Backplane. System integration. Backplane

Similar documents
Backplane. Allen-Bradley. System integration. Backplane

Backplane. System integration. Backplane

G.M.International Termination Boards

Innovation for system integration

G.M.International Termination Boards

Intrinsically Safe Barriers

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

iologik 4000 Series (M) Modules

APPLICATION GUIDE. Interface Modules IM Series.

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Redundant System Redundant System P9-1-1

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation

S800 I/O ABB Automation

S-series Horizontal Carriers

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Your Global Automation Partner. excom I/O System

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D.

M-series Intrinsically Safe I/O

S-series Horizontal Carriers

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

General Specifications

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

E-STOP relays, safety gate monitors

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Analog Output Isolators

General Specifications

S-series Mass Connection Solutions

The N-IO System Contributing to the Innovation of the DCS Engineering Environment

vacon nx user manual basic i/o boards expander i/o boards adapter i/o boards ac drives

E-STOP relay, safety gate monitor

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

E-STOP relays, safety gate monitors

TYPE APPROVAL CERTIFICATE

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

Installation Instructions

Installation Instructions

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

CO General Specifications GS48D62Z00-00E-N GENERAL. ProSafe-COM extended communication system

General Specifications

General Specifications

Features and Benefits. Certifications

Safety manual. This safety manual is valid for the following product versions: Version No. V1R0

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

SITOP in the SIMATIC Design

AI561 Analog Input Module

S900 Remote I/O System Intrinsic safety in the field ABB

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Technical Information Fieldgate SFG500

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

PA ROUTERS. The following criteria can be applied when choosing the network transition:

E-STOP relays, safety gate monitors

Safety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

POINT I/O Family. Chapter. Overview

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Fiber Optic Selector Guide for PLC & Serial Communication Networks

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MGate 5102-PBM-PN Series

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

DI561 Digital Input Module

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

MIC-2 MKII, Multi-instrument DATA SHEET

Power Meter PowerMonitor 500

General Specifications

Two-hand control unit

DeltaV SIS TMConditioning Components

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Intrinsically Safe Temperature Concentrator System

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Safe monitoring relays

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

TF501, TF521 Terminal Bases

iologik E1200H Series

Transcription:

Backplane System integration Backplane

Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible connection set-up to fit the different DCS systems Connection for both master and slave PLC and connection between the two Redundant power supply Easy access via HART modem HART point-to-point connectivity 5 years guarantee Safety The backplane gives you the greatest possible guarantee of a faultless connection as wiring is carried out automatically on our state-of-the-art SMT machine. Each backplane is given a unique identification which is controlled and documented according to our ISO 9001 quality system. This is your guarantee for delivery of identical backplanes, be it for OEM projects or extensions of existing installations with the same configuration. Cost saving The backplane is the optimum solution for installations with several built-in devices. The wiring between the device and the SCADA system has been replaced by a multi-cable which reduces wiring costs to a minimum. Furthermore, the start-up time is reduced to an absolute minimum. HART connectivity Point-to-point HART connectivity can be achieved by making a separate cable line for the HART signals. Alternatively, a HART pocket can be installed on the output connection on the devices 5106 & 5107 for easy measurement with HART modem. Redundant system with diagnostics The backplane can be set up for redundant connection, covering both signals and power supply. By power failure or short circuit, a potential-free signal is fed back to the PLC/DCS system. The power lines are also fuse-protected. 2

Intelligent surveillance The redundant power supply connection ensures the best possible operating conditions. In case of a supply interruption, an alarm signal is immediately transmitted via the relay output. The output signals and the supply to each device can be looped through a fail-safe controller which will then determine whether a device is on or off. World wide safety standards The many versatile devices in the 5000 series are certified for world wide installation with approvals for: ATEX UL GOST The devices have also passed vibration tests according to the DNV marine standard. To further ensure a reliable and durable design, the backplane board is made of galvanised steel. 3

For safety applications The backplane 7300 series also comes in a version suitable for all PR s system 9000 barriers with SIL - full assessment according to IEC 61508. The 9000 series features the unique 4501 front display that offers you: Configuration in no time Overview of the process Password protection Quick copying of the configuration With the backplane 7300 series we have cultivated the art of achieving the largest number of possible combinations while still keeping it simple. The 7300 series is thus the optimum solution for: Analogue input signals Analogue output signals Digital input signals Digital output signals Temperature input signals Devices with up-to-date intrinsically safe design The backplane is designed for intrinsically safe devices which eliminates the need for complex and expensive grounding. In addition to the intrinsically safe design, the devices are also characterised by a high degree of isolation which ensures noise-free signal conditioning as well as increased safety. Something more than usual The unique design combined with the flexibility of the PR devices allow the backplane to handle signals in more than the usual way, e.g.: Mixing of signals Duplication of signals Point-to-point HART connnectivity 4

