CSM_CJ1G-CPU4_P_DS_E_5_2

Similar documents
Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

CX-One Ver.4 CSM_CX-One_DS_E_8_2

CX-One Ver.4 CSM_CX-One_DS_E_10_2

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5

SYSMAC CS-series MECHATROLINK-II-compatible Position Control Units

Features various encoder interfaces and controls multiple analog servo drives at high speeds

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5

Connecting Sockets, Mounting Brackets, DIN Rails

Sub-trunk line Terminating Resistance Repeater Unit. Branch Line Repeater Unit. Sub-trunk line. Terminating Resistance.

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

CJ1W-ETN21 CSM_CJ1W-ETN21_DS_E_6_2

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

CJ series Position Control Units. High-speed, High-precision positioning with 1, 2, or 4 axes. Features. System Configuration

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

CJ1W-FLN22 CSM_CJ1W-FLN22_DS_E_3_1

CS1W-EIP21 CSM_CS1W-EIP21_DS_E_7_3

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Analog Input Unit. MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

NX-TS. NX-series Temperature Input Unit

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

CPU Unit. (Temperature control) (Position control) (Speed control)

S82S (3/7.5-W Models)

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

Number of input channels

Indicator (Square) Ultra Bright LED Type

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

CSM_PYF S/P2RF- -S_DS_E_2_5

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Data area memory capacity. 32K words DM: 32K words EM: None. 0.1 μs

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Electroformed Probe Pins XP3A

Solid State Relays with Failure Detection Function

CJ1W-SPU01-V2. CJ-series High-speed Data Storage Unit (SPU Unit) High-speed Collection of System Data. Features. System Configuration

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

Model A7BS

CJ1W-EIP21 CSM_CJ1W-EIP21_DS_E_9_2

Indicator (Square) Ultra Bright LED Type

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Practices Guide OMRON Standard IAG Library

NJ-Series Power Supply Unit NJ-PA/PD

EtherCAT master * Output port CPU Unit

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

CX-Process Tool INTRODUCTION GUIDE

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

E4C-UDA CSM_E4C-UDA_DS_E_12_2

SYSMAC CJ-series CJ1M CPU Units (with Ethernet function)

CJ-series Position Control Units (High-Speed type) Motion Control Capabilities with Unit Synchronization and Even Higher Speed.

Model NPN output PNP output Standard. configuration

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

M16-J M16-A M16-T

CJ1W-SPU01-V2. CJ-series High-speed Data Storage Unit (SPU Unit) High-speed Collection of System Data. Features. System Configuration

CJ1W-FLN22. CJ-series FL-net Unit. Connect to Multivendor Controller Networks. Features

Dimension A. Dimension B

NX-DA CSM_NX-DA_DS_E_3_1

CJ1W-EIP21. CJ-series EtherNet/IP Unit. Introducing the New EtherNet/IP Unit. More Than 180,000 Words of Tag Data Link Capacity!

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Model Number Structure

Reuse Terminal Block Wiring When Replacing PLCs. Terminal Block Conversion Adapters. Overview. Features. System Configuration

CX-Process Monitor Plus Ver. 2.0

EtherNet/IP Monitor Tool Operation Manual

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

SYSMAC CJ series Position Control Units. High-speed, High-precision positioning with 1, 2, or 4 axes. Features. System Configuration

Knob-type Selector Switches

Classification Applicable models Specification Type Model

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

NPN output. 200 mm. Type Cable length Model Remarks

CSM_NX-PG0 DS_E_4_4

Model Number Structure

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Machine Automation Controller NJ Series

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

SYSMAC CJ-series CJ2H CPU Units. Setting new standards in high-speed machine control. Features

Transcription:

CJ Series Loop CPU Unit CSM_CJ1G-CPU4_P_DS_E_5_2 Integrated Loop Control and Sequence Control Incorporate the engine for controlling analog values (e.g. temperature, pressure, flow rate) and the engine for executing sequence control in the CPU Unit. Deliver high-speed sequence control and high-speed, advanced analog value control in a single Unit. CJ1G-CPU45P Features High-speed execution of for multi-loop control with an operation cycle of 10 ms All s achieved by using only (operation s/designation of field input/output) Almost all control types freely achieved by combining Function with high-speed execution High-speed I/O refreshing with the CPU Unit using user link tables Designate I/O memory in the CPU Unit using registered tags Simulated software connections between Specify the order of operations in diagrams Easily create a SCADA interface with the HMI 1

