6.7V 750mA.0Ω 0kA 6V Data & signal protection ESP SL Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair signalling applications which require either a lower in-line resistance, an increased current and/or higher bandwidth. Also suitable for DC power applications less than 0.75 Amps. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Ultra slim 7 mm width ideal for compact protection of large numbers of lines (e.g. process control installations) Optional LED status indication versions available for low current DC power applications - add L suffix to part number - e.g. ESP SL0L Two stage removable protection module with simple quick release mechanism allowing partial removal for easy line commissioning and maintenance as well as full removal for protection replacement Strong, flame retardant, polycarbonate housing High (750 ma) maximum running current High bandwidth enables higher frequency (high traffic or bit rate) data communications Screen terminal enables easy connection of cable screen to earth Suitable for earthed or isolated screen systems - add /I suffix to part number for versions that require isolated screens - e.g. ESP SL0/I Built-in innovative DIN rail foot with locking feature for simple positioning and clip-on mounting to top hat DIN rails mm terminals allow for larger cross section wiring, stranded wires terminated with ferrules or fitting two wires into a single terminal Convenient earthing through DIN foot and/or earth terminal Very low ( Ω) in-line resistance allows resistance critical applications (e.g. alarm loops) to be protected Application Use these protectors where installation space is at a premium and large numbers of lines require protection (e.g. process control, high speed digital communication equipment or systems with long signal lines). Installation Connect in series with the data communication or signal line either near where it enters or leaves the building or close to the equipment being protected (e.g. within its control panel). Either way, it must be very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories Replacement modules: ESP SLXX/M Standard module replacement where XX is voltage rating (06, 5, 0, 50 or 0) ESP SLXXL/M LED module replacement where XX is voltage rating, as above LINE LINE Lightning Barrier ESP SL/B Base replacement (common for standard and LED modules) ESP SL/I/B Base replacement with isolated screen from earth S From line line Nominal voltage Max working voltage, U c Max surge current Let-through voltage, U p Furse Wilford Road, Clean S To To equipment NOTE: The ESP SL Slim Line Series is also available for protection of -wire, RS 85 and RTD applications (ESP SL/W, ESP SL RS85 & ESP SL RTD). The ESP SL X Series has approvals for use in hazardous areas. / Total Solution to ing & Lightning Protection LITGB 05

ESP SL Series ESP SL Series - Technical specification Electrical Specification ESP SL06 ESP SL5 ESP SL0 ESP SL50 ESP SL0 ESP SL TN Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 6.7 V 6.7 V 56.7 V V 96 V Current rating (signal) 750 ma In-line resistance (per line ±0%).0 Ω Bandwidth (- db 50 Ω system) 5 MHz 5 MHz 5 MHz 5 MHz 5 MHz 0 MHz Transient Specification ESP SL06 ESP SL5 ESP SL0 ESP SL50 ESP SL0 E SP SL TN Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-6.0 V 8. V 6.0 V 90. V 85 V 95 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-6. V 9. V 5. V 77. V 75 V 90 V B test kv 0/700 μs to BS EN/EN/IEC 66-6.0 V 6.8 V 5. V 68. V 65 V 98 V 5 kv, 0/700 μs () 7.0 V 7.5 V 6. V 69. V 70 V 00 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair.5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP SL06 ESP SL5 ESP SL0 ESP SL50 ESP SL0 ESP SL TN Temperature range -0 to +80 C Connection type Screw terminal Conductor size (stranded) mm connection Via DIN rail or mm earth terminal Case material FR polycarbonate UL9 V-0 Weight: Unit 0.08 kg Packaged (per 0) 0.85 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa (ESP SL5, ESP SL0, ESP SL50, ESP SL0 and LED variants) and < 00 μa (ESP SL06 and ESP SL06L) () Maximum working voltage (DC or AC peak) measured at < ma leakage () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5, Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 06.5 mm 0.6 mm 7 mm S S E Total Solution to ing & Lightning Protection LITGB 05 /

