Project GAMMA: Adaptive Methods for Medical Applications

Similar documents
arxiv: v1 [physics.ins-det] 3 Feb 2016 V. Solovov, A. Morozov, V.Chepel, V. Domingos, R. Martins

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

Development of a high resolution animal PET with continuous crystals and SiPMs

Fast Timing and TOF in PET Medical Imaging

Constructing System Matrices for SPECT Simulations and Reconstructions

Extremely Fast Detector for 511 kev Gamma

Interpolating Silicon Photomultipliers

8/2/2017. Disclosure. Philips Healthcare (Cleveland, OH) provided the precommercial

in PET Medical Imaging

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Introduction to Positron Emission Tomography

A region segmentation based algorithm for building crystal position lookup table in scintillation detector

Deliverable D10.2. WP10 JRA04 INDESYS Innovative solutions for nuclear physics detectors

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

Characterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3T MRI. Floris Jansen, GE Healthcare July, 2015

Nuclear Instruments and Methods in Physics Research A

Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system

INTERNATIONAL STANDARD

Medical Imaging BMEN Spring 2016

Tomographic Algorithm for Industrial Plasmas

Development of LYSO Detector Modules for an EDM Polarimeter at COSY. for the JEDI Collaboration

Full 3D scan of an AGATA crystal using the PSCS technique

SiPMs for Čerenkov imaging

Introduction to Computer Vision

Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

A dedicated tool for PET scanner simulations using FLUKA

A Further Study on Large Size LSO and LYSO Crystal Samples

Gamma spectroscopic measurements using the PID350 pixelated CdTe radiation detector

Biomedical Imaging. Computed Tomography. Patrícia Figueiredo IST

CHAPTER 11 NUCLEAR MEDICINE IMAGING DEVICES

AX-PET : A novel PET concept with G-APD readout

Application of MCNP Code in Shielding Design for Radioactive Sources

Identification of Shielding Material Configurations Using NMIS Imaging

MACHINE VISION AS A METHOD FOR CHARACTERIZING SOLAR TRACKER PERFORMANCE

218 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 44, NO. 2, APRIL 1997

James R Halama, PhD Loyola University Medical Center

Dynamic Reconstruction for Coded Aperture Imaging Draft Unpublished work please do not cite or distribute.

Performance Evaluation of radionuclide imaging systems

Kondo GNANVO Florida Institute of Technology, Melbourne FL

Improved Detector Response Characterization Method in ISOCS and LabSOCS

Status of the TORCH time-of-flight detector

Evaluation of a Combined Array-Planar Crystal for Gamma-ray Scintillation Imagers

Update on PRad GEMs, Readout Electronics & DAQ

SPECT: Physics Principles and Equipment Design

Introduction to Emission Tomography

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Review of PET Physics. Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA

CT vs. VolumeScope: image quality and dose comparison

Alignment of the ATLAS Inner Detector

Automated Laser-Beam Steering. Margot Epstein

An educational tool for demonstrating the TOF-PET technique

SUPPLEMENTARY INFORMATION

Fits you like no other

Live-cell 3D super-resolution imaging in thick biological samples

Fits you like no other

OMEGA Experimental Operations 2011 OLUG Status Report

CSPAD FAQ And starting point for discussion. Philip Hart, LCLS Users Workshop, Detector session, 2 Oct 2013

Image Reconstruction Methods for Dedicated Nuclear Medicine Detectors for Prostate Imaging

Search for hidden high-z materials inside containers with the Muon Portal Project

CT Systems and their standards

Homography estimation

Structured Light II. Thanks to Ronen Gvili, Szymon Rusinkiewicz and Maks Ovsjanikov

Supplementary Figure 1

ACOMPTON-SCATTERING gamma camera records two

Assessment of OSEM & FBP Reconstruction Techniques in Single Photon Emission Computed Tomography Using SPECT Phantom as Applied on Bone Scintigraphy

The HEP.TrkX Project: Deep Learning for Particle Tracking

Klaus Dehmelt EIC Detector R&D Weekly Meeting November 28, 2011 GEM SIMULATION FRAMEWORK

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam

EPSRC Centre for Doctoral Training in Industrially Focused Mathematical Modelling

Single-Volume Scatter Camera: simulation results

GPU implementation for rapid iterative image reconstruction algorithm

FUZZY CLUSTERING ALGORITHM FOR GAMMA RAY TRACKING IN SEGMENTED DETECTORS

Optimisation of Toshiba Aquilion ONE Volume Imaging

Mediso AnyScan S Single-Head and Dual-Head SPECT

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

Emission Computed Tomography Notes

Mediso AnyScan. Single-Head and Dual-Head SPECT

Reconstruction from Projections

Image Processing Fundamentals. Nicolas Vazquez Principal Software Engineer National Instruments

SoLID GEM Detectors in US

Evaluation of Centrally Located Sources in. Coincidence Timing Calibration for Time-of-Flight PET

STIR. Software for Tomographic Image Reconstruction. Kris Thielemans

POME A mobile camera system for accurate indoor pose

Addition of Noise by Scatter Correction Methods in PVI

Data integration and scaling

Determination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging

MEDICAL IMAGING 2nd Part Computed Tomography

Work in Tbilisi. David Mchedlishvili (SMART EDM_lab of TSU) GGSWBS , Tbilisi. Shota Rustaveli National Science Foundation

Reflectance of the Teflon R for ultraviolet light

Shape and deformation measurements by high-resolution fringe projection methods February 2018