System Configuration Analog Input/Output Unit * Control and operation External controller Loop Controller Allocated ITEMs Allocated ITEMs HMI Allocated ITEMs from control, operation, and external controller CPU Unit I/O memory HMI data in specified bank of EM area CSV tags specified. Computer Basic I/O Unit Field Terminals User link table Tag A Tag B Tag C Tag D I/O memory Userspecified words CSV tags specified. * Sequence table and step ladder Ex: Wiring of ITEM data in operation using FINS commands User Program *: Data is exchanged via allocated words in the CPU Unit's CIO Area CMND All s are achieved by software wiring between any combinations of. Input 1 of Analog Input Unit Field Terminal Analog Input Operation Addition /Subtraction Control PID Field Terminal Analog output Output of Analog Output Unit Input 2 of Analog Input Unit Field Terminal Analog input CJ1 Loop Control Units International Standards The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, US: culus, UC1: culus (Class I Division 2 Products for Hazardous Locations), CU: cul, N: NK, L: Lloyd, and CE: EC Directives. Contact your OMRON representatives for further details and applicable conditions for these standards. Product name CJ1G Loop-control CPU Units I/O capacity/ Mountable Units (Expansion Racks) 1,280 points/ 40 Units (3 Expansion Racks max.) 960 points/ 30 Units (2 Expansion Racks max.) Program capacity 60K steps 30K steps 20K steps 10K steps Specifications CPU Unit Data memory capacity 128K words (DM: 32K words, EM: 32K words 3 banks) 64K words (DM: 32K words, EM: 32K words 1 bank) LD instruction execution time 0.04 μs Current consumption (A) Loop Controller 5 V 24 V Number of : 300 max. Number of : 50 max. 1.06 (See note.) 1.06 (See note.) 1.06 (See note.) 1.06 (See note.) Note: Current consumptions include current for a Programming Console. Add 0.15 A per Adapter when using NT-AL001 RS-232C/RS-422A Adapters. Add 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapters. Model CJ1G-CPU45P CJ1G-CPU45P-GTC CJ1G-CPU44P CJ1G-CPU43P CJ1G-CPU42P Standards UC1, CE 2

Specifications Product name Model numbers Data exchange method with CPU Unit Item Words in Auxiliary Area in CPU Unit User allocations in I/O memory EM Area (bank number) allocations (for SCADA software) Setting Indicators Super capacitor backup data Super capacitor backup time Data stored in flash memory Backup from RAM to flash memory Recovery from flash memory to RAM Influence on CPU Unit cycle time Current consumption (supplied from Power Supply Unit) Standard accessories Loop-control CPU Unit Specification CJ1G-CPU@@P Loop Controller CPU Unit: Operation status, PV error input ON, MV error input ON, occurrence of execution error, database error, cold start ready for hot start command, flash memory backup in progress, changed, etc. CPU Unit Loop Controller: Hot/cold start command at power ON User memory tables used to allocate ITEM data for user-specified memory in the CPU Unit (CIO, Work, HR, DM, or EM Area (bank 0, but also banks 1 to 12 for Ver. 3.0 or later)). HMI used allocate ITEM data for Control, Operation, External Controller, and System Common in the specified bank of the EM Area in the CPU Unit. The real PV in calibration mode can be allocated (Ver. 3.0 or later). None Loop-control CPU Units: 2 LEDs (RUN and ready) All data (including Step Ladder Program commands), stored error log data CJ Series (CJ1G-CPU@@P): 5 min at 25 C (Backed up by the Battery in the CPU Unit.) Function data Executed from CX-Process Tool (as required). Automatic at power ON if startup mode is set for a cold start, or executed from CX-Process Tool (as required). Loop-control CPU Unit (CJ1G-CPU@@P): 0.8 ms max. (Depends on contents.) Loop-control CPU Unit: 1.06 A at 5 VDC Note: Increased by 150 ma when NT-AL001 Link Adapter is used. None 3

