UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

Similar documents
UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring

Smart Energy & Power Quality Solutions. UMG 507 Power analyser

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

POWER SIMPLY SAVE. Catalogue Catalogue 2017

Smart Energy & Power Quality Solutions UMG 96RM. Multifunction power analyser

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

MIC-2 Multi-instrument DATA SHEET

FOUR FUNCTIONS ONE SOLUTION

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Smart Energy & Power Quality Solutions. UMG 103-CBM energy meter with memory COMPACT, BEST-PRICED & SAFETY

MIC-2 MKII, Multi-instrument DATA SHEET

Smart Energy & Power Quality Solutions. ProData data logger. Data collection and recording

UMG 511. Class A power quality analyser. Reporting Homepage

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Smart Energy & Power Quality Solutions. UMG 96RM-PN The communications professional. Multifunctional power measurement device with PROFINET interface

Mains Monitoring Instruments 4

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Transienten. Datenspeicher

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

You can find us everywhere.

THE NEXT TRANSDUCER GENERATION

Digital Multifunction Meters. Digital Multifunction Meters

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Power Management System. Multifunction Measuring Instruments

PMC 530 Series Advanced Multifunction Meter

DIRIS A. Multifunction measurement units for managing your electrical networks

ANALIZZATORE DI RETE TRIFASE 90A

Power Meter PowerMonitor 500

A2000 Multifunctional Power Meter

Three-Phase Power Quality Analyzer PowerPad Model 3945

with Backlight Graphic LCD Screen

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

EngyVolt RV12 and RV15

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Electronic Submeter with Advanced WiFi Ethernet Capability

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

Rapidus Power Factor Controller

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Energy Management Energy Transducer Type ET112

INTEGRA DIGITAL METERING SYSTEMS

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

PowerPad III Model 8435

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

DIRIS A-30 Multifunction power metering & monitoring device - PMD

Multifunction Transducer MT440

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

USER MANUAL 2012 V1.1

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

DS 500 Intelligent chart recorder for compressed air and gases

ATV1200A kv kva

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

PMC-630 Series Advanced Multifunction Meter

4 Is this model available for special primary current and special primary voltage?

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Energy Management Solutions

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

WM20. Power analyzer for three-phase systems. Benefits. Description

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

Acuvim L Series. Multifunction Power Meters FEATURES

Monitoring various parameters with one power meter!

Power Management System. Measuring Devices for Power Distribution

MP7. Uninterruptible Power Supply

Revenue Grade General Specifications

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System

MODULAR CIRCUIT MONITORING SYSTEM

Transcription:

UMG 96RM UMG 96RM Universal measurement instrument The UMG 96RM is a very compact and powerful universal measurement device designed for use in low and medium voltage distribution systems. In addition to recording a large quantity of electrical parameters, this innovative measurement instrument offers additional functions such as the measurement of harmonics up to the 40th order. Continuous sampling with 426 samples/ cycle ensures high resolution for each measured value and provides an effective energy management tool for fault analysis and power quality monitoring. There are several models within the UMG 96RM range to suit various applications from the basic model to those with 256MB memory and various communication protocols. Areas of application Measuring, monitoring and checking electrical parameters in energy distribution systems Recording of load profiles for energy management systems (e. g. ISO50001, EN16001) Collection of energy consumption data for cost center analysis Measurement value generator for building management systems or PLC (Modbus) Monitoring of power quality characteristics, e.g. harmonics up to the 40th order

