MRS ELECTRONIC DATASHEET CAN 4 ANA DESCRIPTION TECHNICAL SPECIFICATION REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

Similar documents
MRS Electronic GmbH. Datasheet CAN I/O & CAN PLC CAN I/O & CAN PLC. CAN I/O & CAN PLC Site 1 of 5 Version 1.0

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Speaking Station LV30

Operating instructions. Speed monitor D / / 2014

Original operating instructions Safety relay with relay outputs G1501S / / 2016

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

TECHNICAL DATASHEET #TDAX023240

TECHNICAL DATASHEET #TDAX023300

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

Hardware Manual RM Display 1001

Installation instructions Inclination sensor EC2019 EC / / 2013

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating instructions. Standstill monitor A / / 2011

Electronic Control Unit RC

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

WI-I/O 9 Multi I/O Units

Draft sensor KMB series 30

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Hardware Manual RM CANview

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Hardware Manual RM Display 2501 S01..S04

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

User's Manual. english

Hardware Manual RM Display 2401

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Analog input module. 4 inputs, voltage and current

GFK-2415A March Type of sensor connection

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

MODEL 805 USER MANUAL

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Operating Manual FPGA-based High-Speed Micro-PLC

PHOENIX CONTACT - 07/2006

DI561 Digital Input Module

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

Temperature module. 4 inputs for resistance thermometers

VA-7700 Series. Electric Valve Actuators. Product Bulletin

P/N: AX Distribute your control functions directly onto the valve.

Assembly and Operating Instructions Door Control

Operating instructions RFID evaluation unit DTE / / 2016

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

Expansion Module HZS 541-1S

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Operating Instructions

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

TF501, TF521 Terminal Bases

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

TU531, TU532 Terminal Unit

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Position sensor PO1 series 20

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Manual Control Unit GFC 32

Version 1.9. Reference for Part Numbers: EQUBE-P EQUBE-N EQUBE-AI-P

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

IB080QM65VA3 Part Number

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

DX561 Digital Input/Output Module

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

igus motion Plastics dryve D3, DC-Motor Control System

HelmView Model HV750; HVS750. Installation Manual Section 78

BNI IOL K023 BNI IOL K023. User s Guide

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

Inductive sensor with analog output BI15-M30-LI-EXI

EH-RIO IP67 Profibus-DP I/O modules

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

TECHNICAL PRODUCT DATASHEET

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Model 8042 Submersible Accelerometer

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Manual Simatek Control Unit GFC 32

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Data sheet CPU 115 (115-6BL02)

HT-SG-100. Electronic Gas Engine Speed Governor. Smart Governing. Benefits

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

BODAS DCT Display Configuration Tool

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

QUINT-BUFFER/24DC/24DC/40

Digital I/O modules. 8 inputs/outputs, M8

Type Quickstart

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

VersaMax IP I/O Module

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Transcription:

DESRIPTION The Micro PL AN 4 ANA offers many possible applications with its 5 inputs and outputs. One analog input and four I/Os, the function of which can be individually defined. These inputs/outputs can be used as four analog outputs for current (0-24mA) and voltages (0-10V). Or you can configure them as four analog inputs. mounting direction view of plug TEHNIAL SPEIFIATION Housing onnector Weight Temperature range (according to ISO 16750-4) PA66GF30 plastic 9-pin bottom panel 28 g Environmental protection IP 53-40 to +85 urrent consumption 35 ma (at 12 V) 40 ma (at 24 V) Over-current Protection Total Inputs and outputs 4 Inputs Outputs Operating voltage Starting voltage Overvoltage protection Undervoltage cut-off urrent consumption + load current onfigurable as: Analog (0...11.4 V/0...33.7 V) urrent input (0...24 ma) Frequency input onfigurable as: onstant current source onstant voltage source 9-32 V 8 V 33 V 8 V Quiescent current 20 µa (bei 12 V und 24 V) Reverse polarity protection AN Interfaces Yes Highspeed 2.0 A/B according to ISO 11898-2 REGULATORY APPROVALS AND TESTING E1 approval EE R10 05 7522 Electrical tests Acc. to ISO 16750-2: Short ircuit supply I/O lines Reverse Polarity Interrupt Pin Break plug Jump Start Acc. to ISO 16750-4: Long-term overvoltage at 65 c Storage Test Tmax and Tmin Operations Test Tmax and Tmin Acc. to ISO 7637: ar pulses 1 to 4 to EE R10 SOFTWARE/PROGRAMMING Programming System MRS Developers Studio MRS Developers Studio with built-in functions library, similar programming with FUP. ustom software blocks can be integrated into -code. Program memory is sufficient for about 300 basic logic components. Page 1 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0

