EWPC 901/A rel. 6/96 ing

Similar documents
EWCH 485 Electronic Pulse Counter

4-step Chiller and Heat Pump Controller

EMPlus 600. Electronic digital indicator

ICPlus 902. Electronic controller with 1 intervention point

ID 974 DCC electronic controllers for forced air refrigeration units

EWPlus 961 EO Dispenser

e30v DIGITAL ELECTRONIC THERMOMETER OPERATING INSTRUCTIONS Index

Electronic controllers for small centralised air-conditioning units

EWTS LX programmable electronic timers

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

InBin-P Pressure switches from 5 Pa Pa

EZ-HT / EZ-MT / EZ-LT. Electronic controllers for refrigeration units

RТTH DUAL ROOM SWITCH

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

TLZ10 DIGITAL ELECTRONIC THERMOCONTROLLER. toll-free 1(866) (603) ADVANCED THERMOELECTRIC PO Box 1003, WRJ, VT 05001

Control Cube T Digital Temperature Controller Operating Manual

Room unit with PPS2 interface

Room Temperature Controllers

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Manual FC 3500 DC Fan Control

RXTP ROOM TEMPERATURE

Room Temperature Controller

Installation manual CF8-W-Disp-AL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Product and functional description

Room controller STRA-17

MAXIMA+ Series Rotary Level Indicator

7-day room temperature controller

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

Operating Instructions Differential Pressure Transducer PS27

Product and functional description

Electronic controllers for centralised air-conditioning units

MAXIMA + Series ROTARY LEVEL CONTROL

Digital Indicator Solutions

HygroFlex HF3 Transmitters. User Guide

Temperature controller Ducted systems

Tempco Instruction Manual

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

RXTH DUAL ROOM SENSOR / SWITCH

Room Temperature Controller

Rack Input Module Installation Instructions

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Custom Controller Installation Instructions

IGLOO IGLOO EASY INSTRUCTION MANUAL

Digital hygrometers. FUNction

IC 915 (LX) Alarm ON for active alarm; blinking when a silenced alarm is still present

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

HLS34 Modbus FCU/VAV Controllers installation instructions

The JODEL Piglet System Installer s Manual

MAXIMA + Series ROTARY LEVEL CONTROL

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Compact Coded Magnetic Safety Interlock Switch and Control Units

Operating Instructions VEGAMET 381

ID-Digifrost Line ID-DIGIFROST LINE BROCHURE

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Inductive Proximity Sensor

HygroFlex HF7 Humidity Temperature Transmitters. User Guide

IGLOO IGLOO EASY INSTRUCTION MANUAL

Controllers for static or ventilated refrigeration units up to 2HP. Innovative Solutions for Cold Rooms. Technology & Evolution

The Indicator with 3 Limit Contacts

Semi Flush-mount Room Temperature Controllers with LCD

DDC110-L1.. DDC110-L4 technolon Room Module

This document describes the features and functional specifications of the ECONO3 air conditioner controller.

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

TC-9102 Series Surface Mount Temperature Controllers

GCI-5K INSTALLATION AND OPERATOR S MANUAL

RM84 miniature relays

Dieter Wirth, Mess & Regeltechnik Neidlingen

STRA-17 Room controller. Installation and maintenance manual. Content

RM4LA32M liquid level control relay RM4-L V AC

Series SD-3PB Digital THERMOSTAT + TIMER

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Room unit with PPS2 interface

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Semi flush-mounted room temperature controllers with LCD

Test devices and Multifunction timer relay

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Infosystem Remote Touchscreen Installation Instructions

Operating Instructions for Digital Thermometers. Model: DTM

Switched Mode Power Supply Operating manual PAP800

HygroLog HL20 and HL21 Data Logger. User Guide

7-day room temperature controller

FLS M9.06. ph/orp MONITOR

XEV EX48 Superheat Controller

Avanti HP Series Centrifuges Preinstallation

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

ICPlus 915. Electronic controller with 2 intervention points

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Transcription:

EWPC 91A rel. 696 ing temperature controller with alarm output WHAT IT IS The EWPC 91A is a temperature controller specifically designed for refrigeration applications. The instrument includes a 1 Vdc output on the terminal block which controls the external alarm. HOW IT IS MADE Dimensions: front 74x3 mm (.913x1.6"), depth 67 mm (.637") Mounting: flush panel mount with mounting bracket Protection: the instrument frontpanel is waterproof IP65; an optional snap-on cover can be supplied to provide additional protection of the rear terminal block Connections: screw terminal block (.5 mm ; one wire each terminal only, in compliance with VDE norms) Display: 1.5 mm LED (.5") Push buttons: located on front panel Output: one (1) SPDT relay 8(3)A 5V AC Alarm output: 1 output 1 Vdc (4 ma max) Input: PTC probe Resolution: 1 C ( F) Accuracy: better than.5% of full scale Power supply (depending on model): 1 Vacdc or 4 Vacdc GENERAL DESCRIPTION The EWPC 91A is a temperature controller specifically designed for refrigeration applications; it is designed to operate as a cooling control, which means that the switching differential is positive: the cuts off at setpoint and is started at a temperature of set plus differential. In addition, the EWPC 91A offers several system protection features, all easy to understand and easy to program. With a suitable setting of parameter HC and a negative differential the controller can be used for heating applications. The relay is OFF at setpoint and is energized at a temperature of set minus differential. The instruments also includes a 1 Vdc output on the terminal block which controls the external alarm; this alarm can be silenced by pushing one of the buttons on the face plate. A number of parameters are displayed alphanumerically to set up the instrument for each specific application. The EWPC 91A is supplied in the popular 3x74 ELIWELL. FRONT KEYPAD SET: push to display the setpoint temperature. The setpoint can be changed within 5 seconds with the UP or DOWN button. The control will automatically switch back to normal operating mode within 5 seconds; the last entered setpoint will stay in memory. UP: used to increase the setpoint value, as well as the parameter when in programming. When held down for a few seconds, the change rate accelerates. DOWN: used to decrease the setpoint value, as well as the parameter when in programming. When held down for a few seconds, the change rate accelerates. Led ON : status light of the output. PARAMETER PROGRAMMING Programming is easily accessed by holding the SET button down for more than 4 seconds. The first parameter is displayed; other parameters are accessed with the UP and DOWN button. With the SET button, the actual setting of each parameter is displayed. To change a parameter setting, push the SET plus the UP or DOWN. The system will automatically return to its normal operating mode a few seconds after the programming procedure is completed or interrupted. DESCRIPTION OF PARAMETERS HC: HeatingCooling mode. Relay switch function. H = heating; C = cooling. d: switching differential (histeresis). Set with positive value for cooling applications; a negative value is used for heating mode. LS: Low Set. Setting of the lower user-access setpoint limit. HS: High Set. Setting of the upper user-access setpoint limit. CA: CAlibration. Temperature read-out offset to allow for possible error due to probe location. rp: relay Protection. Select relay status in case of probe defect. on = ON in case of probe defect; of = OFF in case of probe defect. PS: Protection System short cycle. Select type of protection desired (the actual time delay is set with the next parameter; only for cooling applications): = delay before start - in seconds; 1 = delay before start - in ; = delay after stop - in ; 3 = delay between starts - in. Pt: Protection time. Time delay setting for shortcycle protection (only for cooling applications); expressed in seconds ( to 31) if PS = or in ( to 31) if PS > (see parameter PS ). HA: High Alarm. This sets the deviation above the setpoint at which the acoustic alarm (internal buzzer) will active. LA: Low Alarm. This sets the deviation below the setpoint at which the acoustic alarm (internal buzzer) will active. Ad: Alarm differential. The allowable temperature swing between ON and OFF of the alarms. PA: Power-on Alarm. Time delay after start-up during which the alarm will not activate, in hours. INSTALLATION The instrument is designed for flush panel mounting. Insert the unit through a 9x71 mm panel cut-out and affix with the U- bracket supplied. The ambient temperature around the instrument should be kept between 5 and 65 C (3 149 F). Select a location which will not be subject to high humidity