C O M M U N I C AT I O N F O U N D AT I O N Grounding terminal The ground connection, on the connector board, is easy to install. A redundant grounding can also be established in order to optimise safety. DIN rail click-on system All devices for the backplanes are standard stock units available on a day-to-day basis. They are mounted on the backplane with a reliable click-on system. Plug n play The backplane comes in 2 standard sizes with room for either 8 or 16 devices allowing up to 32 channels. All devices from the PR 5000 series in both Ex and non-ex versions are suitable. The standard connection allows integration with the following system vendors: ABB Automation Allen-Bradley Emerson Foxboro GE-Fanuc Honeywell Invensys Mitsubishi Schneider Electric Siemens Yokogawa Tagging strip Easy servicing is also taken into account with the backplane as a tagging strip is provided. Mounting The backplanes are designed for fast and easy installation directly in the switch cabinet. They can be installed both HORIZONTALLY and VERTICALLY to suit the different applications. Optimisation of spare parts stock A backplane solution helps optimise your stock of spare parts as the same type of device can be used for both backplane and conventional DIN rail mounting. 5

Block diagram BACKPLANE 7300 A 2AT Supply RE1 Supply PLC / DCS Redundant device 2AT connection connection Backup RE2 Backup Cross wiring Power failure RE1 RE2 BACKPLANE 7300 B 2AT Supply RE1 Supply PLC / DCS Assembly board Redundant device 2AT connection connection Backup RE2 Backup 2AT Cross wiring Cross wiring Supply 2AT RE4 Backup Power failure RE1 RE2 RE3 RE4 6

Backplane order code: 7300 Type Devices Channels Configuration Input / output 7300 8 : A 16 : B 1 : 1 2 : 2 8 devices - single / dual : A 8 devices - redundant : B 16 devices - single / dual : C 16 devices - redundant : D Analogue & : 1 temperature input Analogue output : 2 Digital (5202B2) : 3 Digital (5202B4) : 4 Digital (5203) : 5 AI + AO : 6 Cable order code: 7301 Type System vendor Input / output connector Cable length 7301 Yokogawa - Centum CS3000-R3 : J1 MIL 40 : A 1 m : 1 Yokogawa - ProSafe : J2 MIL 50 : B 2 m : 2 3 m : 3 5 m : 4 7.5 m : 5 10 m : 6 12.5 m : 7 15 m : 8 20 m : 9 25 m : 10 30 m : 11 35 m : 12 7

Mechanical specifications Output connector I Output connector II 5.5 mm 20 mm 240 mm 225 mm BACKPLANE 11 mm 205 mm 152.3 mm H x W with 8 devices 145.6 mm D with 8 and 16 devices Assembly board 455 mm 440 mm BACKPLANE Output connector I 7 1 0 1 B A C K P L A N E Output connector II 205 mm 152.3 mm H x B with 16 devices Electrical specifications: Specifications range: -20 to +60 C Common specifications: Supply voltage... 20.4...27.6 VDC Internal consumption, without devices.. 2 W (7300A) Internal consumption, without devices.. 4 W (7300B) Fuse... 2 A SB / 250 VAC Isolation voltage, test / operation... 500 VAC / 50 VAC Dimensions with devices (HxWxD)... 205 x 240 x 145.6 mm Dimensions with devices (HxWxD)... 205 x 455 x 145.6 mm Weight 7300A (without devices)... 1200 g Weight 7300B (without devices)... 2400 g Relay outputs: Max. voltage... 50 VRMS Max. current... 1 A / AC Max. AC power... 50 VA Max. current at 24 VDC... 1 A Observed authority requirements: Standard: EMC 2004/108/EC... EN 61326-1 8

BACKPLANES for Centum CS3000 R3 ProSafe 9

Backplanes YOKOGAWA Centum CS3000 R3 BACKPLANE Signal Part number Yokogawa Centum VP - card type PR devices AI AO DI DO 7300A2A6 7300A2A1 7300A2A2 7300B2C3 7300B2C5 AAI841 AAI143 AAI543 AD151, ADV157 ADV551, ADV557 5104, 5106 (HART), 5114, 5115 & 5116 5105 & 5107 (HART) 5202B2 (2 relays) 5203 10

Backplanes YOKOGAWA - AAI841 Type: 8 x AI & 8 x AO PR item no.: 7300A2A6 PR devices: 5104 & 5105 Cable connection: 7301J1Axx - AAI841 (xx specify length) For AAI841 (MIL 40-pin) MIL 40-pin female Supply Principle diagram: 205 mm 240 mm AAI841 as 4-wire input: Input + Current + 42 13 CH1 Gnd. Current - 41 11 OUT+ PR5104 43 22 CH1 Gnd. OUT - 41 21 PR5105 OUT+ 39 40 AAI 841 output: 24 23 YOKOGAWA AAI841 Setting pin: 4-wire input 11

