Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)
|
|
- Marvin Turner
- 6 years ago
- Views:
Transcription
1 Faster. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with Local and Intelligent PDU mounted display option for local current or power monitoring, making phase balancing easier (the PDU itself is not phase balancing) Intelligent PDU Options and Features Remote aggregate, circuit or receptacle power monitoring for granular PUE measurement Switched (on/off) options allow remote outlet management and equipment reboot with sequential delay features; avoid power interruption due to inrush current, equipment start up in desired sequence Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based firmware with alarm or SNMP trap features prevents downtime with early notification of power threshold breaches SNMP (MIB) enabled for compatibility with all leading DCiM packages Integrated environmental monitoring capabilities; monitor temperature, air flow, humidity and dew point via optional connected sensors Internal memory for up to two week of trending of critical parameters for clear understanding of power allocation and usage PDU Firmware, Trending Page Intelligent-Remote (3) Belden PDU Local Display/ (1) Local current/amp meter, monitoring at circuit level for multi-circuit PDU. (2) Local power meter provides Amps, Volts, Watts, Volt-Amps, kwh and Power Factor. (3) Remote functions (IP-based) accessible via web browser. Current Power Circuit Level Environmental Port (4) Power Level (5) (4) Remote IP-based environmental monitoring, (2) port per PDU. Requires external sensor, refer to accessories (p. 78) for selection. (5) Remote IP-based receptacle level monitoring, Amps, Volts, Watts, kwh. (6) Remote IP-based receptacle level switching (on/off) with configurable time delay. Switched (6) Basic (B) Local (L) Current (C) (1) Power (P) (2) Power (O) (2) Switched (S) (2) Optional Power, Cooling and Air Handling Relations PDU Firmware, Alarm Setting Page Intelligent PDU Communication and Environmental Ports PDU Nameplate Current Rating (A) Branch Circuit Rating (A) Nameplate Volts (V) Volts Actual Delivered (V) Phase* PDU minal Power Watts (W) PDU De-Rated Power (W) PDU De-Rated Power (kw) PDU De-Rated Power (BTU/hr.) AC Tons** (BTU/100) Air Volume*** (1 CFM* kw) ,800 1, , ,400 1, , ,600 2, , ,160 3, , ,240 4, , ,400 7, , ,480 9, , , ,600 3, , ,900 5, , ,800 11, , ,3 16 1/ ,197 5, , / ,795 8, , , / ,992 12, , , / ,616 17, , , / ,027 28, , , / ,033 36, , , / ,040 43, , , / ,856 11, , ,3 24 2/ ,785 16, , ,992 *3-Phase power is calculated by multiplying single phase by the square root of 3 or **Tons of air conditioning required to remove heat from associated IT load. ***The volume of air that is typically required by the IT equipment for each kw of IT load can typically range from 80 to 140 CFM. 1 CFM was used for calculation BELDEN.1 ( ) 73
