NEX-P6960M. P6960 to Mictor Adapter. General Description

Similar documents
NEX-DDR. 184-pin, 2.5V Double Data Rate (DDR) Bus Analysis Probe & Software

NEX-DDR266RWM. 184-pin, 2.5V Double Data Rate (DDR) Bus Analysis Probe & Software

NEX-DDRHSM. DDR 400MHz Bus Analysis Probe and Software

Mirrored DDRHS Support

NEX-SODIMMDDRII533. SODIMM DDRII 533MT/s Bus Analysis Probe and Software

DDR SODIMM Slot Interposer Flexible SODIMM Digital Validation

DDR bit SODIMM Slot Interposer w/ecc Flexible SODIMM Digital Validation

Serial RapidIO Gen2 Protocol Analyzer

Using the SODIMMDDRII667/800 NEXVu product a step by step overview with Signal Integrity Display

Tektronix Logic Analyzer Probes P5900 Series Datasheet

DPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual. February Rev 1.2

DDR3 Mini DIMM Slot Interposer

for Summit Analyzers Installation and Usage Manual

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

DDR3 DIMM Slot Interposer

DDR Support for Tektronix TLA Logic Analyzers

BOARD-TO-BOARD HEADERS & RECEPTACLES

AVA AT-to-SCSI Host Adapter. Installation Guide

Raven Adapter Harness

DPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. March Rev 1.0

P375 Data Sheet & Applications Notes. PG3A Pattern Generator P375 Variable Universal probe April Rev 1.0

InSight Single Implement

DDR Detective Probing

Installation Manual AIS 240B-35

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca Fax Est

DesignCon 2005 Track 5: Chip and Board Interconnect Design (5-TA2)

DYNAMIC ENGINEERING. 150 DuBois St. #3, Santa Cruz Ca Fax Est

DESIGN SPECIFICATION # R1 Model AHRS-500 P/N ARINC 407 TO ARINC 429 ADAPTOR CTRL # /17/96

Maxim Integrated Products 1

BOARD-TO-BOARD HEADERS & RECEPTACLES

Ethernet Adapter Installation Instructions

Installation Manual AIS 200B-35

Magnetic probe holders are fully adjustable for more DUT heights and probe styles

MODELS PD230 AND PD1230 Installation Instructions

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor.

Upgrade Kit for the 4300 Remote BAC About This Document Using This Document Note Caution Inspecting Shipment

CLINCHER FLEX CONNECTORS OVERVIEW TARGET MARKETS / APPLICATIONS FEATURES & BENEFITS

MS-5000: MiniStar Reader

Probing Solutions for Logic Analyzers

Series 062 Bus Bar Connectors

Power Supply, 17-inch

Ioline 300/350HF System

DirectCommand Installation 5 Channel Spreader Control Module Technology

Installation Manual AIS AIS 200A-35

Powered RS Port PCI Card

MX Educational Target User Manual

Scope adapters and probes. Surface mount QFP Logic Analyzer adapters

TVA2.1 2-Channel Digital Amplifier Installation Manual

SNAP-IT-1U Installation Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

PLC Racks IC697CHS782/783

Ideal for a wide range of applications such as wafer test or PCB test for mm-wave, Microwave, RF or Automotive applications

Instructions. P6434 Mass Termination Probe

Powered RS Port PCIe Card

TeamBoard Quick Start #1

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Termination End. Figure 1

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

3M Indoor Protected Building Entrance Terminal 4588V-QCS Series

IQEXTENDER IQ Module. Board Manual. March Order Number:

Indoor Protected Entrance Terminal 4588 Series

Tone Generator and Probe

Allows full two way communication from any USB or RS232 port to an SPI device.

Raspberry Pi board. EB080

Tim Hortons EI30 Ethernet Interface Circuit Board

Installation Guide AMM-1525M/1510M/525M. SCSI Audio Host Adapters and Sound Cards

RIBBON CABLE CONNECTORS

What is a Hotwire Shelf Concentration Module?

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

Mini-Dock Installation Guide

RSA5100B Series Real-Time Signal Analyzers RSA5BUP Option 300 High Performance Real Time Upgrade Instructions

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

Installation Instructions

CompuScope 3200 product introduction

University of Alexandria Faculty of Engineering Division of Communications & Electronics

Installation Manual. This 5.25 enclosure is designed to provide a solution to connect. existing storage devices such as 3.5 IDE hard drive, MO drives,

Open Processor with Carrier CCN DataLink Driver

CH 2 CH 1 BALANCED INPUTS

Code Dynamics, Inc. Port Splitter

Cab Box Kit Dome Plug Cab Box Cab Box Lid

AMP-HDI* Connectors. Solder Tail. Keying Hole Keying Hole. Vertical Pin Assembly. Figure 1