Function Specifications Item Operation method Number of Analog operation Sequential Control I/O Control Blocks Operation Blocks Step Ladder Program Field Terminal User link tables HMI System Common Function data preparation/ download Execution of Execution of Function execution conditions Function operation cycle Common to all For individual Function supporting high-speed operation LCB load rate External I/O response cycle Description Function method Total CJ1G-CPU42P: 71 max., CJ1G-CPU43/44/45P: 501 max. PID and other control s Alarm, square root operation, time operations, pulse train operation, and other operation s for various processes Logic sequence and step sequence s Analog I/O with Analog I/O Unit, contact I/O with Basic I/O Unit Analog data I/O and contact data I/O for CPU Unit Can be added to CSV tags. I/O for ITEM data for Control, Operation, External Controller, and System Common for CPU Unit System common operation cycle setting, run/stop command, load rate monitor, etc. LCB01: 50 max., LCB03: 300 max. 4,000 commands max. 100 commands/1 max. Can be divided into 100 steps max. 100 commands/1 step max. 80 max. 2,400 data max. Control/Operation Blocks LCB01: 50 max. + 20 send/receive words LCB03: 300 max. + 20 send/receive words System Common Block 20 send/receive words Real PV Input Monitor Area LCB01: 50 words max. LCB03: 300 words max. Single Function data prepared by CX-Process Tool (sold separately) and downloaded to Loop Controller Operation of all by turning power ON to the PLC (Hot or cold start can be specified.) For cold starts, data is transferred from flash memory to RAM. Function operation can be stopped by CX-Process Tool or FINS command. Hot start (state active before Board was stopped is continued before operation is started) or cold start (all state signals and internally held values are cleared before operation is started) is possible by CX-Process Tool or FINS command. Function operation can be stopped and hot start (state active before Unit was stopped is continued before operation is started) is possible by CX-Process Tool or FINS command. Standard: Operation of all is executed at the same operation cycle preset to ITEM 004 in the System Common. Settable operation cycles: 0.1 s, 0.2 s, 0.5 s, 1 s, 2 s (default: 1 s) Note: Cannot be set to the same operation cycle for some. Option: Operation of individual is executed at the same operation cycle preset to ITEM 004 in the System Common. Settable operation cycles: 0.01 seconds, 0.02 seconds, 0.05 seconds, 0.1 seconds, 0.2 seconds, 0.5 seconds, 1 second, and 2 seconds (default: 1 second) Note: The external I/O response cycle on a single control loop does not necessarily match the operation cycle. The response cycle is heavily dependent on the CPU Unit's cycle time. (See the external I/O response cycle item below.) The following operation cycles can be set for the listed below: 0.01, 0.02, and 0.05 s. Control/Operation : Block Models 016, 150, 151, 155 to 157, 167, 182 to 184, 186, and 221 to 224 Sequence control and Field Terminal The "LCB load rate" refers to the ratio between the actually applied execution time and preset operation cycle. The maximum value and current value are displayed for each operation cycle group on the CX-Process Tool. A LCB load rate of 80% or less is required in all operation cycle groups. When the load rate exceeds 80% for 6 seconds, the LCB load rate automatically changes to the next longer operation cycle. (This is called the "automatic operation cycle switching.") Note: The High Load Alarm Flag (A42408) turns ON if the load rate exceeds 80% for 6 seconds consecutively (non-fatal Inner Board error). (If execution is not possible within the operation cycle, the operation cycle will be extended.) If this happens, select the that can have longer operation cycles and increase their operation cycles. If the load rate is still too high, processing of the must be separated for processing by additional Loop Control Units. The time from external input of analog signals up to external output of analog signals on a single control loop depends on the 's operation cycle and the CPU Unit's cycle time. 4