2 Single-Phase PDUs Front View 9LF Rear View 9LF UL Listed Single-Phase PDUs : B = Basic; L = Local Monitored 9LB De-Rated Amps (A)/ Power (kw) Volts (V) Thermal /Qty Circuit Breaker On-Off Switch Surge - Supression Local Mounting (4) 9BF B /1 5-15P R/6 Rack - 19" 17 x 1.72 x BF B /1 5-15P R/6 Rack - 19" 17 x 1.72 x BF B /1 5-15P R/8 Vertical 24 x 1.61 x LF L /1 5-15P R/10 Power Rack - 19" 17 x 1.72 x 4.5 9BF B /1 5-15P R/14 Vertical 47.5 x 1.61 x BG B 1.9 /1 L5-P 8 5-R/8 Vertical 24 x 1.61 x BG B 1.9 /1 5-P 10 5-R/10 Rack - 19" 17 x 1.72 x LG B 1.9 /1 5-P 10 5-R/10 Power Rack - 19" 17 x 1.72 x 4.5 9BG B 1.9 /1 5-P 14 5-R/14 Vertical 47.5 x 1.61 x BG B 1.9 /1 L5-P 14 5-R/14 Vertical 47.5 x x BG B 1.9 /1 L5-P 14 5-R/14 Vertical 47.5 x x BG B 1.9 /1 L5-P 14 5-R/14 Vertical 47.5 x x LH L 2.8 /1 L5-P 24 5-R/24 Magnetic Breaker Power Vertical 9LB L 5 /8 L6-P 12 C-13/12 Magnetic Breaker Power Rack - 19" 17 x 1.72 x 6.5 9LB L 5 /8 L6-P C-13/24 + C-19/6 Magnetic Breaker Power Vertical in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. exit (3) Standard PDU chassis color is black, custom color overlay Front View 9PG Rear View 9PG UL Listed Single-Phase PDUs : P = Remote Power Monitored; O = Monitored De-Rated Amps (A)/ Power (kw) Volts (V) in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. /Qty 9OB Thermal Circuit Breaker exit On-Off Switch -Local/ Remote Environmental Mounting (4) 9PG P 1.9 /1 5-P 10 5-R/ Magnetic Power/Aggregate - 2 Port Rack - 19" 17 x 1.72 x 6.5 9PB P 5 /8 L6-P C-13/24 + C-19/6 Magnetic Breaker Power/Circuit Breaker - 2 Port Vertical.25 9PB P 5 /8 L6-P C-13L/24 + Magnetic Breaker Power/Circuit Breaker - 2 Port Vertical 72 x 2 x PB P 5 /8 L6-P 42 C-13/36 + C-19/6 Magnetic Breaker Power/Circuit Breaker - 2 Port Vertical 70 x 2 x OB O 5 /8 L6-P 24 Magnetic Breaker Power/Circuit Breaker Port Vertical 72 x 2.25 x 2.25 (4) Standard PDU chassis color is black, custom color overlay (5) These PDUs have no Surge Supression BELDEN.1 ( )
3 Faster. 3-Phase PDUs 9LI UL Listed 3-Phase PDUs : B = Basic; L = Local Monitored ZPB IBBPS15 De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) /Qty(s) Circuit Breaker (Amp/Qty) - Local/Remote Mounting 9LI L 5.7 x 3 Ph. 1/8 WYE/8 L21-P C-13/24 + C-19/6 Amp (X,Y,Z)/ Vertical 9LJ L 8.6 x 3 Ph. 1/8 WYE/8 L21-P C-13/24 + C-19/6 /3D Amp (X,Y,Z)/ Vertical 9BJ B 8.6 x 3 Ph. 1/8 WYE/1 & 8 L21-P 33 C-13/24 + C-19/3 + 5-R/6 /3D Amp (X,Y,Z)/ Vertical 9LC L 11 x 3 Ph. 2/400 WYE/2 L22-P C-13/24 + C-19/6 Amp (X,Y,Z)/ Vertical 9LC L 11 x 3 Ph. 2/400 WYE/2 C-13/24 + C-19/6 Amp (X,Y,Z)/ Vertical 9LD L 16.6 x 3 Ph. 2/400 WYE/2 L22-P C-13/24 + C-19/6 /3D Amp (X,Y,Z)/ Vertical 9LD L 16.6 x 3 Ph. 2/400 WYE/2 C-13/24 + C-19/6 /3D Amp (X,Y,Z)/ Vertical 9BL B x 3 Ph. 8 Delta/8 12 C-19/ /6 Breaker/ Rack - 19" 9BL B x 3 Ph. 8 Delta/8 24 C-13/12 + C-19/12 /6 Breaker/ Vertical in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. exit (4) Ex: /3D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay 17 x 3.4 x x 2.3 x 3.45 (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by 1.44". 