Installation & Calibration Manual

Similar documents
Installation & Calibration Manual

ivisibility (Keypad Operator Access Control Series) Lift Truck Onboard Automatic Detection / Recording of All Operational Downtime Events

Installation & Calibration Manual

Defender IM4-RFID Lift Truck Impact Monitoring with RFID Card Reader Operator Access Control with Automated Programmable OSHA Safety Check RF Wireless

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

xtablet T1600 Vehicle Holder Installation Guide

NR-TEC S2S SURFACE TO SANDFACE DATA LOGGER

NNG-Ford V1 NTV-KIT558. Navigation interface for FORD vehicles equipped with 8.4 MyTouch NTV-DOC218

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

User Manual. SmartWave LF Tool. PN: Revision 1.1. Copyright 2009 Bendix CVS Canada Inc.

Parts Identification Page 1 Vehicle Preparation Page 3 Programming Switch Settings Page 3 Installation Page 4. Form #5420,

VERSA REMOTE TM FULL FEATURED REMOTE CONTROL SYSTEM OPERATIONS AND INSTALLATION MANUAL

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

The Power Systems Industry Experts. Installation Instructions. PT400 Stationary Generator Monitoring System

Quick Start Guide MC-III TM Flow Analyzer

NIDEC-SHIMPO INSTRUMENTS

RADI-CEM. User manual. MPB S.r.l. Via Giacomo Peroni 400/ Rome - Italy. Tel Fax

CONTENTS 1 V600 OWNER S MANUAL

FUSION MS-RA70/MS-RA70N Installation Instructions

INSTALERT VARIABLE MESSAGE SIGN

W1258 LOAD MOMENT INDICATOR OPERATORS MANUAL. Version 1.0 Serial No.: 55M1258COE. United States Canada Great Britain

Installation Instructions

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

TC200 Operation & Installation Guide. Revision 1.0

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Installation & Operation Manual Revision 2

Gauge Mount Radio PRIMARY FEATURES. Marine & Powersports Bluetooth Source Units

SiriusXM Satellite Radio interface

SERVICE PARTS MANUAL

User Guide. Parrot MKi9000. English. Parrot MKi9000 User guide 1

Flow Chart Programming Instructions for : Pressure 2 1/16 PROFESSIONAL RACING GAUGE START HERE PROGRAM MAIN MENU

Thank you for purchasing Parrot CK3000, the hands-free kit with voice recognition equipped with Bluetooth TM radio technology.

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

CS 140RC. Joystick Controller Configuration and Set-up Manual

PM Series Power Meter

LOADMAN. LM400 Touch User Guide

GEN 6 LOCKPICK INSTALLATION OPTIONS COPYRIGHT 2010 COASTAL ELECTRONIC TECHNOLOGIES, INC.

Installation Instructions

Mounting DIGITAL DISPLAY

Power connections 3) Power from 2024 to Control box (The valve harness connected) Ground (0V) +24 V. The voltage between pins 1 & 2 in JPT# 123

INSTALLATION INSTRUCTIONS

Please read thoroughly before starting installation and check that kit contents are complete.

INSTALLATION INSTRUCTIONS

Unit Test Calibration Training. (QL420+ & RW420) Mobile Printers

9-3 M03-06, radio/navigation... page M07-, radio... page M07-, navigation... page M06-, radio/navigation...

SERVICE PARTS MANUAL

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

SUN2000-(55KTL, 60KTL) Series Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Sync KIT SYSTEM INSTALLATION

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

TECHNICAL SERVICE BULLETIN

GSMR20 OWNER S MANUAL

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION MASKING TAPE

Digital Proportional Valve Amplifier

HawkEye 45T Display User Manual

Adjustable Timing Control PN 8680

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

NCSP35. Installation and Operation Manual RV CONTROL AND MONITORING SYSTEM. Patent # US 9,679,735

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

MS30. Owner s Manual + FOLDER VOL+ VOL- >ll MUTE. >>l. l<< MS30 MODE FOLDER

Digital Keypad Introduction

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

fi-7180/ fi-7160/ fi-7260/ fi-7280 Getting Started Image Scanner Checking the Components P3PC EN

B&W RearView Camera Installation & Operation

Classic edition OWNERS MANUAL

P522 Signal Processor

ARTiPRO. User Manual. (Model 910 & 920)

Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL. For the 4600 Scale System For the 5600 Scale System

GM2 FIM LOCKPICK INSTALLATION OPTIONS COPYRIGHT 2012 COASTAL ELECTRONIC TECHNOLOGIES, INC.