INPUT FEATURES - SUMMARY Pin 1, 3 Usable as analog or digital input Resolution 12 Bit 1% full scale Pin 5, 8 Usable as analog or digital input Resolution 12 Bit 1% full scale Voltage input 0...11.4 V (see "A") Input frequency f g =30 Hz 3 (33 Digits 100 mv, S.5) Voltage input 0 11.4 V (see "A") Input frequency f g =30 Hz 3 (33 Digits 100 mv, S.5) Voltage input 0...33.6 V (see "B") Input frequency f g =75 Hz 8,8 (12 Digits 100 mv, S.5) Voltage input 0...33.6 V (see "B") Input frequency f g =75 Hz 8,8 (12 Digits 100 mv, S.5) Digital input 7 V 5.5 V 20.5 V 15.6 V Digital input 7 V 5.5 V 20.5 V 15.6 V urrent input 0...24 ma (see "") 0,0175 (580 Digits 10 ma, S.5) urrent input 0...24 ma (see "") 0,0175 (580 Digits 10 ma, S.5) Frequency input (see "D") 2 Up to 5 khz max. 7 V 5.5 V 20.5 V 15.6 V 1 cutoff frequency (-3 db) 2 When programming via -code, both frequency inputs can be read in parallel. ONFIGURATION OF INPUTS Desired onfiguration Setting via Voltage input 0-11.4 V AI_NAME DO_I_NAME = 1, DO_30V_10V_NAME = 0, PWM_20MA_NAME = 0 Voltage input 0-33.6 V AI_NAME DO_I_NAME = 1, DO_30V_10V_NAME = 1, PWM_20MA_NAME = 0 Voltage input / current input Set: DO_I_NAME = 1, PWM_20MA_NAME (0-100% = 0-UB -3 V ) urrent output Set: DO_I_NAME = 0, PWM_20MA_NAME (0-100% = 0-22 ma) Frequency input ( and ) Reading of the input frequency via FREQ_NAME Page 2 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0

OUTPUT FEATURES - SUMMARY Pin 1,3,5,8 Digital, positive switching Switching voltage Switching current UB -3V 25 ma PIN ASSIGNMENT POWER SUPPLY AND INTERFAES Pin Pin description 2 Supply voltage 4 Battery/ignition contact 15 6 Ground Pin Pin description 7 AN - H 9 AN - L PIN ASSIGNMENT INPUTS AND OUTPUTS Pin Programm signal Pin description 1 DI_ AI_ DO_30V_10V_ DO_I_ PWM_20MA_ FREQ_ 3 DI_ AI_ DO_30V_10V_ DO_I_ PWM_20MA_ FREQ_ Digital input Analog input Range selection 11.4/33.6 V urrent sink urrent output Frequency input Digital input Analog input Range selection 11.4/33.6 V urrent Sink urrent output Frequency input Pin Programm signal Pin description 5 DI_A AI_A DO_30V_10V_A DO_I_A PWM_20MA_A 7 DI_ AI_ DO_30V_10V_ DO_I_ PWM_20MA_ Digitale input A Analog input A Range selection 11.4/33.6 V urrent Sink A urrent output A Digital input Analog input Range selection 11.4/33.6 V urrent Sink urrent output Bottom view Page 3 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0

PIN FEATURE MAP BLOK FUNTION DIAGRAM Page 4 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0

TEHNIAL DRAWING IN MM [INH] Bottom view Side view ONVERSION FATOR 4500 onversion Umrechnungsfaktor Factor Voltage Spannung (12 (12 V V Input) Eingang) 4500 onversion Umrechnungsfaktor Factor Voltage Spannung (30 (30 V Eingang) V Input) 4000 4000 return Rückgabewert value in in digits Digits return Rückgabewert value in in digits Digits 3500 3000 2500 2000 1500 1000 500 0 0 2000 4000 6000 8000 10000 12000 14000 Voltage Spannung in in mv 4000 3500 3000 2500 2000 1500 1000 500 0 0 5 10 15 20 25 urrent Strom in ma A A Linear (A) A Linear (A) Rückgabewert in Digits return value in digits Rückgabewert in Digits 3500 3000 2500 2000 1500 1000 500 0 0 5000 10000 15000 20000 25000 30000 35000 40000 Voltage Spannung in in mv mv Umrechnungsfaktor onversion Factor urrent Strom (12 V V Input) Eingang) onversion Umrechnungsfaktor Factor urrent Strom (30 (30 V Eingang) V Input) return value in digits 1400 1200 1000 800 600 400 200 0 0 5 10 15 20 25 urrent Strom in in mal ma A Linear (A) A Linear (A) Page 5 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0