9PC OJ UL Listed 3-Phase PDUs : C = Remote Current Monitored; P = Power Monitored; O = Monitored De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) 9PC P 5.8 x 3 Ph. 1/8 WYE/8 L21-P 44 /Qty(s) C-13/36 + C-19/6 + 5-R/2 Circuit Breaker (Amp/Qty) (4) - Local/Remote Environ. Power/X, Y, Z - 2 Port 9CJ C 8.6 x 3 Ph. 1/8 WYE/8 L21-P C-13/24 + C-19/6 /3D Current/Current 9OJ O 8.6 x 3 Ph. 1/8 WYE/8 L21-P C-13L/24 + /3D 9OC O 11 x 3 Ph. 2/400 WYE/2 L22-P 24 9OD O 16.6 x 3 Ph. 2/400 WYE/2 24 /6 Power/X, Y, Z + Power/X, Y, Z + Power/X, Y, Z Port - 2 Port - 2 Port 9PL P x 3 Ph. 8 Delta/8 4P, 4W C-13/24 + C-19/6 /6D Power/X, Y, Z - 2 Port in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. exit (4) Ex: /3D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay 70 x 2 x x 2.25 x x 2.25 x x 2.3 x 3.45 (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by 1.44". (8) All these 3-Phase PDUs are vertically mounted BELDEN.1 ( ) 75
4 Single- and 3-Phase PDUs Front View 9SG Rear View 9SG UL Listed Single- and 3-Phase PDUs : S = Remotely Switched 9SJ SJ De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) / Circuit Breaker Qty(s) (Amp/Qty) (4) -Local/ Remote Mounting (5) 9SG S 1.9 1/1 5-P 8 5-R/8 Power/Agg Power Rack - 19" 9SG S 1.9 or or 8/1 or 8 C- 8 C-13L/8 Power/Agg + Rack - 19" 9SB S 5 8/8 L6-P 24 9SJ S 8.6 x 3 Ph. 1/8 WYE/8 L21-P 24 9SJ S 8.6 x 3 Ph. 1/8 WYE/8 L21-P 24 9SC S 11 x 3 Ph. 2/400 WYE/2 24 9SC S 11 x 3 Ph. 2/400 WYE/2 24 9SC S 11 x 3 Ph. 2/400 WYE/2 L22-P 24 9SC S 11 x 3 Ph. 2/400 WYE/2 L22-P 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 L22-P 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 L22-P 24 9SL S x 3 Ph. 8 Delta/8 24 9SL S x 3 Ph. 8 Delta/8 24 C-13L/ + C-19L/4 /2D Power/Agg, Circuit, Vertical /3D Power/Agg, Circuit Vertical /3D Power/Agg, Circuit, Vertical Power/Agg, Circuit Vertical Power/Agg, Circuit, Vertical Power/Agg, Circuit Vertical Power/Agg, Circuit, Vertical /6 Power/Agg, Circuit Vertical /6 Power/Agg, Circuit, Vertical /6 Power/Agg, Circuit Vertical /6 Power/Agg, Circuit, Vertical /6D Power/Agg, Circuit Vertical /6D Power/Agg, Circuit, Vertical 17 x 1.72 x x 1.72 x x 2.5 x x 2.5 x x 2.5 x x 4 x x 4 x 3.45 in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. 9SG Power Cord is sold separately. exit (4) Ex: /3D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay (6) These PDUs have no On/Off Switch or Surge Supression. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by 1.44". (8) All these Single- and 3-Phase PDUs have a Switched and a 2-port Environmental Monitor BELDEN.1 ( )
5 Faster. PDU Accessories Mounting, Cord Management and Cord Set Description Belden Part Number Tool-Less PDU Mounting Panel (for XM and XS Style Enclosures) Lacing-PDU Mounting Panel, 3.5"W, 42RU, Black Lacing-PDU Mounting Panel, 3.5"W, 45RU, Black Lacing-PDU Mounting Panel, 3.5"W, 48RU, Black Lacing-PDU Mounting Panel, 7"W, 42RU, Black Lacing-PDU Mounting Panel, 7"W, 45RU, Black Lacing-PDU Mounting Panel, 7"W, 48RU, Black Lacing-PDU Mounting Panel, 3.5"W, 42RU, White Lacing-PDU Mounting Panel, 3.5"W, 45RU, White Lacing-PDU Mounting Panel, 3.5"W, 48RU, White