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

QuickNetwork QND300 Distribution Panel

MS-7000: SuperStar Reader

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

COPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION

QuickNetwork QND200 Distribution Panel

Oct 16 Rev D

Powered RS Port PCIe Card

How to Design Custom Enclosures for Motherboard-Based Systems

AI port High Speed Asynchronous Line Card Installation Guide

MS-3000 MicroStar Reader

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

Description. Overview. Features S90-MTM-DEV-2. MTM Development Board 2.0 Datasheet

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Direct Injection Module

BUTT SET MODEL TT-200

PCIE FIVE SLOT EXPANSION SYSTEM USER S MANUAL

Basketball Shot Clock Set LX2180 Manual

Transcription:

P6960 to Mictor Adapter NEX-P6960M Designed for the customer that needs to convert from a P6960 foot print connection on their System Under Test to a Mictor-type Logic Analyzer connection General Description The NEX-P6960M is an interface adapter used when the System Under Test contains the P6960 style D- Max connections and the customer needs to use Tektronix Mictor probes. This adapter interfaces the two probe types. The NEX-P6960M adapters are not static sensitive Adapter signal lengths are matched to 0.25 Cautions To ensure acceptable performance the customer must take into consideration the extra stub length added by this adapter in their simulations Existing Address and Data Mictor channel assignments do not map directly to the Mictor TLA inputs. A microprocessor or bus support package, designed for P6960 connectors, may need to be recompiled to use these adapters. Refer to Table 1 for a TLA input cross-reference list between the P6960 and Mictor connectors on this adaptor.

Connection to the System Under Test The P6960 end of the adapter (the end that connects to the system under test) is not keyed for correct alignment. For correct connection to the system under test the P6960 end of the NEXUS adapter must be connected to the system under test by matching the black screw to the black tie down, and the silver screw to the silver tie down. Channel mapping on the NEXUS adapter between the P6960 and Mictor connectors are contained in Table 1. This table is only applicable to 102- and 136-channel Logic Analyzer Modules. Table 2 shows the pinout for 68-channel modules. Mictor AMP/Tyco Pin # A D C E P6960 Pin # A/D High A/D Low C 5 CLK:0 Q0 CLK:3 Q3 A7 CLK:0 CLK:1 CLK:3 Q3 7 A3:7 D3:7 C3:7 E3:7 A14 A3:7 A1:7 C3:7 E3:7 9 A3:6 D3:6 C3:6 E3:6 A13 A3:6 A1:6 C3:6 E3:6 11 A3:5 D3:5 C3:5 E3:5 B12 A3:5 A1:5 C3:5 E3:5 13 A3:4 D3:4 C3:4 E3:4 B11 A3:4 A1:4 C3:4 E3:4 15 A3:3 D3:3 C3:3 E3:3 A11 A3:3 A1:3 C3:3 E3:3 17 A3:2 D3:2 C3:2 E3:2 A10 A3:2 A1:2 C3:2 E3:2 19 A3:1 D3:1 C3:1 E3:1 B9 A3:1 A1:1 C3:1 E3:1 21 A3:0 D3:0 C3:0 E3:0 B8 A3:0 A1:0 C3:0 E3:0 23 A2:7 D2:7 C2:7 E2:7 B6 A2:7 A0:7 C2:7 E2:7 25 A2:6 D2:6 C2:6 E2:6 B5 A2:6 A0:6 C2:6 E2:6 27 A2:5 D2:5 C2:5 E2:5 A5 A2:5 A0:5 C2:5 E2:5 29 A2:4 D2:4 C2:4 E2:4 A4 A2:4 A0:4 C2:4 E2:4 31 A2:3 D2:3 C2:3 E2:3 B3 A2:3 A0:3 C2:3 E2:3 33 A2:2 D2:2 C2:2 E2:2 B2 A2:2 A0:2 C2:2 E2:2 35 A2:1 D2:1 C2:1 E2:1 A2 A2:1 A0:1 C2:1 E2:1 37 A2:0 D2:0 C2:0 E2:0 A1 A2:0 A0:0 C2:0 E2:0 6 CLK:1 CLK:2 Q1 Q2 B21 Q0 CLK:2 Q1 Q2 8 A1:7 D1:7 C1:7 E1:7 B14 D3:7 D1:7 C1:7 E1:7 10 A1:6 D1:6 C1:6 E1:6 B15 D3:6 D1:6 C1:6 E1:6 12 A1:5 D1:5 C1:5 E1:5 A16 D3:5 D1:5 C1:5 E1:5 14 A1:4 D1:4 C1:4 E1:4 A17 D3:4 D1:4 C1:4 E1:4 16 A1:3 D1:3 C1:3 E1:3 B17 D3:3 D1:3 C1:3 E1:3 18 A1:2 D1:2 C1:2 E1:2 B18 D3:2 D1:2 C1:2 E1:2 20 A1:1 D1:1 C1:1 E1:1 A19 D3:1 D1:1 C1:1 E1:1 22 A1:0 D1:0 C1:0 E1:0 A20 D3:0 D1:0 C1:0 E1:0 24 A0:7 D0:7 C0:7 E0:7 A22 D2:7 D0:7 C0:7 E0:7 26 A0:6 D0:6 C0:6 E0:6 A23 D2:6 D0:6 C0:6 E0:6 28 A0:5 D0:5 C0:5 E0:5 B23 D2:5 D0:5 C0:5 E0:5 30 A0:4 D0:4 C0:4 E0:4 B24 D2:4 D0:4 C0:4 E0:4 32 A0:3 D0:3 C0:3 E0:3 A25 D2:3 D0:3 C0:3 E0:3 34 A0:2 D0:2 C0:2 E0:2 A26 D2:2 D0:2 C0:2 E0:2 36 A0:1 D0:1 C0:1 E0:1 B26 D2:1 D0:1 C0:1 E0:1 38 A0:0 D0:0 C0:0 E0:0 B27 D2:0 D0:0 C0:0 E0:0 Table 1: TLA Input Cross-Reference List 102-/136-channel cards E