Line Nominal voltage Max working voltage, U c Current rating In-line resistance Max surge current Let-through voltage, U p Nottingham, NG EB, UK 0V 6.7V 750mA.0Ω 0kA 6V Data & signal protection ESP SL X Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair signalling applications within hazardous environments (ATEX/IECEx approved). Available for working voltages of up to 5 and 0 Volts. For use at boundaries up to LPZ 0 to protect against flashover through to LPZ to protect sensitive electronic equipment. Features & benefits Approved for use in hazardous environments for the protection of Intrinsically Safe circuits (Classification: II () G, Ex ia (ia Ga) IIC T Gb) Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Ultra slim 7 mm width ideal for compact protection of large numbers of lines (e.g. process control installations) Optional LED status indication versions available for low current DC power applications Negligible self-capacitance and self-inductance offering minimal interference when protecting Intrinsically Safe circuits Very low ( Ω) in-line resistance allows resistance critical applications (e.g. alarm loops) to be protected High (750 ma) maximum running current High bandwidth enables higher frequency (high traffi c or bit rate) data communications Screen terminal enables easy connection of cable screen to earth Suitable for earthed or isolated screen systems - add /I suffi x to part number for versions that require isolated screens Built-in innovative DIN rail foot with locking feature for simple positioning and clip-on mounting to top hat DIN rails mm terminals allow for larger cross section wiring, stranded wires terminated with ferrules or fitting two wires into a single terminal Approval references for ESP SL X Series: IECEx SIR 0.000X, Sira 0ATEX06X Application Use these protectors in hazardous environments where installation space is at a premium and large numbers of lines require protection (e.g. process control, -0 ma loops, fire and gas detectors and shut-down systems). Suitable for high speed digital communication equipment or systems with long signal lines. See Furse Application Note AN0. Installation Connect in series with the data communication or signal line either near where it enters or leaves the building or close to the equipment being protected (e.g. within its control panel). Either way, it must be very close to the system s earth star point. Install protectors either within an existing cabinet/cubicle or in a separate enclosure. LINE LINE Lightning Barrier Accessories Replacement modules: ESP SL5X/M, ESP0X/M Standard module replacement for 5 and 0 V protectors respectively ESP SL5XL/M, ESP0XL/M LED module replacement for 5 and 0 V protectors respectively ESP SLX/B Base replacement (common for standard and LED modules) ESP SLX/I/B Base replacement with isolated screen from earth S From line line Furse Wilford Road, Clean S To To equipment NOTE: Use the standard ESP SL Slim Line Series for non-hazardous areas. The ESP SL Series is also available for protection of -wire, RS 85, RTD & telecommunication applications (ESP SL/W, ESP SL RS85, ESP SL RTD & ESP SL TN). / Total Solution to ing & Lightning Protection LITGB 05

ESP SL X Series ESP SL X Series - Technical specification Electrical Specification ESP SL5X ESP SL0X Nominal voltage () 5 V 0 V Maximum working voltage Uc () 6.7 V 6.7 V Current rating (signal) 750 ma In-line resistance (per line ±0%).0 Ω Bandwidth (- db 50 Ω system) 5 MHz Intrinsically Safe Specification ESP SL5X ESP SL0X Maximum voltage U i 0 V Maximum power P i : Per -0 ºC < Ta < 0 ºC. W Per -0 ºC < Ta < 60 ºC. W Per -0 ºC < Ta < 80 ºC.0 W Capacitance C i 0 μf Inductance L i 0 μh Certificate number IECEx SIR 0.000X, Sira 0ATEX06X Classification Ex II () G, Ex ia (ia Ga) IIC T Gb Transient Specification ESP SL5X ESP SL0X Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-8. V 6.0 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-9. V 5. V B test kv 0/700 μs to BS EN/EN/IEC 66-6.8 V 5. V 5 kv, 0/700 μs () 7.5 V 6. V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair.5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP SL5X ESP SL0X Temperature range -0 to +80 C Connection type Screw terminal Conductor size (stranded) mm connection Via DIN rail or mm earth terminal Case material FR polycarbonate UL9 V-0 Weight: Unit 0.08 kg Packaged (per 0) 0.85 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa () Maximum working voltage (DC or AC peak) measured at < ma leakage () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5, Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 0.6 mm 06.5 mm 7 mm S S E Total Solution to ing & Lightning Protection LITGB 05 /5

Line Current rating In-line resistance Nottingham, NG EB, UK 0V 6.7V 750mA.0Ω 0kA 6V Data & signal protection ESP SL LED -0 ma Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair -0 ma loop systems with innovative LED protector status indication. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment (e.g. transmitters, monitors, controllers). Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Innovative LED indication of protection status provides easy visual checking and quick maintenance Ultra slim 7 mm width ideal for compact protection of large numbers of lines (e.g. process control installations) Two stage removable protection module with simple quick release mechanism allowing partial removal for easy line commissioning and maintenance as well as full removal for protection replacement Very low ( Ω) in-line resistance for minimal system interference High (75 ma) maximum running current - can also be used on 0-50 ma systems (e.g. process control) Screen terminal enables easy connection of cable screen to earth Strong, flame retardant, polycarbonate housing Built-in innovative DIN rail foot with locking feature for simple positioning and clip-on mounting to top hat DIN rails mm terminals allow for larger cross section wiring, stranded wires terminated with ferrules or fitting two wires into a single terminal Convenient earthing through DIN foot and/or earth terminal Application Use these protectors on -0 ma loop systems - ideal where installation space is at a premium and large numbers of lines require protection, or for systems with long signal lines. Installation Connect in series with the -0 ma current loop either near where it enters or leaves the building or close to the equipment being protected (e.g. within its control panel). Either way, it must be very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories ESP SL0L/-0/M Module replacement ESP SL/B Base replacement S TECHNICAL NOTE: -0 ma current loops can serve multiple devices over a long distance. The devices and wiring produce a voltage drop (also known as loop drops ) but these do not reduce the -0 ma current as long as the power supply voltage is greater than the sum of the voltage drops around the loop at the maximum signalling current of 0 ma. For design considerations, each ESP SL0L/-0 device installed within the loop introduces a.7 V loop drop. LINE LINE From line line Lightning Barrier Nominal voltage Max working voltage, U c Max surge current Let-through voltage, U p Furse Wilford Road, Clean S To To equipment NOTE: The ESP SL Slim Line Series is also available for protection of systems up to 0 V as well as -wire, RS 85, RTD & telecommunication applications (ESP SL/W, ESP SL RS85, ESP SL RTD & ESP SL TN). The ESP SL X Series has approvals for use in hazardous areas. /6 Total Solution to ing & Lightning Protection LITGB 05