Lacing-PDU Mounting Panel, 7"W, 42RU, White Lacing-PDU Mounting Panel, 7"W, 45RU, White Lacing-PDU Mounting Panel, 7"W, 48RU, White Tool-Less PDU Mounting Panel (for XN Style Enclosures) XVMP0141 XVMP XVMP XVMP0241 XVMP XVMP XVMP0142 XVMP XVMP XVMP0242 XVMP XVMP " Lacing-PDU mounting panel 3.5" Lacing-PDU mounting panel PDU Mounting Bracket Double, Post Mounting 2 PDU Side-by-Side Facing Into Enclosure PDU Mounting Bracket Single, Rear Facing Pair PDU Mounting Bracket Rear Facing Pair Between Frames PDU Mounting Bracket Rear Facing Pair Between Frames with Extension Vertical Manager Panel, 42RU X 7.0"W, Black Vertical Manager Panel, 45RU X 7.0"W, Black Vertical Manager Panel, 48RU X 7.0"W, Black Vertical Manager Panel, 42RU X 7.0"W, CO White Vertical Manager Panel, 45RU X 7.0"W, CO White Vertical Manager Panel, 48RU X 7.0"W, CO White Tool-Less PDU Mounting Panel (for XSS Seismic Enclosures) Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Tool-Less PDU Mounting Panel (for XSN Seismic Enclosures) Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Power Cord Management Cable Management Ring Plastic (Qty = 5) 3" x 1.5" Reversible Cable Management Ring Kit (Qty = 5) 2.5"W x 3"D Slack Management Spool Kit (includes 2 spools) Quick Mount Base (Qty=10) with Fastener, for 1/4" Holes Velcro Cable Ties, 25 per Roll, 8" L x 0.5"W Velcro Cable Ties, 25 per Roll, 12" L x 0.5"W Cord Set* (C13/C19, C19/C - UL - cul Listed) C13 to C14 n-locking Cord Set - Y" Long Black C13 to C14 n-locking - 36" Long Black C13 to C14 n-locking - 48" Long Black C19 to C n-locking Cord Set - Y" Long Black C19 to C n-locking - 36" Long Black C19 to C n-locking - 48" Long Black C13 Locking to C14 - " Long Blue C13 Locking to C14 - " Long Orange C19 Locking to C - " Long Blue C19 Locking to C - " Long Orange C13 Locking to C14-39" Long Blue C13 Locking to C14-39" Long Orange C19 Locking to C - 39" Long Blue C19 Locking to C - 39" Long Orange XNPM01 XNPM02 XNPM03 XNPM04 XNVLP42901 XNVLP45901 XNVLP48901 XNVLP42902 XNVLP45902 XNVLP48902 XSN44VRPM101 XSN44VRPM1 XSN44VRPM102 XSN44VRPM2 XSN44VRPM101 XSN44VRPM1 XSN44VRPM102 XSN44VRPM2 XMR01 XMR03 XSK0 XCTM AX AX CSC13C14yyBK CSC13C1436BK CSC13C1448BK CSC19CyyBK CSC19C36BK CSC19C48BK CSLC13C14BL CSLC13C14OR CSLC19CBL CSLC19COR CSLC13C1439BL CSLC13C1439OR CSLC19C39BL CSLC19C39OR Mounting Brackets Cable Management Ring (Plastic) Locking Cord Set* Quick Mount Base *Built within the plug housing on the female end (C13/C19) of the cord, the patented integrated locking mechanism is protected against vibration and external elements that can easily dislodge other plug securing solutions, like external locking clips and guides. This self-contained locking mechanism engages with any standard IEC male connector (C14/C). The cord locking feature is only available at the device-end of the cord sets. A power strip with locking receptacles must be available to secure these cords to the PDU. yy = 12, 24, = cord length 12 to 96 inches; 12 inch increments BELDEN.1 ( ) 77