Independent Resolution Test of

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

Standard Operating Procedure for the Horiba FluroMax-4

Continuation Format Page

by Photographic Method

Simulation of Internal Backscatter Effects on MTF and SNR of Pixelated Photon-counting Detectors

SUBMITTED 15/08/2018 TO: IEEE TRPMS - SPEICIAL ISSUE PSMR2018-7TH CONFERENCE ON PET/MR AND SPECT/MR 1

Real-Time, High-Accuracy 3D Tracking of Small Animals for Motion-Corrected SPECT Imaging

Transcription:

Project GAMMA: Adaptive Methods for Medical Applications V. Solovov, A. Morozov, V. Chepel, V. Domingos, R.Martins, L. Pereira, F. Neves, A. Lindote, F. Fraga, I.Lopes, F. Alves LIP-Coimbra and Coimbra University, Portugal

Scintillation Camera Hal Anger, 1957 Applications: Nuclear medicine Astrophysics Neutron detection 1

Centre of Gravity Advantages: Robust and easy to implement Very fast Works out of the box for virtually any configuration Problems: Image distortion No way to filter out bad events Centroid Workarounds: Stretched centroid (periphery) Correction table (local nonlinearity) + Many patented techniques from gamma camera manufacturers The net result can be good image quality for the price of frequent re-calibrations OK for a commercial device but might be unacceptable for a research instrument Stretched Centroid 2

Event reconstruction (2D) Event Detection event (x, y, e) Detector + electronics + DAQ S2 Detector model x, y, e event (x, y, e) ai=ci e ηi (x,y) Hit pattern {Ai} Expected pattern {ai} To reconstruct an event from a hit pattern, find x, y and e for which the expected pattern {ai} is in the best agreement with hit pattern {Ai}. How to find this best match? Maximum likelihood (Gray & Macovsky, 1976) Least squares Neural network What if no agreement was found? Either the event is bad Or the model is wrong All these methods require ηi (x,y) Light Response Function 3

Light Response Functions Light Response Function (LRF) ηi(x,y) characterizes response of a PMT as a function of a light source position (x,y). In many cases it has axial symmetry and can be reduced to ηi(r) where r is the distance from the PMT axis How to find ηi(r)? Measure (time consuming in 2D, extremely difficult in 3D) Simulate (requires detailed knowledge of detector geometry, material optical properties and PMT properties) Use Iterative Reconstruction with experimental data (a technique first developed in LIP for ZEPLIN-III experiment) 1. Chose a 1st approximation for LRFs (e.g. from simulation) 2. Reconstruct the event positions using the LRFs 3. Use the reconstructed event positions to update the LRFs 4. GOTO 2 Under right conditions, the LRFs converge to the true PMT response. 4

Iterative reconstruction: (simulated data) Initial data Flood field: events uniformly cover the outlined area (black rectangle) Energy spread: 20% FWHM Blue: initial data Red: actual LRF Initial gains: random, up to 30% off the actual values LS reconstruction of the flood field data 5

Iterative reconstruction: (simulated data) After one iteration Blue: 1st iteration Red: actual LRF LS reconstruction of the flood field data 6

Iterative reconstruction: (simulated data) After 10 iterations Blue: 10th iteration Red: actual LRF Reconstructed gains are within 5% from the actual values! LS reconstruction of the flood field data 7

Real life examples 5 mm LUX GSPC neutron detector ZEPLIN-III

Adaptive methods It was shown that PMT response in Anger camera can be correctly reconstructed from flood irradiation data under favorable conditions: High light output (secondary scintillation) Low fraction of indirect light Reconstructed PMT response includes relative PMT gains, thus making possible auto-calibration for Anger camera LRFs can change over time (PMT gain drift, photocathode and crystal degradation, etc.) Iterative reconstruction can follow these changes, hence: Adaptive Methods 9

Medical application Can we apply LRF based event reconstruction techniques + adaptive LRF reconstruction methods to medical imaging? Advantages: Better image on periphery Improved useful field of view Important for small devices, e.g. prostate imaging cameras Automatic tracking of PMT gain fluctuations Less frequent and simpler calibration (reduced downtime) Save money on maintenance Improve image quality Challenges: Lower signal to noise ratio Multiple scattering 3D reconstruction (in some cases) 10

ANTS - II Integrated software package for position-sensitive scintillation detectors Main modules: Detector builder Simulator Reconstructor Data importer and filter Data explorer & visualizer GAMMA-64 GE MaxiCam 11

ANTS - II An example of advanced simulations: gamma camera with pinhole collimator, lead mask and gamma source 12

GAMMA-64 Miniature gamma camera prototype with SiPM readout LYSO crystal 30x30x5 mm 8x8 array of SensL SiPM Directly coupled to MAROC input Adjustable mechanical design 13

GAMMA-64 First data were obtained in the beginning of March 2014 57Co source (122 kev) Lead mask (2mm holes on 4mm grid) Statistical event reconstruction done with ANTS-II package 14

GAMMA-64 57 Experiment Simulation Co source Bar phantom (2.5 mm bars, 2.5 mm space) 45 degrees 15

Commercial gamma camera upgrade A decommissioned commercial gamma camera modified to work with MAROC DAQ 16

Commercial gamma camera upgrade A first stab at adaptive reconstruction Data were recorded with a 22Na source placed axially at the back cover of the camera LRFs from CoG Iteration with inner PMTs All PMTs 17