ESP SL LED -0 ma Series ESP NEW SL LED -0 ma Series - Technical specification Electrical Specification Nominal voltage () Maximum working voltage Uc () Current rating (signal) () In-line resistance (per line ±0%) Series voltage drop () ESP SL0L/-0 0 V 6.7 V 75 ma.0 Ω.7 V Transient Specification ESP SL0L/-0 Let-through voltage (all conductors) (5) Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-6.0 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-5. V B test kv 0/700 μs to BS EN/EN/IEC 66-5. V 5 kv, 0/700 μs (6) 6. V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair.5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP SL0L/-0 Temperature range -0 to +80 C Connection type Screw terminal Conductor size (stranded) mm connection Via DIN rail or mm earth terminal Case material FR polycarbonate UL9 V-0 Weight: Unit 0.08 kg Packaged (per 0) 0.85 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa () Maximum working voltage (DC or AC peak) measured at < ma leakage () The minimum current for LED indicator operation is ma () At 0 ma (5) The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns (6) Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5, Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 06.5 mm 0.6 mm 7 mm S S E Total Solution to ing & Lightning Protection LITGB 05 /7

Line Current rating In-line resistance Max surge current Let- through voltage, Up Furse Wilford Road, Nottingham, NG EB, UK 0V 7.8V 750mA.0Ω 0kA.5V Data & signal protection ESP SL -Wire Series Combined Category D, C, B tested protector (to BS EN 66) suitable for -wire signalling applications which require either a lower in-line resistance, an increased current and/or higher bandwidth. Also suitable for DC power applications less than 0.5 Amps. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Ultra slim 7 mm width ideal for compact protection of large numbers of lines (e.g. process control installations) Two stage removable protection module with simple quick release mechanism allowing partial removal for easy line commissioning and maintenance as well as full removal for protection replacement Very low ( Ω) in-line resistance allows resistance critical applications (e.g. alarm loops) to be protected High (500 ma) maximum running current High bandwidth enables higher frequency (high traffic or bit rate) data communications Strong, flame retardant, polycarbonate housing Built-in innovative DIN rail foot with locking feature for simple positioning and clip-on mounting to top hat DIN rails mm terminals allow for larger cross section wiring, stranded wires terminated with ferrules or fitting two wires into a single terminal Convenient earthing through DIN foot and/or earth terminal Application Use these protectors for -wire systems where installation space is at a premium and large numbers of lines require protection (e.g. process control, high speed digital communication equipment or systems with long signal lines). Installation Connect in series with the data communication or signal line either near where it enters or leaves the building or close to the equipment being protected (e.g. within its control panel). Either way, it must be very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories Replacement modules: ESP SLXX/W/M Standard module replacement where XX is voltage rating (06, 5, 0, 50 or 0) LINE LINE Lightning Barrier Nominal voltage Max working voltage, Uc ESP SL/W/B Base replacement Clean 5 6 From From line line To To equipment NOTE: The ESP SL Slim Line Series is also available for protection of -wire systems up to 0 V, RS 85, RTD and telecommunication applications (ESP SL Series, ESP SL RS85, ESP SL RTD and ESP SL TN). The ESP SL X Series has approvals for use in hazardous areas. /8 Total Solution to ing & Lightning Protection LITGB 05

