Insulated Enclosure KO 4763 with box terminals for solder or plug-in technology

Similar documents
Insulated Enclosure KO 4733 with twin-level box terminal for plug-in technology

Insulated Enclosure KO 4730 with twin-level box terminal for plug-in technology

Insulated Enclosure KU 4087, KU 4088 KU 4089 to DIN for installation in distribution cabinets or surface mounting

Insulated Enclosure KU 4090 to DIN for installation in distribution cabinets or surface mounting

Insulated Enclosure KU 4091 to DIN for installation in distribution cabinets or surface mounting

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

In-Rail-Bus Bus system in DIN-rail

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety.

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

- 1 - General ordering data Order No

Installation / Control Technique

- 1 - General ordering data Order No

PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03

PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03

Item No.: /

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

Data sheet... OMNIMATE Power - series BL/SL 7.62HP BLZ 7.62HP/04/180LR SN BK BX

Altech s DIN Enclosures by

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135

IDG-B Enclosures for Industrial and Building Automation Controls.

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

Powermate Range pitch 10.16

PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03

Devices raised mounting

High-density multi-pin connectors

PHOENIX CONTACT - 05/2007

RACON short-travel keyswitches

Power Electronics. Semiconductor relay / - contactor

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Connectors DIN 41612/IEC

PCB-COMPONENTS PCB-COMPONENTS CATALOGUE 2002/03 CATALOGUE 2002/03

Electrical Interconnection

Power distribution systems - accessories

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

PCB Keyswitches Product Survey Versions Recommended Key grid Illumination Keyswitch Signal indicator Keyswitch height Contacts RACON 8 12 mm Non-illum

Technical data: Pin Spacing

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Electrical Connection Technology. New Items: Autumn 2007

High-density multi-pin connectors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Faults on the system Proximity switch connection technology:

Time Counters mini "h", DC Version

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Switches and Indicators 84

onlinecomponents.com

Description of parts Panel mounting Insert mounting without/with Carrier element Plastic housings

Accessories for pluggable interface relays CR-P Sockets

Devices raised mounting

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

Horizontal distribution busbar HX 3 80/125 A plug-in

RM84 miniature relays

Male connector; with fixing flanges; 6-pole; pin spacing 5.08 mm / 0.2 in; for screw or similar mounting types; for parallel or perpendicular mounting

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Accessories for pluggable interface relays CR-M Sockets

Electrical Interconnections. Supplementary Catalog to Full Line Catalogs, Volumes 1/2/5 Edition 2012/2 1/2/5

Installation / Control / Monitoring Technique

Resistance measuring module

H S11I1A I2A I3A I4A I5A I6A I7A I8A S21I1C I2C I3C I4C I5C I6C I7C I8C 14A I 15A I 16A 13A I 13B 14B 15B 16B M8540

UTME 6. Extract from the online catalog. Order No.:

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Packing density, redefined mm pitch, 2 rows more convenience despite the small pitch

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

IDC Assembly (depends on cable) -55/125 C. IDC Assembly (depends on cable) By ambient temperature: 20 C 1,2 A 70 C 0,9 A 100 C 0,6 A

Power Supply HARTING pcon

Thermal-Magnetic Circuit Breaker 2216-S

SUNCLIX Connection technology for photovoltaics

TXM1.8RB. TX-I/O Blinds module

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Safety technique. Emergency-stop monitor BH 5922, BL 5922 safemaster

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Male connector; 6-pole; pin spacing 3.5 mm / in; 100% protected against mismating

Power Supply HARTING pcon

PERFECTLY COMBINED YOUR ADVANTAGES. Suitable for DIN rails EN TH35 or direct

H S11I1A I2A I3A I4A I5A I6A I7A I8A S21I1C I2C I3C I4C I5C I6C I7C I8C 14A I 15A I 16A 13A I 13B 14B 15B 16B M8540

LUMOTAST 25 selector switch 1-28 LUMOTAST 25 selector switch, ring nut fixing LUMOTAST 25 keylock switch 1-30 LUMOTAST 25 keylock switch 1-31

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Enclosures LDG-A. Catalog E /10 Edition 2

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

DOR6. Components All functions and indications are on the front of the module. Characteristics

Digital input modules

SL 7.62/8/90B3.2SN OR - Weidmüller

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Classification Enclosure rating Input voltage Type of

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Electronic timer CT-ERD.12

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Probably the fastest enclosure in the world

GSV-1A4 M12/2 M12/2. Highlights

PHOENIX CONTACT - 01/2008

ALPHA SIMBOX Small Distribution Boards

DIN Rail Terminal Blocks taris

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Transcription:

Insulated Enclosure KO 4763 with box terminals for solder or plug-in technology Technical Data Width 45 mm Max. 16 box-terminals with captive plusminus-screws Electrical connection from PCB to terminal in solder or plug-in technology Mounting of SMD components possible on soldering side Available with removable terminal strips Available with changeable plate Spacer for PCB coding With changeable print area Order references: Front colour beige light grey RAL 7035 blue RAL 5015 Enclosure version with Machine soldering KO 4763.120.16.04.000.007.010 front plate KO 4763.120.16.04.001.008.011 plate KO 4763.120.16.04.002.009.012 plate clear Solder technology with soldering lug KO 4763.120.16.04.025.028.031 front plate KO 4763.120.16.04.026.029.032 plate KO 4763.120.16.04.027.030.033 plate clear Plug-in technology with terminal plate KO 4763.120.16.03.001.002.007 front plate KO 4763.120.16.03.004.009.011 plate KO 4763.120.16.03.005.010.012 plate clear Plug-in technology with removable terminal strip KO 4763.120.16.05.000.003.006 front plate KO 4763.120.16.05.001.004.007 plate KO 4763.120.16.05.002.005.008 plate clear Outer dimensions: Enclosure material: Temperature stability: complying with UL 746 B: 125 C complying with Vicat ISO 306 Meth. B: 148 C compl. with ISO 75-2 Meth. A: Meth. B: 45 x 73,5 x 118,2 mm PC-GF, base black, front colour see table 138 C 144 C Max. permitted power dissipation: 15 W for stand-alone enclosure at normal climate 23/50-1 ISO 554 specific thermal resistance: Rth = 6.5 K / W for stand-alone enclosure Flame retardancy: complying with UL 94: V-0; plate clear = V-2 Number of terminals: 16; < 16 on request Contact material CuSn tin-plated CuBe tin-plated Max. cross section for connection: max. 1 x 2.5 mm 2 stranded ferruled DIN 46 228-1/-2/-3/-4 max. 1 x 4 mm 2 solid max 2 x 1.5 mm 2 stranded ferruled DIN 46 228-1/-2/-3/-4 min. ø 0.1 mm Insulation of wires length: 10 mm Max. contact resistance to printed circuit board: 10 mω Max. current carrying capacity: 16 A 10 A Wire fastening: captive plus-minus-terminal screws M3.5 box terminals with self raising wire protection Torque: max. 0.8 Nm Inner connection: machine soldered beded solder pins, available with straight solder pins for horizontal PCB or with soldering lug for wiring connection or direct connection of PCB Enclosure fastener: 1) Snap-on fastener on top hat rail IEC/EN 60 715 2) Screw fixing as special version M4-grid 35 x 5 M5-grid 35 x 60 by Adapter ET 4762-5 Creepage current resistance: CTI 175 insulated material III a IEC 60 664-1 All specifications correspond to the technology used at time of publication. We reserve the right to make improvements and changes of a technical nature at any time. 1

plus-minus terminal screw M3.5 wire protection Air gap and creepage distance: 3.3 mm IEC 60 664-1 Type of protection: Enclosure IP 40 IEC 60 529 Terminals IP 20 IEC 60 529 contact protection complies with VBG 4 Print area: 45 x 43 mm (on front plate) Printed circuit board: 33 / 22 cm 2 Printed circuit board holder: Guide ribs on the small side Guide ribs on the wide side solder pin (bended) Printed circuit board Box terminal for machine soldering Accessories: ET 4762-5: KO 4721-7-1.24: KO 4721-7-1.22: KO 4721-8-1: Adapter Blanking plug clear Blanking plug clear Spacer for PCB coding Plus-minusterminal screw M3.5 Wire protection Soldering lug PCB Box terminal for soldering with soldering lug Plus-minusterminal screw M3,5 Wire protection Contact spring PCB Box terminal for plug-in technology 2

Machine solder technology PCBs * Terminal carrier Top section Solder technology with soldering lug PCBs * Terminal strip Printed circuit board design for machine solder technology and solder technology with soldering lug Machine solderable vertical PCB Horizontal PCB soldered between vertical PCBs inhibited surface 1 ) Tolerance according to IEC 60 249-2-4 General tolerance: PERFAG E2 Applicable for solder technology with soldering lug only 3

Dimensions _ In this area openings and ribs are poosible to customers specification Print area exchangeable for terminal plate in one piece top hat rail IEC/EN 60 715 Plug-in technology with pluggable terminal plate Plug-in technology with removable terminal strip PCB * Spacer ** with integrated connection socket PCBs * Spacer ** Terminal strip Printed circuit board design for plug-in technology 1 Vertical PCB plugged into terminal block Horizontal PCB soldered between vertical PCBs inhibited surface 1 ) Tolerance according to IEC 60 249-2-4 General tolerance: PERFAG E2 4

Notes on Housing Opening 1. Tool for all functions use 0.8 x 4.0 or 0,8 x 4,5 screwdriver 2. Removing of frame Insert a screwdriver in the side recesses of the base (underneath) The snap-in lug of the frame disengages. Repeat disengaging process on opposite side. The frame can be removed. Notes on Housing Opening Installation with pluggable terminal plate 1. Tool for all functions use 0.8 x 4.0 or 0.8 x 4.5 screwdriver pluggable terminal plate 2. Removing of teriminal plate Insert a screwdriver in the side recesses of the base (underneath) The snap-in lug of the terminal plate disengages. Repeat disengaging process on opposite side. Terminal plate can be removed. 3. Demontage der Platte Insert a screwdriver in the side recesses of the plate disengages and und can be removed. M8305_a plate 5

Notes on Housing Opening Installation - removable terminal strip 1. Tool for all functions use 0.8 x 4.0 or 0.8 x 4.5 screwdriver 2. Removing of terminal strip Insert a screwdriver between terminal strip and front frame Unclip the terminal strip by suriveling the screwdriver in the direction of the lug. Terminal strip can be removed terminal strip 3. Removing of frame Insert a screwdriver in the side recesses of the base (underneath) The snap-in lug of the frame disengages. Repeat disengaging process on opposite side. The frame can be removed. frame E. DOLD & SÖHNE KG D-78114 Furtwangen e-mail: GV-Vertrieb@dold.com internet: http://www.dold.com PO Box 1251 Telephone (+49) 77 23 / 654-0 Telefax (+49) 77 23 / 654-356 6