Internal Operation Item Number of control loops Description The maximum number of loops that can be used if the LCB load rate is 80% for a standard applications (e.g., with each loop consisting of one Ai4 Terminal, Segment Linearizer, Basic PID, and A04 terminal) is shown in the following table. CJ1G-CPU43P/44P/45P (LCB03) 0.01 s: 20 loops 0.1 s: 100 loops 1 s: 150 loops Operation cycle: Maximum number of loops 0.02 s: 35 loops 0.05 s: 70 loops 0.2 s: 150 loops 0.5 s: 150 loops 2 s: 150 loops CJ1G-CPU42P (LCB01) Operation cycle: Maximum number of loops 0.01 s: 20 loops 0.02 s: 25 loops 0.05 s: 25 loops 0.1 s: 25 loops 0.2 s: 25 loops 0.5 s: 25 loops 1 s: 25 loops 2 s: 25 loops Control method Alarm Number of operations for process (excluding control) Sequential control (Use only one or the other) PID control Step ladders Possible control type combinations Integrated into PID Alarm Internal analog signal Operating status monitor method External I/O System common status signals Error display External I/O signals External contact I/O signals CPU Unit analog data I/O CPU Unit contact data I/O Analog/contact I/O with SCADA software FINS command to Loop Controller Status output signal for sequence control Clock timing output signal Calendar/clock output signal LCB01: Max. 50 LCB03: Max. 30 LCB01: Max. 20 per Board and total max. 2,000 commands per Board LCB03: Max. 200 per Board and total max. 4,000 commands per Board Loop Controllers common: Divisible to 100 commands max. per and 100 steps max. per (100 commands max. per step) PID with 2 degrees of freedom Basic PID control, cascade control, feedforward control, sample PI control, dead time compensation, PID control with differential gap, override control, program control, time-proportional control and other control types can be achieved by combining. 4 PV alarms (high/high limit, high limit, low limit, low/low limit) per PID, 1 deviation alarm High/Low Alarm, Deviation Alarm Min. 320.00% to max. +320.00% Scaling of the engineering units depends on the CX-Process Tool (sold separately). Executed by commercially available SCADA software. In the SCADA software, CSV tags set on the CX-Process Tool are specified. By data exchange with Analog I/O Unit via the Field Terminal By data exchange with Basic I/O Unit via the Field Terminal Total number of I/O points: (max. 8 points on Analog Input Unit or Analog Output Unit, or max. 96 points on Basic I/O Unit) 80 By data exchange with CPU Unit I/O memory via user link tables Total number of I/O points: 2,400 By data exchange with CPU Unit I/O memory via user link tables Data transfer between Loop Controller and I/O memory in CPU Unit for Control, Operation, and External Controller using HMI CJ1G-CPU42P: 2,040 CJ1G-CPU43/44/45P: 12,040 Read/write of ITEMs in Loop Controller and execution of run/stop commands are possible from the CPU Unit (including other networked nodes) or host computer by issuing the following FINS commands to the Loop Controller. READ MULTIPLE ITEMS IN FUNCTION BLOCK (0240 HEX) WRITE MULTIPLE ITEMS IN FUNCTION BLOCK (0241 HEX) READ ITEM IN MULTIPLE FUNCTION BLOCKS (0242 HEX) WRITE ITEM IN MULTIPLE FUNCTION BLOCKS (0243 HEX) READ UNIT INFORMATION (0501 HEX) ECHOBACK TEST (0801 HEX) READ ERROR LOG (2102 HEX) CLEAR ERROR LOG (2103 HEX) Constantly ON flags, constantly OFF flags, clock pulse (ON/OFF every 0.5 and 1 seconds) Differential output at 00:00 every day, noon every day, every 10 minutes, every minute and every 10 seconds Note: The CPU Unit's clock data are read as these clock data. Year, year/month, month/hour, day/time, hour/minute and minute/second Note: The CPU Unit's clock data is read as these clock data. By front panel indicators: hardware test error, database error, battery error Storage of execution-related error codes to ITEM 003 of each : source/ destination designation error, illegal combination, illegal parameter, etc. 5