DEFAULT SETTINGS - STANDARD MODELS Parameter HC d LS HS CA rp PS Pt HA LA Ad PA Description Heating Cooling differential Lower Set Higher Set CAlibration relay Protection Protection System Protection time High Alarm Low Alarm Alarm differential Power-on Alarm Range H C 15 15 55 99 55 99 15 15 on of 3 31 1 5 1 5 1 31 15 CONNECTIONS Default C -55 99 of 5 5 Unit number min sec hours Connections : screw terminal block (.5 mm ; one wire each terminal only, in compliance with VDE norms). Display : 1.5 mm LED (.5"). Push buttons : located on front panel. Data storage : non-volatile EEPROM memory. Operating temperature: 5 65 C; (3 149 F). Storage temperatu r e: 3 75 C; ( 167 F). Output : one (1) SPDT relay 8(3)A 5V AC. Alarm output : 1 output 1 Vdc (4 ma max). Input: PTC probe. Resolution : 1 C ( F). Accuracy : better than.5% of full scale. Power suppl y (dep. on model): 1 Vacdc ±15% or 4 Vacdc ±15%. 1 EWPC 91A 3 5 6 7 8 9 1 Eliwell via dell Artigianato, 65 Zona Industriale 31 Pieve d Alpago (BL) Italy Telephone +39 ()437 986111 Facsimile +39 ()437 98966 PTC probe + ALARM OUTPUT 1 Vdc4 ma max or condensation and allow some ventilation to provide cooling to the instrument. ELECTRICAL WIRING The instrument is equipped with an internal screw terminal block suitable for max.5 mm wiring (one wire each terminal only, in compliance with VDE norms). Make sure that the power supply corresponds with the rating shown on the instrument, i.e. 1 Vacdc ±15% or 4 Vacdc ±15%. The -wire PTC type probe does not require polarity and can easily be extended by using common -lead wire. It is strongly recommended to run the probe cable separate from line voltage wiring. Also, it is good practice to install the tip of the probe in upright position, to avoid moist from entering into the stainless steel sensor housing. The output relay contacts are voltage-free and are suitable for in-line switching of s up to.5 HP at Vac (or.5 HP to 11 Vac). For larger loads, an external contactor must be used. ERROR ANNOUNCIATION The instrument is provided with only one error message E1, both in case of shorted sensor and in case of sensor break, or sensor absence. The E1 error message also appears in the event of underrange of the system temperature ( 55). In the event of overrange of the system temperature (99), the 99 value will blink first, then the E1 error message will be displayed in case the probe will exceed the value of 15 (values above 99 will not be visualized on the display). It is recommended to doublecheck the sensor wiring before diagnosing a probe as defective. TECHNICAL DATA Housing : black ABS plastic, autoestinguish. Dimensions : front 74x3 mm (.913x1.6"), depth 67 mm (.637"). Mounting : flush panel mount with mounting bracket. Protection : the instrument frontpanel is waterproof IP65; an optional snap-on cover can be supplied to provide additional protection of the rear terminal block. EWPC 91A 696 ing

