Panduit Basic Rack PDU with Local Meter

Similar documents
Panduit Basic Rack PDU

SmartZone Gateway- Enabled M Series Rack PDU

G5 PDU Installation Guide

SmartZone Network-Enabled MS Series Rack PDU

hp uninterruptible power system r12000 xr models installation instructions

* * Agilent Power Distribution Unit (PDU) Installation Guide

E1135C PDU and Pod Upgrade Procedure

Power Supply and Fan Module Installation

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Power Supply Installation

VRp Three-Phase Precision AC Voltage Regulator

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

M250 (M LL) Safety

Installing the Cisco MDS 9020 Fabric Switch

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

PowerLogic High Density Metering System 1-Meter Enclosure

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Liebert MicroPOD 230V

HPE Intelligent Power Distribution Unit Installation Instructions

M215 (M215-60) Safety

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Installing Cisco RP-Series PDUs

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Enphase S-Series Microinverter and Engage Cable Safety

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

M215-Z Safety Information (M LL-IG-ZC)

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

NI PXIe-1062Q Power Supply Shuttle

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Multilin EPM 4600 Metering Solution

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

Polar PDUs POWER MANAGEMENT

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Broadband Automatic Disconnect Switch. User Manual

Power Supply and Fan Module Installation

Wa r n i n g-wa r n i n g-wa r n i n g

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

Instruction Manual Basic Rack PDU VP7541 and VP9571A

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

INSTALLATION INSTRUCTIONS

GE Digital Energy Multilin EPM 4600 Quickstart Guide TELEPHONE: FAX: HOME PAGE:

Startup Guide C01

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Enphase Engage Cable and Accessories

MERCURY PRO. Assembly Manual & User Guide

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Instruction Manual. Rack PDU XP Series. geistglobal.com

Cisco CRS 16-Slot Chassis Power Systems

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Installing the Cisco AS5400XM Universal Gateway

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

Ethernet Test Access Panel (ETAP) User Manual

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

Safety Precautions Legrand PDU. 0U PDU Overview. Outlets. Circuits. Controller with Connector Ports: See Controller (on page 4).

Installation and Maintenance

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

User s Guide. POWERVAR Single Phase Power Conditioners

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Zonit μats TM Users Guide μats1-lv Version 1.2

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

LVN5200A-R2, rev. 1, Hardware Installation Guide

PM Series Power Meter

Installation Instructions & User Manual

ECM-1220 User s Manual

InView Firmware Update

DRIVE DOCK. User Guide

Installation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices

Avanti HP Series Centrifuges Preinstallation

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

SUPERSLIM. Assembly Manual & User Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

UPS USER S GUIDE kva, 50 and 60 Hz.

OilCop Component Wiring Installation Manual

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

DRIVE DOCK. User Guide

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Control Box Setup - PRSalpha

SAVE THESE INSTRUCTIONS

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

TRC-190 User s Manual

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Cisco ASR 1004 Router Overview and Installation

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Siemens Drives & PLCs

Transcription:

Panduit Basic Rack PDU with Local Meter User Manual Release 1.0 Issue 1.0

Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording or otherwise, without written permission from Panduit. No patent liability is assumed with respect to the use of the information contained herein. Although every precaution has been taken in the preparation of this book, Panduit assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. - 2 -

Table of Contents Basic Rack PDU with Local Meter 4 Contacting Panduit 4 Symbols Used 4 Equipment Overview 5 Model Numbering Format 5 Part Numbering Format 6 Pre-Installation 7 Product Inspection 7 Installation 8 Before You Begin 8 Hardwire PDU installation instructions 8 Unterminated Cord PDU installation instructions 10 Standard Accessories 10 Additional Required Items 10 Hardware 11 LCD Display 11 Reset Button 11 Mode Button Operation 11 Unit Startup 11 Unit Operation 12-3 -

Basic Rack PDU with Local Meter Panduit Basic Rack PDUs with Local Meter provide reliable power distribution to devices installed within a cabinet and have an on-unit display to allow for local monitoring of power information. This equipment has been designed for connection to an IT power distribution system. Contacting Panduit For technical support on PDU hardware and associated software, please contact Panduit Technical Support using one of the following methods: 1-866-721-5302 (toll-free), Monday-Friday, 7:30 am - 5:00 pm CST systemsupport@panduit.com Symbols Used Symbol Description Danger Electric Shock Hazard Warning Possible Safety Hazard Primary Earth Ground Secondary Earth Ground ON O OFF - 4 -

Equipment Overview The power inlet/cord(s) connects the PDU to the electrical power source. The LCD displays the current load for each input feed or electrical phase per input feed. For IEC C-20 inlet PDUs, a customer-supplied cord is used for connection to the power source. The connection end to the PDU has an IEC C-19 plug for connection to the PDU. The opposite end of the cord has a plug suitable for connecting to the customer-supplied receptacle. The cord and plug shall be rated for 20A in North America and 16A outside of North America. Make the connection to the PDU before connecting to the power source Model Numbering Format This section describes the model numbering format used to identify equipment in the PDU series. PDU model numbers are: HD-YYYVZZA HE-YYYVZZA VD-YYYVZZA VE-YYYVZZA The letters in the series represent values as defined in the table below. Letter H V D E YYY ZZ What It Represents Horizontal series Vertical series Basic - no monitoring or display provided Metered - on board display only May be any number, 120-415, representing rated voltage May be any number, 10-63, representing rated current - 5 -