Backplanes YOKOGAWA - AAI143 Type: 16 x AI PR item no.: 7300A2A1 PR devices: 5104 Cable connection: 7301J1Axx - AAI143 (xx specify length) For AAI143 (MIL 40-pin) MIL 40-pin female Supply Principle diagram: 205 mm 240 mm Output + Output - Output + Output - 42 41 52 51 PR5104 13 CH1 11 23 CH2 21 Current + Gnd., backplane V+ Current - 50 YOKOGAWA AAI143 48 11... 18 12

Backplanes YOKOGAWA - ADV151 Type: 32 x DI PR item no.: 7300B2C3 PR devices: 5202-2 channels Cable connection: 7310J1Ax - ADV151 (xx specify length) For ADV151 (MIL 40-pin) MIL 40-pin female 205 mm 455 mm Note: The extemally supplied power 24 VDC to COM 16 and COM 17-32 must be the same polarity. 32 digital inputs: NAMUR + 43 12 CH2 Power supply, Input backplane 51 21 V+ 50 Principle diagram: Rs Rp Input NAMUR + 41 53 CH1 11 22 Gnd., backplane V+ 48 YOKOGAWA ADV151 11... 18 PR5202 Gnd. +24 VDC 13

Backplanes YOKOGAWA - ADV551 Type: 32 x DO PR item no.: 7300B2C5 PR devices: 5203-2 channels Cable connection: 7301J1Bxx - ADV551 (xx specify length) For ADV551 (MIL 50-pin) MIL 50-pin female 205 mm 455 mm Note: Connect the positive (+) side of the externally supplied power 24 VDC, and the negative (-) side to COM 1-16 and COM 17-32. Principle diagram: 14 Output + Output - Output + 43 41 53 CH2 Output - 51 21 PR5203 12 CH1 11 22 Gnd., backplane Gnd., backplane V+ V+ Gnd., backplane 32 digital outputs: 50 48 YOKOGAWA ADV551 11... 18

Backplanes YOKOGAWA ProSafe BACKPLANE P ro S a f e R S BACKPLANE Signal Part number Yokogawa ProSafe RS - card type PR devices AI 7300A2A1 SAI143 (HART) 5104, 5106 (HART), 5114, 5115 & 5116 AO 7300A1A2 SAI533 5105, 5107 (HART) DI 7300B1A3 SDV144 5202B2 (2 relays) DO 7300B2C5 SDV541 5203 15

P ro S a f e R S Backplanes YOKOGAWA - SAI143 Type: 16 x AI PR item no.: 7300A2A1 PR devices: 5104, 5114, 5115 & 5116-2 channels Cable connection: 7301I1J2Axx - SAI143 (xx specify length) For SAI143 (MIL 40-pin) MIL 40-pin female Principle diagram: 205 mm 240 mm Supply Output + Output - Output + Output - 42 41 54 52 Current + 13 CH1 11 23 Gnd., backplane V+ CH2 21 Current - 11... 18 PR5104 16

Backplanes BACKPLANE P ro S a f e R S YOKOGAWA - SAI533 Type: 8 x AO PR item no.: 7300A1A2 PR devices: 5105-1 channel Cable connection: 7301J2Axx - SAI553 (xx specify length) For SAI533 (MIL 40-pin) MIL 40-pin female Supply Principle diagram: 205 mm 240 mm Input + Current + 42 13 Gnd. Current - 41 11 PR5105 V+ 42 13 V+ Input + Current - 41 PR5105 17

P ro S a f e R S Backplanes YOKOGAWA - SDV144 Type: 16 x DI PR item no.: 7300B1A3 PR devices: 5202-1 channel For SDV144 (MIL 50-pin) Cable connection: 7301J2Bxx - SDV144 (xx specify length) MIL 50-pin female 205 mm 455 mm Input + 42 13 Current + Principle diagram: 18 Rs Rp Gnd. Current - 41 11 V+ PR5202 43 12 Input + Current - 41 11 PR5202 V+

Backplanes BACKPLANE P ro S a f e R S YOKOGAWA - SDV541 Type: 16 x DO PR item no.: 7300B2C5 PR devices: 5203-1 channel Cable connection: 7301J2Bxx - SDV541 (xx specify length) For SDV541 (MIL 50-pin) MIL 50-pin female 205 mm 455 mm Input + 43 12 Current + Principle diagram: Gnd. Current - 41 11 PR5203 OUT+ 43 12 OUT+ Gnd. OUT - 41 11 PR5203 19

Signals the Best Around the world, PR electronics helps create increased efficiency and safety via industrial signal conditioning. The means to achieve this is reliable, flexible and user-friendly devices, thorough technical documentation, fast delivery and competent technical support in short, all aspects which are of importance to our customers. This is why PR electronics always...»signals the Best«20 1049UK-01 (1106)