Universal measurement instrument UMG 96RM UMG 96RM Compact high performance The compact and powerful multi-function measurement device for energy measurement. The UMG 96RM is equipped with a powerful, innovative microprocessor. The sampling rate of all measurement channels at 426 samples/cycle enables continuous acquisition of several hundred measurement values at high resolution. Main features Measurement in solidly grounded, high resistance grounded. or ungrounded systems LCD-Display with backlight True RMS measurement (TRMS) Continuous sampling of voltage and current inputs with 426 samples/cycle Harmonic analysis up to the 40th order 7 Energy meter for L1, L2, L3 and sum 8 tariffs High measurement accuracy, effective energy class 0.5,...accuracy V/I, 0.2% RCM (Option) High reliability and long lifespan Including extensive package of GridVis software up to 6 current inputs Applications The UMG 96RM is a latest generation measurement instrument from Janitza. It is intended for measuring, recording and monitoring electrical parameters (True-RMS) in low and medium voltage systems (1 and 3-phase systems with a neutral conductor). Among the characteristics of this measurement instrument are the compact construction (96x96 mm), LCD backlight and the measurement of harmonic currents and voltages in each conductor. The UMG 96RM collects electrical energy consumption, standard electrical parameters such as current, voltage, frequency, power and power quality characteristics, e.g. harmonics, up to the 40th order. The high measurement accuracy, compact construction, extensive measurement data, multi-faceted protocol for integration into upstream systems and economical design make the UMG 96RM stand out as a very competitive offering. The voltage measurement inputs are designed for direct measurement in low voltage systems in which nominal voltages up to 300V to ground and surge voltages up to over-voltage Category III can occur. System integration can be readily achieved (energy management system, PLC, SCADA, BMS) through the large choice of interfaces and protocols. The GridVis software, which is included as part of the package, provides the basis for energy management systems and power quality investigations.

Universal measurement instrument UMG 96RM Typical applications In order to achieve a sustainable reduction in energy costs, an overview of the energy consumption and the energy flow in the electrical system is first required. The UMG 96RM range of universal measurement devices can be used to create energy management systems (ISO 50001/EN16001), cost center management or to monitor power quality, among other applications. Energy data acquisition & load profile With the help of the UMG 96RM acquisition of detailed energy data and the load profile beomes a simple task. This is essential for tracking energy efficiency and to avoid overloads in the energy distribution system. Cost center analysis It is becoming progressively more important in industry to be able to assign energy costs to particular products. To do this it is desirable to determine energy costs for individual processes and to charge them accordingly. Cost analysis also allows employees to focus on specific cost optimization and conservation of energy. Energy management systems (ISO 50001/EN 16001) Energy management systems per standard ISO50001/ EN16001 are essential for monitoring continuous improvements in energy efficiency and reduction of costs. The UMG 96RM range of universal measurement devices can play an important role in establishing an effective energy management system. Transparency of energy supply A multi-stage and scalable measurement system allows a higher degree of transparency into the energy supply history. Continuous measurement with high resolution meters is the only way that sporadic events can be analyzed and corrective solutions identified. Power quality monitoring The UMG 96RM gives indispensable information about inadequate power quality and enables measures to be undertaken to address recurring problems. This can result in the prevention of production stoppages, significantly longer service life for manufacturing assets leading to improved sustainability and return on investment.

Universal measurement instrument UMG 96RM Versions of UMG 96RM The UMG 96RM is available in different versions to meet the various specific market application requirements. The differences between the models are primarily the interfaces, protocols and configuration of the inputs and outputs. The basic device is equipped with a fast RS485 interface with Modbus protocol and 2 digital outputs. Basic device UMG96RM The fast RS485 interface with the Modbus protocol and 2 digital outputs allows quick and costeffective monitoring of the power quality and energy consumption. Profibus and digital IOs UMG96RM-P 4th current transformer input UMG96RM-CBM/-E/-P The growth of non-linear loads leads to increasing pollution effects on the electrical supply, in particular overloading of the neutral conductor by harmonic currents. The N-line can be continuously monitored via the 4th current input. The Profibus connection is used frequently in systems where the UMG 96RM is to be incorporated into the automation environment (PLC controllers). Temperature input and analogue output UMG96RM-E The wide choice of inputs and outputs enables effective integration into upstream systems. The temperature input can be used to send a signal to protect against over temperature in low voltage distribution systems, the transformer or a server cabinet. M-Bus UMG96RM-M The M-Bus field bus connection is for the acquisition of data collected from various different consumption meters, such as water, gas, heat or electrical current. The UMG 96RM can be simply and cost-effectively integrated into consumption data acquisition systems via the M-Bus connection. Ethernet (TCP/IP) UMG96RM-E Digital IOs UMG96RM-Various Increasingly communications are moving from typical field bus to Ethernet (TCP/IP). The UMG 96RM Ethernet connection provides a simple integration into the network with a fast and reliable communications architecture. Along with network transparency Smart Grid programs are promoting the active control of energy flow and power consumption. The UMG 96RM offers a wide choice of I/O configurations for intelligent integration and control tasks.