SUN2000-(33KTL, 40KTL) Quick Installation Guide. Issue: 05 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

RS2 X 2 With you on the front line

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

PS-IN202 Weighing Indicator User Manual

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

Vision Fitness TF20-TF40-T40 Frame with Classic / Elegant / Touch Console Service Manual

Interface Module for radio Auxiliary Input. Installation & Operation

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

LTS DR2100A/AN Indicator WARRANTY POLICY

ES1624 MFP Setup and Installation Guide

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

Energy Meter and. Current Transducer. Assembly Manual

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Wireless Inspection Camera and LCD Display Instruction Manual

1.0 Description. 2.0 Unpacking. 3.0 Installation

Digital Speed Controller User Manual

VW2106 VW Readout Manual

CHAPTER 3B: ELECTRONIC POWER STEERING

Go-Baby-Go Senior Capstone Project

INSTALLATION INSTRUCTIONS

PWS500S Installation Guide

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

ViewPoint II Operator Interface

MSD Three Stage Delay Timer PN 7760

Version 1.1. A guide for BLU2 installations.

Linear Actuator Controller

Transcription:

Installation & Calibration Manual ScanWeight (System with Bluetooth module) ScanWeight-RF (System with Bluetooth and RF module) Lift Truck Onboard Check Weighing Initiated by Barcode Scanner ScanWeight V1.30

General Installation Guide This ScanWeight V1.30 Series guide describes how to install, calibrate, test and use your material handling vehicle onboard check weighing system. Following the instructions in the ADMINISTRATIVE MENU guide will enable you to get the weighing scale calibrated and the system up and running. In the event that you require additional assistance, please contact customer support via e-mail at support@skidweigh.com, visit www.skidweigh.com or contact us at the address or contact number below: Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, ON, Canada, L6L 0A7 Phone: 905-469-0985 Safety Always disconnect the vehicle battery while installing SkidWeigh system or any other electronic product. Make sure that unit, pressure transducer and any other associated cables are securely mounted and do not impede any of the vehicle s controls. Use care when routing the components cables. Route the cables where they will be protected. Use commonly accepted install practices for after market industrial vehicle electronic devices. The installation of the SkidWeigh systems should only be performed by an acknowledged lift truck dealer technician or end user electro and hydraulic technical installer. Here are two acceptable methods of making a wire connections: * Soldering your connections (recommended) * Crimp connectors ( with the use of the proper crimping tool) Regardless of the method you choose, ensure that the connection is mechanically sound and properly insulated. Use high quality electrical tape and shrink tubing where necessary. This product is connected directly to the vehicle s ignition switch, 12 to 55 VDC. There is no on-off switch on the unit. Electro-Magnetic Compatibility CE conformity to EC directive 89/336 (EMC) by application of harmonized standards: Interference stability EN 61000-6-2 and EN 61326-1 interference emit EN 61000-6-3, EN 61326-1 for the pressure transducer. ScanWeight Series Our policy is one of continuous improvement and the information in this document is subject to change without notice. The software version is displayed on the LCD display once the power is turned on to the system. Overview of components (Bluetooth scanner is Optional) The standard ScanWeight system consist of two main components: * ScanWeight indicator with Bluetooth module, wiring harness, mounting bracket and anti-vibration mount * Hydraulic pressure transducer with 3 wires cable * Installation & calibration manual and operator usage instruction

Operation The ScanWeight operation is based on the hydraulic pressure transducer mounted in the vehicle lifting circuit Pressure transducer installation The pressure transducer must be installed in the lifting hydraulic line between the lift control valve and lift cylinder(s). Mount a T-piece in lifting hydraulic line. Pressure transducer installation precautions Before installation of the pressure transducer the hydraulic lift circuit must be pressure free. Pressure transducer has 1/4-18 NPT male thread. Use thread seal to ensure tight fit. Selecting the mounting location for digital indicator Note: Use the mounting bracket with the anti vibration mount and fasten digital indicator on the vehicle dashboard. There are many examples of mounting locations that will depend on the vehicle model. However, additional mounting items such as a flat brackets may be needed to help secure digital indicator.

Electrical connections All SkidWeigh Plus systems operate from 12 to 55 VDC. - Orange Wire (+) Ignition switch - Brown Wire (-) Battery negative - Red Wire, connect to RED wire of the pressure transducer cable - Black Wire, connect to BLACK wire of the pressure transducer cable - White Wire, connect to WHITE wire of the pressure transducer cable Power short circuit protection All ScanWeight systems are internally short circuit protected with resettable fuse. There is no need to install external inline fuse in orange wire connected to the ignition switch. Bulgin USB Assembly Note: All data is recorded in excel file. Verification of the electrical connections done properly - Turn on vehicle power switch - Lower forks to the ground - Digital LCD display will be activated, showing software version and serial number - Digital LCD display will show current date and time Aug 28, 2010 12:20:23 If the above test is valid than the system electrical connections are done right. Note: To test load weight function press by pass (Green) switch and lift the load.