6 Power Distribution Unit Configuration Guide Please select the desired configuration and specifications and submit to Belden. Power Availability Quantity Required First Unit Required by Date Electrical Configuration Power Input Quantity** Input S Input 5-15P 15 L5-15P 15 5-P L5-P 6-P L6-P L14-P / L21-P x 3~ 1/8 WYE L5-P L6-P L14-P / L15-P x 3~ Delta L21-P x 3~ 1/8 WYE IEC C- Inlet ( Cord) /16* or 2 Pole/3 Wire /16* /2* 3 Pole/4 Wire 3~ 2 Pole/3 Wire /32* /2* 3 Pole/4 Wire 3~ 2 Pole/3 Wire 60/63* /2* 3 Pole/4 Wire 60 3~ Cord Length *Rating for CE Products **Quantity = # of Circuits Phone Target Price Comparable Competitive Unit Brand/Model# Power Input Quantity S 5-15R Duplex R Individual 15 L5-15R Duplex 15 5-R Duplex 5-R Individual L5-R 6-R Duplex L6-R L5-R L6-R IEC C-13 15/10* or IEC C-19 /16* or Other - Please Specify Physical Configuration Dimensional Limits Mounting Orientation Length Horizontal Width Vertical Height Hardwire Options Quantity** 6" Wire Tails with Removable Plate Flexible Conduit Terminal Block Additional Information Project Timeline Power Switch Surge Supression - with Cover Current Local Current Remote - Current (Amps) Only - Circuit Level - Scrolling Display - (Volts, Amps, Watts, Level Power Factor) Environmental Remote Switching Circuit Breakers Isolated Ground (required by NEC in some units) 3rd Party Testing - Compliance UR - UL UL Listed Recognized FCC Part 15 Class A CE ne Required Other - Please Specify BELDEN.1 ( )
7 Faster. and Configuration Chart NEMA s and s Straight-Blade P 5-15R 5-P 5-R 15 L5-15P L5-15R 1/8 x 3~ WYE L21-P L21-R L5-P L5-R 2/400 x 3~ WYE L22-P L22-R L5-P L5-R 1/8 x 3~ WYE L21-P L21-R L6-P L6-R 2/400 x 3~ WYE L22-P L22-R L6-P L6-R x 3~ Delta L15-P L15-R / L14-P L14-R / L14-P L14-R 50 x 3~ Delta /16* or Twist-Lock Straight-Blade Twist-Lock Straight-Blade Straight-Blade 6-P 6-R Twist-Lock Twist-Lock California Style IEC s and s Power Inlet Power 15/10* or /16* /2* 60/63* /2* 60 /32* /2 /16* 2/400* x 3~ WYE /32* 2/400* x 3~ WYE C-14 C-13 Pin & Sleeve Power Inlet Power C- C-19 Pin & Sleeve *Rating for CE Products What is 3-Phase WYE? 3-Phase Delta from 8V Source 3-Phase Delta from 1/8V Source X Phase X Phase Ground Z Phase Y Phase 8V (XY) Z Phase Ground L21-P 8V (XY) Y Phase 8V (ZX) 8V (ZX) Y Phase 1V (XN) 8V (YZ) A 3-Phase Delta is a 4-wire configuration consisting of 3-Phase conductors (X, Y and Z) and a Ground. Without the neutral present, only phase-to-phase wiring is possible. The potential between any 2-Phase conductors is typically 8V. 3 Phase WYE 3 Phase Delta X Phase Neutral L15-P A 3-Phase Delta 1/8V WYE is a 5-wire configuration consisting of 3-Phase conductors (X, Y and Z), Neutral and Ground. The potential between any 2-Phase conductors is 8V. The potential between any phase and neutral is 1V. This configuration can be wired to provide 1V, 8V or a combination of both voltages within one PDU BELDEN.1 ( ) What is 3-Phase Delta? 8V (YZ) Z Phase 1V (YN) 1V (ZN) Neutral Ground 79
Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal.
Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with ocal Monitoring and Intelligent Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based
More informationRack- and Panel-Mount Power Distribution Units (PDUs)
Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES Power on/off LED indicates whether power is available at the PDU External
More informationPower Distribution. For technical support call Online catalog available at leviton.com 461
INDEX FLX Series... 463 Switched Series... 464 Metered Series... 465 P1000 Series... 466 5500 & 5505 Series... 467 4500 Series... 468 For technical support call 800-824-3005 Online catalog available at
More informationPower Monitoring (RCX)
Power Monitoring (RCX) Geist s Power Monitoring PDUs provide a comprehensive remote view of your installation s power utilization. In addition to Amps, Volts, Real Power, Apparent Power, Power Factor and
More informationPolar PDUs POWER MANAGEMENT
Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data
More informationPOWER DISTRIBUTION UNITS (PDUs)
P R O D U C T D ATA S H E E T POWER DISTRIBUTION UNITS (s) for CPI Rack and Cabinet Systems K E Y F E AT U R E S Distribute power to multiple devices from a single power connection NEMA, California Style
More informationRack- and Panel-Mount Power Distribution Units (PDUs)
Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES INDUSTRY STANDARDS UL/cUL 60950 listed UL 1449 (Surge protector models
More informationPDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions
PDU A AUSTI POWER 3 PHASE WSI WI WS W MD BASIC Temperature & Humidity Sensors A pair of sensors can be connected to one single W series PDU meter. 3 PHASE Free Management Software Manager enhances the
More informationFrequently Asked Questions
Q. What is the power metering accuracy on CPI econnect PDUs? A. The power metering accuracy on CPI econnect PDUs is ±1% for each breaker. Meters are included in Monitored, Monitored, Switched and Switched
More informationRCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration RCOBN248-102PH6TL21-D Power Monitoring, Outlet Level 20A, 120/208V WYE, 5.7kW 66 in Vertical Description RCOBN248-102PH6TL21-D provides site managers
More informationInnovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s
Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,
More informationSwitched, Outlet Level Monitoring
Part Number Power Configuration Physical Configuration RCURN082-102D20TL5-OD Switched, Outlet Level Monitoring 20A, 120V, 1.9kW 19in / 483mm Horizontal Description The RCURN082-102D20TL5-OD provides hands-on
More informationThe -3Ph extension on a product indicates a 3 Phase power product.
Power Terms Glossary 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX). 24-Character Outlet
More informationMetered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:
More informationCS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)
CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationPower Distribution Units for Data Centers
WWW.SIEMON.COM Power Distribution Units for Data Centers PowerMax Power Distribution Units Siemon s PowerMax line of PDUs range from basic and metered for simple, reliable and cost-effective power distribution,
More informationInspired by Your Data Center. Intelligent W Series : 3 - Phase 208V
Inspired by Your Data Center Intelligent W Series : 3 - Phase 208V Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches, storage
More informationPDU - Overview / Non-Intelligent PDU s
PDU - Overview / Non-Intelligent PDU s InfraPower Rack Power Distribution Units InfraPower Rack PDU Range Switched (Outlet kwh PDU) Monitored (kwh PDU) Metered Basic WSi WS W MD Basic Outlet Measurement
More informationG GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration G1306 -- GRCOW246-103PH6PS6-D-IP44 Power Monitoring, Outlet Level 32A,, 7.3kW 72 in / 1829 mm Vertical Description G1306 -- GRCOW246-103PH6PS6-D-IP44
More informationPower Distribution Units for Data Centers
BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic
More information25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA
25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m
More informationCS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)
CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R
Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:
More informationCS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)
CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationHow do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.