Software Specifications The following software (sold separately) is required to use the Loop Controller: CX-Process Tool (included in CX-One): Tool for preparing data (essential) CX-Process Tool Specifications Item Product name Applicable PLCs Computer Applicable computer Operating system (OS) (See Note.1, 2) Japanese or English System CPU Memory Hard disk Display Disk Drive Software that must be installed with the CX-Process Tool Connecting method Connection with CPU Unit (or Serial Communications Board/Unit) Connection via Controller Link Connection via Ethernet Offline operation s Online operation s Specification CX-Process Tool (Included in CX-One Package) CS/CJ-series IBM PC/AT or compatible Microsoft Windows XP (Service Pack 3 or higher), Vista or 7 Proceccor recommended by Microsoft. Memory recommended by Microsoft. Approx. 2.8 GB or more of available memory is required to install all of the CX-One. XGA (1,024 768). High Color (16-bit) or higher. CD-ROM or DVD-ROM drive CX-Server or FinsGateway Using FinsGateway Serial Unit Driver Using CX-Server Using FinsGateway CLK (PCI) Driver Using FinsGateway Controller Link Driver or CX-Server Using FinsGateway ETN_UNIT Driver or CX-Server Communications protocol with PLC: Host Link or Peripheral Bus *2 Connect the computer to the peripheral port or built-in RS-232C port of the CPU Unit, or the RS-232C port of a Serial Communications Unit/Board. Connecting cable: When connecting to the CPU Unit peripheral port: CS1W-CN@@@ (2 m, 6 m) When connecting to the CPU Unit s RS-232C port: XW2Z-@@@-@ (2 m, 5 m) Communications protocol with PLC: Host Link or Peripheral Bus (The compatible connecting cables are the same as the ones shown above for the FinsGateway connection.) Install the driver in a computer equipped with a Controller Link Support Board (PCI slot) to support communications between the computer and PLCs equipped with a Controller Link Unit. Install the driver in a computer equipped with a Controller Link Support Board (ISA slot) to support communications between the computer and PLCs equipped with a Controller Link Unit. Install the driver in a computer equipped with an Ethernet to support communications between the computer and PLCs equipped with an Ethernet Unit. Setting of ITEM data (including System Common settings) Software wiring of analog signals Inserting, and printing text-string comments (memos) in or ladder diagrams. Describing Step Ladder Program commands Creating sequence tables Downloading of data (download/upload to and from Loop Controller) Run/stop command for Loop Controller (all ) System monitor run status: Monitoring/manipulation of System Common (Block Model 000) (including monitoring of LCB load rate) Loop Controller monitor run status: Confirmation of wiring operation (including operation stop/stop cancel on each ), confirmation of Step Ladder Program operation, and validation of sequence tables Initializing Loop Controller memory (RAM) Autotuning PID constants and other parameters. *1. CX-One Operating System Precaution: 1)System requirements and hard disk space may vary with the system environment. 2)Except for Windows XP 64-bit version. *2. Peripheral Bus cannot be used when FinsGateway V3 is used. Note: The CX-Process s that can be used depend on the version. For details, refer to the operation manuals (Cat.No.: W372-E1-@ and W373-E1-@). 6

Functional Element Versions and Programming Devices The Programming Device that supports the al element version code must be used to enable all the s in the corresponding al element. Note: Upgrading versions is not necessary if only the basic s of the CPU Unit element are required. Loop Controller Element Loop Controller Programming Device Functional element name Functional element version CX-Process Tool CX-Programmer (See note.) Ver.1.0 Ver. 3.0 or higher Ver.1.5 Ver. 3.2 or higher LCB01 Ver.2.0 Ver. 4.0 or higher Ver.3.0 Ver. 5.0 or higher Ver.3.5 Ver. 5.2 or higher Ver.3.6 Ver. 5.23 or higher Ver.2.0 Ver. 4.0 or higher LCB03 Ver.3.0 Ver. 5.0 or higher Ver.3.5 Ver. 5.2 or higher Ver.3.6 Ver. 5.23 or higher LCB03-GTC Ver.3.0 Ver. 5.1 or higher 7