ASSEMBLY OPTIONS AND ORDER INFORMATION Order number Pin numbering of the inputs AN Bus A Voltage B Voltage urrent D Frequency High-Speed Low-Speed 0 11.4 V 0 33.6 V 0-24 ma 0-5.5 khz 1.112.300.00 1,3,5,7 1,3,5,7 1,3,5,7 1,3 Page 6 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0

AESSORIES Description Order number Programming tool MRS Developers Studio 1.100.100.09 able set to programm AN 4 ANA 109446 Socket ST FL 9-pin 5x6.3 / 4x2.8 1.017.002.00 FASTON terminal 6.3 mm 1.5-2.5 mm 2 103064 FASTON terminal 6.3 mm 1.0 mm 2 102355 FASTON terminal 2.8 mm 0.5-1.0 mm 2 105292 Housing bracket 1.017.08.00 PAN-USB Interface 105358 abel FLRY 2 x 0.5 mm² white/green SL20 113085 MANUFATURER MRS Electronic GmbH & o. KG Klaus-Gutsch-Str. 7 78628 Rottweil Page 7 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0

GENERAL PROVISIONS Safe operation of series production equipment may not be guaranteed if samples or prototypes are used. Wiring examples provided by MRS Electronic GmbH & o. KG do not imply any endorsement, responsibility, or liability for the overall system performance. Incorrect wiring may result in unexpected or inconsistent signals at the outputs of the control device. Potential hazards during operation of equipment cannot be excluded when using incorrect software programs or parameter settings in the control device. To avoid a loss of manufacturer s warranty, installation, modification, or exchange of product firmware or software has to be performed by MRS Electronic GmbH & o. KG personnel or a qualified professional contractor. It is prohibited to open, modify or repair the control device. Modifications or repairs may result in hazardous malfunctions of the device. Maintenance and repair should be performed by MRS Electronic GmbH & o. KG personnel only. It is not permitted to apply voltage to device terminals other than the power terminals if the power supply of the control device is shut down or disconnected. If the power supply is shut down, it is important that power to the control device, power amplifiers, and external sensors is shut down simultaneously. In case of failure or malfunction of the control device, please ensure that this condition of the device does not result in a hazardous malfunction of the overall system. Such unintended system behavior may lead to personnel injuries or serious property damage. System design, installation, and commissioning of electrical systems must only be performed by a qualified professional who is familiar with the components used and the overall system. Unforeseeable hazards may be caused by the machinery during commissioning and maintenance of the control device. To prevent such events, please ensure that the machinery is always in a safe state. Faulty components or components with malfunction must not be used. If components fail or show signs of malfunction they have to be replaced or repaired immediately. ontrol devices that are used for software development and have been flashed more than 500 times with software updates must not be used in commercial machinery. WIRING AND ABLE ROUTING REOMMENDATIONS Electrical and power terminals of the control device have to be sourced by the same electric circuit. onnect the product only when wires/cables are de-energized. Mechanically secure the cable harness in close range of the installation location of the control device. Fix and adjust the cable harness for in-phase mechanical motion with the control device. It is not allowed to bridge PWM outputs together. Power levels of the sensor inputs may be amplified as a result of external wiring, because they are designed as power supply and not as power sink. Amplified power levels may lead to unforeseeable malfunction and in case of permanent operation to damage of the control device. The combined usable pins (I/Os) must not be externally switched against operating voltage. Special information for proportional magnets and solenoid switches or other switched inductive loads: The electronic circuitry must only be validated with the proportional valve connected. INSTALLATION REOMMENDATIONS Do not install the control device close to components which emit considerable amounts of heat. Ensure that water cannot get inside the control device by properly sealing all cables and wires. Always install the control device with the connector(s) pointing downwards allowing for condensation water to drain off (see figure on the first side). INTENDED USE If there are no restrictions for specific applications in this datasheet, the control device is designed for applications in mobile working machines. Use the control device only within the technical limits stated in this datasheet, especially with respect to voltages, currents, temperature, vibration, shock or any other specified environmental conditions. NOT INTENDED USE If the control unit is used in any other way than described in the paragraph INTENDED USE, it is not an intended use. Any use or application of the control device in explosive environments is prohibited. The manufacturer s warranty is void for any damages resulting from unintended use and/or arbitrary modifications which are not expressly indicated in this datasheet. Page 8 of 8 MRS Electronic GmbH & o. KG Subject to change without notice! Version 2.0