If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Distribute and load balance 3-phase power? Monitor True RMS input current? Reboot
More informationTripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.
POWER DISTRIBUTION UNITS Tripp Lite rack power distribution for high-density IT environments. Introduction 2-3 Basic 4 Metered 5 Monitored 6 Switched 7 ATS 8 Hot-Swap 8 INTRODUCTION Tripp Lite Rack increase
More information5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA
Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:
More informationPanduit Basic Rack PDU with Local Meter
Panduit Basic Rack PDU with Local Meter User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationCAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. TM Introducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors of
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationipdu Pocket Guide NORTH AMERICA
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide NORTH AMERICA Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More informationPDI Modular Compact Remote Power Panel
Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications
More informationAPC APPLICATION NOTE #74
#74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.
More informationConfigurable power distribution
Configurable power distribution 60 150 kva The easy-to-deploy for data centers with custom requirements Configured to order, factoryassembled power distribution for IT equipment in any size data center
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationSwitched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
Switched XPDU 15A Model User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 10/02/14) Table of Contents Introduction...4 PDU Package...4 Function...4 Interface...4 Installation...5
More informationCisco CRS 16-Slot Chassis Power Systems
This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power
More informationUser Manual. Per Port Monitoring Models
User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port
More informationANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL
ANI-15115-08SWH PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com
More informationThe Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips
WHITE PAPER The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips By David Knapp Product Marketing Manager Chatsworth Products (CPI) Published: January 2019 US & Canada +1-800-834-4969
More informationModels. Specifications
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors
More informationInspired by Your Data Center. Intelligent W Series : 3 - Phase 400V
Inspired by Your Data Center Intelligent W Series : 3 - Phase 400V Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches, storage
More informationQuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview
HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching
More informationAcquiSuite Ally 48 Advanced Branch Circuit Monitor
AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition
More informationInspired by Your Data Center. 1-Phase Intelligent PDU IEC Outlet 208V / 230V
Inspired by Your Data Center 1-Phase Intelligent PDU IEC Outlet / 230 Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions,
More informationLiebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY
1.1 SUMMARY Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty,
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationSmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch
SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline
More informationInspired by Your Data Center. 1-Phase Intelligent PDU Outlets for 230V
Inspired by Your Data Center 1-Phase Intelligent PDU Outlets for 30V Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions,
More informationipdu Pocket Guide INTERNATIONAL
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide INTERNATIONAL Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More informationPDU Inspired by Your Data Center. W IEC PDU Series
PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement
More informationPanduit Basic Rack PDU
Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any
More informationInspired by Your Data Center. 1-Phase Intelligent PDU US NEMA Outlet 110V
Inspired by Your Data Center 1-Phase Intelligent PDU US Outlet 110V Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions,
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationQuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units
Overview Setting new standards for reliable power distribution and metering HPE Advanced Series G2 Metered PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a
More informationSmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules
SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules MODEL NUMBER: SV40KM2P2B Highlights Scalable capacity up to
More informationIBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide
IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and
More information30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent
More informationECO PDU Power Distribution Unit
ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationBasic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12
01-02 Basic PDU 03-04 Modules 05-06 SW Meter PDU 07-08 SW Meter Switch PDU 09-10 SW Three Phase PDU 11-12 How to install Safewell Basic PDU Series Model:SW-1U-8IEC13-K Product Description Size 19 * 1U
More informationSmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module
SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module MODEL NUMBER: SV20KS1P0B Highlights Scalable capacity up
More informationIntelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center
Intelligent W Series : 3 - Phase 208V 20A / 30A Inspired by Your Data Center Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches,
More information550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure
550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset
More informationInstruction Manual Basic Rack PDU VP7541 and VP9571A
Instruction Manual Basic Rack PDU VP7541 and VP9571A VertivCo.com/geist Table of Contents Specifications... 3 Overview... 3 Environmental... 3 Temperature... 3 Humidity... 3 Elevation... 3 Electrical...