ESP SL -Wire Series ESP SL -Wire Series - Technical specification Electrical Specification ESP SL06/W ESP SL5/W ESP SL0/W ESP SL50/W ESP SL0/W Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 6.7 V 6.7 V 56.7 V V Current rating (signal) 500 ma In-line resistance (per line ±0%).0 Ω Series voltage drop 5 MHz Transient Specification ESP SL06/W ESP SL5/W ESP SL0/W ESP SL50/W ESP SL0/W Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-6.0 V 8. V 6.0 V 90. V 85 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-6. V 9. V 5. V 77. V 75 V B test kv 0/700 μs to BS EN/EN/IEC 66-6.0 V 6.8 V 5. V 68. V 65 V 5 kv, 0/700 μs () 7.0 V 7.5 V 6. V 69. V 70 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair.5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP SL06/W ESP SL5/W ESP SL0/W ESP SL50/W ESP SL0/W Temperature range -0 to +80 C Connection type Screw terminal Conductor size (stranded) mm connection Via DIN rail or mm earth terminal Case material FR polycarbonate UL9 V-0 Weight: Unit 0.08 kg Packaged (per 0) 0.85 kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa (ESP SL5/W, ESP SL0/W, ESP SL50/W, ESP SL0/W) and < 00 μa (ESP SL06/W) () Maximum working voltage (DC or AC peak) measured at < ma leakage () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5, Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 06.5 mm 0.6 mm 7 mm S S E Total Solution to ing & Lightning Protection LITGB 05 /9

ESP Q & TNQ Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair lines. Available for working voltages of up to 6, 5, 0, 50 and 0 Volts. ESP TNQ suitable for Broadband, POTS, dial-up, T/E, lease line and *DSL telephone applications. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Almost twice as space efficient as smallest competitor Standard DIN module (8 mm) depth Removable (plug-in) terminals allow pre-wiring of cable looms, for easier installation Suitable for earthed or isolated screen systems Built-in DIN rail foot for clip-on mounting to top hat or G DIN rails Optional flat mounting on side.5 mm terminals allow for larger cross section wiring, stranded wires terminated with ferrules or fitting two wires into a single terminal Very low resistance to minimise unwanted signal strength reductions Strong, flame retardant, ABS housing Colour coded terminals (grey for line, green for clean) give a quick and easy installation check Screen terminal enables easy connection of cable screen to earth Simple, yet substantial, connection to earth via DIN rail ESP TNQ is suitable for telecommunication applications in accordance with Telcordia and ANSI Standards (see Application Note AN005) Available as a UL Listed version, add /UL to part code (ESP 06Q, ESP 5Q, ESP 0Q and ESP 50Q only) Application Use these protectors where installation space is at a premium and large numbers of lines require protection. Installation Connect in series with the signal or data line either near where it enters or leaves the building or close to the equipment being protected. Install in a cabinet/cubicle close to the system s earth star point. Accessories For suitable enclosures for the ESP Q & TNQ Series, please contact us. ESP 06Q, ESP 5Q, ESP 0Q, ESP 50Q, ESP 0Q and ESP TNQ installed in series (in-line) DIRTY From line To equipment NOTE: The ESP Q Series is also available for protection of RS 85 and RTD applications (ESP RS85Q, ESP RTDQ). Protectors for individual data and signal lines are available (ESP D Series and Slim Line ESP SL Series), or ready-boxed to IP66 (ESP **D/BX etc). Alternatively, for individual protectors with higher current or bandwidth use the ESP E and ESP H Series. /0 Total Solution to ing & Lightning Protection LITGB 05

ESP Q & TNQ Series ESP Q & TNQ Series - Technical specification Electrical Specification ESP 06Q ESP 5Q ESP 0Q ESP 50Q ESP 0Q ESP TNQ Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 8.8 V 7.8 V 57.8 V V 96 V Current rating (signal) 750 ma 750 ma 750 ma 750 ma 750 ma 00 ma In-line resistance (per line ±0%).0 Ω.0 Ω.0 Ω.0 Ω.0 Ω. Ω Bandwidth (- db 50 Ω system) MHz.5 MHz 6 MHz 5 MHz 5 MHz 0 MHz Transient Specification ESP 06Q ESP 5Q ESP 0Q ESP 50Q ESP 0Q ESP TNQ Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-5.0 V 8.0 V 5.0 V 8.0 V 88 V 95 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-.5 V 6.5 V 8.0 V 76.0 V 75 V 90 V B test kv 0/700 μs to BS EN/EN/IEC 66-0.0 V.0 V.5 V 6.5 V 5 V 98 V 5 kv, 0/700 μs () 0.8 V 6. V. V 65.8 V 50 V 00 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP 06Q ESP 5Q ESP 0Q ESP 50Q ESP 0Q ESP TNQ Temperature range -0 to +80 C Connection type Pluggable way screw terminal Conductor size (stranded).5 mm connection Via DIN rail or M5 threaded hole in base of unit Case material ABS UL9 V-0 Weight: Unit 0. kg Packaged (each) 0. kg Packaged (per 0). kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 5 μa (ESP 5Q, ESP 0Q, ESP 50Q, ESP 0Q) and < 00 μa (ESP 06Q) () Maximum working voltage (DC or AC peak) measured at < 5 ma leakage (ESP 5Q, ESP 0Q, ESP 50Q, ESP 0Q) and 95 mm < 0 μa (ESP TNQ) () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns M clearance Depth: 8 mm () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5, Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 87 mm 69 mm mm Total Solution to ing & Lightning Protection LITGB 05 /