Bypass Barcode Scanner Function Impact Monitoring Bluetooth Icon Mounting Bracket With Anti Vibration Mounts Keypad Toggle Arrows Keys in set up menu Enter key Administrative Menu FUNCTION MODE KEY F 9 ADMINISTRATIVE MENU (Password protected) F 0 OPERATOR MENU (Bluetooth scanner pairing)

The administration menu allows the installation technician to calibrate system weighing function (Set Calibration 1), set the overload if applicable and for the end user to manage data, set vehicle ID#, input proper time and date, modify utilization factor, impacts set up menu and saving data to memory stick. Note: Data collected will depend on the hardware / software configuration. (ED3/ED4, UT10 to UT60 series) To enter into the Administration Menu, press F key and than press 9 key. Input password 521. Use left and right arrow keys to scroll for functions that might apply for your system configuration. Follow the LCD instructions, use Enter key to confirm set up input and use F key to exit. MENU Password =

<> KEY to SCROLL F KEY TO EXIT Date / Time Set Up SET CLOCK ENTER TO SELECT SET CLOCK AUTO _ Use left and right arrow key (bottom left side of the keypad) to change from AUTO to MANUAL date/ time set up. Note: AUTO set up refers to system utilizing a wireless RF platform with automatic date /time update from IVDT Base station communication and programming hub. For the applications without Base Station, use SET CLOCK MANUAL instructions. SET CLOCK MANUAL _ To set clock / date. Follow the LCD instructions and press Enter key to confirm.

Aug 28, 2010 12:20:23 Press Enter key to confirm the setting. The cursor will automatically move to the next item to be changed ( Month, Day, Year, Hours, Minutes, Seconds). On the last correction, seconds item press Enter key to confirm new date / time set up. Set vehicle ID# - Maximum input number for vehicle ID# is 3 digits. <> KEY to SCROLL F KEY TO EXIT SET VEHICLE ID ENTER TO SELECT ENTER VEHICLE ID 1_ VEHICLE ID CONFIGURATED

Saving recorded data to USB memory stick The UTX SkidWeigh Plus system will allow you to download all recorded data onto a USB drive. Follow instructions shown on the LCD display This function is located in Administrative Menu. <> KEY TO SCROLL F KEY TO EXIT SAVE TO USB ENTER TO SELECT SAVING TO USB - ERASE SDRAM? N When the system has finished uploading the data to the USB memory stick the LCD display will prompt you to erase the SDRAM, all files contained on the UTX SkidWeigh Plus. Make selection Y or N and press Enter key to confirm selection and the system will automatically bring you back to the main screen in the administrative menu. <> KEY TO SCROLL F KEY TO EXIT Print / Send Enter key

Weighing scale function calibration Make sure that forks are on the ground and LCD display is showing time and date. Aug 28, 2010 12:20:23 To enter into the Administration Menu, press F key and than press 9 key. Input password 521. MENU Password = Use left and right arrow keys to scroll for functions to calibrate weighing scale function. LIFT EMPTY FORKS Lift empty forks just above the ground. Do not manipulate the tilt, side shifter or move vehicle. After few seconds system zero weight value will be calibrated and stored. LCD will show. LOWER FORKS Lower the empty forks to the ground. The LCD display will prompt you to input known calibration load weight. (In our example the known load weight is 2000) WEIGHT _ WEIGHT = 2000

Pick up a known load weight and lower the loaded forks to the ground. Input into the system the known load weight (Our example is 2000) and press Enter key. The LCD display will show LIFT LOAD Activate lift control valve and lift loaded forks just above the ground. Do not manipulate the tilt, side shifter or move vehicle. After few seconds calibrated load weight value of 2000 will stored. Within few seconds the LCD will show. LOWER FORKS CONFIGURATED As soon the loaded forks are lowered to the ground the LCD display will show date / time. System check weighing function calibration is completed. System is ready to be used. Overload Warning Function (Optional Function) LOWER FORKS As soon forks are lowered the LCD display will show OVERLOAD = _ The LCD display will prompt you to input the overload load weight value. Input the applicable overload value and press Enter key. Press F key to exit the ADMINISTRATIVE MENU.

Lift Truck Operator Weighing Guide Loaded forks must be lowered to the ground LCD display must show date / time Use barcode scanner to initiate the weighing cycle Lift the load approximately 2 off the ground Do not use tilt, side shift or move vehicle during the weighing cycle Within few seconds LCD display will show the load weigh and barcode ID# Load weight and barcode ID# will be recorded to USB port Automatic weighing cycle is completed * NOTE: To obtain load weight only press external (Green) switch to by pass the barcode scan function The ScanWeight-RF system will send data to the USB port and base station