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationSwitched econnect PDU
Protecting your technology investment. For use in data centers and equipment room racks and cabinets. Allows on/off control of power at individual outlets and provides continuous, automated monitoring
More informationC2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features
C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationSmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial
SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline
More informationpower.apitech.com Standard Solutions
power.apitech.com Standard Solutions Standard Commercial Solutions Section 3 Section 2 Section 1 Satellite Strips, Basic Power Strips AC and DC SMARTStart Power Strip Accessories Power Distribution Considerations
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More information20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management
More informationZonit μats TM Users Guide μats1-lv Version 1.2
Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational
More informationSetting new standards for reliable power distribution and metering
Overview Setting new standards for reliable power distribution and metering HPE G2 Switched PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a highly accurate
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationSwitched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional
More informationSolutions Guide for Cisco UCS B and C Series Servers
Solutions Guide for Cisco UCS B and C Series Servers The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and virtualization into a
More informationSeries 3000 User Manual and Product Features
Series 3000 User Manual and Product Features PN: OXA3501-890000 Revision 1.0 Technical Specifications 1.1 Model Number Description 1. Meter Series S3 Series 3000 meter Figure 1: Series 3000 model number
More informationServer Technology Inc.
Server Technology Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2011-Sept-22 Headquarters Server Technology, Inc. 1040 Sandhill
More informationQuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting
More informationInstruction Manual. Rack PDU XP Series. geistglobal.com
Instruction Manual Rack PDU XP Series geistglobal.com Table Of Contents 3 Table of Contents Specifications 4 Overview... 4 Environmental... 4 Tem perature... 4 Hum idity... 4 Elevation... 4 Electrical...
More informationIntelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability
TM Intelligent PDUs Best in Class Outlet Density Optimal Form Factors Superior Reliability SmartZone G5 Value Proposition Quality & Reliability High Temp High Power Density Hot-Swappable and Upgradable
More informationPOWER CABLES FOR MISSION CRITICAL FACILITIES
POWER CABLES FOR MISSION CRITICAL FACILITIES UL LISTED, MISSION-CRITICAL POWER CABLES MANUFACTURED AND TESTED IN A CONTROLLED ENVIRONMENT With 24-Hour Turn-Around, an unprecedented number of receptacles,
More informationEnerSure Installation Guide
EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded
More informationCisco Prisma II Platform
Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features
More informationTripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.
POWER DISTRIBUTION UNITS Tripp Lite rack power distribution for high-density IT environments. Introduction 2-3 Basic 4 Metered 5 Monitored 6 Switched 7 ATS 8 Hot-Swap 8 INTRODUCTION Tripp Lite Rack increase
More informationQuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions
Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions and guarantee a compatible fit for use with
More informationSmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System
SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower
More informationAll power outlet units include 10' power cords, mounting brackets, screws, unit packaging:
30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management
More informationSpecification Sheet: HT SERIES
Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured
More informationMonitored Pro econnect PDU
Protecting your technology investment. For use in data centers and equipment room racks and cabinets. Provides continuous, automated monitoring of each PDU and individual outlet, to provide measurement
More informationSEM3 - Embedded Micro Metering Module
SEM - Embedded Micro Metering Module Quick Reference Guide and Installation Instructions Scan QR Code for more information usa.siemens.com/sem Installation! DANGER Hazardous Voltage. Will cause death or
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationInnovative POWER Solutions
Innovative POWER Solutions ISO 9001 : 2008 REGISTERED QUALITY MANAGEMENT SYSTEM PANTROL, INC. INVITES YOU TO REVIEW A SAMPLING OF OUR STANDARD PRODUCTS LINE. FOR SPECIAL APPLICATIONS OR CONFIGURATIONS