ESP KS & KE Series Combined Category D, C, B tested protector (to BS EN 66) suitable for use on ten line LSA-PLUS disconnection modules to protect individual twisted pair data or signal lines. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Low cost protection for large numbers of data and signal lines Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Quick and easy plug-in installation Colour of housing distinguishes electrically different protectors to help avoid confusion when installed with other protectors (e.g. the ESP KT/) on the same distribution frame Protect only the lines you need Ridged finger holds make it easy to obtain a firm grip for installation or removal Use the ESP KE0 to provide trouble free earthing for up to ten protectors (per disconnection module) Application Use these units to protect signal, data, control and instrumentation systems with LSA-PLUS disconnection modules. Installation Install protectors on all data communication and signal lines that enter or leave each building. All protectors must be installed via the ESP KE0 earth bar. Identify the lines requiring protection and clip the ESP KE0 on to the disconnection modules earth points. Plug the protector directly into each disconnection module requiring protection (ensuring the correct orientation) for a series connection. In the unlikely situation that the protector is damaged, it will sacrifice itself and fail short circuit, taking the line out of commission. In addition to indicating that the protector needs replacing, this will also prevent subsequent transients from damaging the equipment. NOTE: For PSTN and U interface ISDN lines on LSA-PLUS modules, use the ESP KT or ESP K0T. For S/T interface ISDN lines on LSA-PLUS modules, use the ESP KT or ESP K0T. For individual twisted pair data or signal lines, use the ESP D, E or H Series Lightning Barriers. The ESP SL and ESP Q Series Lightning Barriers are suitable for high density data and signal lines. / Total Solution to ing & Lightning Protection LITGB 05

ESP KS & KE Series ESP KS & KE Series - Technical specification Electrical Specification ESP KS06 ESP KS5 ESP KS0 ESP KS50 Nominal voltage () 6 V 5 V 0 V 50 V Maximum working voltage Uc () 7.79 V 6.7 V. V 58 V Current rating (signal) 50 ma In-line resistance (per line ±0%) Ω Ω Ω Ω Bandwidth (- db 50 Ω system) MHz 5 MHz 5 MHz 5 MHz Transient Specification ESP KS06 ESP KS5 ESP KS0 ESP KS50 Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-6.0 V 6.5 V 8.0 V 98.0 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-.5 V.0 V 6.5 V 8.5 V B test kv 0/700 μs to BS EN/EN/IEC 66-.5 V.0 V 5.0 V 75.0 V 5 kv, 0/700 μs ().0 V. V 8.8 V 80.0 V Maximum surge current (5) D test 0/50 μs to Per signal wire ka BS EN/EN/IEC 66-: Per pair ka 8/0 μs to ITU-T K.5:00, Per signal wire 5 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP KS06 ESP KS ESP KS0 ESP KS50 ESP KE0 Temperature range -0 to +80 C Connection type To LSA-PLUS disconnection modules (BT part number 7A) connection Via ESP KE0 earth bar Material ABS UL9 V-0 Stainless Steel Weight: Unit 0.0 kg 0.0 kg Dimensions Packaged 0.0 kg (per 0) 0. kg (per 0) () Nominal voltage (DC or AC peak) at 00 μa for ESP KS06 and at 5 μa for ESP KS5, ESP KS0 and ESP KS50 () Maximum working voltage (DC or AC peak) at 0 ma for ESP KS06, at ma for ESP KS5 and ESP KS0, and at 5 μa for ESP KS50. () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5, Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) (5) The installation and connections external to the protector may limit the capability of the protector See diagram below 5 mm mm 0 mm 9.5 mm 0 mm 0 mm Depth: mm Total Solution to ing & Lightning Protection LITGB 05 /

ESP PCB/D & PCB/TN Series Combined Category D, C, B tested protector (to BS EN 66) for through hole mounting directly onto the PCB of data communication, signal or telephone equipment. Available for working voltages of up to 0 Volts. ESP PCB/TN suitable for Broadband, POTS, dial-up, T/E, lease line and *DSL telephone applications. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Suitable for wave soldering Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Low in-line resistance minimises unnecessary reductions in signal strength pin clean end and pin line end to ensure correct insertion ESP PCB/TN is suitable for telecommunication applications in accordance with Telcordia and ANSI Standards (see Application Note AN005) Installation Connect in series, soldering pins direct onto PCB. Tracks to line and earth pins should be as wide as practical (see Furse Application Note AN00). Dirty (line) tracks should be routed parallel and as close together as possible. This should also be implemented on clean tracks, however clean tracks should never be routed close and parallel to line tracks or dirty barrier earth connections as transients can be re-introduced after the protector due to electromagnetic coupling. The use of an earth layer or plane is highly recommended as this reduces the electromagnetic field produced by a transient discharging to earth considerably, and hence the chance of the transient being picked up on clean tracks. Maximum line to clean separation. Large input tracks and pads (using top and bottom copper layers). pin is bonded to an earth layer/plane. All dirty (line) incoming tracks are separated from the clean output tracks, individual line and clean tracks are routed close together. pins are bonded to an earth layer/plane. Line LINE Clean ESP PCB/** Line LINE ESP PCB/** Clean Clean / Total Solution to ing & Lightning Protection LITGB 05