Part Numbering Format This section describes the part numbering format used to identify equipment in the PDU series. PDU devices are numbered using one of the following formats: H1M-ABCDEFGHJKLM V1M-ABCDEFGHJKLM The H1M prefix indicates that the model is intended for horizontal mounting. The V1M prefix indicates that the model is intended for vertical mounting. The remaining letters in the series represent values as defined in the table below. Letter A B CD* E F GH JK L M What It Represents Any numeral, 1-8, indicating the phase wiring for the output circuit breakers and receptacles Any letter, A-F, indicating input cord configuration Any numeral, 1-5, and any letter, A-Z, indicating input plug type and rated voltage Any numeral, 1-7, indicating the number of output circuit breakers Any letter, A-Z, indicating the type of overload protection provided for the outlets Any two numerals, 01-45, indicating the number of output receptacles provided The letter A or B followed by any letter, A-Z, indicating the type and quantity of output receptacles provided Any numeral, 0-9, or any letter, A-Z, indicating the length of the power supply cord Any numeral, 0-9, indicating the color of the enclosure * Voltage and amperage ratings: 120V, single-phase, 10A, 12A, 15A, 16A, 20A, 24A or 30A 208V, single-phase, 10A, 12A, 13A, 15A, 16A, 20A, 24A, 30A, 48A or 60A 230V, single-phase, 16A, 32A, or 48A 208V, three-phase (delta), 16A, 20A, 24A, 30A, 40A, 48A, 50A or 60A, 3W + PE 208V, three-phase (wye), 16A, 20A, 24A, 30A, 48A or 60A, 3W + N + PE 400V, three-phase (wye), 16A, 20A, 24A, 30A, 32A, 48A or 60A, 3W + N + PE - 6 -

Pre-Installation The Rack PDU products covered by this guide are designed to be installed within EIA racks and cabinets. Use of this product in other applications is acceptable, but other precautions may be required to allow for specific installations not covered by this guideline. Product Inspection Inspect the product prior to installation. If the product has any visible signs of damage, please contact the supplier. - 7 -

Installation Before You Begin Before installing your PDU, refer to the following lists to ensure that you have all the items shipped with the unit as well as all other items required for proper installation. Hardwire PDU installation instructions This product is intended to be hardwired by the customer must be installed by a qualified electrician AND adhere to all national & local electrical codes. 1. To install, remove the (4) securing screws on the removable user panel. 2. Unscrew strain relief grommet cap (indicated below) and feed the power cable through the grommet cap & the input gland. 3. Ensure conductors are stripped adequately, exposing 15mm of copper. 4. Conductors shall be connected in-line with the terminal markings provided as shown below (Line 1 = X; Line 2 = Y; Line 3 Z). Ensure screws are secure for each conductor by applying a torque of 2.3 N-m (20 in-lb.). - 8 -

5. Ensure conductors have enough slack (none should be under tension). 6. Feed grommet cap down cord and secure to input gland. Reference the table below to ensure the grommet cap is torqued correctly. Gland Size Grommet Cap Torque M16 1.5 N-m (13 in-lb.) M20 M25 M32 M40 M50 M63 3.0 N-m (27 in-lb.) 4.0 N-m (35 in-lb.) 15 N-m (132 in-lb.) 20 N-m (177 in-lb.) 30 N-m (266 in-lb.) 7. Re-install removable cover plate with the screws removed in step 1. 8. Connect the other end of the power cord to a suitably rated disconnect device. 9. Switch utility circuit breaker On. - 9 -

Unterminated Cord PDU installation instructions This product is intended to be hardwired by the customer must be installed by a qualified electrician AND adhere to all national & local electrical codes. To install, match the corresponding conductor color to the matching phase in your facility. Reference the color guide below: Conductor Insulation Color Line Number / Phase Brown Line1 / X Black Grey Blue Green (may include Yellow stripe) Line 2 / Y Line 3 / Z Neutral Ground Standard Accessories Mounting hardware: Vertical models: Affixed button mounts Horizontal models: Appropriate local mounting brackets and screws Additional Required Items Flathead and Phillips screwdrivers Appropriate local AC power receptacle to power the PDU - 10 -

Hardware LCD Display On metered PDUs, the display shows the device model number, serial number, and electrical readings. The display automatically scrolls through the readings. Below are the readings that will be displayed: Start up messages Configuration/serial/product number messages Error/Status messages Aggregate data Single-Phase data, 3-Phase Delta data, or 3-Phase Wye data Branch Current data, if the unit has breakers Reset Button Push the Reset button using a non-metallic item, similar in size to a paper clip, to reset the PDU device. tool. Warning: a metallic item, such as a paper clip, is not recommended as a reset The reset tool should be inserted perpendicular to the surface of the device and pressed until the button is reached and is actuated. The reset tool should bump into the button within 1/8 of an inch of being inserted, and should be lightly depressed and held for at least 1 second. The reset tool should never be inserted more than 1/4 of an inch. Resetting the PDU device starts the bootloader. Wait between 1 and 30 seconds for the Display Backlight to blink on and off at a rate of 2 blinks per second. The bootloader stays in this mode for at least 4 seconds (8 blinks) if no user operation is detected. Mode Button Operation Unit Startup When the unit first starts up, the LCD backlight begins to blink. Avoid pressing the Mode button until the LCD finishes blinking and the display backlight turns off. - 11 -

When the application is ready, a message displays on the LCD: Starting up The display backlight blinks quickly three times and remains lit. Avoid pressing the Mode button until the firmware version is displayed. Unit Operation Once the firmware version is displayed, you can press the Mode button to move to the next display screen. - 12 -