Mictor AMP/Tyco Pin # A C P6960 Pin # A/D High C 5 CLK:0 CLK:3 A7 CLK:1 CLK:3 7 A3:7 C3:7 A14 A1:7 C3:7 9 A3:6 C3:6 A13 A1:6 C3:6 11 A3:5 C3:5 B12 A1:5 C3:5 13 A3:4 C3:4 B11 A1:4 C3:4 15 A3:3 C3:3 A11 A1:3 C3:3 17 A3:2 C3:2 A10 A1:2 C3:2 19 A3:1 C3:1 B9 A1:1 C3:1 21 A3:0 C3:0 B8 A1:0 C3:0 23 A2:7 C2:7 B6 A0:7 C2:7 25 A2:6 C2:6 B5 A0:6 C2:6 27 A2:5 C2:5 A5 A0:5 C2:5 29 A2:4 C2:4 A4 A0:4 C2:4 31 A2:3 C2:3 B3 A0:3 C2:3 33 A2:2 C2:2 B2 A0:2 C2:2 35 A2:1 C2:1 A2 A0:1 C2:1 37 A2:0 C2:0 A1 A0:0 C2:0 6 CLK:1 Q1 B21 CLK:2 Q1 8 A1:7 C1:7 B14 D1:7 C1:7 10 A1:6 C1:6 B15 D1:6 C1:6 12 A1:5 C1:5 A16 D1:5 C1:5 14 A1:4 C1:4 A17 D1:4 C1:4 16 A1:3 C1:3 B17 D1:3 C1:3 18 A1:2 C1:2 B18 D1:2 C1:2 20 A1:1 C1:1 A19 D1:1 C1:1 22 A1:0 C1:0 A20 D1:0 C1:0 24 A0:7 C0:7 A22 D0:7 C0:7 26 A0:6 C0:6 A23 D0:6 C0:6 28 A0:5 C0:5 B23 D0:5 C0:5 30 A0:4 C0:4 B24 D0:4 C0:4 32 A0:3 C0:3 A25 D0:3 C0:3 34 A0:2 C0:2 A26 D0:2 C0:2 36 A0:1 C0:1 B26 D0:1 C0:1 38 A0:0 C0:0 B27 D0:0 C0:0 Table 2: TLA Input Cross-Reference List 68-channel cards

Silkscreen Front for NEX-P6960M Amp/Tyco P/N 767044-1 accepts P6434 probe

Silkscreen Back for NEX-P6960M

Mechanical Specification for NEX-P6960M Keep Out Volume: Bottom keep out is the same as the P6960 --- Height from the circuit board to the top of the retention screws is 1.512, width is 0.25. There is approximately two inches of coax between the P6960 probe tip and the Mictor connector board. Product above is a Tektronix P6960. Drawing taken from Tektronix data sheet.

Mechanical of Mictor interface board Equivalent Circuit

Ordering / Contact Information Please see the website or contact us for complete solutions. Part Number NEX-P6960M Interface between P6960 connections on SUT and Logic Analyzer Mictor probes Postal: Nexus Technology, Inc. 78 Northeastern Blvd. #2 Nashua, NH 03062 Telephone: 877-595-8116 Fax: 877-595-8118 Email: support@nexustechnology.com quotes@nexustechnology.com techsupport@nexustechnology.com Website: www.nexustechnology.com Placing an Order Credit Card orders can be placed directly at 877-595-8116. Purchase orders can be faxed to 877-595-8118. Nexus Technology, Inc. reserves the right to make changes in design or specification at any time without notice. Nexus Technology, Inc. does not assume responsibility for use of any circuitry described. All trademarks are the property of their respective owners.