IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

Similar documents
FAST, precise. qa software

Machine and Physics Data Guide

Version 3.7. User Manual

DAILY LINAC QA BEAM QA

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

PCRT 3D. Scalable Architecture System. User-Friendly. Traceable. Continuos Development

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

ADVANCING CANCER TREATMENT

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

ADVANCING CANCER TREATMENT

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

A SYSTEM OF DOSIMETRIC CALCULATIONS

ph fax Deming Way Middleton WI USA

Raising the Bar in IMRT QA

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

Dynalog data tool for IMRT plan verification

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Real-time monitoring of linac performance using RT plans and logfiles

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

Quick Reference Datasheet For All RIT113 Packages

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

Photon beam dose distributions in 2D

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Basic Radiation Oncology Physics

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI

Version 5.6. Quick Start Guide

Integrated proton-photon treatment planning

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

Radiation therapy plan checks in a paperless clinic

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles

The MSKCC Approach to IMRT. Outline

IMRT site-specific procedure: Prostate (CHHiP)

Modulation factors calculated with an EPID-derived MLC fluence model to streamline IMRT/VMAT second checks

PROVEN TECHNOLOGY IMPROVED

Table of Contents. About AQUA

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free beams

Using a research real-time control interface to go beyond dynamic MLC tracking

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

REF User Manual DOC # STANDARD IMAGING, INC Deming Way Middleton, WI

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

Computational modelling and analysis: IOP Medical Physics Group

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

3DVH FAQs. What is PDP questions

UNCOMPROMISING QUALITY

INTEGRATED DATA MIGRATION:

Feasibility of 3D Printed Patient specific Phantoms for IMRT QA and Other Dosimetric Special Procedures

LUP. Lund University Publications. Institutional Repository of Lund University

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Clinical implementation of photon beam flatness measurements to verify beam quality

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Image Guidance and Beam Level Imaging in Digital Linacs

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

Dose Calculation and Optimization Algorithms: A Clinical Perspective

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)

An Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields

Quality assurance of a helical tomotherapy machine

Comprehensive treatment planning for brachytherapy. Advanced planning made easy

Monaco Concepts and IMRT / VMAT Planning LTAMON0003 / 3.0

PrecisePLAN 2.00 Import

Initial Clinical Experience with 3D Surface Image Guidance

Basics of treatment planning II

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning. Rajat Kudchadker, Ph.D. Associate Professor

Photon Dose Algorithms and Physics Data Modeling in modern RTP

Points selected. Plan verified.

UNIVERSITY OF CALGARY. Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation. platform. Jared K.

TOMOHD. Product Specifications

Monitor Unit (MU) Calculation

TEPZZ Z754_7A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: A61N 5/10 ( )

SRI GURU RAMDAS INSTITUTE OF MEDICAL SCIENCES & RESEARCH MEHTA ROAD, VALLAH, SRI AMRITSAR

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Dose Calculations: Where and How to Calculate Dose. Allen Holder Trinity University.

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Plan Content (TDPC) Rev. 1.1 Trial Implementation

Commissioning, beam matching and small field dosimetry experience with Elekta Versa

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine

Geant4 in Brachytherapy

ViewRay System Commissioning

Transcription:

QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac time required IMSURE QA SOFTWARE

The process for verifying IMRT or rotational (RapidArc or VMAT) delivery is a very complex process. Dynamic MLC delivery creates hundreds of small fields that are difficult to verify by hand-calculations, a traditionally accepted practice in radiation therapy. IMSure QA Software uses advanced algorithms, including the patented 3-Source Model, to greatly reduce the time required to conduct IMRT and rotational delivery QA, without the need for film, phantoms or linac time. Developed at Stanford University, the 3-Source Model accurately calculates the head or collimator scatter (S c ) contribution to linear accelerator output. This model works for most field sizes and shapes, and for most points within the field. Incorporating these secondary check features into your QA processes will provide concise, confident verification of plans saved in the R&V system, while helping avoid potentially clinically significant errors. 1 MAIN PHOTON SOURCE 2 FLATTENING FILTER The 3-Source Model 3 PRIMARY COLLIMATOR In this illustration of a linac head, the red beam represents the primary photon source and the white lines show radiation scattered by the primary collimator and the flattening filter. Some scattered radiation may leak from the head and reach the patient through the jaws and multi-leaf collimator, contributing up to 12% of the dose the patient receives. IMSure QA is the only dose calculation software that uses the patented 3-Source Algorithm to calculate the contribution to dose accurately from all three of these sources as well as jaws & MLC.