ESP PCB/D & PCB/TN Series ESP PCB/D & PCB/TN Series - Technical specification Electrical Specification ESP PCB/06D ESP PCB/5D ESP PCB/0D ESP PCB/50D ESP PCB/0D ESP PCB/TN Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 9 V 7. V 58 V V 96 V Current rating (signal) 00 ma In-line resistance (per line ±0%) 9. Ω 9. Ω 9. Ω 9. Ω 9. Ω. Ω Bandwidth (- db 50 Ω system) 800 khz.5 MHz MHz 6 MHz 9 MHz 0 MHz Transient Specification ESP PCB/06D ESP PCB/5D ESP PCB/0D ESP PCB/50D ESP PCB/0D ESP PCB/TN Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-.0 V 5.0 V.0 V 78.0 V 55 V 95 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-.5 V.5 V.5 V 76.0 V 50 V 90 V B test kv 0/700 μs to BS EN/EN/IEC 66-0.0 V.0 V.5 V 7.0 V 5 V 98 V 5 kv, 0/700 μs () 0.5 V.8 V. V 7.9 V 50 V 00 V Maximum surge current (5) D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP PCB/D & PCB/TN Series Temperature range -0 to +80 C Connection type 0.6 mm (0.05 ) square PCB pins,. mm diameter PCB holes recommended Case Material ABS UL9 V-0 Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 5 μa (ESP PCB/5D, ESP PCB/0D, ESP PCB/50D, ESP PCB/0D) and <00 μa (ESP PCB/06D) () Maximum working voltage (DC or AC peak) measured at < ma leakage (ESP PCB/5D, ESP PCB/0D, ESP PCB/50D, ESP PCB/0D), < 0 ma (ESP PCB/06D) and < 0 μa (ESP PCB/TN) () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5,Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) (5) The installation and connections external to the protector may limit the capability of the protector 0 mm (~ / ) 5.08 mm (0. ) 0 mm (~ / ) 5.08 mm (0. ) 5.08 mm (0. ).86 mm (0.9 ) Depth: 0 mm (~0.8 ) Weight: 5 g Pins are positioned centrally Pin connects through Pin Pin connects through Pin (Underside pin view) Total Solution to ing & Lightning Protection LITGB 05 /5

ESP PCB/E Series Combined Category D, C, B tested protector (to BS EN 66) for through hole mounting directly onto the PCB of data communication, signal or telephone equipment which require a lower in-line resistance, an increased current or a higher bandwidth than the PCB/**D Series. Available for working voltages of up to 0 Volts for AC & DC power applications up to 5 Amps. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ to protect sensitive electronic equipment. Features & benefits Suitable for wave soldering Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Very low ( Ω) in-line resistance for resistance critical applications High (.5 A) maximum running current Higher bandwidth enables higher frequency data communications pin clean end and pin line end to ensure correct insertion Installation Connect in series, soldering pins direct onto PCB. Tracks to line and earth pins should be as wide as practical (see Furse Application Note AN00). Dirty (line) tracks should be routed parallel and as close together as possible. This should also be implemented on clean tracks, however clean tracks should never be routed close and parallel to line tracks or dirty barrier earth connections as earth connections as transients can be re-introduced after the protector due to electromagnetic coupling. The use of an earth layer or plane is highly recommended as this reduces the electromagnetic field produced by a transient discharging to earth considerably, and hence the chance of the transient being picked up on clean tracks. Maximum line to clean separation. Large input tracks and pads (using top and bottom copper layers). pin is bonded to an earth layer/plane. All dirty (line) incoming tracks are separated from the clean output tracks, individual line and clean tracks are routed close together. pins are bonded to an earth layer/plane. Line LINE Clean Line LINE ESP PCB/** ESP PCB/** Clean Clean /6 Total Solution to ing & Lightning Protection LITGB 05