EWPC 91N temperature controller with single output WHAT IT IS The EWPC 91N is a one-intervention point electronic temperature controller specifically designed for refrigeration applications. HOW IT IS MADE Dimensions: front 74x3 mm (.913x1.6"), depth 67 mm (.637") Mounting: flush panel mount with mounting bracket Output: one (1) SPDT relay 8(3)A 5VA Input: GENERAL DESCRIPTION The EWPC 91N is a one-intervention point electronic temperature controller specifically designed for refrigeration applications;. The differential shall be set to positive values; the cuts off at setpoint and is started at a temperature of setpoint plus differential. In addition, the EWPC 91N offers several system protection features, that can be easily understood by analysing the programmable parameters, and ensure a suitable protection at close startups. With a negative differential the controller can be used for heating applications. The output stops when the Setpoint is reached and restarts when the temperature is equal to Setpoint minus the differential. The EWPC 91N can be used in several applications with a measurement range of 5 and 5 C, and is supplied in the 3x74 ELIWELL standard format. FRONT KEYPAD SET: push and release to display the setpoint temperature. The setpoint can be changed within 15 seconds with the UP or DOWN button. The new value is automatically stored after 15 seconds since the last operation. UP: used to increase the setpoint value, as well as the parameters when in programming. When held down for a few seconds, the change rate accelerates. DOWN: used to decrease the setpoint value, as well as the parameters when in programming mode. When held down for a few seconds, the change rate accelerates. Led OUT : led related to the relay. Led SET : blinks during setpoint displaychange and programming mode. PARAMETER PROGRAMMING Programming is accessed by holding the SET button down for more than 5 seconds. The first parameter label is displayed; other parameters are accessed with the UP and DOWN button. With the SET button, the current setting of each parameter is displayed. To change a parameter setting, push the UP or DOWN key. New values are stored on exiting programming mode (when no key is pressed for 15 seconds). DESCRIPTION OF PARAMETERS LS: Lower Set. Minimum allowed value for Setpoint (the upper limit is automatically updated to the Setpoint value). HS: Higher Set. Maximum allowed value for Setpoint (the lower limit is automatically updated to the Setpoint value). d: differential of intervention. Set to positive values for cooling applications; a negative value is used for heating mode. ct: type protection. It establishes the type of protection adopted to prevent close startups of the. = delay on activation, expressed in seconds; 1 = delay on activation, expressed in ; = there is a minimum off time before the following startup. The delay is expressed in ; 3 = there is a minimum delay between two successive startups of the. The delay is expressed in. cd: delay protection. Time related to the parameter ct. cp: Probe protection. Allows to select the use of the

