M20 Metallurgical Microscope User s Manual. Fein.

Similar documents
Mi50 Inverted Microscope User s Manual. Fein.

M40 Microscope User s Manual

R40POL Microscope User s Manual

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

3025 MICROSCOPE SERIES INSTRUCTIONS

Polarization Microscope. Omano OM349P Series. User Guide

OMM200 and OMM200T. Metallurgical Microscope

optech Reflected Metallurgical Microscope Model SM lnstruction Manual OPTICAL TECHNOLOGY

Instruction Manual. B1 Series. Copyright 02/02 Motic Microscopes, European Division

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

Instruction Manual. B3 Series. Copyright 02/02 Motic Microscopes, European Division

M40 and M40RT Series. Metallurgical Microscopes

Richter Optica. Instructions for Model: HSX1 High School Microscope

Richter Optica. Instructions for Model: MDS1 Compound Microscope

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

Richter Optica. Instructions for Models: UX1B Binocular and UX1T Trinocular Laboratory and University Biological Microscope

M50 and M50RT Series. Brightfield / Darkfield Metallurgical Microscopes

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

Operation Manual. for Micromas ter I Micros copes. T his manual covers catalog numbers : S 11031, S 11033, and S 11035

Palomar. Metallurgical Microscopes. Palomar Metallurgical Microscopes

EXAMET-4 MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Richter Optica. Instructions for Model F-1 Compound Microscope

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

IM Series INSTRUCTION MANUAL. Model IM-3MET

User Manual. Binocular Compound LED Microscope. MicroscopeNet.com

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

For documentation the instrument is available with a trinocular head which permits mounting of a video or digital camera system.

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Symbio Microscope. L1500 Series. Biological Upright Compound Microscopes. Operating Manual

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

INSTRUCTION MANUAL POLARIZING & ORE MICROSCOPES. Polarizing Microscopes. Ore Microscopes. Model: NYMC62B00

For documentation, both instruments are available with a trinocular head which permits mounting of a video or digital camera system.

Comprehensive Scope 2. Instruction Manual T-19011C - Monocular T-19021C - Dual Viewing T-19031C - Binocular T-19041C - Trinocular

Whitney. Polarizing Microscopes. Whitney Polarizing Microscopes

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Operation Manual. VWR Inverted Microscope. (Version 1.0.0) VWR Inverted Microscope VWR Inverted Microscope.

MANUAL Series ZOOM STEREO MICROSCOPE MANUAL

User Manual. Trinocular Stereo Microscope

EXAMET-5 MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Fisher Scientific Microscopes

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Operation Manual (Version 1.0.0)

User Manual. Trinocular Stereo Microscope

MANUAL 3072 STEREO MICROSCOPE SERIES

INSTRUCTIONS FOR MODEL C-1028 COMPOUND MICROSCOPE

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Z10 SERIES Z10 Z8 Z6 MANUAL ZOOM STEREO MICROSCOPES

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Swift SM100 Series Stereo Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

12100 Polarizing MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Introduction to the Microscope. Hanan Jafar BDS.MSc.PhD

148 Series. User s Manual

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Lab 5 Microscopy. Introduction. Carrying the Microscope. Depth of Focus. Parts of the Compound Microscope. Magnification

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

INSTRUCTIONS FOR STEREOSCOPIC MICROSCOPES CATALOG NUMBERS (120V) (220V) (120V) (220V)

Eclipse L300D / L300

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Great Bay Community College Document Number: Corporate Drive Revision Number: 3

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, TX Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Polarizing Microscope LPM-A10. Features. Applications. Specifications

Fein. RB50 Series Research Microscopes

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Operation Manual (Version 1.0.0)

INTRODUCTION - VetScan HDmicroscope

Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope

Eco D-ELS-4 Stereo Microscope. Instruction Manual

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

User instructions Stereo microscope

Lab 4 - The Microscope

BA210 BASIC BIOLOGICAL. Microscope

Swift SM100 Series Stereo Microscope

SeBa Digital Imaging Systems

Quick Set-up Guide for the Biomedx Configured Olympus CX43

Transmission Polarizing Microscope OM239

BIOLOGICAL MICROSCOPE

AZ-STD Diascopic Stand and AZ-STGD DIA Stage Instructions

Hand sectioning a mushroom

POLARIZING MICROSCOPE LPM-A1 Series.