ESP PCB/E Series ESP PCB/E Series - Technical specification Electrical Specification ESP PCB/06E ESP PCB/5E ESP PCB/0E ESP PCB/50E ESP PCB/0E Nominal voltage () 6 V 5 V 0 V 50 V 0 V Maximum working voltage Uc () 7.79 V 6.7 V 6.7 V 56.7 V V Current rating (signal).5 A In-line resistance (per line ±0%).0 Ω Bandwidth (- db 50 Ω system) 5 MHz Transient Specification ESP PCB/06E ESP PCB/5E ESP PCB/0E ESP PCB/50E ESP PCB/0E Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-6.0 V 9.0 V 60.0 V 86.0 V 80 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-6. V 8.0 V 9.0 V 7.5 V 70 V B test kv 0/700 μs to BS EN/EN/IEC 66-6.0 V 5.5 V.5 V 65.0 V 60 V 5 kv, 0/700 μs () 7.0 V 6. V. V 65.8 V 65 V Maximum surge current (5) D test 0/50 μs to Per signal wire.5 ka BS EN/EN/IEC 66-: Per pair 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP PCB/E Series Temperature range -0 to +80 C Connection type 0.6 mm (0.05 ) square PCB pins,. mm diameter PCB holes recommended Case Material ABS UL9 V-0 Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 0 μa (ESP PCB/5E, ESP PCB/0E, ESP PCB/50E, ESP PCB/0E) and < 00 μa (ESP PCB/06E) () Maximum working voltage (DC or AC peak) measured at < 5 ma leakage (ESP PCB/5E, ESP PCB/0E, ESP PCB/50E, ESP PCB/0E), < 0 ma (ESP PCB/06E) () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, both polarities. Response time < 0 ns () Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, K. and K.5,Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68). (5) The installation and connections external to the protector may limit the capability of the protector 0 mm (~ / ) 5.08 mm (0. ) 0 mm (~ / ) 5.08 mm (0. ) 5.08 mm (0. ).86 mm (0.9 ) Depth: 0 mm (~0.8 ) Weight: 5 g Pins are positioned centrally Pin connects through Pin Pin connects through Pin (Underside pin view) Total Solution to ing & Lightning Protection LITGB 05 /7

Line Current rating In-line resistance Nottingham, NG EB, UK 0V 7.8V 750mA.0Ω 0kA.5V Data & signal protection ESP RTD, RTDQ & SL RTD Series LPZ RTD 0 A RTDQ 0 A SL RTD 0 B Combined Category D, C, B tested protector (to BS EN 66) suitable for -wire RTD systems to protect monitoring equipment. For use at boundaries up to LPZ 0 (ESP RTD & ESP RTDQ) or LPZ 0 (ESP SL RTD) to protect against flashover (typically the service entrance location) through to LPZ. Available as standard ESP RTD format, or compact ESP RTDQ and Slim Line ESP SL RTD versions for installations where a high number of lines require protection. Features & benefits Protects all three wires on a -wire RTD system with a single protector Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Low in-line resistance minimises reductions in signal strength Built-in DIN rail foot for simple mounting to top hat DIN rails Convenient earthing through DIN foot and/or earth terminal ESP RTD can be flat mounted on base or side ESP RTD and ESP RTDQ have colour coded terminals for quick and easy installation check ESP SL RTD has ultra slim 7 mm width ideal for compact protection of large numbers of lines (e.g. process control installations) ESP SL RTD includes two stage removable protection module with simple quick release mechanism allowing partial removal for easy line commissioning and maintenance as well as full removal for protection replacement For further information on RTD applications, see separate Application Note AN00 (contact us for a copy). Installation Connect in series with the signal line either near where it enters or leaves the building or close to the equipment being protected ensuring it is very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories Replacement module for ESP SL RTD: ESP SLRTD/M Standard module replacement ESP SLRTD/B Base replacement Combined Mounting/ing kits for ESP RTD: CME For up to x ESP RTD CME 8 For up to 8 x ESP RTD CME 6 For up to 6 x ESP RTD CME For up to x ESP RTD ESP RTD installed in series DIRTY From line To equipment ESP RTDQ installed in series (in-line) DIRTY ESP SL RTD installed in series LINE LINE From From line line Lightning Barrier Nominal voltage Max working voltage, Uc Max surge current Let- through voltage, Up Furse Wilford Road, Clean 5 6 To To equipment From line To equipment NOTE: For -wire or -wire RTD applications, use one or two ESP 06D or ESP SL06 protectors respectively. /8 Total Solution to ing & Lightning Protection LITGB 05