DEFAULT SETTINGS - STANDARD MODELS Parameter LS HS d ct cd cp On OF od Lc dr CA ta Description Lower Set Higher Set differential type protection delay protection Probe protection time () On time () OFF output delay at power-on Lock keyboard display read-out CAlibration table of parameters relay in case of faulty probe. of = relay always disabled; on = relay always enabled; dc = relay controlled according to the timing set by parameters On and OF. On: time () On. Referred to parameter cp when set to dc ; defines the interval in during which the shall stay on. OF: time () OFF. Referred to parameter cp when set to dc ; defines the interval in during which the shall stay off. od: output delay (at power-on). Time delay applied to activation of the relays after start-up. Lc: keyboard Lock. Allows to disable keyboard operations. dr: display read-out. Permits to select either C or F display mode (no parameter is automatically converted from C to F). CA: CAlibration. Permits to change the value read by the probe in case of errors due to the sensor position. ta: table of parameters. Configuration index for factory set parameters; cannot be changed by the user. MECHANICAL MOUNT The instrument is designed for flush panel mounting. Drill a 71x9 mm hole and insert the unit fixing it with the U-bracket supplied. The ambient temperature around the instrument for correct operation should be kept between 5 and 55 C (3 131 F). Do not install the instrument in moist andor dirty places; it is suitable for operation in environments with an ordinary pollution level. Leave enough room for air circulation by the cooling holes of the instrument. ELECTRICAL WIRING Operations on electrical connections shall always be carried out after turning the machine off. The instrument is equipped with an internal screw terminal block suitable for Range 5 HS LS 5 1 1 3 99 of on dc 1 99 1 99 99 n y 1 1 Default 5 5 of 5 5 n C Unit number min sec max.5 mm wiring (one wire each terminal only, in compliance with VDE norms). Make sure that the power supply corresponds with the rating shown on the instrument, i.e. 3 Va ±1% or 115 Va ±1% or 1 Vac ±15%. The NTC type probe does not require polarity and can be easily extended by using common -lead wires (please note that long probes involve a worse instrument performance for electromagnetic compatibility: utmost care shall be put in cabling). It is strongly recommended to run the probe cable separate from line voltage wiring. The coordinated European standards impose that relay contact wires (and generally, all parts subject to dangerous voltage) shall be kept separate from very low voltage (probes, etc.) with insulation and distances suitable to ensure at least a doubled or reinforced insulation. EMC requirements however suggestimpose to put more care in such separation by using insulating separate raceways and proper cable fixing methods. The relay output is voltage-free and can control a direct s load up to.5 HP at 3 Va (or.5 HP at 115 Va) or 1 hp 5 Va. For heavier loads, an external contactor shall be used. ERROR SIGNALS The instrument is provided with error message E1, in case of shorted sensor and in case of sensor failure, or sensor absence. The E1 error message also appears in the event of underrangeoverrange of the system temperature. It is recommended to doublecheck the sensor wiring before replacing the probe. AUTHORISED USE For safety reasons, the control device should be installed and used according to the given instructions and, particularly, all parts subject to dangerous voltage shall not be accessible. under normal conditions. As to its application, the device should be properly protected against water and dust and, in addition, it should only be accessible by using a tool. The device may be applied on household appliances andor similar refrigerating equipment. Regarding the reference rules, this device may be classified as follows: - according to its manufacture: automatic, electronic, independent-mounting control device to be incorporated; - according to its automatic operating features: acting control device, 1 B type; - according to the class and structure of the software it uses: class A device. UNAUTHORISED USE Any use different from the authorised one is forbidden. We point out that relay contacts are of the functional type, and therefore subject to failure. Any protection device required by the rules concerning this product or dictated by common sense due to obvious safety reasons should be applied outside the instrument. LIABILITY AND RESIDUAL RISKS Eliwell cannot be held responsible for any damages due to: - installation andor use different from what the manufacturer intended and, in particular, differing from the safety rules provided for by law andor hereby stated; - use on equipment lacking a proper protection against electrical shock, water or dust under the performed installation conditions; - use on equipment allowing access to dangerous parts without employing any tools; - products tampering andor alteration; - installation or use on equipment which does not comply with the provisions of the law presently in force. TECHNICAL DATA Housing: resin (PC+ABS) with self-estinguishing grade V. Dimensions: front 74x3 mm, depth 67 mm. Mounting: flush panel mount with mounting bracket. Protection: the frontpanel is waterproof IP65; an optional snap-on cover can be supplied to provide additional protection of the rear terminal block. Connections: on screw terminal block (.5 mm ; one wire each terminal only for power connections). Display: on display with digit heights 1.5 mm. Commands: all located on front panel. Data storage: on non-volatile EEPROM memory. Operating temperature: 5 55 C. Storage temperature: 3 75 C. Main output: one relay output 8(3)A 5Va,5 hp 3Va or 1 hp 5Va. EWPC 91N 1 ing

Input: (SEMITEC 13AT- sensor 5 11 C). Measurement range: 5 5 C. Resolution: 1 C. Accuracy: better than.5% of full scale. Consumption: 1.5 VA Power supply: dep. on model. CONNECTIONS 1 HP EWPC 91N DISCLAIMER This manual and its contents remain the sole property of Invensys Controls Italy s.r.l., and shall not be reproduced or distributed without authorization. Although great care has been exercised in the preparation of this document, Invensys Controls Italy s.r.l., its employees or its vendors, cannot accept any liability whatsoever connected with its use. Invensys Controls Italy s.r.l. reserves the right to make any changes or improvements without prior notice. 1 3 CONNECTIONS,5 HP 1V 4 5 9 1 EWPC 91N 1 3 7 8 9 1 CONNECTIONS,5 HP V EWPC 91N 1 3 4 5 9 1 comp. Invensys Controls Italy s.r.l via dell'industria, 15 Zona Industriale Paludi 31 Pieve d'alpago (BL) ITALY Telephone +39 437 986111 Facsimile +39 437 98666 Email info@climate-eu.invensys.com Internet http:www.climate-eu.invensys.com 1 eng cod. 9IS1171 3 EWPC 91N 1 ing