USE OF THE MICROSCOPE

Digital Comprehensive Scope 2. Instruction Manual T-19541C T-19641C

Binocular Compound Microscope Instruction Manual

MICROSCOPE USER MANUAL

ECLIPSE L200ND / L200N

Microscopy Redefined. Fisher Scientific Premier Microscopes

ColorMaxLP Label Roll Rewinder

BX51/52-P INSTRUCTIONS POLARIZING MICROSCOPE

INSTRUCTION MANUAL for STEREO MICROSCOPE FUTURO EDU CAM

User instructions Stereo zoom microscope

OLYMPUS STEREO MICROSCOPES I INSTRUCTION MANUAL I MODELS VMF,VMT&VMZ OLYMPUS

Olympus UNIVERSAL ILLUMINATOR LSD MODEL WITH TRANSFORMER TC

SM-6 Series. User s Manual

Transcription:

M20 Metallurgical Microscope User s Manual info@feinoptic.com

M20 Microscope Components Lamp Housing C-Mount Adapter Eyepieces Analyzer Objective Lens Coarse Focus Mechanical Stage Stage X-Y Control Fine Focus Focus Tension Adjustment 1

M20 Microscope Components Filter Adjustments for Green, Blue, Yellow Filters Polarizer Field Stop Adjustment Aperture Stop Adjustment Quintuple Nosepiece 1. Allen Tightening Screws 2. Revolving Nosepiece 3. Mechanical Stage 4. X/Y Axis Knobs for Stage 5. Light Intensity Knob 6. Polarizer 7. M20 Frame 8. 12v / 50w Halogen Housing 2

M20 Metallurgical Microscope Assembly Eyepieces Microscope Camera C-Mount Adapter Trinocular Head Lamp Housing Analzyer Reflected Illumination Arm Objective Lenses Polarizer Connect the reflected illumination arm to the microscope frame. Connect the lamp housing to the end of the reflected illumination arm. Connect the trinocular head to the top of the reflected illumination arm. Insert the eyepieces into the eyetubes. Insert the C-Mount adapter into the trinocular port. Thread the microscope camera onto the c-mount adapter. Insert the polarizer into the reflected illumination arm slot. Insert the analyzer on the opposite side of the reflected illumination arm. Screw the objective lenses into the nosepiece. Plug the microscope into the outlet. 3

M20 Metallurgical Microscope Assembly Use the allen key to loosen the screw (1) on the frame. Attach the reflected illumination arm and re-tighten the screw to secure. Use the allen key to loosen the screw on the back of the reflected illumination arm (1). Connect the dovetail mount of the lamp housing and insert into the illumination arm. Tighten the allen screw to secure in place. Use the allen key to loosen the top of the reflected illumination arm clamping screw (1). Attach the trinocular head onto the reflected illumination arm. Tighten the screw to hold the head in place. Remove the eyetube dust caps. Insert the eypeieces into the eyetubes. 4

M20 Metallurgical Microscope Assembly Lower the stage to its lowest position and screw the objectives into the nosepiece in ascending order. Make sure the main switch on the microscope is set to O off, and connect the power cord. Insert the Polarizer (P) into the slot on the right side of the reflected illumination arm. Insert the analyzer (A) into the left side of the reflected illumination arm. Rotate the polarizer dial so the light is darkest. A P Loosen the set screw and remove the dust cap from the trinocular port. Connect the c-mount adapter and tighten with the set screw. Screw the c-mount microscope camera onto the c-mount adapter. When not in use make sure to cover the c-mount or trinocular port to keep dust out of it. 5