ESP RTD, RTDQ & SL RTD Series ESP RTD, RTDQ & SL RTD Series - Technical specification Electrical Specification ESP RTD ESP SL RTD ESP RTDQ Nominal voltage () 6 V Maximum working voltage Uc () 7.79 V Current rating (signal) 00 ma 500 ma 700 ma In-line resistance (per line ±0%) 0 Ω.0 Ω.0 Ω Bandwidth (- db 50 Ω system) 800 khz.5 MHz 800 khz Transient Specification ESP RTD ESP SL RTD ESP RTDQ Let-through voltage (all conductors) () Up C test kv./50 μs, ka 8/0 μs to BS EN/EN/IEC 66-.0 V 7.9 V 5.0 V C test kv,./50 μs, 0.5 ka 8/0 μs to BS EN/EN/IEC 66-.5 V. V.5 V B test kv 0/700 μs to BS EN/EN/IEC 66-0.0 V.0 V 0.0 V 5 kv, 0/700 μs () 0.5 V. V 0.5 V Maximum surge current D test 0/50 μs to Per signal wire.5 ka.5 ka.5 ka BS EN/EN/IEC 66-: Per pair 5 ka.5 ka 5 ka 8/0 μs to ITU-T K.5:00, Per signal wire 0 ka IEEE C6..:00: Per pair 0 ka Mechanical Specification ESP RTD ESP SL RTD ESP RTDQ Temperature range -0 to +80 ºC Connection type Screw terminal Pluggable way screw terminal Conductor size (stranded).5 mm mm.5 mm connection M6 stud Via DIN rail or mm earth terminal Via DIN rail or M5 threaded hole in base of unit Case Material ABS UL9 V-0 FR polycarbonate UL9 V-0 ABS UL9 V-0 Weight: Unit 0.08 kg 0.08 kg 0. kg Packaged (per 0) 0.85 kg 0.85 kg. kg Dimensions See diagram below () Nominal voltage (DC or AC peak) measured at < 00 μa () Maximum working voltage (DC or AC peak) measured at < 0 ma () The maximum transient voltage let-through of the protector throughout the test (±0%), line to line & line to earth, ESP RTD ESP RTDQ 95 mm both polarities. Response time < 0 ns 5 mm M clearance () 8 mm Test to IEC 6000--5:006, ITU-T (formerly CCITT) K.0, Depth: 8 mm K. and K.5,Telcordia GR-089-CORE, Issue :00, ANSI TIA/EIA/IS-968-A:00 (formerly FCC Part 68) 87 mm 05 mm M clearance 69 mm 0 mm mm 9 mm 09 mm M clearance ESP SL RTD 0.6 mm 06.5 mm 7 mm S S E Total Solution to ing & Lightning Protection LITGB 05 /9

Line Current rating In-line resistance Nottingham, NG EB, UK 0V 6.7V 750mA.0Ω 0kA 6V Data & signal protection ESP RS85, RS85Q & SL RS85 Series LPZ RTD 0 A RTDQ 0 A SL RTD 0 B Combined Category D, C, B tested protector (to BS EN 66) specifically designed for RS 85 and Fieldbus applications, such as Profibus DP. For use at boundaries up to LPZ 0 (ESP RS85 & ESP RS85Q), or LPZ 0 (ESP SL RS85) protect against flashover (typically the service entrance location) through to LPZ. Available as standard ESP RS85 format, or compact ESP RS85Q and Slim Line ESP SL RS85 versions for installations where a high number of lines require protection. Features & benefits Very low let-through voltage (enhanced protection to BS EN 605) between all lines - Full Mode protection Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Repeated protection in lightning intense environments 5 MHz bandwidth greatly exceeds Mbps maximum speeds Low in-line resistance minimises reductions in signal strength Suitable for earthed or isolated screen systems Built-in DIN rail foot for simple mounting to top hat DIN rails Convenient earthing through DIN foot and/or earth terminal ESP RS85 can be flat mounted on base or side ESP RS85 and ESP RS85Q have colour coded terminals for quick and easy installation check ESP SL RS85 has ultra slim 7mm width ideal for compact protection of large numbers of lines (e.g. process control installations) ESP SL RS85 includes two stage removable protection module with simple quick release mechanism allowing partial removal for easy line commissioning and maintenance as well as full removal for protection replacement ESP SL RS85 includes optional LED status indication - add L suffix to part number - i.e. ESP SL RS85L Application Connect in series with the signal line either near where it enters or leaves the building or close to the equipment being protected ensuring it is very close to the system s earth star point. Install protectors either within an existing cabinet/ cubicle or in a separate enclosure. Accessories Replacement module for ESP SL RS85: ESP SLRS85/M Standard module replacement ESP SLRS85/B Base replacement Combined Mounting/ing kits for ESP RS85: CME For up to x ESP RS85 CME 8 For up to 8 x ESP RS85 CME 6 For up to 6 x ESP RS85 CME For up to x ESP RS85 ESP RS85 installed in series ESP SL RS85 installed in series ESP RS85Q installed in series (in-line) DIRTY LINE LINE Lightning Barrier DIRTY From line ESP RS85 ESP RS85 To equipment S Nominal voltage Max working voltage, U c Max surge current Let-through voltage, U p Furse Wilford Road, Clean S From line To equipment From line line To To equipment NOTE: The ESP SL Slim Line Series is also available for protection of -wire and RTD applications (ESP SL/W & ESP SL RTD). The ESP SL X Series has approvals for use in hazardous areas. /0 Total Solution to ing & Lightning Protection LITGB 05