External Interface A CJ1-series CPU Unit provides two communications ports for external interfaces: a peripheral port and an RS-232C port. LED Indicators Battery Compartment Memory Card Power Supply Switch Press the power supply switch to disconnect power before removing the Memory Card. Also, press the Memory Card Power Supply Switch to perform an easy backup operation. SYSMAC CJ1G-CPU44P PROGRAMMABLE CONTROLLER OPEN MCPWR BUSY RUN ERR/ALM INH PRPHL COMM PERIPHERAL PORT DIP Switch (Inside the battery compartment) Used for initial settings. Memory Card Indicators MCPWR (green): Lit when power is supplied to Memory Card. BUSY (orange): Lit when Memory Card is being accessed. Peripheral Port Connected to Programming Devices, such as a Programming Console or host computers. Memory Card Connector Connects the Memory Card to the CPU Unit. RS-232C Port Connected to Programming Devices (excluding Programming Consoles), Host Computers, general-purpose external devices, Programmable Terminals, and other devices. Peripheral port Memory Card Eject Button Press the eject button to remove te Memory Card from the CPU Unit. The peripheral port is used to connect a Programming Device (including a Programming Console) or a host computer. It can also be used as an RS-232C port by connecting a suitable cable, such as the CS1W-CN118 or CS1W-CN@26. The connector pin arrangement when using a connecting cable for an RS-232C port is shown below. 1 6 CS1W-CN118 5 9 Pin No. Signal Name Direction 1 2 SD (TXD) Send data Output 3 RD (RXD) Receive data Input 4 RS (RTS) Request to send Output 5 CS (CTS) Clear to send Input 6 Reserved None 7 8 9 SG (0V) Signal ground Connector hood FG Protection earth 8

Dimensions CPU Units Loop-control CPU Units CJ1G-CPU42P CJ1G-CPU43P CJ1G-CPU44P CJ1G-CPU45P (Unit: mm) 2.7 SYSMAC RUN CJ1G-CPU45P ERR/ALM PROGRAMMABLE INH CONTROLLER PRPHL COMM LCB03 RDY EXEC INNER LOOP CONTROLLER OPEN MCPWR BUSY 90 PERIPHERAL PORT 2.7 65 69 73.9 About Manuals Cat. No. Name Contents W406 W407 W444 W372 W418 W393 W394 W340 SYSMAC CS/CJ Series CS1W-LCB01, CS1W-LCB05, CS1D-CPU@@P, and CJ1G-CPU@@P Operation Manuals SYSMAC CS/CJ Series CS1W-LCB01, CS1W-LCB05, CS1D-CPU@@P, and CJ1G-CPU@@P Function Block Reference Manual CXONE-AL@@D-V@ CX-One FA Integrated Tool Package Setup Manual SYSMAC CS/CJ Series CX-Process Tool Operation Manual Faceplate Auto-Builder for NS Operation Manual SYSMAC CJ Series Programmable Controllers Operation Manual CJ1G/H-CPU@@H, CJ1G-CPU@@P, CJ1MCPU@@, CJ1G-CPU@@ SYSMAC CS/CJ Series Programmable Controllers Programming Manual CS1G/H-CPU@@-EV1, CS1G/H-CPU@@H, CS1DCPU@@H, CS1D-CPU@@S, CJ1G/H-CPU@@H, CJ1G-CPU@@P, CJ1M-CPU@@, CJ1G-CPU@@ SYSMAC CS/CJ Series Programmable Controllers Instructions Reference Manual CS1G/H-CPU@@-EV1, CS1G/H-CPU@@H, CS1DCPU@@H, CS1D-CPU@@S, CJ1G/H-CPU@@H, CJ1G-CPU@@P, CJ1M-CPU@@, CJ1G-CPU@@ Describes the basic running of the Loop Control Boards (excluding detailed descriptions of the ). Provides detailed information on the. Provides an overview of the CX-One FA Integrated Tool and installation procedures. Describes operation of the CX-Process Tool. Describes operation of the software that generates NS-series PT projects from a SCADA CSV file output by the CX-Process Tool. Provides an outlines of and describes the design, installation, maintenance, and other basic operations for the CJ-series PLCs. Describes programming and other methods to use the s of the CS/CJ-series PLCs. Describes programming and other methods to use the s of the CS/CJ-series PLCs. 9

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2016.4 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2016 All Right Reserved.