M20 Microscope Operation Instructions Do not shake or drop the microscope. Do not expose the microscope to direct sun, high temperatures, high humidity, dust, or damp environments. Use a flat work surface. When moving the microscope use both hands, holding the back of the frame (1) and the front of the base (2) as shown in the image at right. Set the power switch to off O before replacing a bulb or fuse, and wait until the lamp is cool. Microscope uses 12v, 50W halogen bulb. (Part # R40POL-001). Voltage range of 100~240V (47-63Hz) is supported. Turn the rheostat control knob (1) to the minimum and turn the power switch on the back of the microscope frame to the on I position. Rotate the rheostat knob to increase or decrease the brightness of the illumination. Push up the aperture diaphragm lever to open the aperture diaphragm and let more light in. Place a sample on the stage and move the smallest magnification objective lens into the light path. Raise the stage up by rotating the coarse focus knob. Once the image is in focus, the fine focus knob can be used to finely adjust the focus. 6

M20 Microscope Operation Instructions The tension of the coarse focus is set at the factory. Should the tension become loose or too tight, it can be adjusted with the tension adjustment ring. Turn the tension adjustment ring counter-clockwise to increase tension. Turn clockwise to decrease the tension. Adjust the interpupillary distance of the eyetubes so that when looking through the microscope, the vision of both the left and right eyes join completely. The interpupillary distance is adjustable from 50-75mm. While looking through the right eyepiece, rotate the coarse / fine focus knobs to bring the specimen into focus. Now look through the left eyepiece only and rotate the diopter adjustment ring on the left eyepiece to bring the specimen into focus. When rotating the diopter adjustment ring, hold the lower part of the left eyetube steady while rotating the ring. Adjust the field diaphragm (FS) until the size of the image becomes almost identical to that of the field of view. The filter sliders are labeled above with IN. Green, blue and yellow filters are provided and each can be engaged by moving the slider up or down. 7

M20 Microscope Bulb Replacement Turn off and unplug the microscope prior to changing the bulb. 1. Unscrew the top of the housing with the allen wrench. 2. Lift the illumination cover. 3. Do not touch the bub with bare fingers. 4. Remove bulb from socket. 5. Replace bulb with 12v, 50w halogen (part #R40POL-001). 8

M20 Microscope Fuse Replacement Turn off and unplug the microscope prior to fuse replacement. The fuse box is installed below the power socket. Fuse: 5x20mm, 3.15A. 9

M20 Metallurgical Microscope Trouble Shooting TROUBLE POSSIBLE CAUSE SOLUTION Power cord is not plugged in. Plug in power cord. Bulb does not turn Power switch is not turned on. Turn on power switch. on. Bulb is burned out. Replace bulb. Fuse is burned out. Replace fuse. Rheostat is too low. Increase light intensity by rotating rheostat control. Bulb turns on, but field of view is dark. Field of view is obscured or not evenly illuminated. Dust or dirt is visible in the field of view. Image has glare (hot spots). Image is not sharp, contrast is poor and details are poorly visible. Image is blurry Field of view in one eye does not match that of the other. Coarse / fine adjustment knobs will not rotate easily or at all. Revolving nosepiece is not clicked into position. Field iris diaphragm is not open enough. Too many filters are being used. Field iris diaphragm is not properly centered. Field iris diaphragm is closed down too much. Revolving nosepiece is not clicked into position. A filter is in an intermediate position. Dirt or dust is on the specimen. Dirt or dust on the eyepieces. Dirt or dust on the objectives. Aperture diaphragm is closed down too much. Improper objective lens is being used. Objective lens is dirty. Dirt or dust on eyepieces. Objective is not fully in place in the light path. Specimen is not flat on the stage. Interpupillary distance has not been set. Incorrect diopter adjustment setting. Tension adjustment ring is set too tight. Click nosepiece into place. Open field diaphragm. Reduce filters being used. Center field iris diaphragm. Open the field iris diaphragm. Make sure nosepiece is clicked into position. Fully engage or disengage the filter. Clean the sample. Clean the eyepieces. Clean the objectives. Open the aperture diaphragm more. Use M20 metallurgical microscope objectives. Clean objective lens. Clean eyepieces. Click nosepiece into place. Place the specimen flat on the stage, or make sure the sample is flat. Adjust interpupillary distance. Adjust the diopter. Adjust tension adjustment. Stage falls. Tension adjustment ring is set too loose. Tighten tension adjustment. info@feinoptic.com 10