Easy Monitor Unit Verification Non-IMRT plans for both photon and electron beams are easy to verify in IMSure QA. The information you need to verify your plan is shown on a single screen. Imported information can be automatically or manually filled in to create simple plans. Support for open beams, beams with blocks, stereotactic cones and wedged beams including the Varian Enhanced Dynamic Wedge, Elekta Omni Wedge and Siemens Virtual wedge is included. Fast IMRT And VMAT Dose Verifications The IMSure QA Software 3-Source Model delivers an accurate secondary check of your treatment plan quickly and easily. In only two steps, and in less than a minute, you can choose your patient treatment plan and analyze the results with IMSure QA. Advanced Features IMSure QA Software includes many advanced features allowing you to streamline your plan QA. In-vivo measurement support IMSure QA automatically calculates an expected reading for a diode placed at the surface in relation to the isocenter or any valid calculation point. A printable comprehensive setup report allows for easy setup and reporting of measured results Multiple calculation points Import unlimited points of interest from your treatment planning system or manually enter these for more complete plan evaluation Block editor An interactive block editor allows for the creation of standard or island blocks or editing of block shapes imported from your treatment planning system Heterogeneity correction Import CT images and structure set for automatic calculation of effective depths in IMSure QA..decimal Compensator Support Utilizing a full convolution algorithm, IMSure models the scatter, beam hardening effects and field-size dependencies to calculate a true compensator factor for even the most complex.decimal filters. Thorough Stereotactic QA Calculate and confirm cone-based or MLC-based stereotactic treatments, including conformal and dynamic arcs. Create specific energies in the physics module to accurately model small fields found in stereotactic plans. Cyberknife Plan Verification Module The Cyberknife module quickly and easily validates monitor units and dose for Raytrace and Monte Carlo plans created on the MultiPlan treatment planning system. Color coding immediately allows you to recognize individual projections that are outside tolerance. Comprehensive Verification of Your Entire Plan The patented Stanford University 3-Source Model considers the dose from the primary photon source, the primary collimator scatter, and the flattening filter scatter, resulting in extremely accurate dose calculations, including those in high-gradient/ low-dose regions common in IMRT. Does checking a single point constitute good QA? In classic IMRT QA protocol a phantom is placed on the couch with an ion chamber to check point dose, and film is placed between the phantom slabs to measure fluence for an overall plan evaluation. IMSure QA is the only software of its kind that can complete both parts of the classic IMRT protocol, point dose verification and a fluence check. With multiple calculation point support, IMSure allows you to place an unlimited number of virtual chambers anywhere in the field to sample point doses. IMSure will also import the fluence from your treatment planning system and directly compare that to an independently calculated fluence for comprehensive verification of your entire plan. Structures Importing the structure set along with your plan allows for better visualization of your plan data. Utilize contours to draw blocks for tissue sparing or to account for missing tissue (flash). Also import CT images for automatic effective depth calculation to account for patient heterogeneity. Structure Specific Analysis Utilize the Volumes control to analyze your plan based on anatomical structures of interest such as the PTV or a critical structure for in-depth analysis of your plan. Intuitive Computing View data for all beams on a single page Automatic SSD and effective depth calculations are performed when CT slices and structures are imported along with a plan. This allows the system to account for heterogeneities within the patient geometry. For VMAT plans, an optional Control Point Report provides segment by segment values for the SSD and effective depth of each calculation point. Check MU or specific-point dose quickly and easily with automatic hand calculations Imported treatment planning system fluence is directly compared to independently calculated fluence

Fast, Accurate Brachytherapy Plan Checks The Brachytherapy Module, available as an add-on component to IMSure, imports DICOM-RT plan files from treatment planning systems and utilizes the TG-43 formalism for dose calculations (Comparison to plan is in percentage difference). Accelerate Your Commissioning and Reports Visualize Sources in 3D View calculation reference points and sources, including catheters and dwell positions, in three dimensions with keyboard shortcuts for viewing orthogonal, sagittal, transverse and coronal planes Automatic Decay of Source Strength Choose whether to calculate the dose based on the reference source strength stored in the source library or the source strength at any date and time specified, including the time of implantation. OPERATING SYSTEM Windows 8.1 Windows 7 PROCESSOR MEMORY In-Depth Analysis of Each Dwell Position Choose the calculation point and dwell position of interest and each will be highlighted in the 3D view. The dose contribution to the chosen calculation point from the selected well position is shown along with the factors used in the calculation enabling easy analysis of every facet of the plan. IMSure QA Software (REF 91326) SPECIFICATIONS Intel or AMD, 600 MHz or greater 256 MB or greater HARD DRIVE SCREEN RESOLUTION CD ROM DRIVE 50 MB or greater 1024 x 768 or higher 2X speed or greater PRODUCT STANDARDS Designed to meet IEC 60601-1-4 Windows is a registered trademark of Microsoft Corporation. Specifications subject to change without notice. Physics is Easy with IMSure QA The Physics Interface for IMSure QA, like the rest of the software, is designed for ease-of-use. Linear accelerator data can be viewed in either tabular or graphical format in a single screen with an intuitive hierarchical design. IMSure QA relies on your linear accelerator parameters to simulate dose delivery. The data needed to set up IMSure come from the last time you commissioned your machine. For photons you need: Tissue Maximum Ratios (TMR), Off-axis Ratios (OAR), Output Factors (OF) and Head Scatter Factors (Sc). For electrons you need: Percent Depth Doses (PDD), Off-axis Ratios (OAR), Cone Output Factors (OF) and Cutout Factors (CF). Data can be entered for both standard 100 cm SSD and extended SSDs if desired. Simply set up the data in the IMSure QA format and import. A comprehensive guide and sample data sets are included to direct you in formatting your data for import. If you prefer to have your data set up for you, Standard Imaging will perform this service free for up to three linacs. Single Page User Interface Workflow, for every IMSure module, is designed around a single page view of an entire plan. Avoid redundant clicks while gaining confidence by quickly and easily navigating results from each field. Comprehensive Report Formats Print comprehensive reports of your calculation results for attachment to the patient record or export to a PDF or CSV file for use with electronic record keeping. Perform second checks of HDR, LDR, and permanent implant plans Single screen for inputs, outputs and field-to-field comparisons

www.standardimaging.com 800-261-4446. ph 608-831-0025. fax 608-831-2202 3120 Deming Way Middleton WI 53562-2532 USA 2017 Standard Imaging, Inc. 1265-26 (4.17)