Universal measurement instrument UMG 96RM Router SPS Software Systems Solidly grounded, high resistance grounded and ungrounded systems 3 phase and 4 phase systems Up to 4 single phase circuits Interface RS 485 Profibus (Option) M-Bus (Option) Ethernet (Option) USB (Option) 4 digital inputs (Option) Pulse input Logic input Status monitoring HT/LT conversion 6 digital outputs (Option) Pulse output kwh/kvarhv Switch output Limit value output Logic output Remote over Modbus / Profibus 3 digital inputs-/outputs (UMG 96RM-E) Either inputs or outputs 2 analogue inputs (UMG 96RM-E) Analogue, temperature or RCM inputs Temperature measurement input PT 100, PT 1000 (Option) Communication Modbus (RTU) Profibus DP/V0 (Option) TCP/IP (Option) Measurement accuracy Class: 0.5S ( /5A) class Current: 0,2 % Voltage: 0,2 % Memory (Basic unit: without data memory, energy, min and max values are stored in the EPROM) 256 MB Flash Power quality Harmonics up to 40th THD-V THD-I Unbalance

Scope of operation and technical data UMG 96RM Overview of product models Three/four phase power analyzers; 50/60Hz; current transformer.../1/5a; including GridVis programming and analysis software Interfaces Supply voltage 95...240 V AC, 80...340 V DC ±10% of nominal range Digital inputs Digital-/ pulse output Digital inputs/ outputs ( either 3 inputs or 3 outputs) Analogue inputs Temperature/ residual current, combinable 4th current transformer input Memory size Clock and battery RS 485 Profibus M-Bus Ethernet 100baseT USB Type Item number - 2 - - - - - - - - - UMG 96RM 52.22.031 4 6 - - 256 MB * - - UMG 96RM-P 52.22.034-2 - - - - - - - - - UMG 96RM-M 52.22.039 ** - 2 3 2 256 MB * - - - UMG 96RM-E 52.22.033 4 6 - - 256 MB * - - - UMG 96RM-CBM 52.22.032 24-250VAC 20-300VDC - - - - - - - - - - - UMG 96RM-EL 52.22.056 ** Accessories Fastening clamps for UMG 96 RM (52.22.001), UMG 96 RM-M (52.22.003) and UMG 96RM-EL (52.22.006). Clamps for fastening the measurement instrument - with front panel thickness from 6 mm or with heavy vibrations. 52.22.251 For parameterization of the basic unit (item-no. 52.22.001) an interface converter and GridVis software is recommended. * 192 MB available for recordings = Included = Not possible ** Features Three wire/four wire / Sampling frequency 426 samples/cycle Energy tariffs 4 x kwh / 4xkVArh Harmonics 1..40th Distortion factor THD-V / THD-I in % Unbalance Clock +/- 1 min per month Operating hour meter Communication RS 485 9.6, 19.2, 38.4, 57.6, 76.8, 115.2, 921.6 kbps, but NOT Version M and EL Profibus DP Plug, sub D 9-pole up to 12Mbps, Version P Protocols Interfaces M-Bus, Version M Ethernet RJ45-sockets, Version E and EL USB, Version P and CBM Webserver, Version E Modbus RTU, but NOT Version M and EL Profibus DP V0, Version P Modbus TCP/IP, Version E and EL Modbus over TCP, Version E Modbus-Gateway, Version E HTTP Homepage (configurable), Version E SMTP E-Mail, Version E SNMP, Version E SNTP Time synchronization, Version E TFTP Automatic configuration, Version E FTP File Transfer, Version E DHCP, Version E

Scope of operation and technical data UMG 96RM General technical data Nominal voltage 3-phase 4-wire grid (L - N, L - L) 277/480 V AC Overvoltage category 3-phase 3-wire grid (L - L) Quadrants 4 Continuous measurement 480 V AC 300 V CAT III Scanning rate 50/60 Hz Per channel 426 samples/cycle Mounting Front panel installation Working temperature range 4... 131 F (-10 55 C) Connectable conductor (U/I) Single wire, multi-wire, fine-wire 28 AWG-14 AWG (0.08-2.5 mm²) pin cable lugs, ferrule 16 AWG (1.5 mm²) Protection class According to EN 60529 IP 20 (NEMA 1) Measurement values Measurement parameter Display range Measurement range at scaling factor 1 L1 L2 L3 Sum Lowest value Average value Maximum value Measurement accuracy Current 0.. 9999 ka 0.. 5 A +-0.5 % Current calculated in N 0,03.. 9999 ka 0.03.. 25 A +-1.0 % Voltage L-N 0.. 9999 kv 10.. 300 V +-0.2 % Voltage L-L 0,0.. 9999 kv 18.. 520 V +-0.2 % Frequency (U) 45,00.. 65,00 Hz 45.00.. 65.00 Hz +-0.05 % Effective power per phase 0 W.. 9999 GW 0 W.. 1.8 kw +-0.5 % Apparent power per phase 0 VA.. 9999 GVA 0 VA.. 1.8 kva +-0.5 % Reactive power per phase 0 var.. 9999 Gvar 0 var.. 1.8 kvar ind. +-1.0 % Effective power, sum 0 W.. 9999 GW 0 W.. 5.4 kw +-0.5 % Apparent power sum 0 VA.. 9999 GVA 0 VA.. 5.4 kva +-0.5 % Reactive power, sum 0 var.. 9999 Gvar 0 var.. 5.4 kvar ind. +-1.0 % cos-phi 0.00 kap... 1.00.. 0.00 ind. 0.00 kap... 1.00.. 0.00 ind. +-1.0 degree Effective energy, consumed 0.. 999,999,999 kwh Class 0.5(5A) Reactive energy, inductive 0.. 999,999,999 kvarh Class 1(5A) Operating hour meter 0.. 999,999,999 h +-2 min per day Power quality Harmonics, 1-40 harmonic Current, voltage L1, L2, L3 Accuracy class 1 Distortion factor THD-V in % L1, L2, L3 Accuracy class 1 Distortion factor THD-I in % L1, L2, L3 Accuracy class 1 Recorder for threshold events, for units with memory Periphery Digital inputs As a status or pulse input refer to order details Digital outputs As a switch or pulse output refer to order details Analogue outputs 4...20mA, Temp. or RCM refer to order details Password protection Software GridVis

UMG 96RM Side and rear views each show a combination of the various versions just to indicate overall dimensions and the locations of interfaces and connectors. For the specific design of an individual version, please refer to our operation manual. Combination of the various versions External power supply with wide voltage range. The external battery compartment enables the battery to be replaced whilst the system is running. Ethernet connection for fast and secure integration into the network, or USB-connector for configuration. The large number of digital inputs and outputs (up to 4 x IN and 6 x OUT) enables the integration of subordinate measurement points in the same way as the UMG 96RM is integrated into upstream systems. The 4th current transformer input enables monitoring of the N-line or a 4th single phase load. Dimensional drawing Typical connection option (UMG 96RM-P) 2.91in 74mm 74 2.24in 57mm 57 3.78in 96mm 3.58in 91mm 3.94in 100mm The compact design......particularly for applications with tight spaces. The shallow depth allows installation even where space is limited, for example in subdistribution panels. Panel Cut Out Dimensions 3 5/8 +/- 1/32 in x 3 5/8 +/- 1/32 in 92 +/- 0.8 mm x 92 +/- 0.8 mm Omniverter Inc. 570 Hood Road, Unit 20 Markham Ontario L3R 4G7 CANADA Tel: 416-849-2299 US Tel: 440-290-4499 Fax: 416-849-2298 www.omniverter.com info@omniverter.com 1214 Exclusive North American Partner of